| 1 | M&L for complete removal of existing surfaces treatment from old, plastered or unplastered decorated wall surfaces, and applying minimum 1.5mm thick wall care putty including sanding of the putty surface after drying to achieve even and smooth finish and applying two coats of acrylic distemper over a coat of primer complete all as specified and directed. |
| 2 | M&L for prepration of old decorated surfaces of walls (plastered or unplastered) and applying one coat of acrylic distemper complete all as specified and as directed. |
| 3 | M&L for prepration of old decorated surfaces of walls (plastered or unplastered) and applying two coats of acrylic distemper complete all as specified and as directed. |
| 4 | M&L for complete removal of existing treatment from old plastered or unplastered ceiling surfaces and applying minimum 1.5mm thick wall care putty including sanding of the putty surface after drying to achieve even and smooth finish and applying two coats of acrylic distemper over a coat of primer complete all as specified and directed. |
| 5 | M&L for preparation of old plastered or unplastered decorated ceiling surfaces and applying one coat of acrylic distemper complete all as specified and as directed. |
| 6 | M&L for preparation of old plastered or unplastered decorated ceiling surfaces and applying two coats of acrylic distemper complete all as specified and as directed. |
| 7 | M&L for prepration of old decorated surfaces of walls (plastered or unplastered) and applying one coat of cement base paint complete all as specified and as directed. |
| 8 | M&L for complete removal of existing surface treatment from old plastered or unplastered decorated wall surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and as directed. |
| 9 | Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed. |
| 10 | M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surface finished even and smooth without using extra cement all as specified and as directed. |
| 11 | M&L for preparation of newly plastered wall surfaces of brick (plastered or un-plastered) or concrete surfaces and applying minimum 1.5mm thick wall care putty including sanding of the putty surface after drying and applying two coats of acrylic distemper over a coat of primer using roller complete all as specified and as directed. |
| 12 | M&L for 15 mm thick rendering in cement mortar 1:4 (using water proofing liquid as per manufacturers instruction) on other than fair faces of brick masonry surfaces or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed.Note : Cost of water proofing compund is inclusive in the item. |
| 13 | M&L for 5 mm thick rendering in cement mortar 1:4 on fair faces of concrete ceiling surface, finished even and smooth without using extra cement, all as specified and as directed. |
| 14 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of acrylic distemper over a coat of primer using roller all as specified and as directed. |
| 15 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed. |
| 16 | M&L for applying waterproof wall care putty over prepared surface (thickness vary from 1.5 to 2mm as required for desired smoothness and levelling of surfaces in two or more layers) including sanding of the putty surface after drying to achieve even and smooth finish for receiving paint complete all as specified and directed. |
| 17 | M&L for preparation of old decorated surfaces of walls /roof projections including facia, cornices, etc including filling of cracks/holes by crack filler and applying one coat of exterior acrylic emulsion paint, Alkali & fungal resistance, dirt resistance, of required shade over prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed by Engr-in-charge. |
| 18 | M&L for complete removal of existing treatment on wall/roof projections including facia, cornices, etc by scrapping with mechanical sander (having mechnical vaccum mechanism ) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc by skilled labour including filling of cracks/holes by crack filler and applying Two or more coats of exterior acrylic emulsion paint, Alkali & fungal resistance, dirt resistance, of required shade over and including priming coat of exterior alkali resistant primer applied @ 0.90 litre/ 10 sqm on prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed by Engr-in-charge.Note:1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces by using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr.The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure complete as approved by Engr-in-Charge .2. Allow 6-8 hrs to dry the surface for painting of subsequent coats. |
| 19 | M&L for preparation of Newly plastered wall surfaces and applying two or more coats of 100% premium exterior acrylic emulsion paint, Alkali & fungal resistance, dirt resistance, of required shade over and including priming coat of exterior alkali resistant primer applied @ 0.90 litre/ 10 sqm on prepared surface of brick (plastered or un-plastered) or concrete surface complete all as specified and directed by Engr-in-charge.Note:1. Exterior Primer & Acrylic emulsion paint to be applied on wall surfaces by using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr.The spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure complete as approved by Engr-in-Charge .2. Allow 6-8 hrs to dry the surface for painting of subbsequent coats. |
| 20 | M&L for writing letters or figures (Block. Roman, Italic or Indian) n exc. 30 cm high complete all as specifed and as directed. |
| 21 | M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 22 | M&L for preparation of old painted surfaces of steel/iron/CI pipes of any description exceeding 10cm width or girth and applying one coat of black bituminous paint complete all as specified and directed by Engineer-in-Charge. |
| 23 | M&L for preparation of surfaces of floor and applying one coat of floor guard of approved shade complete all as specified and directed by Engineer-in-Charge. |
| 24 | M&L for preparation of roof tile at any height (up to 10m) and applying two coat of tile guard of approved shade including required scaffolding etc by Engineer-in-Charge. |
| 25 | M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. |
| 26 | Dismantling of rain water pipe (PVC, AC, or re-inforced concrete ) of any size including all fittings, heads, shoes, bends, swan-necks, etc (measured overall as fixed along with the centre line over fittings and accessories) complete all as specified and directed. |
| 27 | S&F in repairs PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall using clamps complete all as specified and directed. |
| 28 | S&F in repairs PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints fixed to wall using clamps complete all as specified and directed. |
| 29 | S&F in repairs PVC (SWR) vent cowl 110mm bore complete all as specified and directed. |
| 30 | S&F in repairs PVC (SWR) vent cowl 75mm bore complete all as specified and directed. |
| 31 | S&F in repairs 110 mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 32 | S&F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. Please Enable Macros to View BoQ information |
| 33 | S&F in repairs 75 mm bore PVC (SWR) bends any radius complete all as specified and directed. Please Enable Macros to View BoQ information |