| 1 | Earth work in excavation by Machnical means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in weidth) Including disposil of excavated soil up to 1 Mtr and lift up to 1.50 Mtr |
| 2 | Providing and laying of stone solling hand Packed Including all Carriages |
| 3 | Providing and laying ofCement Concrete excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Filling by available excavated earth (excluding rock) in trunches,plinth,sides of fondation etc, in layers not exceding 20 Cm in depth ,consolidation each deposited layer by ramming and watering lead upto 50m and lift upto 1.5 m. (Below proposed ground Level in Rooms) |
| 5 | Providing and laying of RBM in rooms including ramming, Watering ETC Complete Job in Rooms Including all Carriages |
| 6 | Providing and laying of Rainforcement Cement Concrete excluding the cost of centring and shuttering. All work upto plinth level with 1:1.50:3 (1 cement : 1.50 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 7 | Reinforced cement concrete work in beams, suspended floors, columns roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) (Concrete cubes tests, to be done by contractor, will be cast during execution and after test report of cubes bill will ne prepared) |
| 8 | Providing and laying of Cement Concrete excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Centring and Shuttring |
| 10 | Centering and shuttering including strutting, propping etc. and removal for foundation in Footing up to plinth level |
| 11 | Centering and shuttering including strutting, propping etc. and removal for Suspand floors |
| 12 | Centering and shuttering including strutting, propping etc. and removal for Lintills, Beams, Griders, ETC |
| 13 | Centering and shuttering including strutting, propping etc. and removal for Column. Pillers, Abutments ETC |
| 14 | Providing & Fixing of TMT steel Including cutting, bending,Binding and placing in position |
| 15 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in superstructure upto floor v level h including curing in 1:6 mix (1 Cement :6 Course sand) (work shall be commence only after the Brick test is conducted by approved lab, at the contractors cost) |
| 16 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 17 | Providing wood work in frames of Doors,windows, clerestory window and other frames,wrought frames and fixed in position. (imported KD Wood) |
| 18 | Providing 40x5 mm flat iron hold fast 22 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 19 | Providing and fixing 30 mm thick glazed shutter for windows and clearstory windows using 10kg/sqm (4mm thick)glass panes including black enamelled ISI marked M.S hinges with necessary screws. Imported wood (KD) |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood(KD) and well matched teak face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 30 mm thick |
| 21 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 30 mm thick Walnut Wood Carved and finished Properly (First class imported kail wood) |
| 22 | Providing and fixing of 3.50 mm thiock Glass Pains for Window Big Shutters Inclunind necessary Beading and nails |
| 23 | Handle 5\\" Al for Windows |
| 24 | Handle 8\\" fancy type For Door |
| 25 | Handle 12\\" fancy type For Door |
| 26 | Handle 6\\" AL for Door inner Side |
| 27 | T-Bolts (4\\") for Windows |
| 28 | T-Bolts (6\\") For Doors |
| 29 | Door Al-drop with lock Link/ ramson 12\\" |
| 30 | Door Al-drop with lock Link/ ramson 10\\" \\" |
| 31 | Door stopper |
| 32 | Stay hook 5\\" |
| 33 | P/F of Vetrifed Glazzed Floor Tiles of Size (600x600)mm of approved quality of (Kajaria,Sumania,Nitco or equal to it) 20 mm thick 1:4 mix cement mortor |
| 34 | P/F of Ceramic Glazzed Wall Tiles of approved quality of (Kajaria,Sumania,Nitco or equal to it) of different size and including 20 mm thick 1:4 mix cement mortor |
| 35 | Gang Saw Cut mirror polished premoulded and prepolished machine cut for kitchen Plateforms vanity Countrs Etc of reqired Size of approved Shade and Colour and texture laid in 16 mm thick base of cement mortor 1:4 mix 1: Cement :4 Coarse sand complete Job |
| 36 | 12 mm thick cement plaster in 1 : 4 (1 cement : 4 fine sand) on Brick Work in side Room Walls |
| 37 | 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) including all lifts,leads,carriage of the material. |
| 38 | Providing and applying of Plaster of Paris Putty of 2 mm thick over Cement Platered Surface to prepare the surface an even and Smooth Complete Job |
| 39 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 40 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primer |
| 41 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/ 0sqm) |
| 42 | Applying priming coat with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood). |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade. Two or more coats on new work. |
| 44 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position including welding etc and applying a priming coat of approved steel primer all complete.( SAIL,TATA, Rashtriya Ispat nigam limited etc the like) |
| 45 | Providing of Colour Coated high Rib Profile G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cutting to size and shape. 0.50mm thick |
| 46 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. |
| 47 | P/Fixing of 0.20 mm colour coated Panelling sheets for soffits and eves boarding & sides incl all fixtures complete job |
| 48 | Providing and fixing of soffits made out 12mm thick imported wood planks incl underneath frame work and scaffolding carriage complete (Badloo work ) |
| 49 | Providing and of Indian Type China WC pan of (575x425)mm sizeincluding 100 mm P. Trape and 10 Ltr Flush tankey with PVC Connection |
| 50 | Providing and of English Type China WC pan of (575x425)mm sizeincluding 100 mm P. Trape and 10 Ltr Flush tankey with PVC Connection |
| 51 | P/F of Wash Basen with Padistal including wast Pipe and Pvc Connectio Complete Job |
| 52 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board (610x460mm bowl depth 200mm) |
| 53 | Providing and Fixing of PPR Fitting 20 mm |
| 54 | Providing and Fixing of PPR Fitting 15 mm |
| 55 | Providing and Fixing of of PVC 100 mm Siol Waste Pipe |
| 56 | Providing and Fixing of PVC 75 mm Soil Waste Pipe |
| 57 | Providing and Fixing of PVC100 mm Plan bend |
| 58 | Providing and Fixing of PVC 75 mm Plan bend |
| 59 | Providing and Fixing of PVC 100 mm Color |
| 60 | Providing and Fixing of PVC 75 mm Color |
| 61 | Providing and Fixing of PVC Vent Pipe with Covel |
| 62 | Providing and Fixing of PVC 100 mm Door Junction |
| 63 | Providing and Fixing of PVC 75 mm Door Bend |
| 64 | Providing and Fixing of PVC 100x75 mm Reducer Socket |
| 65 | Providing and Fixing of Triple Layer PVC Water Storage Tank |
| 66 | Providing and Fixing of 15 mm Bore Brass Bibcock(Jaquar) |
| 67 | Providing and Fixing of 15 mm Bore Angle Cock (Hot and Cold) For wash basin(Jaquar) |
| 68 | Providing and Fixing of 15 mm Bore Angle Cock (Hot and Cold) For sink |
| 69 | Providing and Fixing of Brass Angle value (Jaquar) |
| 70 | Providing and Fixing of CP Brass ball Value 20 mm Bore |
| 71 | Providing and Fixing of MS Clamps fpr PVC Pipes |
| 72 | Providing and Fixing of PVC 75 mm Floor Trap |
| 73 | Providing and Fixing of CP jalli |
| 74 | Providing and Fixing of 20 mm bore brass stop cock of approved quality |
| 75 | R. R. Stone massonery Laid Dry of standred Nallah Stones with Bond Stones |
| 76 | Providing and laying of 25 mm thick Cement Concrete flooring in 1:2:4 Mix (1 cement : 4 coarse sand : 4) graded stone aggregate 20 mm N/S) |
| 77 | Carriage of Sand by MT for 30 Kms |
| 78 | Carriage of Aggrigate by MT for 45 Kms |
| 79 | Carriage of Solling/RBM by MT for 5 Kms |
| 80 | Carriage of bricks by MT for 95 Kms |
| 81 | Carriage of stones by MT for 20 Kms |
| 82 | Carriage of Cement.Iron and Steel by for 15 Kms |
| 83 | Cost of HD Coloured Photographs 8x10 |
| 84 | Provision of foundation & inauguration Granite Stone (19mm thick) of required size and shape. Provision for Rock cutting in foundationwith cheisel (actual measurement will be produced after execution) |
| 85 | Chesil cutting of hard rock without blasting (To be paid as per actual) |
| 86 | ELECTRICAL PART |
| 87 | Wiring for light points, Fan Points, Exhaust Fan Points with (P+N+E) 3x1.5 Sq. mm FRLS-H PVC insulated multi strand copper conductor laid in suitable, (Havells/ Anchor/ Eq. Make) in surface/ Recessed Conduit liaid in slab (Including cost of conduit 25 mm) with 01 No of 6 Amp Modular switch, Modular plate, Cover in frount & sutaible GI Box etc ISO/ IEC certified/ Schneider/ Havells/ Legrand/ Anchor roms Plus/ABB/ Eq. Make & alongwith 2.5 Sq. mm (P+N+E)Circuit wireof same same name as menioned above & items shall ne Approved before execution of work by SDO |
| 88 | Supply and fixing of Two Modular Stepped Type wlwctronic fan regulator on the existing Modular Plate Switch box Including connections but Excluding Modular plate etc as required, ISO/ IEC certified of Havells/ Legrand. Anchor/ Schneider / ABB/ Eq. Make & shall be approved before execution of work by SDO |
| 89 | Wiring of Power Plug with (P+N+E) 3x4 Sq. mm FRLS-H PVC insulated multi strand copper conductor Single Conductor Single Core Cable in surface/ Recessed ConduitHhavells/ Anchor/ Eq. Make 1RM=3metres i/c conduits and paid as per actual |
| 90 | Supply and Fixing of Suitable Size GI Box with Modular plate & Cover in Frount on surface or in recess, including providing and Fixing of 6 Pin 5/6 &15/16 A Modular Socket out let and 15/16 A Modular Switch, Connection etc as required, ISO/ IEC certified/ Legrand/ Anchor roma Plus/ Schneider/ ABB/ Eq. Make & shall be approved before ececution of Work by SDO |
| 91 | Wiring of 6 Amp Plug (Computer Point) woth (P+N+E) 3x2.5 Sq. m FRLS-H PVC Insuated multi Srtand Copper conductor Single Core on surface/ Recessed Conduit ( Havells/ Anchor/ Eq. Make) 1RM=3 Metrs i/c conduits and paid as per actual |
| 92 | Supply and Fixing of Suitable Size GI Box with Modular plate & Cover in Frount on surface or in recess, including providing and Fixing of 02 No 3 Pin Modular Socket outlet and 02 No 5/6 &15/16 A Modular Switch, Connection etc as required (for lighting to be used non residential buildings), ISO/ IEC certified/ Legrand/ Anchor roma Plus/ Schneider/ ABB/ Eq. Make & shall be approved before ececution of Work by SDO |
| 93 | Wiring Su Main along with earth wire with the folloeing size of FRLS-H PVC insulated Copper Conductor , Single Core cable in Surface/ Recessed medium Class PVC Conduit (Havells/ Anchor/ Eq. Make) & shall be approved before execution of work by SDO |
| 94 | 2x 10 Sq. mm + 1x 6 Sq. mm earth wire for Heating Sub Main |
| 95 | 2x 6 sq. mm + 1x 6 Sq. mm earth wire for Lighting and Machine Sub Main |
| 96 | 2x 4 Sq. MM +1x 4 Sq.mm earth Wire for Invertor Sub Main |
| 97 | Supply/ Fixing / Testing and Commissioning of 6 Amp to 32 Amp rating SP.240V. *C* Curve 10K Miniature Circuit Braker Suitable for Inductive Load of Following Ploes in existing MCB, DB Complete with Connections, (L&T/ Siemens/ Legrand/ Havells/ ABB/ Eq. Make) |
| 98 | Supply/ Fixing / Testing and Commissioning of follwing rating, Double Pole, (P+N) 240 V, *C* Curve 10K Miniature Circute Braker (MCB) in the Existing MCB, DB Complete with Connections, (L&T/ Siemens/ Legrand/ Havells/ ABB/ Eq. Make) |
| 99 | 40 Amp |
| 100 | 32 Amp |
| 101 | 63 Amp |
| 102 | Supply and Fixing of MCB 6 way (4+18), Horizontal Tayped, Sheet Steel, Double Door Distribution Board, TPN 240V/415V, on Surface/Racess, Complete with Tinned Copper bus Bar, natural Bus Bar, Earth Bar, Din Bar, interconnections, Powder painted including earthing etc, as required. ( L&T/ Siemens/ Legrand/ Svhneider/ ABB/ Eq. Make) |
| 103 | Supply/ Fixing / Testing and Commissioning of 18 W +LED Conceal (Commercial Type) light Luminary fitting round Shape with minimum System Lumen efficacy of 100 Im/W with Pressure Die cast Aliminum Heat Sink and P.F >0.95, THD <10%, CCT 5700K, CRI 80. The LED with useful life of 50000 Hrs at L70. The Input Voltge Range shall be 150V to 270V. The Fixture Should have inbuilt Surge Protection of 2KV. Certifcation:- LM 79 & LM80 test report Should be from Govt; Approved in-house NABL Lab/ Govt; of India authourised Lab. The Job incudss AMC( reckoned from date of successful Commissioning) of Lighting Fixtures for a period of Two year , Which includs replacements of fixtures of Philips/ Havells/ Wipro/ Halonix/ eq. Make) |
| 104 | Providing and Fixing of IK08 IP-66 protected high Power LED 50 Watt Flood light syatem with Single Piece Pressure diecast aluminium housing, toghened glass diffuser with sutable lense on LED to achieve veriousbeam angle, of high Power LED of 3 to 5 watt each. Integrated apotted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certifcate. The system level level luminaire efficacy >=125 Im/Wt. LED driver input Voltage AC 120 to 270 V AC with high Voltage Cutoff @ >= 300V AC and Auto resetting safety. Power factor >0.95, THD (I)<10%, driver Current <= 750mA. Driver should be phase to phase Protection of 440 V for 4 Hrs. Electric Connector, Surge Protection Min>=4KV internal and 10KV external but inside driver Compertment, System life of 50000 Burning hourse hourse with 70% of intial Lumens maintained, CRI>70 and CCT 5799K 355K manufacture Word Mark/ name Engraved/ Embossing/ Screen Printing on Dia cast housing to allow traceablity/ authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL Lab setup for all testing facilities for LED fixtures. (LM70/LM80) Certificate/ report with liable warranty of Engineer in Charge. For additional technical parameters of Products/ Work, Refer Annexure \\"A\\" attached with this BSR- High Power LED Flood light Minimum Lumen Out Put 6200 Im of as Approved and to installed on Outside Block Including S/F of Suitable Size of Gyser Bolt. The Job Further includs replacement warranty of Fixture (if damage/ Burnt out what so ever reason) for a period of two reckoned from from date of Suceddful Commissioning / handing Over of Site to intending Department. (Havells/ Plilips/ Wipro/ Halonix/ Eq. Make) |
| 105 | Supply / Installation / Testing and Commissioning of 1200 mm BLDC Sweep, Ceilling fan with 03 No, Blades, 30 Cm Long down Rod, 02 No, Canopies, Shackle Kit, Power factor not less than0.9, Service value Including saftyPin, Nut Bolts, washers, temperature rise=75 degree (Max). insulation resistance more than 2 mega ohm, Suitable for 230 V, 50 Hz single Phase Supply, etc Complete as required. USHA/ Havells/ Anchor/ Crompton / Greaves/ Eq. Make (Minimum 1-Star) |
| 106 | Supply / Installation / Testing and Commissioning of 225-250 mm shutter Typed, 320 Cu.m/hr. AC 220-240 Volts, 50 Hz Exhaust fan made out od ABS Plastic Material with inbuilt thermo Cut-Off Protection and Noise level not Exceeding 37 dB of Following size including Connection etc USHA/ havells/ Crompton/ eq. Make (Min 1- Star) |
| 107 | Supply/ Laying/ Connecting and Commissioning of 70 Sq. mm 3.5- Core XLPE/PVC insulated and Steel armored 1.1 KV Grade Aluninum cable of Havells/ Polycab/ eq. make with required Size of Thimbales Dully Crimped with Hydraulic crimping tool including Prividing/ Fixing of daffles/ Clips with making of Connection and pattially to be laid underground through DWC High Denisty Polyethylene Pipe having courragation on Outer walls and Plain surface inner walls Conforming to IS: 14930 part-1 and 2 Complete with accessories for Protection of 1.1 KV gade under Ground cable Directly in Ground at a depth of 50 CM including excavation and Refilling the trench. ( material to be appeoved before execution.) |
| 108 | Supply/ Installation/ Testing and Commissioning of CPRI Approved (IS/IEC 61439) Main Controlling Pnel Fabricated out of heavy gauge sheet dully Painted with Powder Coated Paint, Dust Proteted, earth Terminal Fitted on epoxy cleats, Volt Meter & Ammeters with Panel on both heating and Lighting circuits. The Switchs are Connected with Bus Bar inside Panel & manufacturor CPRI Certified. The Switches are Adjustable Type made of Havells/ L&T/ ABB/ Legrand/ Siemens Make and Change Over Switch Should be of havells/ L&T/ Legrand/ Schneider make. (1) Normal Incomer a) 160 Amp + Pole, 55K AC C-CURVE MCCB with extended termnals Havells/ L&T/ ABB/ Legrand Siemens make ad Approved =01 NO b)600 Amps TPN AI Bus Bar set = 01 Set, Digital Voltmeter.Ammeter, C. T. Coils with Selector Switch & Phase indicator set, (2) OutGoing (i) Normal Outgoing for Heating / AC / Lighting/ Inverter etc Load a) 40 - A mp DP MCB = 04 NO for Lightinh/ Machine Circuits. b) 32 - A mp DP MCB = 04 NO for Invertor Circuits. c) 63 - A mp DP MCB - 04 NO for Heating Circuits. |
| 109 | Environmentally Safe maintenance Free Copper Rod earthing System Necessary soil Treatment is to be made by the conyractor in order to improve the pit resistance Value Supplying, installation and Testing of 75 mm Copper Pipe Filled with Ceytallineconductive Mixture with ECO Friendly GEM backfill Compound 2 NO. Bags also having earth pit Chamber (300x300) mm with main Hole Cover for the above, including Cost of 20 mm wode Copper Strip as required in one Run Fitted with of brass nut Bolts and Spring washer from Earthing Rod up to Main Control Paneel, thruogh DWC High Density Poly ethyene Pipe having Corrugation Complete Job |
| 110 | Supply and Fixing of PVC Ceilling Rose (2/3 Pin), ASA marked, Suitable for connection of Light, fan Point, Complete with necessary Accessories. Including Connections and Testing as required of havells/ Anchor/ Legrand/ Eq. Make |
| 111 | Supply and Fixing of Hylum Sheet (Phenolic Lanimated Sheets), 3 mm/ 6 mm/ 10 mm thick (as Specified) Dully Cut to Required size ans Shape, Fixed with necessary nuts Bolts, Secrews, washers, Spacers etc, Including Filling and making Good the Surface Complete as Required. Please Enable Macros to View BoQ information |