| 1 | SCHEDULE 'A' PART-I (Building/Structure Works) is not prepriced by MES and prepriced rates indicated 0.00 under column 5 signifies this fact only. |
| 2 | Design and Construction of Married Accommodation for 06 JCOs (Ground+02) with permanent specification, RCC framed construc-tion , ATT, Mosquito proofing, Seismic measures etc. complete all as specified, directed and shown on drawings. |
| 3 | Design and Construction of Married Accommodation for 04 JCOs (Ground+01) with permanent specification, RCC framed construc-tion , ATT, Mosquito proofing, Seismic measures etc. complete all as specified, directed and shown on drawings |
| 4 | Design and Construction of garrage for 16 JCOs with permanent speci-fication, RCC framed construction , ATT, Mosquito proofing, Seismic measures etc. complete all as per drawings & as directed. complete all as specified and shown on drawings |
| 5 | NOTE: Schedule 'A' Part II to XI under Ser No 2.01 to 2.10 are Prepriced by MES. |
| 6 | Total amount of Sch 'A' Part II (Site clearance, excavation and earth work) |
| 7 | Total amount of Sch 'A' Part III (Internal Water Supply) |
| 8 | Total amount of Sch 'A' Part IV (Internal Electric Supply) |
| 9 | Total amount of Sch 'A' Part V (Road Path and culvert) |
| 10 | Total amount of Sch 'A' Part VI (Sewage Disposal) |
| 11 | Total amount of Sch 'A' Part VII (Area Drainage) |
| 12 | Total amount of Sch 'A' Part VIII (Chain Link Fencing) |
| 13 | Total amount of Sch 'A' Part IX (Rain Water Harvesting / Recharge Pit ) |
| 14 | Total amount of Sch 'A' Part X (External Water Supply) |
| 15 | Total amount of Sch 'A' Part XI (External Electrification) |
| 16 | Sch 'A' Part - XII (Miscellaneous Items for B/R & E/M Works)Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as \\"Rs 0.00 under col.5 siginifies this fact only. |
| 17 | (Internal Electrification)M & L for point wiring one Light/Ceiling fan/Exhaust fan controlled by one switch with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified & directed . Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. at no extra cost. |
| 18 | M & L for point wiring one LED light point controlled by two 2 - way switches with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified & directed. Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. at no extra cost. |
| 19 | M & L for point wiring one Bell point controlled by one bell push switch 6 Amp 240 V with 1.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified & directed . Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. at no extra cost. |
| 20 | M & L for point wiring one 3 pin switch socket oulet 5 Amps on the independent board with 2.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade, in and including PVC conduit medium duty (ISI marked) not less than 20 mm dia with accessories such as bends, cross, elbow, tees etc. of suitable size including MS pressed steel cadmium plated terminal box not less than 1.6 mm thick for mounting switches, sockets, fan regulators etc and 3 mm thick laminated sheet top cover(ISI marked) including continuous earth wire FRLSH PVC insulated unsheathed 1.5 Sq mm(nominal area) copper multistarnded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified & directed . Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. at no extra cost. |
| 21 | M & L for point wiring with 2.5 sqmm (Nominal Area) FRLS PVC insulated un sheathed multi stranded copper conductor, 1100 Volts grade for 3 Pin socket outlet 15 Amps on independent board with PVC conduit (ISI Marked) medium duty not less than 20mm dia with accessories such as elbow, tees,internal & external bend etc. of suitable size including MS pressed steel cadmium plated terminal box of 1.6 mm thick for mounting switch socket combination and 3 mm thick ISI marked laminated sheet top cover including continuous earth wire FRLS PVC insulated 1.5 Sq mm copper multi stranded conductor, 1100 Volts grade, connecting to common earth and earth dolly complete all as specified and directed. Note : Wiring Color code i.e. Red for Phase, Black for neutral and Green for earth shall be maintained. |
| 22 | S & F 20 Watt LED batten light surface / wall mounted with specially designed powder coated aluminium housing having IP66 protection, high optically efficient polycarbonet diffuser, in built electronic driver duly wired upto terminal block including fixing/hanging arrengement complete all as specified & directed . |
| 23 | S & F 10 Watt LED batten light surface / wall mounted with specially designed powder coated aluminium housing having IP66 protection, high optically efficient polycarbonet diffuser, in built electronic driver duly wired upto terminal block including fixing/hanging arrengement complete all as specified & directed . |
| 24 | S & F LED Building security Light fitting 35 W 230V AC outdoor type with high pressure die cast aluminium housing & heat resistant complete with driver, Lamp bracket with impact and corroson resistant incl thermal management in multiple optics complete with IP-66 protection complete all as specified & directed . |
| 25 | S & F 10 Watt Bulkhead luminaries incl LED light driver holder connecting up with 3 core flexible copper conductor cable of suitable size with inbuilt electronic driver duly wired upto terminal block & fixing arrangments for fixing the light fitting complete all as specified & directed. |
| 26 | S & F BLDC type Ceiling Fan 1200mm sweep single phase 230V AC, min 220 CFM with five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose complete accessories and connecting up the Fan to ceiling rose incl PVC insulated 3 core 23/0.0076 copper cable & suitable size of flexible conduit from ceiling rose to ceiling fan motor not less than 0.5 m long for connection complete all as specified. Note:- (i) Necessary Fan hook deemed to be included in item rate. (ii) Fan will be operated by regulator neither remote. |
| 27 | S & F Exhaust Fan made of strudy engineering plastic body complete with louver shutter voltage 230V 50 Hz 1200 RPM copper winding of sweep 300mm, fixing the frame on the exhaust side of the wall (Inner/Outer surface of wall & cutting with and incl PVC insulated 3 core 23/0.0076 copper cable and suitable size of flexible conduit pipe from ceiling rose to Exhaust fan motor complete all as specified & directed. |
| 28 | S & F Exhaust Fan made of strudy engineering plastic body complete with louver shutter voltage 230V 50 Hz 1200 RPM copper winding of sweep 250mm, fixing the frame on the exhaust side of the wall (Inner/Outer surface of wall & cutting with and incl PVC insulated 3 core 23/0.0076 copper cable and suitable size of flexible conduit pipe from ceiling rose to Exhaust fan motor complete all as specified & directed. |
| 29 | S & F MCCB VTPN DB 4 - Way sheet metal enclosure 415V with 200 Amp fully insulated strandard copper Busbar for wach phase & sourrounded with Neutral bars & two cpmmon neutral Bars, two earth bar incl cable ties for cable management suitable for housing MCCB/TPN 415V as incomer IP-54 protection with metal door all enclosed on strandard steel sheet flush mounted type double door factory favricated complete without MCB & MCCB but with enclosure blank plate complete all as specified & directed. Note:- Independent GI pipe incl connected items of suitable size will be laid in concealed in wall for each floor for XLPE cable 16/25 sqmm 4 core cable connection. |
| 30 | S & F MCCB 415V, 16 KA 4 pole AC, with 100 Amps rated busbar of suitable size plate and common neutral link all enclosed in standard steel shett flush mounting type factory fabricated, powder coated with complete wiring all as specified & directed. |
| 31 | M & L for Sub main wiring with 2 x 4 sqmm copper conductor and FRLSH, PVC insulated, multistrandard unsheathed cable ISI marked drawn in PVC conduit not less than 25mm dia medium grade ISI marked concealed in wall surface / ceiling for sub main connection incl 4 sqmm PVC insulated, multistrandard unsheathed copper conductor and connected to common earth dolly complete as specified. Note :-(i) Two single core 4 sqmm copper conductor for (Phase & Neutral) and One run of PVC conduit and One run of 4 sqmm earth wire shall be measured and paid as one unit. |
| 32 | M & L for Sub main wiring with Two single core 6 sqmm copper conductor and FRLSH, PVC insulated, multistrandard unsheathed cable ISI marked drawn in PVC conduit not less than 32mm dia medium grade ISI marked concealed in wall surface / ceiling for sub main connection incl 6 sqmm PVC insulated, multistrandard unsheathed copper conductor and connected to common earth dolly complete as specified. Note :-(i) Two single core 6 sqmm copper conductor for (Phase & Neutral) and One run of PVC conduit and One run of 6 sqmm earth wire shall be measured and paid as one unit. |
| 33 | M & L Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (Earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised earth lead wire 4.0 mm dia as earth lead upto 7.5 mtr long connected by means of bolts, check nuts and washers of GI and earth wire protected by provn of GI pipe medium grade, 15mm bore incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 40 X 40 X 3 mm fixing with 6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated as buttom 1.75 mtr long palced on top edge plate, common salt and charcoal filling, with fixing arrangement, funnel, wire mesh and earth work in hard / dense soil, returning filling in and removal of suplus soil to a distance not exceeding 50mtr, all as per elctrical plate no3 3 of SSR 2009 Prt - I and connection all as specified & testing on complition. NOTE: The cost of excavation & earth wotk, PCC pit and pit covers, funnel and watering pipe, wire mesh, charcoal dust, salt, 20/40mm dia med grade GI pipe as protection to GI wire 4.0 mm as main earthing lead from earth electrode to main DB Box test point length not less than 7.5 mtr) shall be deemed included in the unit rate for earthing & testing complete all as specified & directed. |
| 34 | Supply and fix water heater storage type, electric,Capacity 25 Liters BEE 5 star rated complete all as specified and directed. |
| 35 | Supply and fix PVC connection heavy wire strengthed of size 15 mm dia 450 mm long with 02 Nos brass nutes and washers at both end for connecting geyser completed all as specified and directed. |
| 36 | Screwing existing steel bubing for alteration or additions (or lengthening screw on pipe to form connectior complete all as specified and directed. |
| 37 | Supply and fix Angle valve of size 20mm dia complete all as specified and directed. |
| 38 | External Water Supply Material and labour for Brick Masonry valv pit chamber 900 x 900x 900(internal dimention) including PCC, Brick work and MS steel cover 3mmm thick,MS angle iron frame size 40mmx40mmx6mm around of valve pit. locking arrangment with pad lock size 50mm dia brass,6 lever with duplicate key (make godrej) and painting all steel surface with two coats of synthetic enamel paint over a coat of red oxide primer all complete. |
| 39 | S&F Sluice valve for 110 MM outer dia PPR pipe OF CLASS pn 1.6 all as specified and directed. |
| 40 | Cutting /lapping of CI/DI/PPR pipe line of size 150/100 for inserting the tee/plug in main pipe line for 110 mm bore PPR pipe complete. |
| 41 | External Electric SupplySupply,installation and testing of factory made,CPRI Approved cubical outdoor (Kiosk) type feeder pillar box 415 volt, 4 wire, AC 50 Hz, made out of 3.15 mm thick CRCA sheet ,weather and vermin proof powder coating finish both side(interior & exterior) for outdoor mounting with having degree of protection as per IP-56 complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link,Both Side openable double door Indicating light LED type RYB - 01 Set,Ammeter-01, Voltmeter-01, connecting strip/solid conductor brought out to cable chamber brass/copper nut, bolts/washer etc including grouting of feeder pillar box 60 cm above ground level including suitable size angle iron stand made up of 65 x 65 x 6 mm welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto 30 cm including excavation and earth work complete with following asseccories :-(a) copper insulated busbar high conductivity 400 Amp rated 4 phase including neutral bus bar complete - 01 No.Incoming :-(b) MCCB 4 -pole 250 Amp make-L & T ,415 Volt,breaking capacity 36 KA,50 HZ with thermal magnetic release - 01 No.Outgoing :-(c) MCCB 4 - pole 100 Amps breaking capacity 25 KA, 50 HZ - 05 Nos. |
| 42 | Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink outdoor type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 120 sqmm to 185 sqmm insulated armoured aluminium cable complete all as specified and directed. |
| 43 | Supply, jointing and testing cable jointing kit for 1100 volt grade cable for cable end termination heat shrink outdoor type joint complete with jointing material & accessories for 3.5 core XLPE cable of size 50 sqmm to 95 sqmm insulated armoured aluminium cable complete all as specified and directed. |
| 44 | Spreading of natural, clean and dry river sand in trenches for cable protection, complete all as specified and directed.NOTE:- Punned thickness shall only be measured and paid. |
| 45 | M&L for earthing complete with galvanised steel earth plate 600 x 600 x 6.3mm burried directly in ground (Earth pit not less than 2.25 m deep) with top edge of the plate not less than 1.5 m below ground level connected to GI strip of size 32 x 6 mm by means of nuts, bolts & washers,earth wire protected by GI pipe 40 mm dia ‘light grade’ ISI marked including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate),40 mm thick precast RCC cover in 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe ‘light grade’ ISI marked, 20 mm bore all as shown in Electrical plate No. 03 of MES Schedule Part-1 (2009) complete complete all as specified and directed. |
| 46 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4mm galvanised iron strip all as specified and directed. |
| 47 | Rain Water harvesting/Recharge PitSupply and filling Coarse sand/Pea gravel filling and leveling complete all as specified in drg. |
| 48 | Supply and levelling coarse aggregates, granite trap or basalt grading l, 100 to 50 mm size and leveling complete all as specified in drg. |
| 49 | Material and labour for Drilling 250 mm dia bore with drill/reverse rotary rig circulation method including electronic logging through in any kind of soil strata from ground level up to 25m depth in any strata including Development of tube well with compressed air after with 25% extra capacity pump by pumping muddy water excavated material /soil exc 5km but no exc 10km and depositing outside of MOD land where directed complete all as specified and as directed . |
| 50 | Material and labour for Drilling 250 mm dia bore with drill/reverse rotary rig circulation method including electronic logging through in any kind of soil strata from ground level depth exceeding 25m and not exceeding 75 m in any strata including Development of tube well with compressed air after with 25% extra capacity pump by pumping muddy water excavated material /soil exc 5km but no exc 10km and depositing outside of MOD land where directed complete all as specified and as directed . |
| 51 | Material and labour for Drilling 250 mm dia bore with drill/reverse rotary rig circulation method including electronic logging through in any kind of soil strata from ground level depth exceeding 50m and not exceeding 50m in any strata including Development of tube well with compressed air after with 25% extra capacity pump by pumping muddy water excavated material /soil exc 5km but no exc 10km and depositing outside of MOD land where directed complete all as specified and as directed . |
| 52 | S& F 150 mm dia of CPVC peforated pipe & fittings any grade in trenches |
| 53 | S& F 250mm dia of CPVC pipe & fittings any grade in trenches |
| 54 | S& F 250 mm dia of CPVC peforated pipe & fittings any grade in trenches Please Enable Macros to View BoQ information |