| 1 | Dismantling of asbetos/fibre cement corrugated/semi corrugated sheet in roof covering including ‘J’ or ‘L’hooks complete all as specified and directed. |
| 2 | Dismantling framed trusses n exc 10m complete all as specified and directed. |
| 3 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. |
| 4 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed by Engr-in-Charge. |
| 5 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed. |
| 6 | Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified and directed. |
| 7 | M&L Brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed. |
| 8 | M&L for RCC 1:2:4 using 12.5 graded stone aggregates as in beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 9 | M&L TMT bars 8mm dia and over cut to length bent to shape required incl cranking bending, spirally , hooking ends and binding with mild steel wire not less than 0.9mm dia (annealed) complete all as specified and as directed by Engineer-in-Charge. (Note : The payment shall be made only after placing of cover on manholes) |
| 10 | M&L Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22.5cm and n exc 100cm long of 20mm dia incl all complete all as specified and directed. |
| 11 | M&L Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 12 | S&F roof trusses (framed),Fe 410-W (Gde E-250) quality A trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats , etc. complete all as specified and directed. |
| 13 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. |
| 14 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick having tensile strength of 550Mpa as in ridges fixed with self tapping screws complete all as specified and directed.Note : Fixing of sheets will be done strictly according as per manufacurer's instructions. |
| 15 | M&L factory made Steel Window Box type factory made using ERW 'P' Section comprising Double Frame for Gauged and Glazed Skeleton Shutter jointed internally with Flat Iron 40x3mm complete including Mild Steel Tower Bolts, Hinges, Handle, Stops, Lugs including GI Steel Wire Cloth (0.36mm) aperture, Glazing/ Glass(3mm), etc. incluidng painting two coat over a coat of primer complete all as directed. Outer Section of Frame should be 50x25mm and Inner Section should be 40x20mm, complete all as specified and as directed.NOTE :-(a) For the purpose of Measurement & Payment Double Shutter with Frame shall be considered as One Unit.(b) Cost of Iron Mongery as ordered/required at Site, GI Steel Wire Cloth will deem to be included in the Quoted Unit Rate.(c) Guard Bars are included in the Quoted Unit Rate. Spacing of 10mm Square Bar will be 10 Cm Centre to Centre. |
| 16 | S&F factory made Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified,size 125x60mm |
| 17 | M&L PCC (1:3:6 ) type C 0 using 12.50 mm graded aggregate as infilling in PS Chowkhats alll as specified . |
| 18 | S&F factory made ISI marked flush door shutters 30mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood incl two coat of synthetic enamel painting over a coat of pink primer complete all as specified and incl supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 3 Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 150mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 150mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf |
| 19 | S&F factory made 30mm thick glazed and skelton shutters of 2nd class hard wood open rebated and divided to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR-91 Pt-1 section 8 clause 8.20(a), kiln seasoned and chemically pressure treated all as specified including stainless steel 304 Grade wire cloth (0.36mm nominal dia of wire and average width of aperture 1.40mm) incl two coat of synthetic enamel painting over a coat of pink primer complete all as specified and including supply and fixing following items :(a) Stainless Steel (304 Grade) Finished Butt Hinges 100mm - 3Nos per leaf(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16x300mm - 1 No per leaf |
| 20 | M&L 300mm ordinary Rat tail rod pattern springs including roller and roller plate complete as directed by Engr-in-Charge. |
| 21 | M & L for preparing steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge. |
| 22 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed. |
| 23 | M&L rendering 15 mm thick on fair faces of brick walls or concrete surfaces in CM 1:4 finished even and smooth without using extra cement, including mixing of liquid water proofing compound, complete all as specified and directed.(Note: WPC will be measured and paid separately) |
| 24 | M&L Supply only Liquid water proofing compound complete all as specified and directed. |
| 25 | M&L Rendering 10 mm thick in cement mortar 1:6, on brick or concrete surfaces, trowelled to even and fair finish without using extra cement complete all as specified and directed. |
| 26 | M&L 75mm broken brick hardcore of gauge n. exc 63mm , deposited , spread and levelled in layers n. exc 15cm thick , watered and rammed to atrue surface complete all as specified and directed. |
| 27 | M&L 75mm thick, PCC 1:4:8, type D-2 (using 40mm graded stone aggregate), as in sub base complete all as specified and directed . |
| 28 | M&L Machine cut Kota stone slab flooring 16-18 mm thick, for staircase step in single piece (of length not more than 1200 mm), laid over over & including 15 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete, including provn of two Nos 3x3mm grooves at tread of each step complete all as specified and directed. |
| 29 | M&L Machine Cut Kota stone slab 16-18 mm thick on vertical surfaces like riser of steps, skirting, in single piece (of length not more than 1200 mm) over & including 10 mm thick (average thickness) cement mortar (1:3) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (Mirror finish), complete all as specified and directed. |
| 30 | S&F in repair Poly coated GI Frame work as in grid for False ceiling comprising of protected GI perimeter channel 0.55 mm thick with two uneual flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon selves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having to equal flanges of 15 mm each and web of 45 mm suspended from soffit and approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and incl ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and hangers 6 mm dia GI (up to 1200 mm length adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x3 mm size 60 mm long complete with and incl 7 mm thick PVC laminated gypsum tiles of size 595x595 mm of approved design of make Acoster/Ploca/Armstrong or equivalent as approved by GE all as specified and directed. |
| 31 | M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints and form work complete all as directed by Engr-in-Charge and complete as specified. |
| 32 | S&F MS hollow rectangular/square tubes/pipes of YST 310 Grade as in frame work for roofs/sheds/chajjas etc and like similar items including welding/fixed with conn plates etc. including one coat of red oxide zinc chrome primer complete all as specified. |
| 33 | M&L for ACP sheet of 3mm thickness of approved plain colour/shade for chajjas/ shade for chajjas / sunshedes / cladding and the like works etc. fixed to frame work of MS/aluminium/hollow sections of any size description including finishing all the joints with silicon or as per manufacturers instructions complete in all respect and complete fixed in position incl scaffolding/ladders etc as required and also making the joint between all as specified and directed. Note : Frame work shall be measured and paid separately. |
| 34 | M&L Machine pressed precast concrete inter locking paver block any shape and size made of M-35 grade concrete (with grey cement and no pigment) of 60 mm thickness with 6mm top layer of anti abrasive material laid over 25mm thick (compacted) fine sieved sand filling complete all as specified and directed. |
| 35 | M&L factory made coloured chequered tiles 30cm x 30cm x 25mm thcik with grey cement and pigment, set jointed and pointed in neat cement slurry as in floor/path complete all as specified and directed. |
| 36 | M&L complete removal of existing treatment on plastered surface and applying two coats of distemper on wall over a coat of primer incl preparation and applying a coat of wall care putty of surface complete all as specified and directed. |
| 37 | M&L Preparation of new plastered surfaces and applying two coats of distemper incl a coat of wall care putty incl primer complete all as specified and directed. |
| 38 | M&L for preparation of new plaster surfaces and applying two coat of cement base paint complete all as specified and directed. |
| 39 | M&L Preparation of old plastered surfaces and applying one coats of cement base paint of any approved shade, by using roller/brush to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including complete all as specified and directed. |
| 40 | Taking down carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etc removing materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of credit and making good the disturbed portion of all floor, ceiling etc all as specified and directed. |
| 41 | M & L for Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor for one light/fan/bell point in and including NEW PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in pressed steel terminal boxes with PVC modular top cover plates of suitable size for mounting of modular type switches/sockets/regulators including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including cutting chases and making good the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed by Engr-in-charge.Notes: (i) Cost of Pressed steel Terminal Boxes and modular Top cover plate shall be included in point wiring. (ii) Wiring shall be done as per colour code in IS for phase, neutral and earth.(iii) -Cost of Eye/bottle thimbles used for connection in switches/sockets & MCBs in DBs shall deemed to be included in the unit rate quoted for this item. |
| 42 | All as per Sl item No 41.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. |
| 43 | All as per Sl item No 41.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. |
| 44 | All as per item No.41.00 herein before but 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSH copper earth wire for switch socket combination 3 pin 15 amps on independent board. |
| 45 | S & F in replacement of Modular switch 1 way, 6 Amps, 1 module, 230 volts complete all as specified. |
| 46 | S & F in replacement of Modular switch 1 way, 16 Amps, 1 module, 230 volts complete all as specified. |
| 47 | S & F in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. |
| 48 | S & F in replacement of Modular socket 5 pin 6 &16 Amps, combination type 2 module complete all as specified. |
| 49 | S & F in replacement of Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. |
| 50 | S & F in replacement of ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed |
| 51 | Supply and fix surface/recess mounted LED luminaire 36 watt cool white 4000-5000K suitable for gridd celling cutout dimensions: 2x2 Ft. incl connecting with twin core copper wire from ceiling rose to fitting, Fixture size: (LxWxH) in (595x595x65) mm incl lamp and driver all as specified & directed. |
| 52 | S & F in replacement of New generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. |
| 53 | S & F in replacement of Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge. |
| 54 | Supply and Fix Lamp holder including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed by Engr-in-charge. |
| 55 | M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqmm Copper conductor Earth wire shall be measured as one unit) Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. (ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc. 10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring. |
| 56 | S & F in replacement of Sheet metal enclosure DB TPN 4 ways double door 415 volts with 200 Amps standard bus bar of suitable size and common neutral link flush mounting type, drilling holes for incoming and out going cables complete with IP-43 protection complete all as specified and directed by Engr-in-charge |
| 57 | S & F in replacement of MCB, TRIPLE pole & neutral (TPN) 10 KA 240 volts 40 to 63 Amp capacity fixing in DB’s complete all as specified and directed. (Note: MCB should be B curve as directed by engineer in charge) |
| 58 | Supply and fix in replacement of Sheet metal enclosure 8 ways double door for DBs when MCBs are to be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link all flush mounting type, drilling holes for incoming and out going cables with IP43 protection complete all as specified & directed by Engr-in-charge. |
| 59 | S & F in replacement of MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fix in replacement of MCB , SPN, 240 Volts ,40-63 amp for fixing in DBs of including proper thimble connections complete all as specified and directed by Engineer-in-Charge. |
| 61 | M & L in replacement of UNSV Earthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 all as specified and directed by Engr-in-charge. |
| 62 | S & F in replacement Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in square LED Batten 20W 6500K of capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. |
| 63 | XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core supplied & laid in replacement complete all as specified& directed by Engineer-in-Charge. |
| 64 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. |
| 65 | Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm each layer of any kind of soil. |
| 66 | Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point. |
| 67 | Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm above with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed. |
| 68 | Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete all as specified and directed. |
| 69 | Supplying & laying factory made unreinforced Precast concrete cable covers class LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables complete all as directed by Engr-in-Charge |
| 70 | Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. Please Enable Macros to View BoQ information |