| 1 | DSR Item No.1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 2 | 25 mm |
| 3 | DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | 3 x 1.5 sq. mm |
| 5 | 3 x 2.5 sq. mm |
| 6 | 4 x 1.5 sq. mm |
| 7 | 3 x 4 sq. mm |
| 8 | DSR Item No. 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 9 | Group B |
| 10 | DSR Item No. 1.11 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 11 | DSR item No.1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 12 | DSR item No.1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 13 | DSR item No.1.57 Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 14 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 15 | 5/6 amps switch |
| 16 | 2 way 5/6 A. switch |
| 17 | 3 Pin 5/6 A. socket outlet |
| 18 | Telephone socket outlet |
| 19 | Bell push |
| 20 | DSR item No.1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 21 | 2 Pair |
| 22 | DSR item No.1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 23 | DSR item no.8.9.5 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, (As per Complete Item No. 11 of the DNIT) |
| 24 | 18- 22 watt |
| 25 | DSR item no. 8.13.7LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, (As per Complete Item No. 12 of the DNIT) |
| 26 | 25 Watt |
| 27 | DSR item no.8.16.2LED Flood powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, (As per Complete Item No. 13 of the DNIT) |
| 28 | 100 Watt |
| 29 | Supply & erection of fresh air fan high speed motor with copper wound 10” sweep with louver and plastic body complete with high speed motor, blades, epoxy powder coated of Havells make Ventiliar DX White / Orient make Ventilator / Crompton make Brisk Air/ Bajaj make 70049 250mm sweep only. (As per Complete Item No. 14 of the DNIT) |
| 30 | DSR item No.9.2Brush Less Direct Current (BLDC) Fan without RemoteSupply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, (As per Complete Item No. 15 of the DNIT) |
| 31 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 32 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 33 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, (As per Complete Item No. 16 of the DNIT) |
| 34 | Size 12” Sweep 900 RPM with louver of Havells make Turbo Force SP / Orient make Industrial Heavy Duty / Crompton make EXHD 380-6-1/ Bajaj make Supreme PLUS/ Usha make Turbo HDEF only. |
| 35 | S/E of 90 cm. long electric chimney including 6 inch. Internal dia flexible alum. Pipe. The aluminum pipe shall be covered with PVC cap at end side or outer side. The length of pipe as per site requirement upto 3mtr long. (As per Complete Item No. 17 of the DNIT) |
| 36 | S/E of LED 8W/ 9 W. bollard fitting. The bollard should be approximately (800 mm long and 200 mm wide) from the top of the fitting. The bollard should be made out of extruded aluminium profile and die cast aluminium base with PMMA/ Opal diffuser bollard painted with superior quality of paint. (As per Complete Item No. 18 of the DNIT) |
| 37 | DSR item No.39.17.1 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, (As per Complete Item No. 19 of the DNIT) |
| 38 | 1 Run cable Please Enable Macros to View BoQ information |