Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | SCHEDULE \\"A\\" Part-I (Building/Structures) (To be quoted by the tenderer) |
| 2 | Item No 01 : Design and Construction of Office complex, classroom & bathroom complete all specified in soil bearing capacity report, design basis report, drawings and tender documents. |
| 3 | Sch 'A' Part-II (External Electric Supply) Lump sum price worked out by the contractor for (External Electric Supply) as listed in Schedule 'A' Part-II against the lump sum price inserted by the MES. |
| 4 | Sch 'A' Part-III (External Water Supply) Lump sum price worked out by the contractor for (External Water Supply) as listed in Schedule 'A' Part-III against the lump sum price inserted by the MES. |
| 5 | Sch 'A' Part-IV (Road, Path Curvert) Lump sum price worked out by the contractor for (Road, Path Curvert) as listed in Schedule 'A' Part-IV against the lump sum price inserted by the MES. |
| 6 | Sch 'A' Part-V (Sewage Disposal) Lump sum price worked out by the contractor for (Sewage Disposal) as listed in Schedule 'A' Part-V against the lump sum price inserted by the MES. |
| 7 | Sch 'A' Part-VI (Area Drainage) Lump sum price worked out by the contractor for (Area Drainage) as listed in Schedule 'A' Part-VI against the lump sum price inserted by the MES. |
| 8 | Sch 'A' Part-VII (Site Clearance) Lump sum price worked out by the contractor for (Site Clearance) as listed in Schedule 'A' Part-I against the lump sum price inserted by the MES. |
| 9 | Sch 'A' Part-VIII (Lighting Protection System) Lump sum price worked out by the contractor for (Lighting Protection System) as listed in Schedule 'A' Part-VIII against the lump sum price inserted by the MES. |
| 10 | Sch 'A' Part-IX (Cooling Appliances) Lump sum price worked out by the contractor for (Cooling Appliances) as listed in Schedule 'A' Part-IX against the lump sum price inserted by the MES. |
| 11 | Sch 'A' Part-X (Internal Electric Supply) Lump sum price worked out by the contractor for (Internal Electric Supply) as listed in Schedule 'A' Part-X against the lump sum price inserted by the MES. |
| 12 | Sch 'A' Part-XI (Internal Water Supply) Lump sum price worked out by the contractor for (Internal Water Supply) as listed in Schedule 'A' Part-XI against the lump sum price inserted by the MES. |
| 13 | Note for Srl No 2 to 12The percentage above / below the SSR -2020 (part-II) rates shall be derived from the amount quoted by the contractor against Srl No. 2 to 12 by comparing it with the amount inserted / pre- priced by the department and the same shall be applicable for the items of respective schedule |
| 14 | Schedule 'A' Part-XII (Miscellaneous items of works) |
| 15 | External Electric Supply |
| 16 | Item No 02 : M& L for cable Route indicator MS sheet embossed with LT 1100 Volts Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 17 | Item No 03 : M& L for cable Route indicator MS sheet embossed with HT 11000 Volts UG made with CI Plate 6 mm thick fixed with MS angle Iron of size 30x30x4mm of length 400 mm long including PCC work 1:2:4 type B1 of size 150x150x150 mm complete all as specified & directed |
| 18 | Item No 04 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 19 | BUSBAR :- (i) 300 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 20 | INCOMING |
| 21 | (a) MCCB 4 Pole 160 Amps, 36 KA with Rotary Handle, 01 No (incoming) |
| 22 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 23 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 24 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 25 | (e) Copper wound with rated CTR |
| 26 | OUTGOING |
| 27 | (i) MCCB 4 Pole 125 Amps,25 KA at 415 volts - 02 No.(1 No Trg Cell + 1 No Standby) |
| 28 | (ii) MCB 4 P 63 Amps,16 KA 415 volts - 01 Nos (Centralised Cooler) |
| 29 | (ii) MCB 3 P 40 Amps, 16 KA 415 volts - 02 Nos (Post top lantern Light & LED bollard light) |
| 30 | (iii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 31 | (iv) Auto control time switch, timer control for different 24 hours adjustable type including power contractor of rated capacity complete - 01 Nos (1 x Garden Light) |
| 32 | Item No 05 : S & F Integral decorative LED bollard with IP 65/66 protection suitable for 10 watts LED with necessary elecrical connections with adequate size of Nuts and Bolts complete as all specified and as directed. |
| 33 | Item No 06 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 34 | Item No 07 : Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25 X 4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 35 | Item No 08 : S&F earth continuity conductor or main earth lead of 32 X 6 mm GI strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 36 | Item No 09 : S&F earth continuity conductor or main earth lead of 25 X 3.15 mm aluminium strip with saddles and fixing screw etc for roof conductor and down conductor fixed to wall on batten or recess or ground for connecting earthing to various equipments as required complete all as directed. |
| 37 | Item No 10 : Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 155 x 210 x 92 mm,having terminals for termination of cable with necessary nuts and bolts, including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete all as directed. |
| 38 | Item No 11 : Material and labour for LT 1100 volts (Earthed) grade heat shrinkable end termination jointing kit indoor type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 sqmm complete all as specified and as directed. |
| 39 | Item No 12 : Material and labour for preparation of new steel surfaces of any description over 10 cm width or girth and applying one coats of black bituminous paint complete all as specified and as directed. |
| 40 | Cooling Appliances |
| 41 | Item No 13 : Supply and fixing of ducted cooler top/down discharge - 03 Nos/Floor nominal air delivery of 25000 CMH per unit (total 6 units X 25000 CMH),1.5 KW Motor power,cooling capacity upto 1600 sq ft per unit of duct cooler UV Stablized High Grade Plastic of Tank capacity 70 litres Fan Dia 620 mm with Honeycomb pads of thickness 100 mm with 80 % minimum cooling efficiency,with 3 phase starter ,hanger hook and L shaped bracket including supply ,Installation ,commissioning and balancing of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. Duct with 1:3 Ratio of 22G 0.7 mm and 24G 0.6 mm sheet from machine to ceiling height and ceiling to the alumium grills should rectangular shape ducting complete with neoprene rubber gaskets,nitrile rubber acoustic insulation of size 19 mm (inside) ,thermal insulation of size 6 mm (outside ), elbows, splitter damper vanes,hangars,supports |
| 42 | .Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Powder coated alumium Grill and Volume control damper should be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve .The steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. |
| 43 | All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets.Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried out as per approved drawings and specifications of following sheet thickness complete all as specifed and as directed.Note: (i) The duct work shall be as per IS 655.(ii) The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277 all as specified and directed |
| 44 | (ii) Drawings required for centralized air cooling system along with GTP should be prior approved by GE before procurement of material.(iii) Total area to be air 700 sqm (GF+FF). any minor variation in duct cooler units as per OEM is acceptable only after approval of GE.(iv) Rate are exclusive of required water supply pipeline and electric supply cable tapping from relevant locations. The same will be paid through respective item of the schedules |
| 45 | Item No 14 : Supply, installing, testing and commissioning out door type LT Panel of suitable size, Floor mounted, CPRI approved factory made totally enclosed, dust and vermin proof, shutter in front and in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and external surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in : - |
| 46 | BUSBAR :- (i) 300 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round) insulators of suitable size and good insulation resistance |
| 47 | INCOMING :- |
| 48 | (a) MCCB 4 Pole 63 Amps, 16 KA with Rotary Handle -01 No |
| 49 | (b) Digital Voltmeter 3 Phase Class-1 50Hz - 01 No. |
| 50 | (c) Digital Ammeter 3 Phase Class-1 50Hz - 01 No. |
| 51 | (d) Indicator Lamps (LED type) & bakelite fuseshowing R,Y, G phase - 01 set |
| 52 | (f) Copper wound with rated CTR - 03 Nos |
| 53 | OUT GOING |
| 54 | (i) MCB 4 P 'C' Series 10 Amps, 415 volt - 06 Nos |
| 55 | (ii) Indicator Lamps (LED type) & bakelite fuse showing R,Y, B phase - 02 set |
| 56 | Item No 15 : Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA |
| 57 | Sewage Disposal |
| 58 | Item No 16 : Supplying and laying and jointing for (SN 8) DWCPE 180mm (OD)/ 163 (ID) mm diameter pipes laid on 150 mm thick bed with excavation in any type of soil, from 0.70 upto 1.65 m depth including manholes/ drop manhole of standard size made of Brick Masanary/RCC/ Precast RCC with SFRC venting cover and frame. Includes all items and activities to execute and make sewer line functional. As per IS-16098:2013 para A-4.1.2.4(a) any form of cement concrete structural bedding would not be necessary under normal conditions, even for maximum combined loading(Wheel load + backfill). |
| 59 | Item No 17 : M&L RCC Septic tank conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-25 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users. |
| 60 | Item No 18 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.40 M x 3.0 M depth complete |
| 61 | External Water Supply |
| 62 | Item No 19 : M&L for tapping in existing GI pipe lines 100 mm dia and inserting tee and all as directed. |
| 63 | Item No 20 : Construction of brick masonry valve pit of size 1200 mm x 1200mm x 900 mm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick cement plaster in CM (1:4) internally and externally upto 15cm below ground level providing valve pit cover 40x40x6mm angle iron frame all-round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm incl provn of hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as shown on drawing and as specified. |
| 64 | Item No 21 : Supply and fix pressure sensor switch having ambient operating tem -40 to 65 degree celcius , differential pressure range 0.7 bar to 4 bar, regulation range 0.2 bar to 7.5 bar ISO STANDADARD 228-1 complete all as specified and as directed. |
| 65 | Internal Electric Supply |
| 66 | Item No 22 : S & F modular type TV Socket out let complete all as specified and as directed. |
| 67 | Item No 23 : S & F modular type LAN Socket RJ 45 with complete box |
| 68 | Item No 24 : S & F modular type Telephone socket RJ 11/12 with complete box |
| 69 | Item No 25 : S & F for sheet metal enclosure DB VTPN 4 way vertical type incomming MCCB 4 pole -01 Nos and out going MCBs with 200 Amps rated bus bar 415 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Note :-MCCB and MCBs measured and paid separtely rate of dummy plate shall be deemed to be included in unit rate of item. |
| 70 | Item No 26 : M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and 15 mm dia GI pipe for protection of GI wire up to 7.5 mtr connected to earthing point complete all as specified and as directed. |
| 71 | Lighting Protection System |
| 72 | Item No 27 : S & F porceliene insulators 15 BMD type T with nut bolts / screws for fixing of aluminium strips on roof including provn of PCC of size 10cmx10cmx10cm height etc to avoid leakage of roof complete all as specified and as directed. |
| 73 | Item No 28 : M & L for earthing complete with galvanized steel earth plate 600mmx 600mm x 6mm thick electrode earthing lead buried directly in ground vertically to a depth not less than 2.25M deep below ground level with top edge of the plate not less than 1.5mtr below normal ground level connected to and including galvanised iron strip 32x6mm by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & specified or indicated and testing on completion including excation/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg /Sqm), cast iron frame, funnel with wire mesh, GI watering pipe of 20 mm bore medium grade and lugs, with and including galvanised iron strip 32x6mm with GI protection pipe of 40mm medium grade 7.5 meter long, complete all as specified and as directed. |
| 74 | Item No 29 : S & F GI strips 32 x 6 mm laid under the ground upto 30 cm depth complete all as directed by Engr in charge Note: Earthwork is deemed to be included in unit rate of item. |
| 75 | Rain water Harvesting |
| 76 | Item No 30 : M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry and solid M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.60 M x 4.5 M depth (For recharge well) Please Enable Macros to View BoQ information Schedule 'A' Part-II (External Electric Supply) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 77 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,11000 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70 sqmm, 3 core conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed.Note:- Excavation, earth work, sand cushioning and cable protection shall be measured and paid separately. |
| 78 | Supply and laying or fixing or passing in trenches/ on pole/ through pipes,1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor conforming to IS 7908 / (PART-I) 1988 with the latest amendments including jointing materials such as cable glands & lugs etc and testing on completion all as directed etc of the under mentioned type and sizes :- (a) 3.5 core x 70 sqmm RM 120.0 648.15 77778.0 (b) 2 core x 6 sqmm (Garden lighting & Post top Lantern) RM 320.0 127.61 40835.2 (c) 4 Core X 25 Sqmm (Centralised Cooler) Rm 150.0 249.04 37356.0 (d) 4 Core X 4 Sqmm (Duct cooler) Rm 200.0 135.14 27028.0 |
| 79 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 80 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 81 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. |
| 82 | Supply and laying sand cushioning with dry and clean washed sand over and under the under ground cable in trenches, ducts for cable protection 150 mm below & 80 mm above the cable as protection of cable complete as specified & directed. Note : Punned thickness of sand shall be measured & paid. |
| 83 | Supplying and laying unreinforced precast concrete cable cover, class LV Type 2 flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 84 | Supplying and laying unreinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engr in charge. |
| 85 | Supply and fixing steel tubular swaged pole, type 410 SP 55 (Overall length 11.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coat of black bituminous throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminium paints over a coat of red oxide primer, including painting white & red alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint and writing numbering of poles with black paint on yellow background complete all as specified and as directed.(Note: Excavation and earth work and PCC shall be measured and paid separately under respective items) |
| 86 | M&L for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as specified and dircted. |
| 87 | M&L for GI tube light grade with all fitting laid in trenches of fixed to pole of size:- |
| 88 | (a) 50 mm Dia |
| 89 | (b) 80 mm Dia |
| 90 | M&L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in Coping concrete and pilasters, buttresses columns, posts etc complete all as specified & directed. |
| 91 | M&L for PCC 1:3:6 type D2 using 40 mm graded stone aggregate as in landings, cover slab, foundation, filling, mass concrete (for manholes etc) and similar work including necessary form work and minimum reinforcement as per relevant IS code and set in CM 1:6 complete all as specified and directed. |
| 92 | M&L for 40 mm graded broken stone aggregate for spreading/ loose filling in the substation or other places where directed including stacking materials in regular heap/ stack for measurement complete all as specified and directed. |
| 93 | S&F for lightning arrestor Expulsion type complete with all fittings, transmision/ distribution class , (RMs) discharge current 10 KA suitable for rated system voltage of 12 KV supply system with maximum continuous operating voltage (MCOV) not less than 7.65 KV (RMS) with highly non linear ceramic resistor made of Zinc oxide in hermetically sealed container and mounting on poles including all necessary bolts, nuts and washers and making electric connection and testing on completion complete all as specified and directed. |
| 94 | Supply, installation, testing and commissioning of copper wound (double wound), step down transformer of capacity 100 KVA (Level-3), plinth/ floor mounted, OUT DOOR TYPE and conforming to IS 1180:2014, AC 3 phase 50 Hz, ONAN with external cooling tubes/ radiators, having no load voltage ratio 11/0.433 KV corresponding to principal tapping, delta connected primary side (11KV HV side) and star connected on secondery side (433V LV side) in accordence with vector symbol Dyn-11 (Vector Group), manual type off load tap changing facility on HT side to vary secondary voltage from minus 10% to plus 5% in steps of 2.5%, continuous rating of capacity 100 KVA . The transformer shall be complete with all standard fittings and accessories, gauges, first fill of tranformer oil as per IS-335, ISI marked duly filtered & dehydrated etc. |
| 95 | Transformer shall be mounted on and including suitable platform of approx size 2.0Mx 2.0Mx 1.5M high (outer dimension) built with 150mm thick PCC 1:5:10 type E2 using 40mm graded stone aggregate as in foundation extending 150mm on both sides of wall, 350mm thick of brick masonary built in CM 1:6 using old size sub class 'B' bricks, brick masonary shall be 450mm below GL & 550mm above GL, exposed faces of brick work up to 15cm below normal ground level shall be plastered in CM 1:4 & flush in same mortar as the work proceeds on faces in contact with soil, floor shall be 150mm thick with RCC with TMT 16 mm type B-1 1:2:4 using 20mm garded stone aggregate, laid in bays over & including 100mm thick hardcore over approved earth filling, exposed plastered surfaces shall be given three coats of white wash including necessary excavation and earth work complete all as specified and directed. The unit rate of transfarmer shall also includes the cost of following accessories/ fittings :- |
| 96 | a) Externally hand operated off-circuit Tap switch with position indicator and locking device.(b) Conservator with oil gauge, filling hole with plug & drain hole with plug.(c) Under carriage with four plain rollers.(d) Oil filling hole cum air release plug - 01 No(e) Drain valve cum sampling valve - 01 No(f) Filter valve with plug - 01 No(g) Rating plate & Diagram plate - 01 No(h) Lifting lugs for Transformer - 02 Nos(j) Lifting lugs for lid - 02 Nos(k) Earthling terminals - 02 Nos(l) Thermometer pocket - 01 No Silica gel breather - 01 No(n) Temperature rise indicator in oil 40 deg centigrade and windings 45 deg centigrade.(o) Fitting accessories as per IS 1180 (Part-I) 2014 Level-3 and as per clause No 19.14.1.2 of SSR Part I.(p) Maximum losses of transformer shall be energy efficiency level 3 as per IS 1180 (Part-I) 2014. (q) Oil level gauge incl oil level min and max. (r) Exclusion vent – 01 No.(s) 6” Dial type thermometer with alarm and trip contact and maximum temp – 01 No.(t) Mounting arrangement shall be provided with two 75x40 mm channels 460mm long.u) Suitable plinth of height 1.5M above GL for installation of transformer.(v) Cable termination box on both sides (HV Side & LV Side for cable connections ).(w) Plinth required for mounting Transformer as per above description. Note : (i) The contractor shall provide BEE certified, Level 3, Transformer offered by the Manufacturer.(ii) The contractor shall submit preliminary drawing for approval to GE . |
| 97 | Supply and fixing of switch air break gang operated triple pole mechanically operated horizontal type out door with all other fittings/ accessories mounted on & including porcelain insulators and steel frame with operating mechanism worked from ground level with & including operating rod of 32mm dia GI pipe medium grade (ISI marked) with MS handle with locking arrangement, for current rating up to 400 Amp 11000 Volts including dropout fuse set 15 insulators to suit gang operated triple pole 11 KV switch, connecting, commissioning and testing on completion complete all as specified and directed. |
| 98 | M & L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25 x 20 cm size complete all as specified and directed. |
| 99 | Supply, fix for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decorative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. |
| 100 | Supply and fixing LED Solar street light fitting 35/36 Watt mono crystalline solar panel with MPPT features of min 216wh cap LiFePO4 battery including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor with all connected accessories like nuts bolts clamps etc complete all as directed. |
| 101 | Supply and fixing HT 11 KV (Earthed) grade cold shrinkable end termination jointing kit outdoor type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70-95 sqmm complete all as specified and as directed. |
| 102 | Materials and labour for Aluminum conductor steel reinforced (ACSR) conductor as in LT overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc complete all as specified and as directed. |
| 103 | Supply and fixing Pin type insulator, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade confirming to IS-2486 complete all as specified and as directed. |
| 104 | Material and labour for anti-climbing device, spike type fabricated from structural steel comprising of MS flat 20mmx6mm, MS round bar pointed, 8mm dia, 20cm length welded on MS flat fixed with nuts, bolts, washers and welding with and including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 105 | BLANK |
| 106 | Supply only chain link MS galvanisd fencing, any size or type complete all as specified and directed. |
| 107 | Fixing only chain link fencing including line wire, any mesh, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wires complete all as specified and as directed. |
| 108 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 109 | Supply and fixing mild steel Fe 410-W (Gde-E- 250) quality-A, plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment complete all as specified and as directed . Total carried over to BOQ Rs. 2497666.87 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part III (External Water supply) Item Description of Item Unit Qty Rate per Unit (Rs.) Amount (Rs.) |
| 110 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 50 mm and all as directed. |
| 111 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 40 mm and all as directed. |
| 112 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 25 mm and all as directed. |
| 113 | Supply and lay pipe galvanized, “Medium class”, including fittings of dia 20 mm and all as directed. |
| 114 | S&F gun metal gate valve of following sizes screwed down high pressure with handle, Iron wheel (ISI marked) complete all as directed. (a) 50mm bore Each 3.0 979.08 2937.24 (b) 25mm bore Each 2.0 587.24 1174.48 (c ) 20mm bore Each 2.0 540.11 1080.22 |
| 115 | Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes,etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed. |
| 116 | M/L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed. |
| 117 | M/L for Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed. Total carried over to BOQ Rs. 70317.46 Signature of Contactor Date: Schedule 'A' Part IV (Road, Path Curvert) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 118 | Surface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft/loose soil |
| 119 | Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point. |
| 120 | M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering |
| 121 | Cement concrete type D-2 1:4:8 (using 20 mm graded aggregate) as in foundation filling and mass concrete , sub base complete all as directed. |
| 122 | Material and labour for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. |
| 123 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone agg) as in seismic and other similar bands, coping, bed block or similar work including necessary form work complete all as specified. |
| 124 | Providing and laying at or near ground level factory made kerb stone incl earth work of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. Total carried over to BOQ Rs. 568018.9 Signature of Contactor Date: Schedule 'A' Part V (Sewage Disposal) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 125 | Excavating in trenches in any type of soil , n exc 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soil complete all as specified and as directed. |
| 126 | Excavating in trenches in any type of soil , n exc 1.5 m wide and exc. 1.5 m in deep and n.exc 3.0m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and getting out soil complete all as specified and as directed |
| 127 | Returning, filling in, including spreading ,leveling, watering and well ramming in layers n. exc 25 cm with soil complete all as specified and as directed. |
| 128 | Removal of excavated material (soil) to a distance exc 50 m n. exc 250 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 129 | M&L for concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 complete |
| 130 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. |
| 131 | M&L for Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:4).complete all as specified and as directed. |
| 132 | M&L, 15mm thick rendering on any faces of stone, concrete or brick work in CM 1:4 surface finished even and fair complete all as specified and as directed. |
| 133 | M&L for 15 mm thick rendering in cement mortar (1:3) on brick / concrete/ stone surfaces mixed with water proofing compound as per manufacturer instruction , finished even and smooth using extra cement complete all as specified and as directed. |
| 134 | Supply only water proofing compound. |
| 135 | M&L for cement concrete type C2 1:3:6 (40mm graded stone aggregate) in foundations, filling and mass concrete complete |
| 136 | M&l for cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as in coping complete |
| 137 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 138 | S&F TMT steel bars 6 to 8mm in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed |
| 139 | S&F TMT steel bars 5mm dia and over, up to and including 10mm dia in stirrups spcers and binders. |
| 140 | M&L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 141 | M&L for cement concrete type B2 , 1:2:4 using 40 mm gradded stone aggregate in surface channels and drains complete |
| 142 | BLANK |
| 143 | BLANK |
| 144 | BLANK Total carried over to BOQ Rs. 202847.17 Signature of Contactor DY Dir(Contracts) Date: For Accepting Officer Schedule 'A' Part VI (Area Drainage) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 145 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 146 | M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 147 | M&L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate complete all as specified and directed. |
| 148 | M&L for RCC M-25 Design Mix as in fdn. all as specified |
| 149 | M & L 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement complete all as specified and directed. |
| 150 | M&L for PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in cills, PCC blocks, coping, bed plates, seismic and other similar bands, plinth bends, etc including weathering slightly rounded or chamfered angles and throuting, inclusing necessary form work etc complete all as specified and directed |
| 151 | M&L RCC type B 1, 1:2:4 (20mm graded agg) as in walls, retaining wall,basement walls etc |
| 152 | M&L Precast cement concrete Type B-1 1:2:4 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:6 complete all as specified and as directed. |
| 153 | Mild Steel TMT bar 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. |
| 154 | Returning filling in including spreading levlling ,Watering and well ramming in layers nexc 25cm thick complete all as specified and directed. |
| 155 | Removing excavated soil exc. 50m but not exceeding 250 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. Total carried over to BOQ Rs. 997676.79 Signature of Contactor Date: Schedule 'A' Part VII (Site Clearance) Item Description of Item Unit Qty Rate per unit(Rs.) Amount (Rs.) |
| 156 | Suraface excavation n.exc 30 cm deep and averaging 15 cm and getting out in soft soil. |
| 157 | Excavating over areas, n exc 1.5 m deep and getting out soft/Hard Soil |
| 158 | Earth filling (for site development) incl raising (or lowering) not exc 1.5 m high earth spreading in layers n.exc 30 cm thick watering and rolling and finishing to reqd size and shape etc |
| 159 | Removing excavated material to a distance exc 500m but n exc 1.5km, depositing where directed at a level n exc 1.5 M above the starting point. Total carried over to BOQ Rs. 106561.98 SIGNATURE OF CONTRACTOR DY Dir (Contracts) DATED _________ FOR ACCEPTING OFFICER Schedule 'A' Part VIII (Lighting Protection System) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 160 | S&F aluminium strips 25x3.15 mm with saddles and and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 161 | S&F test point terminal block made out of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8 mm dia 25mm long hex. Head screw, drolled, cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthic enamel paint complete all as specified and directed. |
| 162 | S&F air termination rod single pointed aluminium rod length 12 mm dia & 300 mm long. complete all as specified and directed. |
| 163 | M & L for 100 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in floor. complete all as specified and directed. |
| 164 | Supply and errect vertically Galvanised, medium grade pipe 20 mm dia meter complete with fittings for raising height for air termination rods complete all as specified and directed. |
| 165 | M & L for demolition of road/ path / concrete in ground floors and pavings PCC 1:2:4 type B1 n exc 15 cm thickness (below or above ground level). complete all as specified and directed Total carried over to BOQ Rs. 27904.72 Signature of Contactor Date: Schedule 'A' Part IX (Cooling Appliances) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 166 | Supply, installation,commissioning of Water cooler fully stainless steel, electric driven and single phase having approx storage 120 litres and nominal cooling capacity 60 Litres per hour . |
| 167 | Supply only bottled water dispenser, having option of dispensing hot and cold water with cooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity 1.6 ltrs, working in R - 134a refrigerant. Total carried over to BOQ Rs. 137715.7 Signature of Contactor Date: Schedule 'A' Part X (Internal electric Supply) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 168 | M & L for Point wiring using approved colour coding as per IS 694 , with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with mudular metal box min 1.2mm thick, duly covered with modular white colour plate with frame and other necessary accessories ncluding PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :- Note :- a) One circit should have maximum 8 to 10 pointsb) Circit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circit wire should be 2.5 sqmm for L, N, Earth point .c) Core coding for phase wires are RYB maintain, for neutral black colour and for Earth Green (a) One light point controlled by one, one way switch 5 Amps Point 292.0 992.75 289883.0 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator Point 76.0 992.75 75449.0 (c) One light point controlled by one, two way switch 5 Amps Point 4.0 1397.96 5591.84 (d) One bell point controlled by one, bell switch 5 Amps Point 4.0 992.75 3971.0 (e) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. Point 24.0 284.1 6818.4 (f) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. Point 63.0 1070.4 67435.2 |
| 169 | Description all as per item No 1 here in before but using 2.5 sq mm single core copper conductor two nos cables of multistranded FRLSH PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.Note :- a) Circit wire from MCB to switch board is deemed to be included with unit rate of item point wiring and the size of circit wire should be 2.5 sqmm for L, N, E |
| 170 | S & F ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete. |
| 171 | S & F modular switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified. |
| 172 | S & F modular switch piano flush type, single pole, two way, and 5/6 Amp single module complete all as specified. |
| 173 | S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified. |
| 174 | S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 175 | S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. |
| 176 | S & F Bell push modular 6 Amps single module complete all as specified. |
| 177 | S & F Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 178 | M & L for Sub main wiring with approved colour coding as per IS 694 with two single core PVC insulated FRLSH cable with stranded copper conductor of size 4 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor FRLSh cable as earth wire complete all as specified and as directed. Note :- a)Two runs of 4 sqmm cable,one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit.b) Each 12 way DB separate ciruits to be drawn from main VTPN |
| 179 | M & L for Sub main wiring with approved colour coding as per IS 694 with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:-a) Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit .b) Each 8 way DB separate ciruits to be drawn from main VTPN . |
| 180 | M & L for Sub main wiring with approved colour coding as per IS 694 with 4 single core PVC insulated FRLSH cable with stranded copper conductor of size10 .00 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 10.00 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- a)Two runs of 10.00 sqmm cable,one run of 1.00 sqmm cable and one run of PVC conduit will be measured as one unit.b) MCCB 125A separate ciruits to be drawn from main VTPN . |
| 181 | S & F for MCCB four pole rated capacity 125Amps, 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed. |
| 182 | S & F for MCCB four pole rated capacity 63Amps, 415 Volts breaking capacity 16 KA, 'C' curve complete all as specified and as directed. |
| 183 | S & F for MCB Single pole rated capacity 63 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 184 | S & F for sheet metal enclosure MCB DB SPN 12 way with suitable current rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. Note :-The rate of dummy plate shall be deemed to be included in unit rate of item. |
| 185 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.Note :-The rate of dummy plate shall be deemed to be included in unit rate of item. |
| 186 | S & F for Tripper RCBO of rating 32 Amps,DP, 10 KA, , 4 M , 300mA (nearest standard size ) 240 Volts , protection against over currents and earth leakage faults As per IS 12640-2 & IEC 61009-1complete all as specified and as directed by Engineer -in Charge . |
| 187 | S & F for MCB Single pole rated capacity 6-32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 188 | Supply and fixing ceiling fans complete made with copper wound windings, blades, down rods, electronic regulator modular type and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.0 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 189 | S & F exhaust fan of 300 mm sweep Airflow capacity 900 cubic meter per hour,Noise level 50DB , RPM 1350 230 volt made of copper wound winding , double ball bearing , metalic body complete with frame louver with nuts ,bolts and washers, embedded in the wall including fixing arrangements provision of PVC flexible copper cable three core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for by providing Metal welded wire mesh thickness not less than 2mm and grid size not less than 10mm to protect foreign objects fixing before louver Provide compelte all as specified and directed. |
| 190 | S & F for wall mounted LED tube light fitting 1x 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting,luminous efficiency not less than 120 lumen/watt, CRI > 80% , THD < 30% , driver Efficiency > 85% , PF > 0.9. Correlated Color Temperature 6500K (cool daylight) 170 Volts to 230 volts and LED Chip, Diver and Housing should of same make with warranty option of 2 years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor and flexible conduit of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 191 | S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts(or nearest standard size) , luminous efficacy not less than 110 lumen/watt, LED Chip, Diver and Housing should of same make with pre wired and necessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. Total carried over to BOQ Rs. 1605471.5 Signature of Contactor Date: Schedule 'A' Part XI (Internal Water Supply) Item Description of Item Unit Qty Rate per unit (Rs.) Amount (Rs.) |
| 192 | S&F 15 MM bore galvanized steel tubing, medium grade galvanized with all fittings ,fixed to walls and cellings or laid in floors incl cutting chasing and making good complete all as specified and directed. |
| 193 | S&F 20 MM bore galvanized steel tubing, medium grade galvanized with all fittings , fixed to walls and cellings or laid in floors complete all as specified and directed. |
| 194 | S&F 25 MM bore galvanized steel tubing, medium grade galvanized with all fittings , fixed to walls and cellings or laid in floors complete all as specified and directed. |
| 195 | S&F 20 MM bore gun matel glove or gate valve cast copper alloy with handle screwed both ends for GI out let /inlet pipe or union including threading to existing pipes on both ends complete all as specified and directed by engineer in charge. |
| 196 | S&F 25 MM bore gun matel glove or gate valve valve cast copper alloy with handle screwed both ends for GI out let /inlet pipe or union including threading to existing pipes on both ends complete all as specified and directed by engineer in charge. |
| 197 | S&F 15 MM dia pillar taps, cast copper alloy with capstan head chromium plated , screwed down high pressure with or without lettered ‘Hot or Cold’ with long screwed shanks and fly nuts , screwed for iron pipe, complete all as specified and directed |
| 198 | S & F for long body Bib taps, cast copper alloy with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, 15 mm, fancy type, chromium plated fixed complete. |
| 199 | S & F for Angle cock/ Stop valves, cast copper alloy, screwed down, high pressure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed15mm fixed complete. |
| 200 | S & F PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed. Total carried over to BOQ Rs. 148413.08 Signature of Contactor Date: |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail