| 1 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. |
| 2 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Walls (any thickness) including attached pilasters, buttresses plinth and string course. |
| 3 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc. |
| 4 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : :Columns, pillars, posts and struts etc. |
| 5 | Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for ::Grid roofing with panel area less than 2.25 Sqm. (contact area to be measured). |
| 6 | Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge . All works upto floor V floor Providing M-25 grade concrete by using min 410 kg of cement per cum instead of M-20 grade design mix. |
| 7 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 8 | Providing and fixing 150 mm wide sheet covering over expansion joints with iron screws as per design to match the colour / shade of wall treatment. :Aluminum fluted strips 2 mm thick |
| 9 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 10 | Half brick masonry in Superstructure , above plinth level upto floor V level using bricks of designation 75:Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 11 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in::Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 12 | Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in ::Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 13 | Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu / Jalore (Red/Choclate/Black/Pink Colour) :Above 3601 Cm2 Slabs |
| 14 | Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide |
| 15 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).:For fixed portion Powder coating aluminum ( minimum thickness of powder coating 50 micron) |
| 16 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately).:For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).: Powder coating aluminum ( minimum thickness of powder coating 50 micron) Including item no 16.2 Extra for shutters of sliding aluminum windows |
| 17 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.:Anodised aluminum (anodised transparent 81 dyed to required shade according to IS : 1868. (Minimum anodic coating of grade AC 15, Anodizing to be got done from approved Anodizer) |
| 18 | S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws at not exceeding 150mm distance at all heights with all lead and lift with scafolding. |
| 19 | Providing and fixing Drapery rod shall be made of 20 gauge cold rolled steel strip. Which is electrical resistance welded, The section will be available 25.4 mm diameter the section shall be coated with acid resistance polymer finial shall made from ABS material in nearest matching colour of rod. The ring shall be made from ABS material in nearest matching colour to rod. Brackets of made of galvanized steel. |
| 20 | Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 20mm thick . |
| 21 | 6 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) |
| 22 | P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. :Size 600 x 450mm x 4 mm thick |
| 23 | C.P. brass towel rail with brackets 450 x 20mm. |
| 24 | P & F Grating of approved quality/make :Stainless Steel Sheet size 125mm dia. |
| 25 | P & F Liquid Soap Container with brackets complete of approved make: C.P. brass |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,):20mm nominal outer dia pipes |
| 27 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). :25 mm nominal outer dia pipes |
| 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). :32mm nominal outer dia pipes |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement , trenching refilling & testing of joints complete as per direction of Engineer in Charge.(External work). : :50 mm nominal outer dia pipes |
| 30 | P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: 50mm nominal bore. Horizontal |
| 31 | Providing & fixing Spun –Centrifugally cast Iron Pipes (IS : 3989 Mark ) of Approved make in wall or in floor with M.S. Holder bat clamps in 10 X 10 X10 Cm. M-15 Grade concrete blocks, joints filled with CM 1:4 with spun yarn including cutting holes and making good the wall:-:100mm dia |
| 32 | Providing & fixing Spun –Centrifugally Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm W/O door (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100 mm –do- : Offset |
| 33 | Providing & fixing Spun –Centrifugally Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm with door (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100 mm –do- Socket |
| 34 | Providing & fixing Spun –Centrifugally Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm W/O door (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100 mm –do- D/Door Y-Tee |
| 35 | Providing & fixing Spun –Centrifugally Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm W/O door (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100 mm –do- Bend |
| 36 | Providing & fixing Spun –Centrifugally Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm W/O door (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100 mm –do- Tee |
| 37 | Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm with door : Bend |
| 38 | Providing & fixing Spun –Centrifugally cast Iron Pipes fitting (IS : 3989 Mark ) in CM 1:4 with spun Yarn.:100mm with door: Tee |
| 39 | Add extra for Lead caulked joints (IS:782-1978) in sand cast iron pipes/spun- 100mm dia, 0.98 Kg. Pig lead |
| 40 | 150mm dia,1.48 Kg. Pig lead |
| 41 | Providing and Fixing Spun –Cast Iron floor trap (Nahani) of (IS :3989 Mark ) approved quality / make with socket down or hinged grating including cutting and making good the floor :- Size 100 x 100 mm |
| 42 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:2000 litres capacity. |
| 43 | P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm. |
| 44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 75 mm nominal inner dia .Pipes. |
| 45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 100 mm nominal inner dia .Pipes. |
| 46 | P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipe with C.P. Brass nuts upto length, 450 mm |
| 47 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 48 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the alls etc., 25 mm nominal outer dia .Pipes. Please Enable Macros to View BoQ information |