| 1 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with inc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of ngle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with ecommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board |
| 2 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991, in true horizontal level suspended on interlocking metal powder coated T-Grid of hot dipped galvanised iron section of 0.40 mm thick on Silhouette profile,rotary stiched double webbed white with 6mm reveal profile (white/black),comprising of main-T runners of size 15x42mm of length 3000 mm, cross - T of size 15x42 mm of length 1200 mm and secondary intermediate cross-T of size 15x42 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 22x19x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.With 15 mm thick integral densified micro edge light weight calcium silicate false ceiling tiles |
| 3 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles |
| 4 | Providing and fixing premium fabric roller blinds of Vista, Mac, Deco or equivalent make and of approved colour and shade including installing the manual operating mechanism, complete as per the direction of Engineer-in-charge. |
| 5 | VRV Outdoor UnitSupply, installation, testing and commissioning of TOP DISCHAGE Variable Refrigerant Flow modular type air-conditioning system suitable for Cooling & Heating both by multiple scroll compressor controlled by individual inverter complete with indoor and outdoor units with individual wired and wireless/wired remote controller for indoor units and centralized controller, interconnecting refrigerant piping, full charge of refrigerant gas (R-410A) & oil, internal control cabling and fittings etc. as per details given in specifications and having following items. The out door units shall be suitable for 3 phase 4 wire system, 415V + 10 %, 50 Hz AC supply and indoor shall be suitable for Single phase 220-240V, 50 Hz AC supply.Outdoor Units Supply, installation, testing & commissioning of Modular type outdoor units equipped with highly efficient scroll compressors(OEM manufactured) fully inverter controlled i.e. changes its speed in accordance to the variation in cooling loads, special heat exchanger, low noise condenser fan, & including full charging of R-410A refrigerant gas complete i/c powder coating complete as per specifications. Out door units shall be provided with MS stand of suitable size duly painted with corision resistant paint suitable for outdoor application. The units shall be in combination of one or more units which shall be selected in such a way that EER in cooling mode of each unit at 100 % shall not be less than 4.1 i.e on 35 Deg C DB Ambient and at 27 Deg CDB & 19 Deg CWB inside conditions. The units shall be suitable to operate upto 52 Deg C ambient conditions in summer and -25 degree celcius in winter.All the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control,which should be air cool.Machines shall be suitable for working with BMS system. The outdoor unit should be fitted with low noise level and should not be more than 60 db (A) during Night Shift Mode when measured at a point 1 mtr in front of the unit at a height of 1.5 mtrs. External Static pressue of the outdooe units should not be less than 80Pa It is mandatory that each compressor shall have inverter technology separately i.e. outdoor units shall have all inverter based compressor.Compressor and machine should be of same OEM. The inverter technology based Scroll compressor modular type VRF equipment should be designed, so that refrigerant piping between outdoor units and furthest indoor unit shall be extendable up to 200m. Allowable level difference between outdoor & indoor unit shall be 110m in case of outdoor unit on top & 110m in case of outdoor unit at bottom. Allowable level difference between two indoor units connected to same outdoor unit shall be upto 40m.Following capacities of ODUs are at standard operating condition as defined above and Vendor to indicate COP at 100% load & at part loads i.e. 75% & 50% in the data sheets/ shop drawings:The outdoor unit shall have twin scroll compressors and be able to operate even in case of breakdown of one of compressor. Each circuit of outdoor units shall have a minimum of 2 cans for redundancy incase of breakdown. The Equipment should have a operating range till 52 Deg C. Approved Makes - Daikin/ Samsung/ Hitachia) Capacity : 24 HP - Twin Compressor per outdoor unit with COP in Cooling of 4.0 |
| 6 | b) Capacity : 22 HP - -Twin Compressor per outdoor unit with COP in Cooling of 4.0 |
| 7 | Supply, Installation, Charging, Testing and Commissioning of Air Cooled VRV/VRF units VRV Indoor Unit Ceiling suspended Four Way Cassette - Capacity : 6.0 HP - CFM 1300 CFM(CFM Needs to be matched) |
| 8 | Supply of OEM Manufactured of Corded Remote Controller |
| 9 | Supply of OEM Manufactured Ref/Y/T Joints/Connection joints as per OEM recommendation and submitted drawings |
| 10 | Supply, Installation, testing Commisioning of Centralised Controller - Cloud/web based |
| 11 | Installation, Charging, Testing and Commissioning of Air Cooled VRV/VRF units. The prices should include any lifting, shifting and positioning of outdoor units - For 48 HP Circuit |
| 12 | Installation, Charging, Testing and Commissioning of Air Cooled VRV/VRF units. The prices should include any lifting, shifting and positioning of outdoor units - For 142 HP Circuit |
| 13 | Supply and Installation of Interconnecting Refrigerant Piping for 48 HP Circuit, of various sizes as required for the full functionality of the VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the architect in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. All External Copper piping to be with Lag coating and on cable Tray(cable tray to be quantified separately), All necessary civil works like cutting & chasing of walls/floor/ glass, putting up of scaffolding etc. and make them good thereof is included in the item. |
| 14 | Supply and Installation of Interconnecting Refrigerant Piping of 142 HP Circuit of various sizes as required for the full functionality of the VRF system etc. complete in all respects duly insulated with closed cell nitrile rubber as per specifications of the manufacturer. the contractor shall submit a detailed drawing approved by the manufacturer showing the piping sizes & layout to be followed at the site with the tender document. the contractor shall also get the drawings showing outdoor units in connection with indoor units approved from the architect in original from and then the head office of the manufacturer with a certificate stating that the piping layout is as per company specifications for full functioning of the VRF system. All External Copper piping to be with Lag coating and on cable Tray(cable tray to be quantified separately) All necessary civil works like cutting & chasing of walls/floor/ glass, putting up of scaffolding etc. and make them good thereof is included in the item. |
| 15 | Providing UPVC pipes of various sizes for condensed water drainage for 48 HP circuit from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as pproved by architect All necessary civil works like cutting & chasing of walls/floor/ glass, putting up of scaffolding etc. and make them good thereof is included in the item. |
| 16 | Providing UPVC pipes of various sizes for condensed water drainage for 142 HP circuit, from Indoor unit to nearest disposal point in toilet/ outside rain water harvesting system as pproved by architect All necessary civil works like cutting & chasing of walls/floor/ glass, putting up of scaffolding etc. and make them good thereof is included in the item. |
| 17 | Supply, installation, testing & commissioning of cubical type main MV panel board for 48 HP circuit and suitable for 3 Phase, 50 Hz and of 35 MVA rupturing capacity at 415 volts, fabricated from minimum 2mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with following mountings, interconnections etc. as required. (GA drawing of panel to be provided before fabrication). Panel shall be Floor mounted type with cable entry at the top and IP-55 Degree of protection. Panel shall be powder coated having colour shade RAL-7032. Panel should be IP65 Rated. This work also includes the cost of cement concrete pedestal for fixing the electric panel 300mm above GL.Note:- Consider 0.8A / Sqmm current density for bus bar size calculation.PANEL FOR VRV / VRFIncoming - To be taken by contractor as per the Outdoor Capacity and approved by Engineer incharge of Institute 4P MCCB, 415 Volts, 50HzAluminium BusbarsTPN, 415 volts, 50 Hz, 3 phase, 4 wire colour coded Al bus bars.Outgoing1 Nos 125A, 4P MCCB, 415 Volts, 50 Hz. With Neutral link for VRF / VRV.1 No. 0 - 100 Amps, 96mm square Digital Ammeter with CT's and selector switch.1 Set R Y B phase indicating lamps. |
| 18 | Supply, installation, testing & commissioning of cubical type main MV panel board for 142 HP Circuit and suitable for 3 Phase, 50 Hz and of 35 MVA rupturing capacity at 415 volts, fabricated from minimum 2mm thick CRCA sheet powder coated through seven tank process facility for prickling and degreasing complete with following mountings, interconnections etc. as required. (GA drawing of panel to be provided before fabrication). Panel shall be Floor mounted type with cable entry at the top and IP-55 Degree of protection. Panel shall be powder coated having colour shade RAL-7032. Panel should be IP65 Rated. This work also includes the cost of cement concrete pedestal for fixing the electric panel 300mm above GL.Note:- Consider 0.8A / Sqmm current density for bus bar size calculation.PANEL FOR VRV / VRFIncoming - Capacity to be taken by contractor as per the Outdoor Capacity and approved by Engineer incharge of Institute4P MCCB, 415 Volts, 50HzAluminium BusbarsTPN, 415 volts, 50 Hz, 3 phase, 4 wire colour coded Al bus bars.Outgoing6 Nos 125A, 4P MCCB, 415 Volts, 50 Hz. With Neutral link for VRF / VRV.3 Nos MCB, 230 Volts, 50 Hz. With Neutral link for VRF / VRV for two sub Panels with 32 no.s 10 A MCB eachPrices for three sub panels also to be quoted along with this panelInstruments1 No. 0 - 415 Volts, 96mm Square Digital Voltmeter with protection fuses & selector switch.1 No. 0 - 100 Amps, 96mm square Digital Ammeter with CT's and selector switch.1 Set R Y B phase indicating lamps. |
| 19 | Supply and installation following size of perforated pre paintied M.S. Cable tray, with perforation not more than 17.5%, in convin sections, jointed with connectors, suspended from the ceiling with MS suspenders including bolts & nuts, painting suspenders etc as required. a) 300 mm width 75 mm thick x 2 mm thick |
| 20 | b) 150 mm width 75 mm thick x 2 mm thick |
| 21 | Providing & fixing control cum transmission wiring/ Control Cabling of shielded 2 core x 1.5 sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller for 48 HP Circuit. |
| 22 | Providing & fixing control cum transmission wiring/ Control Cabling of shielded 2 core x 1.5 sq. mm copper in suitable conduits between indoor and out door unit & indoor unit & its remote controller for 142 HP Circuit |
| 23 | Supply of following sizes of XLPE insulated PVC sheathed, copper conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date.i) 4 C x 25 sq.mm Main panel to outdoor unit |
| 24 | ii) 3 C x 6 sq.mm Main panel to indoor sub panel |
| 25 | iii) 3 C X 2.5 sqmm Indoor sub panel to indoor unit |
| 26 | Supply/laying of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 1.1 KV grade conforming to IS 7098 amended upto date. i) 3.5 C x 400 sq.mm in trench covered with FPS brick width wise at a depth of not less than 750mm - For 142 HP Circuit |
| 27 | ii) 3.5 C x 70 sq.mm in existing trench - For 48 HP Circuit |
| 28 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conducter cable of 1.1 kV grade as required. i) 3.5 C x 400 sq.mm in trench - For 142 HP Circuit |
| 29 | ii) 3.5 C x 70 sq.mm in existing trench - For 48 HP Circuit |
| 30 | Providing and fixing 40X3 mm thick MS flat clamp for PVC insulated and PVC sheathed/XLPE power cable of 1.1 kV grade of the following size on cable tray as required. -upto 120 sqmm |
| 31 | Providing and fixing 6 SWG dia. GI wire on surface or in recessed for loop earth as required including clamping wherever required. |
| 32 | Supplying, installing and commissioning of Digital podium MS Powder coated with college logo on front side with following specifications:-a) DISPLAY BUILT-IN SPEAKER, TOUCH TYPE MONITOR, MOTORIZED b) ADJUSTABLE SCREENc) SIZE 21.5 inch Screend) RESOLUTION FULL HDe) BRIGHTNESS>350 NITSf) ASPECT RATIO(TYPICAL) 16:9g) COMPUTER INTERFACE USB X1, HDMI X1, VGA X1h) RESPONSE TIME 6 MSi) CONSOLE PANEL DISPLAY PORTS VGA, HDMI, USB X1, RJ 45 X1j) TYPE/MOUNTING FREE STANDING, ADJUSTABLE TILTk) BODY TYPE CRCA STEEL SHEET, WHEEL WITH LOCKl) BUILT-IN DEVICESm) MICS GOOSENECK MIC X 1, Handheld Mic 1 |
| 33 | Supplying, installing and commissioning of 86\\" Interactive Flat Panel Technical Specifications: a) Display Panel Diagonal size: 86\\"b) Backlight Technology: DLED c) Display Resolution: 4K d) Display Brightness (Nits): >450 Nits e) Display Aspect Ratio: 16:9f) Touch interface: Touch sensitive as well as pen driven Touchg) Technology: Infrared optical Number of touch points (Number): 20 h) Response time (milli-seconds): 4ms i) Operating System Compatibility: WINDOWS j) Provision of in-built speakers: Yes k) Built In Speakers:20W*2 l) Provision for wall mounting: Yes m) Wi-Fi connectivity: Yes n) Number of stylus to be supplied with the board: 2 o) Android Specification -Android 14.0, p) 8GB RAM, q) 128GB Internal Memory with Octa-Core Processor. Please Enable Macros to View BoQ information |