| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 2 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 3 | Self levelling of flooring by using fibre-reinforced self-levelling compound (i.e Mapei Ultrplan 3240 or equivalent) 2mm thick (avg.) on existing concrete, screeds, stone, ceramic tiles, old and new timber floors, parquet and plywood. Levelling will be done to such extent to provide level surface and no impression of existing flooring will be seen, as per direction of Engineer-in- charge. |
| 4 | Providing and fixing of 2mm thick Homogeneous flexible PVC floor covering having non -directional design, with antistatic properties of size 2mtrs x 20mtrs having total weight 3250 g/m2. (No Asian manufacturing).It also should confirm to class Bfl-s1 in flammability test as per EN13501- 1, slip resistance of R9 as per EN 13893 Class DS and very low VOC emission having Euro fins certified and GBCA/NZGBC Green Star IEQ-VOC-Compliant It shouldm demonstrate from independent tests that it inhibits the growth of MRSA on the floor to prevent any kind ofinfection. It should also achieve a BRE Global Environmental A + Rating and a Green Tag LCA Rate certified with Green Rate level A- Gold Plus Warranty: 10 years. User Class: Type 1 as per EN ISO 10581,Make : Polyflor Classic Mystique PUR |
| 5 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 6 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 7 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width |
| 8 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 9 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 10 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 11 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 12 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 13 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 14 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittingsshall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 15 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. Pre-laminated particle board with decorative lamination on both sides |
| 16 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 17 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. |
| 18 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 19 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :-200x10mm |
| 20 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 300x16 mm |
| 21 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 22 | SUPPLY & INSTALLATION OF HERMETIC SEALED MANUAL SLIDING DOOR of size 1200*1800mm WITH PIR core (CFC free) with high pressure laminate on both side conforming to EN 438-3_2005. The door profile are flushed with door leaf in aluminium alloy, grade 6063, temper T6 natural anodized finish. Sealing: Easily replacable all around EPDM gasket. when clsed, the EPDM gasket is pressed against the frame to make sure perfect sealing. Wall frame: Aluminium alloy, grade 6063, temper T6 in natural anodized 20micro metre. Vision panel: Double glazed IG unit with 5mm tempered glass on both sides. Lever Handle: Solid AISI 304 grade stainless steel with rubber spring system. Rail: Aluminium alloy, Grade 6063, temper T6 natural anodized. Single length upto 1800mm wide doors 45 degree indentations with simultaneous \\"down and in\\" movement. Roller: Special grade self-lubricating PA |
| 23 | Supply of stainless steel sink of size 2800(L)*600(W)*920(H). Sink comprises of two bowl and each bowl should be of size 1400*600*300mm. Front of sink should be made of SS 304 grade shutter and inner side partition and rack for placing of chemical. Both bowl of sink should fitted with swann neck tap(Jaquar make) . There should be proper connection for drainage pipe. Sink should also have a foot control system. At back side of sink there should be extension of 300mm in height to prevent flashing of water on wall. Sink should be made of stainless steel grade 304 material and 1.2mm thick. |
| 24 | S/I/T/C of Single Dome Single arm Major Surgery Light ceiling mounted, cool light with latest generation LEDs,Light-head Material Aluminium-based for effective cooling and minimal heat, Central Illuminance>=160,000 lux, Light-head Diameter 500 mm, CCT (Correlated Color Temperature) Adjustable,3500–5500K, Service Life of LEDs>=60,000 hours, Control Panel -OLED display-based control panel for light control, CRI (Color Rendering Index) 96, Dimming Range0–100%, Providing suspension arm capable of providing continuous 340- 360 deg (for non-camera arms), Anti-glare lenses with acute and sharp focus, On/Off switch on light-head and as directed by engineer in charge.Make-Komax, Stryker or equivalent make of similar specification and as per directed by enigneer in charge. |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit asrequired.recessed steel/ PVC conduit as required. 3 x 4 sq. mm |
| 26 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit asrequired.recessed steel/ PVC conduit as required. 6 x 4 sq. mm |
| 27 | Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm |
| 28 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch |
| 29 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 30 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) |
| 31 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 32 | LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt), Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life, CCT /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm), 36 Watt |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required |
| 34 | Single deck AHU (30% Fresh air & 70% recirculation):-Supply Installation Testing & Commissioning of double Skin Horizontal Air Handling Unit complete with, consisting 30% fresh air intake provisions with aluminium dampers on fresh air side and supply air side, all filters flanged type i.e. pre filters (EU-4), fine filter (EU-7) sections with double skin (45±2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. Sandwiched between 0.8 mm thick G.I. pre coated Sheets for Outer skin and internal skin shall be plain G.I of 0.8 mm thick. All frame work shall be with thermal break profile constructed. The blowers shall be backward curved Centrifugal plug fan (with calibrated nozzle for air flow/DP measurement) with driven motor - IE3 (VFD compatible) with minimum IP55 protection. Cushy foot mountings, Inspection LED lamp, door limit switch, SS insulated condensate drain pan made out of SS-304 and standard accessories. The unit shall be comprising of 6 row deep Dx air cooled coil made out of copper tubing and copper header. AHU to be mounted on adequate RCC cubes with double vibration pad and GI sheet etc. to be considered in scope.UVGI System:- UVGI system shall be designed to cover the entire face area of the cooling coil to achieve near total elimination of bacteria/ virus / biomass on the cooling coil. Required number of UVGI Lamps in the AHU's for the cooling coil area, along with reflector, ballast, junction box, mounting arrangement complete with connections etc. as required. UVGI system shall be installed downstream of the cooling coil.AHU shall have provision for fixing of reheater and humidifier including space for all the necessary fitting and accessories.Supply Air Fan Capacity, CFM : 1000Inline fan outdoor type of capacity 300 CFM to be installed at return ductDx Air cooled Load,TR : 08Total Supply side Static,Pa : 1500 |
| 35 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet |
| 36 | Supply, installation, testing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Thickness 0.80 mm sheet |
| 37 | Supply, installation, testing and commissioning of 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc., for cladding of outside / exposed ducts. |
| 38 | Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc., as per specifications. |
| 39 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply/Return Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 40 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper |
| 41 | Supply, installation, testing and commissioning of fire dampers in supply air duct/main branch and return air duct as and where required of required sizes i/c control panel, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Actuator |
| 42 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm |
| 43 | Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm |
| 44 | Supply Installation, Testing & Commissioning for WARD AHU of modular type Variable Refrigerant flow /Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A/latest Refrigerant, vibration isolators, outdoor unit frame with suitable foundation,complete with all accessories as required etc. The unit shall deliver the rated capacity at AHRI Conditions and work even at approx. 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 complete as per the technical specifications. Capacity: 10 HP |
| 45 | Supply Installation, Testing & Commissioning of AHU Kit consists of a control PCB, electronic expansion valve, complete with all accessories as required etc. This kit will connect the AHU to the VRF Outdoor Unit. |
| 46 | Supply Installation, Testing & Commissioning of Corded Thermostat cum controller for temperature setting and operation, along with communication and power wiring from AHU or VRF to Remote controller installation as per location inside ward complete with all accessories as required etc. (Dual mode: Cooling & Heating). |
| 47 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 48 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, complete with all accessories as required etc. 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation |
| 49 | Supply, Installation, testing and commissioning of 40 mm dia nominal bore 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings likes elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. complete in all respect for AHU condensate drain piping with 19 mm thick nitrile rubber insulation, nut-bolts, supports, pipe support block etc. duly installed with 0.63 mm aluminium sheet cladding as required complete in all respect with fixing screws etc. |
| 50 | SITC of Laminar flow filter module of suitable size as required made out of heavy duty Aluminium powder coated extrusion with minimum and to house HEPA Filter at the rate 0.3 microns , 99.9997, H- 14Grade, Filter loading from ICU side Includes aluminum power coated capsule perforated diffuser alongwith adjustable opposed blade damper. This includes all required supports and accessories as per site requirement. Size - 600mm x 600mm |
| 51 | Supply, Installation, Testing & Commissioning of Electric tubular finned Heaters for OT OAHU of 02 kW capacity in SS construction and bank wise distribution, duly installed in ducts complete with mounting arrangement, safety thermostat, humidistat for humidity control, SSR based control, contactor etc.. Heater should be ISI marked. |
| 52 | Fabrication,Supply,Installation,Testing,Commisioning of Outdoor floor mount type AHU control Panel, CPRI approved with following specifications: CRCA Sheet of 3.15 mm, Grey Colour with Incoming: 1 Incomer -200 Ampere MCCB/36KA 4 Pole. Panel must include R,Y,B Indicator, with 300 ampere aluminium busbar, 1No Digital Multi Function Metre / Digital Load Manager suitable to connect with Centre Energy Monitoring System/BMS through RS485 connection.Outgoing:,Outgoing -1 Nos with 25 Ampere MCB/10/16KA 4 Pole “C” Curve for supply motor - 4 kW Outgoing -1 Nos with 63 Ampere MCCB/30KA 4 Pole for VRF outdoor unit. Outgoing -1 Nos with 32 Ampere MCCB/16/25KA 4 Pole for heaters - 02 kW (three bank distribution). All outgoings shall be with necessary MCB's, contactors, relays, illuminated push button for manual ON & OFF, indication lamps ( for ON,OFF,TRIP Status), Auto/Manual selector switch.Outgoings with suitable rating MCB's shall be considered for UVGI system, fire damper, AHU limit switch etc.Necessary safety interlocks like AHU motor interlock with service door limit switch, fire damper interlock, supply & exhaust fan interlock, UVGI system and heaters interlocks with AHU).Potential free Contact (for supply motor, exhaust motor, fire damper, heater, humidifier etc.) to be provided for Connections.Note:- 1. VFD (for motor speed control) with inbuilt PID controller for varying the speed of fan, along with DPT (0 to 3000 pa) sensor for measuring DP across fan and providing input to VFD. VFD to be installed/mounted in motor control panel.Capacity of VFD: 4 kW - 1 No. ( for Supply motor) 2. Provision of MCB / Contactor for UVGI system, AHU limit switch, Fire damper etc. to be considered in AHU control panel. |
| 53 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured aluminium cable 3.5 C X 95 sq. mm |
| 54 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 16 sq. mm |
| 55 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 10 sq. mm |
| 56 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 6 sq. mm |
| 57 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 4 C X 1.5 sq. mm |
| 58 | Supply, laying, Testing and Commissioning of following size XLPE insulated armoured Cable (Galvanised wire / strip) 1100 V Grade including end termination with brass compression glands and lugs, saddle / support for cable etc. as required and as per IS 7098 (Part 1) 1988 with upto date amendments on surface / cable tray as required and as directed by Engineering incharge (Compulsory ISI marked) (Cables for incoming to AHU control panel & outgoing cables for supply motor, exhaust motor, UVGI, limit switch, fire damper, heater, humidifier etc.) armoured copper cable 2 C X 1.5 sq. mm |
| 59 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 150 mm width X 50 mm depth X 1.6 mm thickness |
| 60 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required 100 mm width X 50 mm depth X 1.6 mm thickness |
| 61 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Please Enable Macros to View BoQ information |