| 1 | Earth work in excavation by mechanical means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m Sq. on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil : Incl Dewatering |
| 2 | Supplying and laying of quarry stone soling hand packed tightly incl ramming watering and filling of interstices incl all carriage complete job |
| 3 | Providing and laying in position cement concrete of specified grade incl curing excluding the cost of centring and shuttering- All work upto plinth level.1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40mm nominal size) incl all carriage complete job all carriages included |
| 4 | Providing and laying in position Reinforced cement concerete of specified grade 1:1.5:3(1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size crushed aggeregate) for reinforced cement concrete works excluding the cost of centering, shuttering, and reinforcement. All work at upto Plinth levels. M-20 incl curing and carriages |
| 5 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Tmt bars of grade FE500d |
| 6 | P/F of 20mm dia 450 mm long anchor bolts with nuts complete |
| 7 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) incl all carriage complete job |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form foundation footings etc |
| 9 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 10 | Providing and fixing in position, 60 mm thick factory made sandwiched puf panels between two Engineered sheets of pre coated profiles sheet of 0.8 mm (+ 0.05 %) with plain on one side and corrugation on other side both the sides total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. the panel shall be of dis-continuous line. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation. The sand witch panel core shall consist of 50 mm thick puf of density not less than 40 kg/ per cum(+/-2). Fixing operations of wall panels shall be completed in all respect as per drawings and specifications and under the overall direction of the Engineer-in-chargeThe panels should be GRIHA certified panels only |
| 11 | Providing & fixing Precoated galvalume profile sheets 0.50 mm TCT having a crest height of 2832mm at 195mm pitch and effective width of 975-1000mm and length to suit site requirement to the purlins using self drilling and self tapping fasteners of reputed make with purlin sheet using self drilling and self tapping fastners & Fixing flashings, valleys and ridges of colour coated galvalume plain sheet using self drilling and self tapping fasteners of reputed makel complete and as directed. The contractor shall give a minimum of 10 years guarantee for sheets against deterioration, disintegrations loss of luster, variation in colour, etc. and leakages across laps, fasteners etc. All types of steel sheets shall be load tested to satisfy 1.10 times the design wind load and coating thickness to the satisfaction of the Engineer-in-Charge. Fasterners shall also be load tested. The Contractor is to submit design and shop drawings for approval on the sheet profile, design and fabrication details before installation (including cost of all material, leads, lifts and carriages etc upto site of work complete) hi rib |
| 12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to lS: 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete SIZE 60 cm x 60cm same as plinth area |
| 13 | Providing and fixing false ceiling with 8 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087, finished with a coat of aluminum primer on both sides & edges, including two coats of synthetic enamel paint of approved quality on exposed face, fixed to a grid made out of anodized aluminum (with 15 micron anodic coating) T sections 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats and dash fastener. The suspenders shall be placed 600 x 1200 mm centre to centre including fixing to the frame with C.P brass screws and applying a priming coat of zinc chromate yellow primer incl cost of Aluminium fittings Same As ITEM No Cement Concrete Flooring A |
| 14 | Providing and fixing aluminium work for doors, window ventilators and partitions with extruded built up standard tubular sections/ appropriate Z. sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junction at top bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth rust free, straight , mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directionsl of Engineer in Charge Polyester powder coated aluminium (minimum thickness of polyester powder coated 50 microns) 20002 For Frames |
| 15 | Providing and fixing aluminium work for doors, window ventilators and partitions with extruded built up standard tubular sections/ appropriate Z. sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necessary filling up of gaps at junction at top bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth rust free, straight , mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ panelling, C.P brass / stainless steel screws, all complete as per architectural drawings and the directionsl of Engineer in Charge Polyester powder coated aluminium (minimum thickness of polyester powder coated 50 microns) 19592 For Shutters Incl Fixtures |
| 16 | Providing and fixing of 12mm thick Decorative type Particle Board |
| 17 | Providing and fixing of 5mm thick glass panes fitted with EPDM rubber in aluminuim door windows |
| 18 | Providing and fixing stainless steel (Grade 304) railing 1000 mm height made of Hollow tubes ,channels, plates etc. including welding, grinding,buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless stell nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc of required size on the top of the floor or the side of waist slab with suitable arrangement As per the Design specification/selection |
| 19 | Providing & laying 18mm minimum thick pre-polished (best quality ) Granite stone slabs (non water absoring) in counters, vanities etc on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)/12mm thick backing of cement mortar 1:3 (1 cement : 3 coarse sand) and joined with white cement slurry mixed with pigment or with standard tile made compound to match the shade of the slab. Including rounding, rubbing, clamping, curing, moulding, granite polish & making grooves as required complete (Note: The stone slab shall be cut to required size and laid to the required pattern including rounding, chamfering, bull nosing of the edges as directed. Actual area of slab, as laid shall be measured) Sample to be approved by Engineer-in-charge. (including cost of all material, leads, lifts and carriages etc upto site of work area of slab upto 0.5 sqm |
| 20 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete incl all carriage complete job |
| 21 | 12mm Thick Plaster in 1:3 Mortar Mix |
| 22 | Providing and laying in position colour vitrified tiles of anti skid tiles type of size 600mm x 600mm x 10mm thick of simpilo make conforming to ISI15622 laid on 1:4 mix i/c pointing of joints with white cement and matching pigment, all complete as per directions of incharge laid over 20mm thick (1:4) mix Mortor |
| 23 | Painting with Enamel paint on Metalsurface of Required Shade and colour Two or more coats on new work |
| 24 | Sanitary Fixtures |
| 25 | Providing and fixing white glazed vitreous (European style) P trap water closet with solid white plastic seat and lid, C.P.brass hinges and rubber buffers with 3/6 dual flush concealed flush set including reqd. fitting, CP actuator, CI chair etc. complete. |
| 26 | Providing and fixing white glazed vitreous china wash basin (Flat back counter mounted/ oval or flat back) with 32mm C.P. brass waste of standard pattern, 32mm dia C.P. brass bottle trap and union, 32mm dia C.P. pipe to wall and C.P. wall flange, CP brass pillar cock, CP brass angle valve with braided connection pipe complete with fixing Brackets painted white, required C.P. brass screws, nuts, bolts, consumable complete, cutting and making good the walls wherever required. (Basin Make Jaquar |
| 27 | Half threaded waste coupling: Jaquar Ald 709 |
| 28 | Bottle trap: Jaquar ald 769 |
| 29 | Pillar cock make Grohe |
| 30 | Angle Valve Grohe |
| 31 | 15mm dia braided connection pipe make jaquar |
| 32 | Providing and fixing Salem Stainless Steel A ISI 304(18/8) Kitchen Sink As per IS 13983 with CI Brackets ans stainless steel plug including painting of fttings and brackets, including cutting(GRANITE) and good the walls whereever require(610x510) mm |
| 33 | Providing and fixing 20mm dia C.P. brass quarter turn angle valves with C.P. copper connecting pipe, union nut and C.P. brass wall flanges. |
| 34 | Providing and fixing 15mm dia C.P. brass bib cocks with wall flange. |
| 35 | Two way qauter turn bib cock |
| 36 | Providing and fixing of liquid soap dispenser with brackets fixed to wooden cleats with C.P. brass screws |
| 37 | Providing and fixing of CP brass Health faucet with 8mm dia 1 mtr. Long PVC tube and wall hook fixed to wall with rawl plugs and CP brass screws complete.Make Jaquar |
| 38 | Providing in position storage type Hot Water electrical horizontal heaters with copper container, insulation, and stove enameled M.S. jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non return valve and 15/20mm dia outlet including making connections complete in all respects. (wall mounted with suitable M.S. bolts and nuts) Capacity - 50 Litte Make Racold |
| 39 | B. Soil, Waste, Vent & Rain Water Pipes |
| 40 | Providing and fixing uPVC Pipes complete (IS: 4985 Class-III) with uPVC pipe fittings e.g. elbows, tees, reducers, unions, plugs, flanges etc. and clamps and jointing with solvent cement including chase cutting and making good the walls etc. wherever required for waste connection from W. B.Sink, floor drains etc.Make: Pipe:VECTUS/Kissan/AKG |
| 41 | 40 mm outer dia |
| 42 | 63 mm outer dia |
| 43 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings complete including jointing with solvent cement including cutting and making good the walls wherever required. (For soil, waste, vent & rain water pipes). Nothing extra will be paid for supports. |
| 44 | 110 mm outer dia |
| 45 | 150mm outer dia |
| 46 | Cutting holes in RCC beam/Slab by diamond cutting technique.(Nothing extra payable for electrical and water supply required for the cutting operations) |
| 47 | 102mm dia Hole in 125mm thick slab |
| 48 | 152mm dia Hole in 125mm thick slab |
| 49 | Providing and fixing push fit floor clean plug of Upvc pipe. |
| 50 | For 110 OD Pipe |
| 51 | Water supply ( contractor Should make nipples from the same class of pipe, Readymade nipples will not be allowed |
| 52 | Providing and fixing 3 layer PP-R(Poly propylene Random copolymer) pipes SDR 7.4 UV stabilized & anti-microbial fusion welded, having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge.(Make:Vectus,PRINCE) |
| 53 | PN-16 Pipe, 20mm OD |
| 54 | PN-16 Pipe, 25mm OD |
| 55 | PN-16 Pipe, 32mm OD |
| 56 | PN-16 Pipe, 40mm OD |
| 57 | PN-16 Pipe, 50mm OD |
| 58 | Providing and placing on terrace (at all floor levels) 4 Layer polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (5000 +5000 ltrs.)Make: VECTUS/SINTEX |
| 59 | Providing and Fixing of Tanky Nipple G.I 25mm |
| 60 | Providing and fixing Bal valve 25 mm |
| 61 | Union 25 mm |
| 62 | Elbow 25mm |
| 63 | Tee 25 mm |
| 64 | External Water supply and Sewerage system |
| 65 | Providing and fixing G.I. Pipes complete (I:S 1239 Heavy class) with G.I. Fittings e.g.elbows, tees , reducers, unions , plugs etc. and clamps and jointing with holdtite or loctite tape including painting with two coats of synthetic enamel paint, chase cutting and making good the walls etc. wherever required for waste connection from W.B., Urinals, floor drain etc. including painting two coats of bitumastic paint over GI pipe and wrapping of one layer of 200 micron thick LDPE tape and finally a coat of bitumastic paint 32 mm Nominal bore |
| 66 | Exteranl Sewerage system |
| 67 | Providing and constructing brick masonry rectangular type manholes with 100 class designation bricks in cement mortar 1:5 (1 cement : 5 coarse sand) inside and outside 12mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand)with a floating coat of neat cement on inside surfaces, 15 cm thick PCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) for fixing manhole frame; foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate of 40 mm nominal size) including making channels and benching in cement concrete 1:2:4 mix (1 cement : s neatly finished complete as per standard design.(Nothing shall be payable for excavation, refilling and disposing off surplus earth as required by Engineer-in-charge) |
| 68 | 450x450x450mm manholes with FRP manhole cover and frame (heavy-duty) |
| 69 | 600x600x600mm manholes with FRP manhole cover and frame (heavy-duty) |
| 70 | Making soak pit 2.5m diameter3.5m deep Dry tone massonary incl RCC Sab 1 : 1.5 : 3 complete job |
| 71 | Providing and fixing in position polyethylene septic tank type-B (Comfort or equivalent ) having capacity for 20 users, 47\\"x51\\"x119\\" inches in size, including excavation of put as per the size, providing and laying of 150mm thick bed concrete in 1:4:8 mix (1: cement:4 course Sand :8 graded stone agg 20mm nominal size) filling the septic tank with fresh water, connecting the inlet and outlet with the septic tank and filling the dry course of sand and bajre around the septic tank complete Job including carriage of all materials involved |
| 72 | Electric part |
| 73 | Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS/HFFR PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS/HFFR PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit. |
| 74 | Supply, Installation, Testing and Commissioning of 18W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro). |
| 75 | Supply, Installation, Testing and Commissioning of 50W (Havells/ PhillIps/Wipro skyline ) new generation energy saving and environmental friendly long life L.E.D Flood Light made up of pressure die cast Aluminum housing with high efficiency LEDs as lighting source with efficacy >110lm/w ,CRI>80 ,CCT>5000 ,Avg Life L70 50000 hours ,No haremful UV and IR radiators, Operating Temp -10 to 45C ,Surge Voltage Protection, IP66 Protection and impact resistance of IK07.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. |
| 76 | Supply, installation, testing and commissioning of 400 mm BEE Star rated energy-efficient wall fan, complete with 3 Nos. blades, capacitor,front guard,spinner,rear guard,guard ring,wall mounting bracket and washers, suitable for 230 V, 50 Hz AC supply. air flow 2400-2500cfm,blade pitch 120 degree, rated speed (RPM) between 1300–1400 (as per manufacturer’s specification), power consumption not exceeding 60 watts, service value ≥ 6.0, noise level ≤ 60 dB, insulation class ‘B’ and insulation resistance > 2 MΩ. Fan shall be of approved make such as Usha / Havells / Crompton / Orient/ V- Guard or equivalent, including installation, online RPM verification, testing, commissioning and handing over to the Engineer-in-Charge, with minimum 2-year manufacturer warranty. |
| 77 | Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC) |
| 78 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 79 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena make). |
| 80 | Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) excluding the cost of conduit. |
| 81 | Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required excluding the cost of conduit. |
| 82 | Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent). |
| 83 | Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired. |
| 84 | Supply and fixing of 8 way (4+24), Double door surface/ recess mounting, Horizontal type,three pole and neutral, sheet steel, MCB distribution board ,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB) |
| 85 | Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCBdistribution board complete with necessary connections. |
| 86 | Supply, installation, testing and commissioning of 32A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 87 | Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 88 | Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA \\"C\\" curve MCB of Legrand/ Havells/ L&T/ABB suitable for inductive load in the MCB distribution board complete with necessary connections. |
| 89 | Main Panel |
| 90 | Design, fabrication, supply, installation, testing, and commissioning of Main Distribution Board (MDB), duly manufactured from CPRI-approved manufacturer, made out of 12 SWG CRCA (IS 375) mild steel sheet, 2 mm thick, powder-coated with RAL 7035, floor/wall-mounted, vermin and dust-proof, indoor type. The panel shall be provided with suitable size angle iron legs for grouting in the ground, lockable hinged doors, and painted finish. The enclosure shall have provisions for fixing switchgears,Aluminium bus bars of various ratings (considering derating factor), and other allied accessories as required. The panel shall be fabricated as per approved design; size may vary according to site requirements. The panel shall fully comply with IS 8623 / IEC 61439 standards for low voltage switchgear assemblies.The work includes all internal wiring, thimbles, ferrules, nuts, bolts, washers, gland plates, earthing lugs, insulation sleeves and all other accessories necessary to complete the panel in all respects as per site requirements.” |
| 91 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 92 | 1. Normal INCOMING: |
| 93 | a)125A DP MCB 10 KA Havells/Legrand/ Schinider/ABB/L&T sample to be approved before installation.. |
| 94 | b) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 95 | c)Digital meters and phase indicators -1 set. |
| 96 | 2.INVERTER |
| 97 | a) 32A DP MCB 10KA |
| 98 | b) 2 No. of Aluminium Bus Bar of 63 Amp. |
| 99 | c) Digital meter and phase indicators 01 set. |
| 100 | Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, excluding the cost of conduit. (Havells/ Polycab/ Finolex/ Anchor/KEI/RR or equivalent). |
| 101 | 2x10 sq mm +1x6 sq mm Heating submain |
| 102 | 2x 6 sq mm + 1x 6 sq mm Lighting submain |
| 103 | 2x 4 sq mm + 1x 4 sq mm Inverter submain |
| 104 | 2x 2.5 sq mm + 1x 2.5 sq mm inverter & normal Circuit |
| 105 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job. |
| 106 | Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 107 | Supply, laying, connecting and commissioning of 16 sq mm 2 core XLPE/ PVCInsulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped. (Over head/ under ground). |
| 108 | Supply and fixing of 25mm wide Medium Class PVC Casing & Capping (FRLS type) with necessary accessories such as saddles, couplers, tees, bends, and junction boxes, complete as per specifications. |
| 109 | Supplying,Laying and fixing of Suitable Fan Junction Box in Slab.sample to be approved by EIC |
| 110 | Providing and fixing of Deep boxes for lights in Slab,sample to be approved by EIC |
| 111 | Supply, installation, testing and commissioning of 2000 VA (2 kVA), 12 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 220 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring to DB, initial charging, commissioning, and all accessories, duly approved by Engineer-in-Charge. Please Enable Macros to View BoQ information |