Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-04-2026 | Amendment in Tender Document | Technical Bid | 02-05-2026 |
| Sl. No. | Item Description |
| 1 | Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m.Disposed earthto be levelled and neatly dressed. |
| 2 | Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete.(A) Moorum / Hard Copra |
| 3 | Filling in trenches with available excavated earth in layer not exceeding 20cm in depth consolidating each deposited layer by ramming & watering. |
| 4 | Supplying and filling in plinth under floors including, watering, ramming consolidating and dressing complete.(A) Crusher Stone Dust |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-10 (Nominal Mix)with 20 mm maximum size of stone aggregate. Footing and plinth Beam. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. Cement concrete grade M-15( Nominal Mix)with 20 mm maximum size of stone aggregate. Grade slab |
| 7 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding up to floor level including cost of binding wire, wastage and over laps upto 12 mm horizontal / inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical leng th of reinfor cement in wall columns (over laps shall be provided as per requirement of IS: 13920 ; IS456 &SP: 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)Ground Floor |
| 8 | Providing and laying in position machine batched and machine mixed and machine vibrated design mix cement concrete of M-25 grade mixed in aconcrete mixer of not less than 0.2 cum capacity and approporiate weigh batcher using approved mix design, for reinforced cement concrete work inluding pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retards etting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.( A ) Upto Plinth level |
| 9 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plate or plywood shuttering for : Foundations, footings, bases of columns, etc. For mass concrete. |
| 10 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 11 | Walls (any thickness) including attached pilasters, butteresses, plinthand string courses etc. |
| 12 | Brick work with fly ashlime bricks (FALG Bricks) conforming to IS:12894- 2002, class designation 50 (average compressive strength)upto plinth level : Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 13 | 18mm cement plaster in two coats under layer 12mm thick cementplaster 1:5(1 cement: 5 coarse sand) finished with a top layer 6mmthick cement plaster 1:4 (1 cement: 4 fine sand). |
| 14 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diametre holes and plugging with cement mortar 1 :2 (1 cement : 2 sand) to match the existing floor, With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. ATT Tretment for Plinth. |
| 15 | Labour charge for Trimix vacuum dewatering process for concrete and cost of fixing, removing of “C” Channel formwork including using vacuum dewatering machine machine finished as directed including light brooming and curing including making construction joint by cutting of joint of by using of concrete cutter machine. For 100 mm thickness. |
| 16 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding up to floor level including cost of binding wire, wastage and over laps upto 12 mm horizontal / inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical leng th of reinfor cement in wall columns (over laps shall be provided as per requirement of IS: 13920 ; IS456 &SP: 34) etc. complete.Thermo-Mechanically Treated bars. (Fe 500 D or more)-Ground Floor |
| 17 | First Floor Add extra for providing reinforcement above Floor two level for every additional floor or part there of - 1% of the respective item |
| 18 | Second Floor |
| 19 | Third Floor |
| 20 | Fourth Floor |
| 21 | Fifth Floor |
| 22 | Sixth Floor |
| 23 | Seventh Floor |
| 24 | Mumty Floor (Stair cabin) |
| 25 | (Lift Machine room) |
| 26 | Providing and laying in position machine batched and machine mixed and machine vibrated design mix cement concrete of M-25 grade mixed in aconcrete mixer of not less than 0.2 cum capacity and approporiate weigh batcher using approved mix design, for reinforced cement concrete work inluding pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement. including Admixtures in recommended proportions as per IS 9103 to accelerate, retards etting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Ground Floor |
| 27 | First floor |
| 28 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 29 | Third Floor |
| 30 | Fourth Floor |
| 31 | Fifth Floor |
| 32 | Sixth Floor |
| 33 | Seventh Floor |
| 34 | Mumty Room (Stair cabin) |
| 35 | (Lift Machine room) |
| 36 | (B)Beams, Girders and cantilever Having cros sectional area more than 0.08 sq. mt and upto 0.12 sq.mt.Ground Floor |
| 37 | First Floor |
| 38 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 39 | Third Floor |
| 40 | Fourth Floor |
| 41 | Fifth Floor |
| 42 | Sixth Floor |
| 43 | Seventh Floor |
| 44 | Mumty Room (Stair cabin) |
| 45 | (Lift Machine room) |
| 46 | (C) Slabs having more than 10 Cm & upto 13 Cm thickness.Ground Floor |
| 47 | First Floor |
| 48 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 49 | Third Floor |
| 50 | Fourth Floor |
| 51 | Fifth Floor |
| 52 | Sixth Floor |
| 53 | Seventh Floor |
| 54 | Mumty Room (Stair cabin) |
| 55 | (Lift Machine room) |
| 56 | ( D ) Lintels Ground Floor |
| 57 | First Floor |
| 58 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 59 | Third Floor |
| 60 | Fourth Floor |
| 61 | Fifth Floor |
| 62 | Sixth Floor |
| 63 | Seventh Floor |
| 64 | Mumty Room (Stair cabin) |
| 65 | (Lift Machine room) |
| 66 | (E) STAIR CASE-Ground Floor |
| 67 | First Floor |
| 68 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 69 | Third Floor |
| 70 | Fourth Floor |
| 71 | Fifth Floor |
| 72 | Sixth Floor |
| 73 | Seventh Floor |
| 74 | ( F ) Chhajja First Floor |
| 75 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 76 | Third Floor |
| 77 | Fourth Floor |
| 78 | Fifth Floor |
| 79 | Sixth Floor |
| 80 | Seventh Floor |
| 81 | Mumty Room (Stair cabin) |
| 82 | (Lift Machine room) |
| 83 | (G) RCC Wall / PardiGround Floor |
| 84 | First Floor |
| 85 | Second Floor ExtraforR.C.C./B.M.C./R.M.C. allworksabovefloor2 level foreach floors or part thereof. |
| 86 | Third Floor |
| 87 | Fourth Floor |
| 88 | Fifth Floor |
| 89 | Sixth Floor |
| 90 | Seventh Floor |
| 91 | Mumty Room (Stair cabin) |
| 92 | Centering and shuttering including strutting, propping stretching etc. complete for and removal of formwork by sheet plate or plywood shuttering for : Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 93 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 94 | Suspended floors, roofs, landings, balconies and access platform. |
| 95 | Stairs, (excluding landings) except spiral-staircases. |
| 96 | Walls (any thickness) including attached pilasters, butteresses, plinthand string courses etc |
| 97 | Providing and laying Autoclaved Aerated Concrete (AAC) blocks masonary, using AAC blocks (Size length 300, 400, 500, 600 Height 200, 250, 300 Width 100, 150, 200, 250mm) conforming to IS:2185 PART-3, having compressive strength not less than 3Mpa (GradeH) in superstructure, blocks jointed with cement mortar 1:6(1cement:6sand) or with polymer modified cement mortar as per ASTM 1660-09, applied in uniform thickness of 2 to 3mm in horizontal and verticals joints using special trowel, polymer modified mortar having minimum compressive strength and minimum splitting tensile strength of not less than 5MPa and 0.34MPa respectively as per ASTM international standard including raking out joints. The surface of masonary units (AAC-Block) should be slightly moist prior to application of jointing mortar. Block should be gently pressed down using a rubber mallet to expeloutent rapped air and the masonary shall be carried for even days for cement mortar and two days for polymer modified mortar. Ist layer of masonary block shall be placed on perfectly leveled surface, which if required, shall be leveled with M-20 cement concrete at plinth or floorlevel. Masonary shall have 75mm thick RCC band with M-20 cement concrete and 2 bars of 8mm dia. Such bands shall be spaced at interval of 1.8meter in vertical direction. RCC bands shall be measured with AAC block masonary. Rates include all materials including steelbars wastage, scaffolding and all labour etc. complete upto floor two level :AAC masonary in cement mortar 1:6 (1 cement : 6 sand)Ground Floor |
| 98 | First Floor |
| 99 | Second Floor |
| 100 | Third Floor |
| 101 | Fourth Floor |
| 102 | Fifth Floor |
| 103 | Sixth Floor |
| 104 | Seventh Floor |
| 105 | Mumty Floor (Stair cabin) |
| 106 | (Lift Machine room) |
| 107 | 12mm cement plaster finished with a floating coat of neat cement ofmix : 1:4 (1 cement: 4 sand).Ground Floor |
| 108 | First Floor |
| 109 | Second Floor - Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3 m or part thereof. |
| 110 | Third Floor |
| 111 | Fourth Floor |
| 112 | Fifth Floor |
| 113 | Sixth Floor |
| 114 | Seventh Floor |
| 115 | Mumty Floor (Stair cabin) |
| 116 | 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand) -Ground Floor |
| 117 | First Floor |
| 118 | Second Floor - Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3 m or part thereof. |
| 119 | Third Floor |
| 120 | Fourth Floor |
| 121 | Fifth Floor |
| 122 | Sixth Floor |
| 123 | Seventh Floor |
| 124 | Mumty Floor (Stair cabin) |
| 125 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1cement: 5 coarse sand) finished with a top layer 6mmthick cement plaster 1:4 (1 cement: 4 fine sand).-Ground Floor |
| 126 | First Floor |
| 127 | Second Floor - Extra for plastering exterior walls of height more than 10m from ground level for every additional height of 3 m or part thereof. |
| 128 | Third Floor |
| 129 | Fourth Floor |
| 130 | Fifth Floor |
| 131 | Sixth Floor |
| 132 | Seventh Floor |
| 133 | Mumty Floor (Stair cabin) |
| 134 | (Lift Machine room) |
| 135 | Providing plaster drip course /groove in plastered surface or mouldingto R.C.C. projections. |
| 136 | Providing gola 75x75mm in cement concrete M-15 with aggregate 10mm and downgauge including finishing with cement mortar 1:3 (1cement :3 fine sand) as per standard design : In 75x75mm deep chase. |
| 137 | Providing and fixing chicken mesh as per ISI specification and in the required width with 50mm long Bombay nail sonvertical and horizontal junctions of RCC and brick wall including scaffolding and all lead and lift etc. complete before plastering upt 10 meter height. |
| 138 | Providing and laying vitrified floor tiles Multi/Dobule charged (Minimum top layer thickness 2.0mm) Neno Polished self design, in different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades Ist preminum quality in flooring laid on 12mm thick cement mortar 1:4 (1cement: 4sand) including grouting the joints with white cement and matching pigments etc. complete. (thickness as per manufacturer specification) |
| 139 | Providing and laying vitrified floor tiles Multi/Dobule charged (Minimum top layer thickness 2.0mm) Neno Polished selfdesign, in-different size with water absorption less than 0.05% and conforming to IS:15622 of approved make in all colours & shades Ist preminum quality in skirting laidon 12mm thick cementmortar 1:4 (1 cement:4 sand) including grouting the joints with white cement and matching pigments etc. complete. (thickness as per manufacturer specification) |
| 140 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (6 to 7mm thick) of approved make in all colours, shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:3 (1cement:3 coarse sand) and jointing with grey cement slurry including pointing in white cement mixed with pigment of matching shade complete. |
| 141 | Providing and laying Ceramic glazed floor tiles 300x300mm or more (6 to 7mm thick) of 1st quality conforming to IS:15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20mmthick Cement Mortar 1:4 (1Cement:4Coarsesand) including pointing the joints with white cement and matching pigment etc. complete. |
| 142 | Kota stone slabs 25mm thick in risers of steps, skirting, dado and pillars laid on 12mm (average) thick cement mortar 1:3 (1cement :3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 143 | Granite work gang saw cut (polished and machine cut)of thickness 18mm for walllining (veneerwork), backingfilled with a grout of average 12mm thick in cement mortar 1:3 (1cement: 3sand) including pointing with white cement mortar 1:2(1whitecement: 2 marbledust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). Fine granite dark Black/dark Red/ White with self design/ pattern/ crystals of other colors of glitter. Fine granite dark Black/dark Red/ White with self design/ pattern/ crystals of other colors of glitter.Area of slab upto 0.50 Sqm |
| 144 | Granite work gang saw cut (polished and machine cut)of thickness 18mm for walllining (veneerwork), backingfilled with a grout of average 12mm thick in cement mortar 1:3 (1cement: 3sand) including pointing with white cement mortar 1:2(1whitecement: 2 marbledust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). Fine granite dark Black/dark Red/ White with self design/ pattern/ crystals of other colors of glitter. Fine granite dark Black/dark Red/ White with self design/ pattern/ crystals of other colors of glitter.Area of slab over 0.50 Sqm |
| 145 | Extra for providing opening of required size & shape for washbasins/ kitchens in kitchen platform, vanity counters and similar location inmarble /Granite /stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. |
| 146 | Providing and fixing 35mm thick factory made laminated veneer lumber door shutter conforming to IS:14616 and TADS 15:2001 (PartB) including ISI marked M.S.pressed bright finished but thinges with necessary screws as per directions of Engineer and panelling with panels of: 12mmthickpre-laminated particle board(decorative lamination on bothsides) grade-1, medium density flat pressed, three layer particle board FPT-Ior graded wood particle board FPT-I, conforming to IS:3087 bonded with BWP type syntheticresin adhesive as per IS:848 and pre-laminated conforming to IS : 12823 Grade 1, Type - II marked: |
| 147 | Providing and fixing35mmthick factorymade laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B) including ISI marked M.S. pressed bright finishedbutt hinges with necessaryscrewsasper directionsof Engineer and panelling with panels of: 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade- 1mediumdensity flat pressed, threelayer particle board FPT- I or graded wood particle board FPT-1 conforming to IS : 3087 bondedwithBWP typesynthetic resin adhesive as per IS : 848andpre-laminated conforming to IS : 12823 Grade -1, Type II marked: |
| 148 | Providing and fixing in position factory made pre-cast RCCM-40 doors and windows frames having excellent smooth finish as per IS:6523 with reinforcement of 3Nos, 6mm diama in barstied with 3mm M.S stirrups placed@200mm C/C and 6number shigh strength polymer blocks of required size for fixing hinges including providing 6no specially designed M.S. galvanised sleeves for accomodating 6mm diafully threaded bolts for fixing hold faston vertical members, providing suitable arrangement for recieving sliding door bolts and tower bolt etc. all complete, as per the direction of Engineer-in-charge. (The cost of hold fast and Cement Concrete block of 1:3:6 (1 Cement: 3 sand: 6 Graded stone agreegate 20mm nominal size) mix is also included in the item.)The frame shall be measured in running meter correct to two places of decimal. Door frame 125 mmx 60 mm |
| 149 | 24 mm thick factory made PVC door shutters made of style sand rails of a UPVC hollow section of size 59x24 mm and wall thickness 2mm ± 0.2mm with inbuilt edging on both sides.The style sand ails mitred and joined at the corners by means of M.S. alvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. Thestyles of the shutter einf or cedby in serting galvanised M.S. tube of size 20x20 mm and 1 mm ±0.1 mm wall thickness. The lock rail made up of 'H' section, a UPVC hollow section of size 100 x 24mm and 2mm± 0.2 mm wall thickness fixed to the shutter styles by means of plastic / galvanised M.S. 'U' cleats. The shutter frame filled with a UPVC multi chambered single panel of size not less than 620mm, having over all thicknessof 20mmand 1mm±0.1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanised M.S. rod and fastened with nut sand washers, complete as per manu facturer's specification and direction of Engineer-in- charge. (For W.C. and bathroom door shutter). |
| 150 | Providing and fixing factorymade UPVC door framemade of UPVC extruded section having an overall dimension as below tolerance±1mm)with wall thickness 2.0mm± 0.2mm, corners of the door frame to be mitred and welded of plastic, galvanized brackets and stainless steelscrews. The hinge side vertical of theframes reinforced bygalvanizedM.S. tubeofsize19 X19mmand1mm±0.1mmwall thicknessand3nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge - Extruded section profile size 42x50 mm. |
| 151 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built-up standard tubular sections/ appropriate Z-sections and other sections of approved make conforming to IS:733 and IS:1285, fixed withrawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gap sat junctions, at top, bottom and sides with required PVC/ neoprenefelt etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleatangle, Aluminium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and paneling to be paid for separately) : For shutters of doors, window & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC/ neoprenegasket required (Fittings shall be paid for separately). |
| 152 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding. |
| 153 | Providing and fixing 16mm M.S.F anclamps of standard shape and size in existing R.C.C. slab including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 154 | Providing and applying 1.0mm thick white cement based wall putty of best quality, over plastered surface top repare the surface even and smooth complete. |
| 155 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats on walls applied @1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr/10 sqm. |
| 156 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a)after surface preparation, first layer of slurry of cement@ 0.488 kg/sqm mixed with water proofing cement [email protected] kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer isstill green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5mm thickness consisting of slurry of cement@ 1.289kg/sqm mixed with water proofing cement [email protected] kg/sqm and coarses [email protected]/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around. |
| 157 | Providing and layingwater proofing treatment in sunken portionof WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a)First layerof slurry of [email protected]/sqm mixed with water proofing cement compound 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @0.242kg/sqm mixed with water proofing cement [email protected]/sqm. This layer will be allowed to aircure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 158 | Brick Bats |
| 159 | Steel work in built up M.S. tubular section (round, square or rectangular Hollow tube etc.) trusses / frame work etc. / railing work etc. including cutting, hoisting fixingin position and applying apriming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. |
| 160 | Painting Steel work with Deluxe Multi Surface Paint to givean even shade. Two or more coat applied @0.90 ltr /10 sq move ranunder coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 161 | R.C.C. Ground Service Reservoirs & Sumps Cost of 1,00,000 Litres Capacit - Fire tank |
| 162 | R.C.C. Ground Service Reservoirs & Sumps Cost of 2,50,000 Litres Capacity- UGW Tank |
| 163 | R.C.C. Ground Service Reservoirs & Sumps Cost of 1,00,000 Litres Capacit - Fire tank |
| 164 | Providing, erecting and giving test of Centrifugal Mono block pump set conforming to IS 9079 operating at 2900 RPM with CI impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415V ±10%, 3Ph, 50 HzA.C. Supply. Motor shall beTEFCtype.Pumpset shall be suitable for working at various discharge and headre quirements.Pump shall be erectedon Provided C.C. foundation block with suitable foundation bolts grouted in C.C. foundation block. Centrifugal Monoblock Pump set (Single Stage) |
| 165 | Clearing and grubbing road land including up rootingr and vegetation, grass, bushes, shrubs, saplings andt reesgirth upto 300mm,remova lof stumps of trees cutear lieranddisposal of unserviceable materia lsand stacking of serviceable material to beused o rauctioned upto alead of 1000 meter including removal and disposa lof toporganicsoil not exceeding 150mm in thickness ifrequired and asperrelevantclauses of section-200. In area of light jungle |
| 166 | Excavation for roadway in ordinary Soil with hydraulic excavator including cutting and loading in tippers, transporting to embankment site with in all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections as per relevent clauses of section-300 of specification. |
| 167 | Providing and layin gnon-pressure NP2 class (light duty) R.C.C.pipes collar jointe dwithstiff mixture o fcement mortar in the proporti on of1:2 (1 ement: 2 fine sand). |
| 168 | Construction of granular sub-base spreading in uniform layers with motor grader on prepared surface, mixing by mixing place method at OMC and compacting with vibratory roller of 80-100KN Static weight to achievethedesireddensity, complete in all respect as per relevant clauses of section-400.Grading III |
| 169 | Construction of Dry Lean Cement Concrete Sub- Base Over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per Table 600-1 of the specifications, cement content not to be less than 150 Kg/Cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 MPa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per Section 601 of specifications. |
| 170 | Construction of Dowel jointed, Plain Cement Concrete Pavement in M-30 Grade Concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to IS:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor spreading the concrete by shovels, rakes compacted using needle, screed and plate vibrator and finished in a continuous operation including provision of contraction, expansion, and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar, tie rod admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per IRC:15 and as per Section-602 of the specifications complete excluding cost of steel in dowel bar and tie rod etc. |
| 171 | Providing and laying factory made Coloured Chamfered Edge Cement Concrete Paver Blocks of required strength, thickness and size/shape, made by table vibratory method using PU mould, laid in required colour and pattern over 50mm thick compacted bed of stone dust, compacting and proper embedding/laying of inter locking paver blocks into the bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including locking edges with M 15 Cement Concrete in in footpath, light traffic parking etc. complete as per direction of Engineer-in-Charge.80mm thick C.C. paver block of M-35 grade with approved colour, design and pattern. |
| 172 | Speed BreakerProviding and laying of Parabolic Shaped Transverse Rumble Bar Marking using Plastirib 3k, 3 Component Cold Plastic Road marking material in single onolithic application to create rumble strip raised ection 20 mm high, 500 mm wide and spaced about 1 meter centre to centre of roughly 6 numbers at one ocation, across the entire carriageway. Each rumble arking shall be made complete with high refractive rop on glass beads (Ri > 1.6), spread at 350 gm / sqm o ensure high retro reflectivity throughout the surface of arking. The finished surface shall be levelled, uniform, ree from starks and holes including surface cleaning nd cost of all materials etc. complete. As per IRC 99, these rumble strips shall be applied for speed reduction and traffic calming measures. |
| 173 | Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year). |
| 174 | Providing and planting different variety of plants of approved quality and sizes as mentioned including making pits of required size at site, refilled with B.C. Soil mixture manuring and pesticide etc. complete (to be paid separately) including watering and 90 days maintenance from the date of final bill as per direction of Engineer-inCharge complete in all respect (B.C. Mixture paid separately).'Bahunia Tomentosa, Beloperone Species, Caselpinnia Pulcherima, Caliandra Emarginata, Callandra Hybrida, Cassia Bi flora, Cassia Laevigata, Cestrum Nocturnum, Dombeya Mastersii, Euphorbia Caracasana, Euphorbia Pulcherima, Excorea bi color, Excorea tri color, Ficuas Blackii, Ficus Reginold, Ficus Panda, Gardenia, Gulphinia, Jasminoides, Hamelia Pattens, Heliconia,Hibiscus Rosasinensis, Hibiscus Verigated, Hibiscus Viceroy, Jatropha Multifida, Largestomia Indica, Malpighia Coccigera, Murraya Exotica, Murraya Koeniggi, Murraya Sambucum, Mussaenda Erythrophylla, Nerium Oleander, Nyctanthus Arbortristis, Plumbego Capensis, Putranjeeva Roxburghii,Tabernaemontana Coronaria, Tabernaemontana Divaricata, Tecoma Gaudi Chaudi, Tecoma Stans, Thevetia Nerifolia, Thuja Compacta and equivalent plants |
| 175 | Allamanda Cathartica, Allamanda Grandiflora, Allamanda Violacea, Begnonia Venustha, Boughan Villas (Variety : Butiana, Lady Mary Bearing, Mahaara, Mohan, Scarlet Queen Variagata, Glabra Formosa, Peruviana Odissi, Partha, Shubhra, Thimma, Spectabillis, L.N. Birla, Refulgens), Clerodendrum Splendens, Clerodendrum Thompsonae, Ipomea Purpurea, Jasminum Grandiflorum, Jasminum Humile (Yellow), Passiflora Caerulea (Rakhi Bel), Petrea Volubilis, Quis Qualis Indica, Tecoma Grandiflora, Veronia Elaegnifolia (Curtain Creeper), Mandvellia, Garlic Creeper, Callimitis |
| 176 | Grassing with ‘Doob’ grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for mowing. (if needed the good earth shall be paid separately). |
| 177 | Making Lawns including Ploughing and Dragging with ‘Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass or any other variety of grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 Sqm) including as directed by Engineer-in-Charge. |
| 178 | Maintenance of Lawns or Turfing of Slopes (Maintenance of lawns or turfing of slopes (rough grassing) for a period of one year including watering etc). |
| 179 | Providing and fixing of 3 seater stone bench made of 75mm thick stone slab finished by different numbers of ambry stone and two coats of 124 nos ealer coat to prevent from weather including fixing ona pedestal (cost of pedestal to be paid separately) etc. complete as per direction of engineer in charge. Size: length 1500mm, width 600mm, legs height 500 mm, back support height 500mm. |
| 180 | Lettering & painting block numbers in Required size and shape on wall in three coats with approved quality of oil paint incl. cleaning, brushing & scraping the surface as per inst. of engineer in-charge. Height of letter shall be 8 cm x 12 mm. |
| 181 | Providing and fixing white vitreous china water closet squatting pan (Indian type) P or S trap, complete including cutting and making good the walls and floors wherever required :Long pattern W.C. pan of size 580 mm |
| 182 | Providing and fixing controlled flush, low level cisternmade of vitreous china with all fittings complete.10 litre (full flush) capacity-white |
| 183 | Providing and fixing wash basin with C.I.brackets,15mm C.P. brass pillar taps,32mm C.P.brass waste of standard pattern, including painting of fitting sand brackets,cutting and making good the walls wherever require :White Vitreous China Wash basinsize 630x450mm with a pair of 15 mm C.P. brass pillar taps. |
| 184 | Providing and fixing Stainless SteelAISI304(18/8)kitchen sink as per IS13983 with C.I.brackets and stainless steel plug 40 mm including painting of fittings and brackets , cutting and making good the walls wherever required :Kitchen sink with drain board(510x1040 mm bowl depth 250mm.) |
| 185 | Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260gms. |
| 186 | Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 165mm long. Weighing not less than 110 gms. |
| 187 | Providing and fixing PTMT angle stop cock 15mm nominal bore.Wieghing not less than 85 gms. |
| 188 | ProvidingandfixingPTMTswivelling shower,15mmnominalbore,wieghing not less than 40 gms. |
| 189 | Providing and fixing unplasticised PVC soil and waste pipes conforming to IS: 13592 Type B including jointing with seal ring conforming to IS :5382 leaving 10mm gap for the rmal expansion. Single socketed pipes for working pressure of 4 kg/sqcm.75 mm diameter (minimum wall thickness 3.2mm) |
| 190 | 110 mm diameter (minimum wall thickness 3.2mm) |
| 191 | Providing and fixing on wall faceun plasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mmgap for thermal expansion. (i) Single socketed pipes.110 mm dia. PVC SWR socketed pipe with rubber ring joints as per IS:13592 Type-A |
| 192 | Road Gully Chambers :- Construction of Brick masonry road gully chambers with brick work in cement mortar 1:5 (1 cement: 5 course sand ) and 12mmplaster 1:3 including foundation incement concrete grade M-5 (Nominal Mix) with stone aggregate 40mm nominal size Including precast reinforced cement concrete top cover and frame. (As per Drawing No. 18) Chamber 45x45x77.5cm with vertical grating 450x100 mm size |
| 193 | Constructing Brick masonry rectangular manhole in cement mortar1:4(1cement: 4 fine sand) common Burnt Clay Brick or flyash bricks, of compressive strength not less than75 Kgf/ cm2 RCC top slab Cement Concrete 1:2:4 (Nominal Mix) with stone aggregate 20mm nominal size, 20cm thick foundation in cement concrete 1:3:6 (Nominal Mix) with stone aggregate 40mm nominal size, inside & out side plastering minimum12 mm thick with cement mortar 1:3 (1cement:3 coarse sand) finished with a floating coat of neat cement and making channels in Cement Concrete 1:2:4 (Nominal Mix) with stone aggregate 20mm nominal size including finishing the channel to shape, including providing and fixing footrest, manhole cover and frame etc. complete. (only excavation as per actual shall be paid separately) ,Depth of manhole shall be considered as the vertical distance fromtopof themanhole cover to the outgoing in vert of main drain channel. (for reference purpose use Drawing No. 11)-Manhole with above specification shaving inside size 120x90 cm and 90cmdeep includingC.I. cover with frame (medium duty) 500 mm clear opening as per IS 1726 : 1991. |
| 194 | Excavation of trench for laying of pipe for water harvestingat ground floor and refilling watering and ramming the average depth of trenchis 0.65 meter. Excavation for 90mm |
| 195 | Providing and laying nonpressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe |
| 196 | 300 mm dia. R.C.C. pipe |
| 197 | 450 mm dia. R.C.C. pipe |
| 198 | 500 mm dia. R.C.C. pipe |
| 199 | 600 mm dia. R.C.C. pipe |
| 200 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineerin- Charge. Concealed work including cutting chases and making good the walls etc.15 mm nominal outer dia .Pipes. |
| 201 | 20 mm nominal outer dia .Pipes. |
| 202 | 25 mm nominal outer dia .Pipes. |
| 203 | 32 mm nominal outer dia .Pipes. |
| 204 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This included jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer-in- Charge. External Work -40 mm nominal outer dia .Pipes. |
| 205 | 100 mm nominal outer dia .Pipes. |
| 206 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length 15 mm nominal bore |
| 207 | Cutting holes upto 30x30 cm in walls including making good the same : With common burnt clay bricks of 25 kg /sqcmor flyash bricks of 50 kg/cm2compressive strength. |
| 208 | Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 209 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertion setc .complete (The tail pieces, tapers etc if required will be paid separately)-80 mm Diameter |
| 210 | 100 mm Diameter |
| 211 | Providing & fixing PTMT Ball cock of approved quality, colour and make complete with epoxy coated aluminum rod with LP/HDPE plastic ball-40 mm Diameter |
| 212 | 50 mm Diameter |
| 213 | b) Primary & Secondary Treatment - with digesters, sludge drying beds-10 MLD |
| 214 | Carryingout there sistivity survey by VES method using Schlum berger configuration for locating the proper spot for drilling of tubewell with in the selected habitation, including Photography, interpretation of resistivity data and submission of report in thedesired format alongwith resistivity necessary graph, photographs and readings |
| 215 | Drilling of perfectly vertical bore hole of a diameter suitable to receive 200mm nominal diameter casing pipe upto desired depth below ground level inclusive of the labour charges for transporting, loweringand fixingof 200mmnominal diameter M,S. /G.I ./U.P.V.C. casing pipe in side the bore hole includingall works pertaining todrilling suchas transportation, installationand removal of drilling machine etc. complete.in all types of rocks. |
| 216 | Providing and fixing of well capontop of thetube well for protectio |
| 217 | Installation of HDPE/ DWCPE/ PVC-O pipe by Horizontal Direction Drilling Method including preparing and setting up the plantand equipment, making string of new pipe material, installing new pipe string and making the system ready for commissioning by HDD operation including drilling, stringing, reaming and pulling back the new pipe on the designed bore path alignment, proper disposal of drilling fluid, as per code of practice for horizontal direction drilling technique suitingindi an conditions .Required pipes/ specials and ot her civil work shall be paid separately-inall typesof soils and depth upto 1.00m.HDPE pipe of any class-110 mm outer dia |
| 218 | Providing,erecting and giving test of submersible pumpset conforming to IS8034 and motor conforming toIS9283,with water proof winding.Pump shall be suitablefor various delivery head and discharg ewith stainlesssteel shaft.Motor suitable for working on 415V±10%,3Ph, 50HzA.C. Supply, with cable guard, thrustcarbon/fiber bearing to with stand entire hydraulic thrust.The pump set shall be suitable for direct coupling,withsuitable suction strainer. Pump should have suitabledischarge out let as per manufacturer's design.Antithrust stream lined non return valve shall beprovided with the pump. 3m submersible copperconductor cable insingle / double runand2pairsofsuitable size erection clamp 10mm thick shall beprovided with each pump. |
| 219 | Providing,erecting and giving test of submersiblepumpse tconforming to IS8034 and motor conforming to IS9283,with water proof winding.Pump shall be suitablefor various delivery head and discharge with stainlesssteel shaft.Motor suitable for working on 415V±10%,3Ph, 50HzA.C. Supply, with cable guard, thrustcarbon/fiber bearing towithstandentirehydraulicthrust.The pump set shall be suitable fordirectcoupling,withsuitable suction strainer. Pump should have suitabledischarge out let as per manufacturer's design.Antithrust stream lined non return valve shall beprovided with the pump. 3m submersible copperconductor cable insingle / double run and2pairsofsuitable size erection clamp 10mm thick shall beprovided with each pump. |
| 220 | Providing and fixingofM.S. bail plug as per I.S.2800 (PART-I) 2001 in the bottom of casingassembly |
| 221 | Supplyingof ISIMarkedDirectOn-LineStartersconfirming toIS:13947-4withsuitableover loadrelayrangeandcontactorsize, 415 V , 3 -Phase with two earthing terminals i) 0.75 / 1.0 / 2.0 / 3.0 / 5.0 / 7.5 HP |
| 222 | Supplying and drawing PVC insulated copper cable ( EarthContinuityConductor ) of Green colour FRwith copper multistrandconductor ISImarked inexistingconduit alongwithotherwires as required as per specification : 6sqmm |
| 223 | Point Wiring in surface rigid P.V.C. conduit system with ModularPoint wiring including metallic switch box, sheet, switches, sockets, lamp holders/ceiling roses etc with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C. conduit (MMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit including painting etc. as required as per specification for :-Light Point/Fan Points.a) Short point |
| 224 | b) Medium point |
| 225 | 3 Pin 6 Amp socket outlet on Separate Boarda) Short point |
| 226 | Call Bell / Buzzer Pointsa) Short point |
| 227 | Twin Control light pointsa) Short point |
| 228 | POWER WIRING IN SURFACE RIGID P.V.C.CONDUIT (HEAVY DUTY) SYSTEM WITH FLUSH TYPE ACCESSORIES Point wiring including metallic switch box, sheet, for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Surface rigid P.V.C.Conduit (HMS) ISI Marked of suitable size including painting etc. with 16 Amp. F.T. Switch & Socket / S.S.Combined 16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for :- (1.5.1) On Separate Board A. Short Point |
| 229 | Circuit WiringWiring for circuit wiring with PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) of ISI marked suitable size including painting etc. as required as perspecificationb) 4x2.5 Sq.mm. |
| 230 | SUB-MAIN IN CONCEALED RIGID STEEL CONDUIT IN COPPER CONDUCTORWiring for sub-mains with PVC insulated cable FR with copper multi strand conductor ISI marked in recessed / concealed rigid steel ISI marked conduit of suitable size(Conduit included) including connectionpainting etc ,as required as per specification 3 1/2 WIRE SUB-MAIN-3 x 6.0 + 1 x 4.0 sq mm cable in 25 mm conduit |
| 231 | Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898 :2002 but without enclosures :-SINGLE POLE (SP)6 Amp to 32 Amp Rating |
| 232 | DOUBLE POLE (DP)-For 40 Amps. Rating only. |
| 233 | FOR TRIPLE POLE & NEUTRAL(TPN)-50 Amp to 63 Amp Rating |
| 234 | Supplying of ISI Marked On-Load Change over switches panelmouniting type confirming toIS:13947(partI&III)withfrontoperated 4 pole, 415 V with two earthing terminals if required.400 Amps. .(open - execution ) |
| 235 | Supplying of ISI Marked and approved make of Moulded CaseCircuit Breaker (MCCB) suitable for 3phase,3pole,50Hz,415Volts,AC supply with respective interrupting capacity(KA)at415Volts cited against their range standard conforming to IS - 8828 MCCB with Breaking Capacity 25 KA at 415 V-Current Rating -125 Amps & 70% -100% adjustable |
| 236 | Current Rating -25 to100 Amps & 70% -100% adjustable |
| 237 | MCCB with Breaking Capacity 35 KA at 415 VCurrentRating-160Amps&Adjustable:70%-100%thermal&5-10times magnetic setting |
| 238 | CurrentRating-200Amps&Adjustable:70%-100%thermal&5-10times magnetic setting |
| 239 | CurrentRating-400Amps&Adjustable:70%-100%thermal&4-10times magnetic setting |
| 240 | CurrentRating-800Amps&Adjustable:70%-100%thermal&4-10times magnetic setting |
| 241 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Busbar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032( exclusive of MCB &isolator)- |
| 242 | FIXING OF SFUs, DBs,BUSBAR,MCCBs,MCBs, ISOLATORs & RCBOsFixing of metal clad enclosure on 25 X 5 mm flat iron clamps including supplying and fixing of clamps as required duly embedded in masonary including cable connection and other required materialas per specification :-32 Amps DP switch /SPN DB up to 8 way /16 AmpTPN DB up to 3 way per pole or 16 Amps TP or TPN switch / 16 Amps 415 V Isolator |
| 243 | Fixing of MCB /MCCB/ Isolator SP/DP in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cableconnection etc. complete (Labour only ) |
| 244 | Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamps duly embedded in wall,cable connection etc. complete.FOR S.No :-8.5 (1) to 8.5 (4) |
| 245 | Supplying, fixing,testing & commissioning wall / floor mounted LT Panel primer coated with two coat of enamel paint & provided with required gasket for dust/ vermin proof with degree of protection IP42 suitable for 415V 3 phase ,50 Hz ,4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) with frame work of angle iron/ channel/ bolted type construction duly compartmentalised for incomer,bus section , outgoings,cable alleys & CT,PT Ampere Meter ,Volt Meter , selector switches,Frequency Meter ,phase indicating lamps , energy Meter complete including cost of busbar supports,detachable cable gland plates,2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs,panel mounted Changeover switch/SFUs, etc. as required but excluding cost of busbar strips,Ampere Meter, Volt Meter, Selector switch as per approved design & specification |
| 246 | Supplying and fixing of LT Panel accessaries of approved make in existing LT Panel including connections etc.as required as per spececification Digital Ampere Meter with CTs with selector switch |
| 247 | Digital Volt Meter with selector switch & HRC fuse |
| 248 | Frequency Meter |
| 249 | Aluminium bus bar strips with PVC sleeves |
| 250 | LED lamps |
| 251 | Astro Time Switch-For lights On – Off based on Sunrise & Sunset timing Supply,installation,testing and commissioningofAstro-TimeSwitch based onAstro programi.e.calculation of sunrise and sunset times through date,time and Indian PINCodes.It shall have an option of Astro ON period over ride by time switch and Off set function which allows programming of switchingtimesOff set from the astronomictime.The230VAC operatedAstroTime Witch shall have an operating rangeof96...253VACwith1NO, 16A,AgSn02 Contact material with Starting current of 120A and 1COcadmium Free contacts,it shall haveLCD statusindicationwithbacklight display along with internal easily replaceable battery on the front side for set-upand programming.TheelectricallifeatratedloadAC1shallbe1Lakh cycles and shall work at an ambient temperature of-20to+50degC.Itshall havea dielectric strength between supply and opencontactsof4000V AC,between open contacts 1000VAC respectivelyand rated impulsevoltage(between supply and contacts )of 6kV an drated impulse voltage (between open contacts)of1.5kV.The mounting shall be on 35mmDINrail(EN 60715) and shall have necessary approvals like CE, IMQ and EAC |
| 252 | Suppling and fixing of approved make step type Modular electronic, Fan regulator single/double module including connection etc. as required on existing board -450 Watt |
| 253 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete as required confirming to IS :374/1979 with upto date ammendments.Ceiling Fan (Energy Saver 50 W)-1200 mm Sweep |
| 254 | Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished and as required.300mm sweep 900 RPM |
| 255 | Fixing of Flourescent Tube fitting on wall /ceiling on wooden round block with anchor fastener /J hook & necessary material including connection with 3 core flexible wire etc. complete as required. |
| 256 | Earthing with G.I. Earth pipe 4.5 meter long and 40 mm dia with masonary enclosure in cement mortor, cover plate having locking arrangment on the top etc.(but without charcoal or coke and salt)complete as required. |
| 257 | Add Extra for using salt and charcoal / coke for pipe earth electrodeas required including excavation & refilling.Excavation 2.5 cum by manual labour |
| 258 | Excavation by making hole with Auger |
| 259 | Earthing with G.I. Earth plate 600mm X 600mm X 6mm thick including accessories and providing masonary encloser in cement mortor, cover plate having locking arrangment on the top and G.I. watering pipe 20mm dia 2.7 meter long etc. (but without charcoal or coke and salt ) complete as required. |
| 260 | Add Extra for using salt and charcoal / coke for G.I. Plate or Copper plate earth electrode as required including excavation &refilling. |
| 261 | Supplying and laying 8 SWG copper wire at 0.5 meter below ground level as conductor earth electrode including soldering etc. as required. |
| 262 | Supplying and laying 25mm X 6mm G.I. strip at 0.5 meter below ground level as strip earth electrode including soldering etc. asrequired. |
| 263 | Decorative designer polesSupply of XLPE Insulated power cable (conforming IS-7098) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 coreISI MARKED with Alu. Stranded /solid conductorSupply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductorARMOURED 4 CORE-10 sq. mm. |
| 264 | ARMOURED 3½ CORE-25 Sq.mm(XLPE) |
| 265 | 95 Sq.mm.(XLPE) |
| 266 | 120 Sq.mm.(XLPE) |
| 267 | 300 Sq.mm.(XLPE) |
| 268 | BRASS COMPRESSION GLANDSupplying and fixing heavy duty cable gland for P.V.C. insulated armoured cable with brass washer, Rubber ring complete erected with cable and lead connection etc. as per specification complete.Gland Size 22mm suitable for cable 2,3, 3½, 4 x 10 Sq.mmor 2x 16 Sq.mm |
| 269 | Gland size 32mm suitable for cable 2,3, 3½, 4 x 25 Sq.mmOR 2,3, 3½ x 35 Sq.mm OR 2,3 x 50 Sq.mm. |
| 270 | Gland Size 45 mm suitable for cable 3/3½x120 Sq.mm OR3½ x 95 Sq.mm OR 3 x 150 Sq.mm. |
| 271 | Gland Size 70 mm suitable for cable 3x240 Sq.mm OR3½ x 300 Sq.mm |
| 272 | LUGS:- Supplying and fixing cramping type Alum. lugs as per I.S.S. Specification suitable for following size of cable with Alu./Copper solid/stranded conductor evently cramped with high/pressure tool and connected to switch gear/Bus/M.C.C.B./ M.C.B. etc. as required complete.ForConductor Size- 6mm to 16 Sq.mm |
| 273 | 25 Sq.mm |
| 274 | 95 Sq.mm. |
| 275 | 120 Sq.mm |
| 276 | 300 Sq.mm. |
| 277 | CABLE LAYING Laying of one number PVC insulated and PVC sheathedpower cable of 1.1kVgrade of size exceeding 25 Sq.mm butnot exceeding 400 Sq.mm in the existing masonary openduct as required |
| 278 | Layingof onenumber PVC insulatedandPVCsheathed power cable of 1.1 kV grade of size not exceeding 25 Sq.mm in th existing masonary open duct as required. |
| 279 | Supply and fixing of LED tube rod comprising of LED tube with non integral / integral driver, 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with efficacy > 80 lm/W. LED driver PF 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70.Submission LM 80-08 Form LED Source Manufacturer & LM79-08 / IS16106 from NABL approved lab. Manufacturer mandatory i/c connection wire, testing etc.to complete the job. 2 Yrs Guarantee certificate from manufacturer.1 X 18/20/22W, Integral |
| 280 | Supplying and fixing surface mounting LED down lighter, LEDof 1 to 3 W each assembled on single MCPCB, having colortemp 6500K & having 50000 burning hrs life with minimum@ L 70, system lumen output should be minimum withefficacy>80lm/W. LED driver PF 0.95 & THD < 20%. Thecolour rendering index of LED light should be more than 70.Housing made of CRCA powder coated frame with glare freediffused polycarbonate cover. Submission LM 80-08 FormLED Source Manufacturer & LM79-08 / IS16106 from NABLapproved lab. Manufacturer mandatory. i/c connection wire,testing etc. to complete the job. 2 Yrs Guarantee certificate from manufacturer.7 W/8 W, 100/150mm |
| 281 | Providing and erecting 9 mtrs. High hot dipped galvanized octagonal poles with bottom of 200mm A/F, top 100mm, A/F made from 3mm thick HT plate & 290x290x16mm base plate with 1500mm long decorative sword type double arm bracket complete ererted in an approved manner on provided foundation. Suitable size & type of foundation bolts. 4 nos. bolts typeM20x750mm 'J' type foundation bolts (EN8 grade) |
| 282 | Designing & casting with M-20 cement concrete foundation suitable for 9 mtrs. Octagonal poles considering the safe soil bearing capacity at site as 10 T/sqm at 2 mtrs. Depth including excavation, foundation nut bolts in an approved manner. |
| 283 | Providing and fixing of sword canopy type single arm GI bracket upto2 Mtr. Long for 70mm A/F top octagonal pole |
| 284 | Supplying of street light with high power LED of 1 to 3W each assembled on single MCPCB,system lumens output with efficacy>110lm/W.luminiarehaving color temp 6500K&50000 burning hrs life with minimum@L70, The colour renderingindex of LED light should be more than70.Luminiarecomprisesofdriver,PF0.95&surge protection 4KV.Housing made of pressure die castaluminiumwithheatresistantflatglass/Lenstype,IP66protection.SubmissionLM80-08FormLEDSourceManufacturer&LM79- 08/IS16106 from NABL approved lab.Manufacturermanadatoryi/c50mm.diaG.I. Pipebracketupto2mtr.longinrequiredangle/shape, connection ead,testingetctocompletethejob.2YrsGuaranteecertificatefrom manufacturer.-150W |
| 285 | SupplyinganddrawingsinglecorePVCinsulatedcableFRwith coppermultistrandconductorISImarkedinexistingrigidconduitin surface or concealed as per specification.2.5 Sq mm cable-3 X 2.5 sq mm |
| 286 | Supplying and installing double wall corrugated pipes (DWC) of HDPE (IS 14930 Part II -marked) for cable laid underground with necessary material and at required depth upto 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good.-50.00mm outside dia. |
| 287 | 110.00mm outside dia |
| 288 | 200.00mm outside dia. |
| 289 | Supplying, installing, testing and commissioning of 11/0.4 KV 3 Phase 50 cycle oil immersed, naturally cooled, outdoor type transformer connected delta on H.T. side and star on L.T. side, dehydrating silica gel breather on eye level, rating and diagram plate, two earthing terminal, lifting lugs, oil level gauge, drain valve with plug, temperature not exceeding 50ºC on load, oil filling hole with plug, four unidirectional roller, arcing horns, explosion vent, terminal arrangement bushing on H.V. side and cable box on LV side, first filling of oil upto desired level and transformer installing on existing structure with all required materials arrangement as required ISI marked & as per IS specification, hand operated off load tap changer switch above 100 KVA, oil conservator with drain valve, plug 63 KVA and above.Copper wound-315 KVA |
| 290 | 500 KVA |
| 291 | HT/LT line work as per MPEB Estimate |
| 292 | Lift/Elevators: Supply, installation, testing, commissioning, and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD specification including automatic rescue device (ARD), All standard equipments, accessories and control equipments as per manufacturer's design and as per CPWD specification (Part III LIFTS) on turnkey basis, Conforming to NBC/statutory norms and fulfilling following requirements. (i) Type: Passenger lift.(ii) Load: As specified elsewhere from 4 passengers (272Kg) to 26 passengers (1768Kg) (for each person standard weight 68Kg.).(iii) Speed: 1.00 metre/sec. or less as required.(iv) Control: ACV3F, 32bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (building monitoring system) supporting software.(v) Motor/machine: Permanent magnetic synchronous gearless motor.(vi) Operation: Simplex collective selective with/without lift attendant.(vii) Total rise: About 3 mtrs. (approx) two stops only.(viii) Landings: All floors on same side.(ix) Floors served: G+1.(x) Signals: Digital car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car.(xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.(xii) Guide rail: As per manufacturer's specification.(xiii) Lift & car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS).(xiv) Car entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).(xv) Landing entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS).(xvi) Car door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel.(xvii) Landing door: S.S. (stainless steel) hairline finish centre/telescopic opening door with vision panel.(xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams.(xix) Car interior: S.S. (stainless steel) panel with hair line finish on all sides.(xx) Car floor: Anti skid PVC flooring on heavy duty M S (mild steel) platform.(xxi) Car ceiling & lighting: S. S. (stainless steel) finish with aesthetic appearance with LED ceiling lights(xxii) Carventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided).(xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car.(xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room.(xxv) Emergencyalarm: Battery operated alarm bell system in lift car & control room / ground floor. (xxvi) Position of machine room: Directly above the hoist-way.(xxvii) Electric power supply: AC 415 V, 3 phases 50 Hz & AC 230 V 1phase 50Hz terminated in machine room. (xxviii) Fire man switch : Fire man switch at machine room/terminal landing (xxix) All car panel buttons and all floor switches must be with Braille language as per lift act. (xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed.(xxxi) Spring buffer/hydraulic buffer shall be provided(xxxi) Spring buffer/hydraulic buffer shall be provided(xxxii) Mechanical over speed governor, door key holes in the floor doors shall be provided.(xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.(xxxiv) In the hoist way fascia plate shall be provided.(xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level. (xxxvi) Car top safety barricade shall be provided.(xxxvii) ARD (automatic rescue device): Solid state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure.8 Passenger (544Kg.) |
| 293 | Providing laying, testing and commissioning of 'C' class heavy duty MS pipe confirming to IS 1239/3589 i/c fittings like elbows, tees, flanges, reducer, jointing with nuts bolts, gaskets and welding etc. and fixing the pipe on wall/ceiling with suitable hangers, clamps, supports, as required and painting with two or more coats of synthetic. Enamel paint of required shade complete as directed by Engineering-in-Charge.25 mm dia |
| 294 | 80 mm dia |
| 295 | 150 mm dia |
| 296 | Providing and fixing single headed hydrant valve with instantaneous female Gun metal couplings of required dia with cast iron wheel ISI marked conforming to IS 5290 (Type - A) with blank gunmetal cap and chain, adopter as required complete as directed by Engineer-in-Charge.63mm dia |
| 297 | Providing and fixing orifice plate made of 6mm thick stainless steel with orifice of required size in between flanged and landing valve of external and internal hydrant to reduce pressure to working pressure of 3.5 kg/cm complete as per specification required. |
| 298 | Supplying and fixing dia,15m long, RRL hose pipe with following diamale and female gun metal couplings duly binded with GI wire, rivets etc. confirming to IS 636 (type-A)as required.-63mm dia |
| 299 | Providing and fixing first -Aid hose reel with MS construction spray painted in post office red, confirming to IS 884 with up to date amendments, completewith the following as required.) (a) 30-36m long 20mm (nominal internal) dia water hose thermoplastic (textile reinforced ) type -2 as per IS 12585 (b) 20mm (nominal internal) dia gun metal globe valve and nozzle. (c) Drum and brakets for fixing the equipments on wall.(d) Connections from riser with 40 mm dia stop valve (gun metal) and M.S. pipe |
| 300 | Providing and fixing 2 way fire brigade connection (FBC) of CI body with2 nos. gun metal male instantaneous inlet couplings complete with cap and chain as required. For 150mm dia MS pipe connection, confirming to IS 904 as required. |
| 301 | Providing and fixing air vessel made of 250mm dia, 8mm thick MS sheet, 1200mm in height with air release valve on top and flanged connection toriser, drain arrangement with 25 mm dia Gunmetal wheel valve, with required accessories, pressure guage and painting with synthetic enamelpaint of approved shade as required . |
| 302 | Providing and fixing 63mm gun metal branch pipe with 20mm (nominal internal diameter)size gun metal nozzle conforming to IS 903, suitablefor instantaneous connection, to interconnect hose pipe coupling as required. |
| 303 | Providing and fixing hose cabinet of size 700x600x300mm made of 16 gauge thick MS sheet with 4 mm thick float glass doors in front painted \\"FIRE\\" in red paint i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15m Long hose pipe, 1 no branch pipe mounted on wall or raised brick platform& duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant, as directed by Engineer-in-Charge. |
| 304 | Providing and fixing standard fireman's axe with heavy insulated rubber handle conforming to IS: 926 complete. |
| 305 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure,horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.900 lpm at 35 m Head |
| 306 | Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-1) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 307 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 308 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 309 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 310 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 311 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 312 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-2) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 313 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 314 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 315 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 316 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 317 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 318 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-3) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 319 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 320 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 321 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 322 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 323 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 324 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-4) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 325 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 326 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 327 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 328 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 329 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 330 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-5) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 331 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 332 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 333 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 334 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 335 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 336 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Supplying,Installation,Testing and Commissioning of Cubical Type Outdoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:55) (Terrace Panel-6) .The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved. |
| 337 | INCOMER-MCCB 63 A F.P 25 Ka with Adj. Thermal & Adj. magnetic release with Extendable ROH Icu=Ics=100% |
| 338 | Digital Metering Devices,comprising Voltmeter,Ammeter,Selector Switch,Indicating Lamps,C.T Set,Bus Bar(80 Amps ) and MCB Strip of suitable size as Required. |
| 339 | OUTGOINGS-MPCB 19-25 A With STD. Magnetic Release |
| 340 | Power Contactor 40 A415 Volts, AC-3 Duty |
| 341 | Start/Stop Push ButtonSize of wiring for CTS:- 2.5 sqmmSize of wiring for voltage sensing Metering :-4.0 Sq.mmSize of wiring of all push buttons, indicating lamps:-1.5 Sq.mmTypes of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSHHinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire . |
| 342 | The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc.Gland Plates to be 3.0 mm Thick.Providing, fixing, testing and commissioning of butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, confirming to IS 13095, of following sizes as required.-150mm dia |
| 343 | Providing, installation, testing and commissioning of dual plate non- return valve of following sizes confirming to IS 5312 complete with rubber gasket,GI bolts, nuts, washers etc. as required.-150mm dia |
| 344 | Providing, installation, testing and commissioning stainless steel strainerfabricated out of 1.6 mm thick stainless steel sheet with 3 mm dia holes with stainless steel flange.-150mm dia |
| 345 | Providing and fixing Pressure switch in the MS pipe Line including connection etc. as required. Capacity 4.5 kg. |
| 346 | Providing and fixing pressure transducer (dial type pressure gauge (dial diametre 100mm pressure range 0-10 kg/cm) suitable for 12 volts/24DC. Including connection etc. as required. |
| 347 | Providing and fixing of carbon-dioxide type fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.-Capacity 3.0 kg |
| 348 | Providing and fixing of ABC Power type fire extinguishers consisting ofwelded M.S. cylindrical body, squeeze lever discharge valve fitted withpressure indicating gauge internal discharge tube 30 cm long high pressure discharge hose, discharge nozzle, suspension bracket. Conforming to IS: 15683 finished externally with red enamel paint fixed to wall with brackets complete with internal charge.-Capacity 6.0 kg Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail