| 1 | Rewiring for light point / fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit i/c dismantling etc as reqd.(a) Group A |
| 2 | Supplying and drawing following sizes FRLS/HFFR PVC insulated copper conductor, single core cable in existing surface/recessed steel/ PVC conduit as reqd.(a) 3x1.5 sq. mm |
| 3 | (c) 3x4 sq.mm |
| 4 | 2X6 sq.mm + 1X6 sq.mm |
| 5 | Supplying & fixing suitable size of phenolic laminated sheet cover in front etc. as reqd. i/c cutting for switches / socket, fixing of piano type switch, connection testing etc. as reqd.a) 200 mmX125mmX3mm |
| 6 | 225mm X 275mm X 3mm |
| 7 | 125mmX125mmX3mm |
| 8 | 75 mmX75 mmX3 mm |
| 9 | Supply & fixing following piano type switch / socket on the existing switch box/cover i/c connection etc.as reqd.(a) 5/6 Amp. Switch |
| 10 | 15/16 Amp. Switch |
| 11 | (b) 3 pin 5/6 Amp. socket outlet |
| 12 | (c) 6 pin 15/16 Amp socket outlet |
| 13 | (d) Telephone socket outlet |
| 14 | (e) TV antenna socket outlet |
| 15 | (f) Bell Push |
| 16 | (g)40 mm iron staples/saddle/screw |
| 17 | (h)50 mm iron staples/saddle/screw |
| 18 | (i)Fan round sheet |
| 19 | Supplying and fixing 3 pin, 5 Amp ceiling rose on the existing junction box/ wooden block i/c connection etc as reqd. |
| 20 | Supplying & fixing call bell / buzzer suitable for single phase , 230 volts, complete as reqd. |
| 21 | Supplying & fixing brass batten/ angle holder including connection etc. as reqd. |
| 22 | Supplying & fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus bar, earth bar, din bar, interconnections, power painted i/c earthing etc. as reqd. (But without MCB/RCCB/Isolator)(a) 8 way, Double Door |
| 23 | Supplying & fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd.(a) Single Pole |
| 24 | (b) Double Pole |
| 25 | supplying and fixing the DP sheet steel enclosure on surface/recess along with 25/32A 240 V \\"C\\" curve DPMCB complete with connection,testing and commissioning as reqd. |
| 26 | Supplying and fixing following rating ,double pole (single phase and neutral current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCBDB complete with connections testing and commissioning as required .a) 25 A Please Enable Macros to View BoQ information |