| Sl. No. | Item Description |
| 1 | M&L for cement screed bed or bedding layer on floor 20 mm thick in CM 1:6 complete incl Roughning of surface complete all as specified and directed. |
| 2 | M&L for Coloured Cement concrete chequered tiles 20cm X 20cm X 25mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with grey cement and pigment complete all as specified and directed. |
| 3 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m in depth for foundation/drain/sewage line in soft/loose soil complete all as specified and as directed. |
| 4 | Excavation over areas not exceeding 1.5m deep and getting out in soft/ loose soil complete all as specified and directed. |
| 5 | Excavating over areas exceeding 1.5m but n. exc 3.00m in depth and gating out in soft/ loose soil complete all as specified and directed. |
| 6 | Excavating over areas exceeding 3.00m but n. exc 4.50m in depth and gating out in soft/ loose soil complete all as specified and directed. |
| 7 | Excavating over areas exceeding 4.50m but n. exc 6.00m in depth and gating out in soft/ loose soil complete all as specified and as directed. |
| 8 | Material and labour for brickwork with old size sub class `B' bricks straight orcurved on plan not exceeding 6m mean radius as in walls in cement mortar 1:6 complete all as specified and as directed. |
| 9 | Material and labour for brickwork with sub class `B' bricks in one brick thick honey comb walling, built in cement mortar 1:3 complete all as specified and as directed. |
| 10 | M&L for loose filling with broken bricks aggregate of gauge 40 to 80mm in soakage pits, soakage wells complete all as specified and as directed. |
| 11 | M&L for RCC (Nominal Mix) type B1 1:1 1/2:3 (20 mm graded aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 12 | M & L for formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similar work not exceeding 200mm thk horizontal or sloping, flat and rough finished surface of concrete complete all as specified and as directed. |
| 13 | High strength steel deformed TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm dia. complete all as specified and as directed. |
| 14 | High strength steel deformed TMT bars 5mm dia and over, upto and including 10mm dia as in stirrups cut to length, bent to shape required including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and as directed. |
| 15 | Returning, filling in, includingspreading,leveling, watering and wellramming in layers notexceeding 25 cm insoft/ loose soil complete all as specified and as directed. |
| 16 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 17 | S&F PVC vent cowl 75mm dia complete all as specified and as directed. |
| 18 | M&L for 150 mm nominal size Double wall corrugated HDPE pipes stiffness class SN 8 high density, polyethylene pipe resistent to chemicals, easy and light weighted, long living, low friction, flexible, sun resistant pipe and laid in trenches including taking down of any type of old pipe complete all as specified and as directed. |
| 19 | M&L for cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) in bed of drain pipe 150 mm bore pipe including forming cradles at joints complete all as specified and as directed. Note : Thickness of bed below the barrel of pipes 100 mm for pipes 150mm dia and width D+300mm. |
| 20 | S&F factory made RCC GT Cover of Size 400mm x 500mmx 50mm thick or as per site requirement with 01 No handle and 150mm dia notch at one side of cover at center at 500mm long side complete all as specified and as directed. |
| 21 | Cutting into existing manholes for connecting new drains 150mm dia,making good to pipe & rendering,cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and directed. |
| 22 | Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed by Engr-in-Charge. |
| 23 | M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 24 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 25 | All as per Serl Item No 8 here in before but half brick thick wall built in cement mortar 1:4 complete all as specified and directed. |
| 26 | Use & waste of formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits if any of foundations and plinth beams and similar work,vertical or batter for flat rough finished surface of concrete complete all as specified and directed by Engr-in-Charge. |
| 27 | Use & waste of formwork to sides of pillars,posts,struts,piers,columns and stanchions etc rough finished for square/rectangular or polygonal surfaces of concrete complete all as specified and directed by Engr-in-Charge. |
| 28 | Use & waste of formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished flat surfaces of concrete all as specified and directed |
| 29 | M&L for RCC (nominal mix) in (1:2:4) type B1 20mm graded stone aggregate as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed by Engr-in-Charge. |
| 30 | M&L for RCC (nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in columns, pillars,piers,posts and struts etc complete all as specified and directed. |
| 31 | M&L for RCC(nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in beams, cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for RCC(nominal mix) (1:2:4) type B1 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-in-Charge. |
| 33 | M&L for 15mm thick cement plaster in cement mortar 1:4 on brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 34 | M&L for 10mm thick cement plaster in cement mortar 1:6 on brickwork or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 35 | M&L 5 mm thick cement plaster in cement mortar 1:3 on ceiling surfaces finished even and smooth without using extra cement all as specified and directed by Engr-in-Charge. |
| 36 | M&L for hard core of broken stone or boulders gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and ramed to a true surface complete all as specified and directed by Engr-in-Charge. |
| 37 | M&L for 100 mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in sub base for floors etc complete all as specified and directed by Engr-in-Charge. |
| 38 | M&L for 50mm thick PCC(1:2:4) type B-1 (using 20mm graded stone aggregate) as in flooring complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for 75 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in sub base flooring complete all as specified and as directed. |
| 40 | M&L for Coloured Machine pressed cement concrete chequered tiles 30cm X 30cm X 20 mm thick machine pressed; set jointed and pointed in neat cement slurry in floors and cut and pointed with white cement and pigment over and including 15mm thick screed bedding layer in CM 1:6 including demolition of old chequered tiles all as specified and as directed. |
| 41 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand including dismantling of old paver block or stone slab laid dry complete all as specified and as directed. |
| 42 | M&L for cement concrete Type B-1, 1:2:4 (using 20mm graded crushed stone agg) in copings, kneelers, apex stones, bed plates, kerbs and the like incl weathering, slightly rounded or chamfered angles and throating, complete all as specified & directed . |
| 43 | M&L Coloured Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with pigment with colour of tiles over and including screed bedding 15mm thick in cm(1:4) complete all as specified and directed. |
| 44 | M&L for glazed coloured designer ceramic tiles of size 350x250x7mm/ 400x350x6mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over and including 10mm thick rendering in cement mortar (1:3) and pointed in white cement with pigment to match the colour of tiles complete all as specified and directed by Engr-in-Charge. |
| 45 | S&F Solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing as per specification complete all as specified and directed. |
| 46 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail either side & as gap insert for top rail and bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 47 | S&F 100mm butt hinges medium weight cold rolled fixed to doors with SS screws complete all as specified and directed. |
| 48 | S&F 150mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed. |
| 49 | S&F 125mm long aluminium handles cast type anodised ISI Marked complete all as specified and directed. |
| 50 | S&F powder coated aluminium sliding windows three track section (Size 92mmx 31.75mm x 2.00 mm) weightnot less than 1.864 Kg/m and shutter size 14.7mm x43mm with aluminium anodised frame (Chowkhat) of aluminium section 104.00mmx44.45mmx1.80mm thick and two shutter having 14.8 mm thick tinteg glass.and one shutter stainless steel wire of dia 0.36 mm and average with of aperture1.40 mm complete all as specified and directed. |
| 51 | S&F anodised aluminium ventilator with aluminium anodised frame of aluminium section 62.50 mm x 37 mm x 1.5mm thick and with top hung shutter having style and rails of aluminium section 47.62 mm x 44.45 mm x 1.5 mm thick and shutter wire gauzed and bottom half portion of shutter fixed type and glazed glass pane without sash bars including necessary joining cleats,glazing clips,rubber packing, anodized, aluminium snap beading, screws, anodised aluminium fitting such as peg stays 150mm long, handles and 100mm long SS hinges etc complete all as specified and directed. |
| 52 | S&F Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, complete all as specified. |
| 53 | S&F in repairs Vitreous China squatting pan, ‘Orissa’ pattern' size 580 x 440 mm white with integral foot rests (excluding flushing cistern), including flush pipe of polyethylene of low or high density, connection to trap, and to flushing pipe, anti-syphonage pipe, etc. complete trap set in concrete and including CI 'P' Trap & 100mm cast iron sanitary connection socket to fit WC out-let complete all as specified and directed. |
| 54 | S&F 10 ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphonic handle lever PVC bend including connecting to WC and fixing on walls with bracket all as specified. |
| 55 | S&F 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed by Engr-in-Charge. |
| 56 | S& F Bib tap of cast copper alloy brass but fancy type, Chromium plated 15mm bore, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified. |
| 57 | S&F 1000 litres capacity rotational moulded, triple layer polyethylene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roof including fittings tank nipple etc. complete all as specified and directed by Engineer in Charge. |
| 58 | S&F 500 litres capacity rotational moulded, triple layer polyethylene water storage tanks (cylindrical vertical with closed top) hoisting and fixed in position on roof including fittings tank nipple etc. complete all as specified and directed by Engineer in Charge. |
| 59 | S&F Gun-metal, globe or gate valves 20mm dia bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 60 | S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 210 gms) and fixed complete all as specified and directed by Engr-in-Charge. |
| 61 | S&F 600x450 mm beveled edge looking mirror of selected quality glass and backing with 6mm thick AC building board and fixed to wall with PVC rawl plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engr-in-Charge. |
| 62 | S&F Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as direcetd. |
| 63 | S&F Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed |
| 64 | S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flangescomplete all as specified and directed. |
| 65 | S&F 15mm bore stop/angle valve cast copper alloy with crutch or butterflty handle, screwed down screwed high pressure for iron pipe or for brass ferrule fancy type chromium plated with fancy shank and cup complete all as specified and directed by Engr-in-Charge. |
| 66 | S&F PVC Connection pipe, 450mm long, heavy duty with two sets of brass nuts & washers (one at each end) etc suitable for 15mm bore of pipe as in repair complete all as specified. |
| 67 | S&F Health Faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed by Engr-in-Charge. |
| 68 | S&F Wash hand basin, flat back 550x400mm vitreous china (white) including PTMT waste fittings, 32mm bore size, waste pipe, PVC, 32mm bore, angle iron/cast iron brackets of required size as directed & making good disturbed surfaces to match with the existing complete all as specified and directed by Engr-in-Charge. |
| 69 | S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including waste coupling and waste pipe 32mm dia bore complete all as specified and directed by Engr-in-Charge. |
| 70 | S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed by Engr-in-Charge. |
| 71 | S&F 110mm bore PVC (SWR) pipe of pressure not less than 4kg/sqcm in single socketed, in any length with rubber ring joints,fixed to wall including distance pieces and stack clamp with nuts and bolts complete all as specified and as directed. |
| 72 | S&F 110mm bore PVC (SWR) pipe of pressure not less than 4 Kg/Sqcm in single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 73 | S&F 110mm bore, PVC (SWR) bends any radius complete all as specified. |
| 74 | S&F 110mm bore, PVC (SWR) branch piece, single (single T) equal or unequal with access door complete all as specified. |
| 75 | S&F 75mm bore PVC(SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and directed. |
| 76 | S&F 75mm bore PVC(SWR) bends any radius laid in trenches or in floor complete all as specified and directed. |
| 77 | S&F 110mm bore PVC (SWR) 'S' trap complete all as specified and as directed. |
| 78 | S&F galvanised steel water tubes 15 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 79 | S&F galvanised steel water tubes 20 mm bore medium grade, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed by Engr-in-Charge. |
| 80 | M&L for Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection, 75mm thick, surfaces finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge. |
| 81 | M&L for cement concrete 1:3:6 type C2 with using 40 mm graded stone aggregate as in concrete bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested completed all as specified and directed by Engr-in-Charge. |
| 82 | S&F factory made 75mm thick SFRC manhole/ Drain covers with frame (heavy duty) HD-20 graded designation, confirming to IS-12592, area not exc. 0.50 Sqm each, fixed in cement concrete 1:2:4 using 20mm graded stone aggregate complete all as specified and directed. |
| 83 | Cutting into existing manholes for connecting new drains 150mm dia,making good to pipe & rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished & reforming benching as required complete all as specified and directed by Engr-in-Charge. |
| 84 | M&L for Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over and including a coat of chalk whiting primer complete all as specified and directed. |
| 85 | M&L for Preparation of new plastered surfaces and applying two coats of cement base paint over and including a coat of chalk whiting primer complete all as specified and directed. |
| 86 | M&L for Preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified and directed. |
| 87 | M&L for applying two coat of Bitumen primer blown any grade, applied hot, to concrete surfaces at the rate of 1.5kg. per sq. m per coat APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 88 | Taking up or down 15mm bore dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge. |
| 89 | Taking up or down 20mm bore dia steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engr-in-Charge. |
| 90 | Taking down door/window/ventilator frames with shutters not exc 1.50 sqm each (without taking off shutters from frame) complete all as specified and directed. |
| 91 | Taking down door/window/ventilator frames with shutters exc 1.50 sqm but not exc 4.00 sqm each.(without taking off shutters from frame) complete all as specified and directed. |
| 92 | Taking down shutter of any description n exc 1sqm each complete all as specified and directed. |
| 93 | M&L for 18 mm thick 100% Solid WPC (Wood Polymer Composite) Laminated Board of required size comprising of virgin PVC resin of K Valve 57-60 (Suspension Grade),Calcium Carbonate and natural fibers ( Wood powders/rice husk/Wheat husk) and non toxic additives, made from Extrusion process WPC foam sheet Single Extruded (Inner) with having minimum density not less than 650 kg/cbm having good screw holding capacity (Screw Withdrawal strength of 2000 N (Face) & 1100 N (Edge), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850 N/mm2 and resistance of spread of flame of Class A category with property of being Termite/Borer Free, Water/Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter complete all as per specified and directed. |
| 94 | S&F of stainless steel handles 100 mm size for cupboard/kitchen cabinet shutters complete all as per specified and directed. |
| 95 | M&L Mild steel frame work as in door chowkhats with angle iron welded toghether ends of angle shouldered and fixed to opening, confirming to Fe-410-W (Gde-E-250) quality 'B' complete all as specified and directed. |
| 96 | S&F Aluminium door single leaf with powder coated aluminium frame of section 62.5x37x1.5mm thick, shutter with bottom & middle rail of section 112.50x 37x1.5mm thick and styles & top rail of section 83x37x1.5mm thick with centrally locking arrangement with lock make of ‘GODREJ’ or ‘LINK’ 7 lever and self closing device with rebate including jointing cleats, fixing of builders hardware fittings, necessary numbers of floor spring and glazing with 5mm thick frosted glass/mesh including necessary fittings, fixtures & aluminium snap beads, complete all as specified and directed. |
| 97 | M&L for vitrified ceramic tiles light shade 7 to 8mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor finishes complete all as specified and directed by Engr-in-Charge. |
| 98 | M&L for 10mm thick rendering of ready mix plaster of approved make on brick work or concrete surfaces on wall, finish the surface even and smooth without using extra cement as whole or in patch etc and applying two coats of Oil Bound Distemper over a coat of primer and including 1mm thick wall care putty etc all as directed, rubbish of the premises complete all as specified and directed. |
| 99 | M&L for 5mm thick rendering of ready mix plaster of approved make on soffit of Rcc slab/ceiling/beams, finish the surface even and smooth without using extra cement as whole or in patch etc including taking down cement plaster on brick walls etc and applying three coat of white wash all as directed, rubbish of the premises complete all as specified and directed. |
| 100 | M&L for preparation of new Plastered or unplastered surfaces of ceiling and applying two coat of white wash over wall care putty(where ever required) on ceiling surfaces complete all as specified and as directed. |
| 101 | M&L for preparation of old Plastered or unplastered surfaces of ceiling and applying two coat of white wash over wall care putty(where ever required) on ceiling surfaces complete all as specified and as directed. |
| 102 | M&L for applying wall care putty 1mm thick on ceiling even and fair surface complete all as specified and directed. |
| 103 | M & L for complete removal of existing treatment from walls applying a coat of priming plastered and other surfaces with alkali resistant primimg paint over and including wall care putty 1 mm thick and applying two coats of Oil Bound distemper with rich matt finish with roller including cleaning of OBD stains on floor/window/joinery's complete all as specified and directed. |
| 104 | Demolition of Brick /stone walling built in cement mortor including all quoins ,coping etc and removal of rubbish beyond MOD land complete all as specified and directed.. |
| 105 | Demolition of cement concrete (unreinforced) in ground floor and paving not exc. 15cm thickness (below or above ground level), removal of rubbish beyond MOD land complete all as specified and directed. |
| 106 | S&F in repair stainless steel kitchen plate rack made out of stainless steel sheets 1mm thick overall size 600mm x 750mm x 250mm complete all as specificed and directed. |
| 107 | S&F in repairs stainless steel sink of thickness of sheet not less than 0.8mm for kitchen or loboaratory with plug, washer and wastes, including bedding in cement morter to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size of bowl size 495mmX420mm bowl size 410mmX330mmX160mm including suitable Cp waste coupling and waste pipe 1.2m long complete all as specified and directed. |
| 108 | S&F in repair 15mm bore dia stop valves cast copper alloys, screwed down high pressure but fancy type chromium plated (Concealed type) with long shank and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 109 | S&F in repair 15mm bore bib taps chromium plated fancy type cast copper, screwed down, screwed for iron pipe or for brass ferrule & fixed for GI pipe including complete all as specified and directed. |
| 110 | S&F in repair Pillar taps fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed |
| 111 | S&F in repairs 75mm bore cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 112 | S&F 75mm bore PVC (SWR) pipes single socketed, in any length including mild steel stack clamps (as per sample) fixed in cement concrete 1:2:4 blocks with rubber ring joints fixed to walls and including taking down eaves gutters and rainwater pipes (any size or pattern), with all fittings viz. heads, shoes, bends, swan-necks etc, removal rubbish beyond MOD land complete all as specified and directed. |
| 113 | S&F 75mm bore PVC (SWR) bends with rubber ring joints fixed to walls complete all as specified and directed. |
| 114 | S&F 75mm bore cast iron sand cast soil waste and vent pipe in any length with or without ears with cement joints fixed to walls/ceiling or laid in vertical surfaces and including dismantling of cast iron drain pipes including fittings, jointed in cement mortor complete all as specified and directed. |
| 115 | S&F 75 mm CI bends (any radius) diminishing pieces or taper (large base measured) complete all as specified and directed. |
| 116 | M&L for PCC 1:2:4 type B-1 (20 mm graded stone aggre) as in bed blocks for gola, hold fast, roof padding/flooring, coping bedding rounded or chamfered and similar work etc., complete all as specified and directed. |
| 117 | Demolition of reinforced cement concrete as in Chajja, RCC parapet, Kitchen slab, Chullah hood, chimney portion and similar work concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 118 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid bedded and pointed in any mortar complete all as specified and directed by Engr-in-Charge. |
| 119 | M&L kota stone slab 18-20 mm thick as a one piece area not exc 1.00 sqm in tread and riser of steps, skirting, dado and pillers laid over and including 20mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shed of the slab including rubbing and polishing and including demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar and removal of rubbish beyond MOD land complete all as specified and directed. |
| 120 | M&L Granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms over & including 15mm thick screed in cement mortar (1:4) with pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified. |
| 121 | S&F curtain rods of stainless steel 25mm dia with and including SS decorative finials and SS brackets suitable for SS curtain rod fixed on wall etc complete all as specified & directed. Note : -(a) Only length of SS curtain rod shall be measured and paid.(b) SS decorative finisals and brackets shall be provided for each curtain rod and rate shall be incuded with SS curtain rod. |
| 122 | M&L for 75 mm thick PCC (1:4:8) type D2 (using 40mm stone aggregate) as in sub base of floor complete all as specified and directed. |
| 123 | M&L for 50mm thick sand cushion/Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 124 | M&L Providing, supplying and installation of 8 layer acrylic synthetic flooring for basketball/volleyball/throwball court (3 to 4 mm thick) over existing plain cement concrete with following stages given below:-PATCH:- 100% Acrylic based emulsion to repair cracks to concrete and asphalt pavement it should be carried out after 30 days from date of placement of concrete.PRIMER:- 100% Acrylic unic floor based emulsion to improve bond of acrylic court system to the concrete or asphalt surface. RESURFACER:- 02 layer of Acrylic Resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for Acrylic ITF approved system. And fills the surface chips, voids and conceals repairs while providing a smooth surface for colour coating.CUSHION COAT:- 02 layer of Acrylic floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system. ULTRA CUSHION COAT:- 02 layer of Acrylic floor cushion for asphalt or concrete surfaces in preparation for Acrylic ITF approved system.PRE COAT:- 02 layer of Acrylic based textured tennis top coat. Ideal for colour coating basketball/volleyball/throw ball courts and other sport pavement surfaces complete all as specified and directed.(Note:- Over 30 days old from the date of placement of concrete alongwith repairing of cracks of concrete and asphalt surfaces the Acrylic Synthetic Flooring work of Basketball/Volleyball/Throwball is carrier out) |
| 125 | M&L for preparation of two coats of synthetic enamel paint over a coat of primer on brick/concrete surface complete all as spd and directed |
| 126 | Supply & fixing air termination single pointed copper rod 12 mm dia and 300 mm long with necessary fixing arrangement on roof complete all as specified and directed. |
| 127 | S & F Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors with rubber & bitumen washer & fixed to porcelain insulator on wall for down conductor complete all as specified and directed |
| 128 | S & F test point terminal block made of phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to copper strip bracket fixed to porcelain insulator in wall as in repairs, complete all as specified and directed |
| 129 | S & F epoxy insulator of suitable size for support of Earth strip into wall/ corrugated sheet with two nut, bolt and washer of suitable dia complete all as specified and directed. |
| 130 | S & F GI tubing medium grade GI with all fitting and fixed to roof for protection of air termination of size 40mm dia bore. |
| 131 | M & L earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with Copper strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of char coal dust and common salt complete all as shown in electrical plate No 5 and connected to earthing test point all as specified and indicated including testing on completion including retrieving old existing earthing complete all as specified and directed. |
| 132 | M & L for Point wiring in open cashing caping complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, with fabricated modular metal flush box duly make embossed, concealed in walls and with suitable size of modular inner and outer cover plates as required for housing modular switches , socket outlet and fan regulators etc , complete all as specified and directed for the followings:- |
| 133 | (a) One light /Ceiling fan/exhaust fan point controlled by one switch. |
| 134 | Supply and fixing LED FLAME PROOF light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protectionwith die cast aluminum housing with heat resistanttoughened glass with LED tube light fixtures driver,holders, connector etc. Complete with all accessoriesprewired and including connecting up with threecore flexible copper conductor cable with suitable size, all as specified and as directed. |
| 135 | S&F switch Flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 136 | S&F LED FLOOD LIGHT 70 watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistantcomplete with driver and lamp complete all as specified and directed. |
| 137 | M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including PVC cashing caping at surafce for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 4 Sqmm size stranded conductor as earthwire. |
| 138 | M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire |
| 139 | S&F modular type AC box single pole and Neutral with a two pin earth plug and socket complete with a mini MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed. |
| 140 | S & F water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet wwater connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 2.0 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed . |
| 141 | S&F bib tap 15mm bore of cast copper alloy (heavy duty) CP fancy type scrwed to iron pipe and fixed complete all as specified and directed. |
| 142 | S&F stop cock of 15 mm dia cast copper alloy (heavy duty) CP fancy type screwed for iron pipe and fixed complete all as specified and directed. |
| 143 | Cutting chases for concealed water tubing or concealed conduct wiring etc and making good cutting n exc 10cm girth in brick wall complete all as specified and directed. |
| 144 | Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete. |
| 145 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor two run and drawing in & including rigid PVC conduit in walls and on surface conduit for Beam/Ceiling/Column portion FRLS grade ,ISI marked , terminal box of suitable thickness and with 3 mm thick hylam sheet cover as per required cutting for terminal boxes also including provision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly and making good to the disturb surfaces with cement, matching with existing color by painting all as specified for the following :- One light/fan/bell point controlled by one by one way switch ( switch to be measured and paid separtely)Note :- Point wiring drawn in PVC concealed conduit as per site requirement all as specified and directed. |
| 146 | All as per item No 2 above but with single core copper conductor cable FLRS 2.50 sqmm for one 3 pin geyser box outlet, 10 Amps concealed and including provision of 2.50 Sqmm PVC insulated single core copper conductor cable as earth continuity conductor on independent board. |
| 147 | M&L switch piano flush type 6 Amp SP one way. |
| 148 | S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed. |
| 149 | S&F surface mounting LED Integrated Aluminium Batten luminarie Polycarbonate co-extusion tube 10W LED light 2 ft housing. An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. |
| 150 | S&F of factory made epoxy polyester powder coated distribution board SP & N 4 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 2 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 including taking down old DBs all as specified and directed.NOTE :-(a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 151 | S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed. |
| 152 | S&F of SPN MCB 40 amp, 240 V, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. |
| 153 | S&F of 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP 65 Protection, System level efficacy of the Luminary is =>100 lm/W, Power Factor =>0.90, Colour Temperature 3000K-6500K, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 154 | S&F exhaust fan metallic type ventilating single phase 230/240 V Of 300 mm sweep with louver shutter including cutting of holes in a round shape and including fixing the ventilating fan complete all as directed and specified. |
| 155 | S&F of 35 watts 230 V AC outdoor type with High efficient LED Building security light fitting with high pressure die cast Aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP: 65/66 protected complete with bracket made out of 32 mm GI pipe light grade 1.2 mtr long bend to shape with clamps and fixing bolts all as specified and directed. |
| 156 | M&L for earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.50 m below GL) connected with GI earth lead wire 4.0 mm as earthing leads by means of bolts, nuts, check nuts and washers all joints as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1 chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed at site. |
| 157 | S & F water heater storage type Geyser vertical type with suitable size of fastner and, inner tank material of superior glass line tank and outer body material of ABS with high pressure with standing enabling (up to 8 bar pressure) capacity including provision and connecting up of SS braidedpipe with adopter for inlet and outlet water connection having edjustable knob for temperature control and inner tank should be glass line coated, capacity 50 Ltrs, having heating element 2.0 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete all as specified and directed . |
| 158 | S&F in repair, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC armoured, PVC sheathed 6 sq. mm nominal cross section, 2 core complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail