| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m, disposed earth to be levelled and neatly dressed. As per DSR-2.6.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5 to 3.00 m, disposed earth to be levelled and neatly dressed. As per DSR-2.6.1+2.26.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 3.00 to 4.50 m, disposed earth to be levelled and neatly dressed. As per DSR-2.6.1+2.26.1.2and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50m and lift up to 4.5 to 6.00 m, disposed earth to be levelled and neatly dressed. As per DSR-2.6.1+2.26.1.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 5 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. As per DSR-2.25a and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 6 | Supplying and filling in plinth with local sand under floors, including watering, ramming, consolidating and dressing complete. As per DSR-2.27 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 7 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)As per DSR-4.1.8 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 8 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment(excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart. As per DSR-2.35.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 9 | Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying Excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.) R.C.C. work Upto plinth Lvl. (M-25) As per DSR-5.33.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 10 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : As per DSR 20.3.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns etc. for mass concrete as per DSR - 5.9.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Shuttering work in Slab as per DSR - 5.9.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams , plinth beam, girders, bressummers and cantilevers as per DSR - 5.9.5 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for column wall and pedestal etc as per DSR - 5.9.6 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 15 | Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying Excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. Note :- Cement content considered in this item @ 330 kg/cum. Excess or less cement used as per design mix is payable or recoverable separately.) R.C.C. work above plinth Lvl. (M-25) As per DSR-5.33.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in Foundation and Plinth in: Cement Mortar 1:4 (1 Cement : 4 Coarse sand As per DSR - 6.1.1. and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 in Foundation and Plinth in: Cement Mortar 1:6 (1 Cement : 6 Coarse sand As per DSR - 6.1.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation M-150 above plinth level : Cement Mortar 1:4 (1 Cement : 4 Coarse sand As per DSR - 6.4.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 19 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately) As per DSR - 6.47 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 20 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work As per DSR 6.38 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 21 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. As per DSR - 4.13 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 22 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. As per DSR - 22.7.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 23 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece As per DSR 10.5.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 24 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. As per DSR 9.20.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 35 mm thick shutters As per DSR 9.5.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 26 | Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: As per DSR-10.14.2.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid forseparately) For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) As per DSR-21.1.1.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 28 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). as per DSR- 21.17 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 29 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete With 12 mm mild steel U beading As per DSR - 9.135.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 30 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). As per DSR - 21.18 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 31 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes As per DSR - 10.30.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 32 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. As per DSR 10.31 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 33 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.As per DSR- 5.22.6 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 34 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) As per DSR - 13.5.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 35 | 12 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)As per DSR-13.4.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 36 | 12 mm cement plaster on rough side of single or half brick wall of mix : 1:3 (1 cement: 3 coarse sand)As per DSR-13.9.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 37 | 6 mm plaster on cement concrete or reinforced cement concrete work with white cement based polymer modified self curing mortar of approved make as per the direction of Engineer-In-Charge.. As per DSR-13.86 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 38 | Making Drip course/ groove in plastered surface or moulding to R.C.C. projections. As per DSR No. 5.30 and direction of E/I. and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 39 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate As per DSR 11.3.1 and direction of E/I. and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 40 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. As per DSR 11.6 and direction of E/I.(Including all taxes, Labour cess but exluding GST) |
| 41 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm. As DSR 11.41.2 per direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 42 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm As per DSR - 11.47.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 43 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick As per DSR - 11.26.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 44 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. As per DSR-11.27 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 45 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. As per DSR-11.37 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 46 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. As per DSR 8.31 and direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 47 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab upto 0.50 sqm As per DSR 8.2.2.1 and direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 48 | 38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.. As per DSR-11.34 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 49 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. As per DSR-13.48.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 50 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). as per DSR-13.47.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 51 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour all complete, as per manufacturer's specification. New work ( two or more coats ) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. As per DSR-13.41.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 52 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. As per DSR-13.80 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 53 | Finishing wall with water proof cement paint (New Work two or more coats) . As per DSR-13.44 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 54 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 55 | Providing and fixing stainless steel tower bolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 56 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 57 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. As per DSR-9.82 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 58 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment. As per DSR-11.19.4 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 59 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. As per DSR- 22.5 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 60 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. As per DSR-10.28 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 61 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding As per DSR-14.72 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 62 | Providing and fixing in position collapsible steel shutters with vertical channels 20x1 with top and bottom rails of T-iron 40x40x6 mm , with 38 mm dia steel pulleys with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved red lead paint. As per DSR-10.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 63 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover As per DSR- 10.6.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 64 | Providing and fixing ball bearing for rolling shutters As per DSR-10.7 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 65 | Providing & Installation of Microcell Polycarbonate panels of 16mm thick (min.) single panel. Panel Width shall not be less than 1040 mm to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The panels shall be uniform in color with an integral Microcell/Multicell. Panels shall be manufactured with Vertical Standing Seam with maximum height 15mm at both sides of the panel. Snap-on connector to interlock the panels shall have a double tooth grip-lock locking mechanism to ensure maximum uplift capability. Panel shall be with additional End- cap/Aluminum U-Profile (mill finish) for ends. Panels shall be co-extruded UV protected. Panel shall be fixed over structural steel / MS purlin conforming to the detail technical specifications enclosed and as per approved shade / colour and directions of Engineer-In-Charge. As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 66 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubesAs per DSR-10.16.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 67 | Appron drain 150x150 along appron.As per Analysis and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 68 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Group of two or more piles upto 50 tonne Safe capacity. Initial test (Test Load 2.5 times the Safe capacity)As per DSR-20.6.3.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 69 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Group of two or more piles upto 50 tonne Safe capacity. Routine test (Test Load 1.5 times the Safe capacity) As per DSR-20.6.3.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 70 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests As per DSR-17.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 71 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid As per DSR-17.2.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 72 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps As per DSR-17.7.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 73 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.32 mm dia As per DSR-17.28.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 74 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40 mm dia As per DSR-17.28.1.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 75 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. As per DSR-17.31 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 76 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :510x1040 mm bowl depth 250 mm As per DSR-17.10.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 77 | Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern As per DSR-17.5.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 78 | Providing and fixing PTMT Bottle trap for Wash basin and sink 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms As per DSR-17.70.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 79 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. As per DSR-17.71 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 80 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. As per DSR-17.73.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 81 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore As per DSR-18.21.2.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 82 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 15 mm nominal bore As per DSR-18.49.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 83 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore As per DSR-18.51.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 84 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 15 mm nominal bore As per DSR-18.53.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 85 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter As per DSR-18.22.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 86 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15mm nominal bore As per DSR-18.52.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 87 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm As per DSR-12.43.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 88 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter As per DSR-12.41.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 89 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Bend As per DSR-12.42.5.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 90 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree 110 mm Shoe As per DSR-12.42.6.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 91 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. As per DSR-12.44 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 92 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete As per DSR-12.22 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 93 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes As per DSR-18.8.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 94 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes As per DSR - 18.8.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete Internal work-Exposed on wall as per direction of Engineer in Charge.25mm dia nominal bore. As per DSR-18.9.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 96 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete Internal work-Exposed on wall as per direction of Engineer in Charge.32mm dia nominal bore. As per DSR-18.9.4 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 97 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete Internal work-Exposed on wall as per direction of Engineer in Charge.40mm dia nominal bore. As per DSR-18.9.5 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 98 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete Internal work-Exposed on wall as per direction of Engineer in Charge.50mm dia nominal bore. As per DSR-18.9.6 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 99 | Providing and fixing gun metal gate valve with wheel of approved quality.25mm dia nominal bore As per DSR-18.17.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 100 | Providing and fixing gun metal gate valve with wheel of approved quality.32mm dia nominal bore As per DSR-18.17.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 101 | Providing and fixing gun metal gate valve with wheel of approved quality.40mm dia nominal bore As per DSR-18.17.3 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 102 | Providing and fixing brass stop cock of approved quality. 20 mm nominal bore As per DSR-18.16.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 103 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. As per DSR-18.48 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 104 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 110mm dia P.V.C. pipe As per NS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 105 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. 90mm dia P.V.C. pipe As per NS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 106 | Providing & fixing UPVC Floor trap of self cleansing design with CP Jali complete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90 mm As per NS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 107 | Providing and fixing terminal guard. 110mm. As per NS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 108 | Providing and fixing terminal guard. 75mm. As per NS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 109 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. up to 1.50 m depth Pipes 80 mm to 300 mm diameter As per DSR-2.10.1.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 110 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150 mm. dia. RCC Pipes . As per DSR-19.6.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 111 | Providing and laying cement concrete1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design 150 mm. dia. As per DSR-19.3.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 112 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). . As per DSR-19.7.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 113 | Size 90x80cm with With common burnt clay FPS (non modular) bricks of class designation 7.5.As per DSR-19.8.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 114 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. As per DSR-19.16 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 115 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P typeWith Sewer bricks conforming to IS : 4885As per DSR-19.4.2.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 116 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 80mm nominal bore. As per DSR-18.12.8 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 117 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 65mm nominal bore. As per DSR-18.12.7 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 118 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. (external work) 50mm nominal bore. As per DSR-18.12.6 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 119 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.65mm nominal bore. As per DSR-18.17.5 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 120 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc.50mm nominal bore. As per DSR-18.17.4 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 121 | Constructing brick masonry chamber 600 x 600 x 750 mm inside with F.P.S. brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mm top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20 mm nominal size); necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1 : 3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design .As per DSR-18.33.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 122 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) As per DSR-5.1.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 123 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttring, finishing and reinforcement- All work above plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) As per DSR-5.2.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 124 | Providing and fixing 75mm dia Vent PIPE As per DSR-17.35.2.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 125 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality M.D. -10- Circular shape 500mm internal diameter. As per DSR-19.19.2.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 126 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality M.D. -2.5- Circular shape 450 mm internal diameter. As per DSR-19.19.2.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 127 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks. As per DSR-19.32.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 128 | Rain Water Harvesting Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Drilling of 300mm dia bore hole manually. As per DSR-23.2.1.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 129 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia. As per DSR-23.4.2 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 130 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 131 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 10 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 132 | Supplying, filling, spreading & leveling stone boulders of size range 1.5 mm to 2 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 133 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. As per MR and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 134 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick As per DSR 11.13.1 and direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 135 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. As per DSR 11.4 and direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 136 | Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 300 mm dia single reamed pile As per No. 20.3.1direction of E/I. (Including all taxes, Labour cess but exluding GST) |
| 137 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 As per DSR No. 16.78.1direction of E/I.(Including all taxes, Labour cess but exluding GST) |
| 138 | Providing and laying 80 mm thick faciory made cement concrete interlocking paver block of M -35 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete As per DSR No. 16.91.2 and direction of E/I.(Including all taxes, Labour cess but exluding GST) |
| 139 | Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads/ pavements all complete as per directionof the Engineer-In-Charge.. As per DSR-16.46.1 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 140 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore As per DSR-18.12.8 and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 141 | Instalation of Tubewell depth 150 RM and 7.50 HP Submercible Pump including cost of all material, labour T&P etc. As per Design Drawing and TS and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 142 | Credit dismentaling cost of existing building at site . As per analysis of rate and Direction of E/I (Including all taxes, Labour cess but exluding GST) |
| 143 | Note-Debit cost of scrap vlaue of material of existing building at site . As per analysis of rate and Direction of E/I (Including all taxes, Labour cess but exluding GST) (Amount Rs. 1150000.00 shall be deducted from contractor as a scrap value in this item) |
| 144 | Point wiring-- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 145 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,with 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 146 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 147 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 148 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 149 | Supply and fixing 3 pin 5A celling rose on the existing Junction box including connection as required (Including all taxes, Labour cess but exluding GST) |
| 150 | Supply and fixing Batten / angle holder including connection as required (Including all taxes, Labour cess but exluding GST) |
| 151 | Supply and fixing Call bell / buzzer suitable for single phae 230V including connection as required (Including all taxes, Labour cess but exluding GST) |
| 152 | Providing fixing of circular / Hexgonal cast iron or MS sheet bos for celling fan clamp of internal 140mm ,73mm height , top lid of 1.5mm thick MS sheet with its top surface for proper bonding top lid shall be screwed into cast iron / MS box by means od 3.3mm dia round headed srews one lock at corner clamp shall be made of 12mm dia MS bar bent to shape as per standard drawing (Including all taxes, Labour cess but exluding GST) |
| 153 | Supply and fixing of following sizes medium class PVC conduit pipe along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required size 20mm (Including all taxes, Labour cess but exluding GST) |
| 154 | Supply and fixing of following sizes medium class PVC conduit pipe along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required size 25mm (Including all taxes, Labour cess but exluding GST) |
| 155 | Supplying and drawing of 0.5 mm dia FRLSH PVC insulated anneleaed copper conductor unarmoured telephone cable in the existing surface / recessed steel / PVC conduit as required 4 pair cable (Including all taxes, Labour cess but exluding GST) |
| 156 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, NonPlenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required. 3 run cable (Including all taxes, Labour cess but exluding GST) |
| 157 | Supplying and fixing following socket on the existing switch box / cover plate including connection ec as required for Telephone socket out let (Including all taxes, Labour cess but exluding GST) |
| 158 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. (Including all taxes, Labour cess but exluding GST)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (Including all taxes, Labour cess but exluding GST) |
| 159 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. (Including all taxes, Labour cess but exluding GST)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (Including all taxes, Labour cess but exluding GST) |
| 160 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. (Including all taxes, Labour cess but exluding GST)2 X 4 sq. mm + 1 X 4 sq. mm earth wire (Including all taxes, Labour cess but exluding GST) |
| 161 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. (Including all taxes, Labour cess but exluding GST)2 X 6sq. mm + 1 X 6sq. mm earth wire (Including all taxes, Labour cess but exluding GST) |
| 162 | 4X16sq. mm + 2 X 6sq. mm earth wire (Including all taxes, Labour cess but exluding GST) |
| 163 | Supplying and drawings of FRLS PVC insulated copper conductor, single core multistrand cable in the existing surface/recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm for inverter etc. (Including all taxes, Labour cess but exluding GST) |
| 164 | Panel , Distribution board,--S/f of following ways surface/recess mounting, vertical type 415V, TPN MCB distribution board of sheet steel. Dust protected, duly powder paiunted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 4way (4+12) double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 165 | S/f of following ways surface/recess mounting, vertical type 415V, TPN MCB distribution board of sheet steel. Dust protected, duly powder paiunted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 8way (4+24) double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 166 | S/f of following ways ,horizontal type three pole and neutrl sheet (TPN DB) distribution board 415 V on surface surface/recess mounting complete with tinned copper bus bar, common neutral bus bar , earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required4way (4+12) double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 167 | S/f of following ways ,horizontal type single pole and neutrl sheet (SPN DB) distribution board 240 V on surface surface/recess mounting complete with tinned copper bus bar, common neutral bus bar , earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 8way double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 168 | Supply and fixing of cable end box (Loose wire box) suitable for following tripple pole and neutral sheet steel MCB DB (TPNDB) 415 V on srfac e/ recess comlete in all respect -4 way TPN DB (Including all taxes, Labour cess but exluding GST) |
| 169 | Supply and fixing of cable end box (Loose wire box) suitable for following tripple pole and neutral sheet steel MCB DB (TPNDB) 415 V on srfac e/ recess comlete in all respect -For V TPN DB (Including all taxes, Labour cess but exluding GST) |
| 170 | S&F of 100 Amp 4 pole MCCB(25 KA) Thermal Magnetic release (C) cat A (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 171 | S&F of 40Amp 4 pole MCB(25 KA) Thermal Magnetic release (C) cat A (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 172 | Suplying and fixing of four pole (three phase and neural ) 415 Volt RCCB , having a sensitivity current 3MA in the existing MCB DB complete with connection testing and commissioning etc as required Rating 40A (Including all taxes, Labour cess but exluding GST) |
| 173 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 174 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 175 | Supply & Erracetion of factory fabricated & wiredmetal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cableentreis Electrical control panel with TPN MCCB's(Four Pole 36 KA with thermal magnaticrelease)Switches Complete and instrument chamberetc.complete in all respects. The instrument chambershall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp onincoming etc.The Job includes the grounting of the board as perdirections of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicletype switch board shall be of cat A & B Only.Incoming ----630Amp 4 pole MCCB -1 nos Out going--200 Amp MCCB 4 pole-3nos 100Amp MCCB 4 pole-3nos, 63 Amp-2nos (Including all taxes, Labour cess but exluding GST) |
| 176 | Supply & Erracetion of factory fabricated & wiredmetal clad dust and vermin proof floor mounting,M.S. Channel Base with bottom and top cableentreis Electrical control panel with TPN MCCB's(Four Pole 36 KA with thermal magnaticrelease)Switches Complete and instrument chamberetc.complete in all respects. The instrument chambershall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp onincoming etc.The Job includes the grounting of the board as perdirections of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicletype switch board shall be of cat A & B Only.Incoming ----200Amp 4 pole MCCB -1 nos Change over Switch 4 pole 200Amp- 1 nos Out going--40Amp MCCB 4 pole- 8nos (Including all taxes, Labour cess but exluding GST) |
| 177 | Light and fan fixtures-Supply of Fresh air fan 200 mm (Including all taxes, Labour cess but exluding GST) |
| 178 | Supply of Exhaust fan 450mm (Including all taxes, Labour cess but exluding GST) |
| 179 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Rating 18 to 22 W (Including all taxes, Labour cess but exluding GST) |
| 180 | LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Rating- 40W (Including all taxes, Labour cess but exluding GST) |
| 181 | LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt) Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures WordMark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) Rating -40W (Including all taxes, Labour cess but exluding GST) |
| 182 | LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt) Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim . Rating 22W (Including all taxes, Labour cess but exluding GST) |
| 183 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Rating 100W (Including all taxes, Labour cess but exluding GST) |
| 184 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) (Including all taxes, Labour cess but exluding GST) |
| 185 | Supply and fixing ofLED bulb 9W (Make - Havells/Philips/ Bajaj) (Including all taxes, Labour cess but exluding GST) |
| 186 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Up to 450mm (Including all taxes, Labour cess but exluding GST) |
| 187 | Extra for fixing of Louvers/ shutters completed with frame for ex fan (Including all taxes, Labour cess but exluding GST) |
| 188 | cables -Providing Laying of GI pipe in ground complete with GI fitting including trenchining (75 mm depth ) refilling etc as required 100mm (Including all taxes, Labour cess but exluding GST) |
| 189 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.400 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 190 | Same as above but for Size-.95sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 191 | Same as above but for Size-.50 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 192 | Same as above Size-.25 sq. mm 3-1/2 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 193 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 400 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 194 | Same as above but for Size- 95 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 195 | Same as above but for Size- 50 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 196 | Same as above but for Size- 25 sq. mm 3-1/2 core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 197 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-400 Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 198 | Same as above but for Size-95 Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 199 | Same as above but for Size-50Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 200 | Same as above but for Size-25Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 201 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Including all taxes, Labour cess but exluding GST) |
| 202 | S/F 2 No. 6 SWG GI wire (Including all taxes, Labour cess but exluding GST) |
| 203 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all taxes, Labour cess but exluding GST) |
| 204 | Lighting Arrester for Building -Proving and fixing of Lightining conductor finial made of 25mm dia 300mm long , GI tube , having single prong at top with 85 mm dia 6 mm thick GI base plate including holes etc complete as required (Including all taxes, Labour cess but exluding GST) |
| 205 | Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) byriveting / nut bolting/ sweating and soldering etc as required (Including all taxes, Labour cess but exluding GST) |
| 206 | Providing Fixing GI tape 20x3mm thick on parapet or surface of wall for Lightining conductor complete as required (for Horizental run ) (Including all taxes, Labour cess but exluding GST) |
| 207 | Providing Fixing GI tape 20x3mm thick on parapet or surface of wall for Lightining conductor complete as required (for Vertical run ) (Including all taxes, Labour cess but exluding GST) |
| 208 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. (Including all taxes, Labour cess but exluding GST) |
| 209 | Supply and burring of GI earth plate 600mm x 600mm x 6mm thick including accessoriesand providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7mtr long etc with required material etc (Including all taxes, Labour cess but exluding GST) |
| 210 | Supply and fixing of 9 mtr GI octagonal pole of approved make (top dia 70mm , bottom dia 155mm and Base plate16mm thick )having 3mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC foundation bolt including the cost of foundation , excavation & back filling and required T&P complete in all respect (Including all taxes, Labour cess but exluding GST) |
| 211 | S/f of following ways ,horizontal type single pole and neutrl sheet (SPN DB) distribution board 240 V on surface surface/recess mounting complete with tinned copper bus bar, common neutral bus bar , earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required 8way double door (Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 212 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole(Make - Havells/ Anchor/ Legrand) (Including all taxes, Labour cess but exluding GST) |
| 213 | Supply and fixing of 63Amp TPN 415 Vswitch disconnector fues (Including all taxes, Labour cess but exluding GST) |
| 214 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends asper LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Rating 150W (Including all taxes, Labour cess but exluding GST) |
| 215 | Supply and fixing of Decorative bollard light 40 to 45watt LED post top indirect light luminarieshaving presure die cast aluminium body and UV stablized PC clear/ frosted glass cover, with driver set confirming to IPP 66 and 1k 08 protection , potted driver complet ein all respect sy 4800-5400 system lumenstem lumen ,>120 lm/ W P.F>0.95. THD<10% at full load, CRI>70, potted driver set in metal housing ( not circuilatory ) pha eto phase protection at 440V &, >300 V auto cut and restart feature with 5 year warranty (Including all taxes, Labour cess but exluding GST) |
| 216 | Supplying and drawings of FRLS PVC insulated copper conductor, single core multistrand cable in the existing surface/recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm for street light (Including all taxes, Labour cess but exluding GST) |
| 217 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.25sq. mm 3.5core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 218 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc Size-.10 sq. mm 4 core(Make - Havells/ Anchor/ Polycab) (Including all taxes, Labour cess but exluding GST) |
| 219 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 25 sq. mm 4 core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 220 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. Size- 10 sq. mm 3core (Make - Havells/ Anchor/Dowells) (Including all taxes, Labour cess but exluding GST) |
| 221 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-25 Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 222 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size-10 Sqmm (Make - Dowells or equivalent) (Including all taxes, Labour cess but exluding GST) |
| 223 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Including all taxes, Labour cess but exluding GST) |
| 224 | S/F 2 No. 6 SWG GI wire (Including all taxes, Labour cess but exluding GST) |
| 225 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all taxes, Labour cess but exluding GST) |
| 226 | fire alarm Supplying, installation, testing & commissioning of heat detector operating at 54ºC/57ºC with rate of rise cum fixed temperature (dual thermistor) type with mounting base complete with all connection etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 227 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 228 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Including all taxes, Labour cess but exluding GST) |
| 229 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Including all taxes, Labour cess but exluding GST) |
| 230 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DCsupply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt 30 AH each sealed maintenance free batteries -1 set. (Including all taxes, Labour cess but exluding GST) |
| 231 | Supply and fixing of following size of steel conduit along with accessories in surface / recess including painting in case of surfase conduit or cutting the wall and making good the same in case of recess conduit size 20mm (Including all taxes, Labour cess but exluding GST) |
| 232 | Supply and fixing of following size of steel conduit along with accessories in surface / recess including painting in case of surfase conduit or cutting the wall and making good the same in case of recess conduit size 25mm (Including all taxes, Labour cess but exluding GST) |
| 233 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sqmm (Including all taxes, Labour cess but exluding GST) |
| 234 | Supplying and drawing following sizes of FRLSH PVC insulated copper conductor , single core cable in the existing surface / recessed stell /PVC conduit size- 2x1.5sqmm (Including all taxes, Labour cess but exluding GST) |
| 235 | Supplying and drawing following sizes of FRLSH PVC insulated copper conductor , single core cable in the existing surface / recessed stell /PVC conduit size- 3x1.5sqmm (Including all taxes, Labour cess but exluding GST) |
| 236 | Same as above but for size150 mm dia (Including all taxes, Labour cess but exluding GST) |
| 237 | Same as above but for size100 mm dia (Including all taxes, Labour cess but exluding GST) |
| 238 | Same as above but for size 80 mm dia (Including all taxes, Labour cess but exluding GST) |
| 239 | Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required Single headed Stainless steel (Including all taxes, Labour cess but exluding GST) |
| 240 | Supplying and fixing first aid Hose Reel with MS construction spray painted n post officered,conforming to IS-884complete with the following as required.20mm nominal internal dia water hose thermoplastic(Textile reinforced) type -2 as per IS: 1258520mm nominal internal dia gunmetal globe valve&nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25mm dia stop gun metal valve & M.S. Pipe and socket 30 M long (Including all taxes, Labour cess but exluding GST) |
| 241 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required Gun Metal (Including all taxes, Labour cess but exluding GST) |
| 242 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required- Stainless Steel (Grade 304) (Including all taxes, Labour cess but exluding GST) |
| 243 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia (Including all taxes, Labour cess but exluding GST) |
| 244 | same as above but for size 100 mm dia (Including all taxes, Labour cess but exluding GST) |
| 245 | same as above but for size 150 mm dia (Including all taxes, Labour cess but exluding GST) |
| 246 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required size 100mm dia (Including all taxes, Labour cess but exluding GST) |
| 247 | same as above but for size 150mm dia (Including all taxes, Labour cess but exluding GST) |
| 248 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (Including all taxes, Labour cess but exluding GST) |
| 249 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 4 way-150 mm dia M.S. Pipe (Including all taxes, Labour cess but exluding GST) |
| 250 | A) Supplying, installation, testing and commissioning of electric driven terrace pump 450LPM 35 mtr Head ,10HPsuitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. E) Suitable cement concrete foundation duly plastered and with anti vibration pads. (Including all taxes, Labour cess but exluding GST) |
| 251 | Providing&fixing of pressures switch in M .S . pipeline including connection etc. as required (Including all taxes, Labour cess but exluding GST) |
| 252 | Same as above but for size 150mm dia (Including all taxes, Labour cess but exluding GST) |
| 253 | SITC of Automatic starter panel suiatable for tarrace pump 10Hp complete in all respect (Including all taxes, Labour cess but exluding GST) |
| 254 | Providing&fixing of hose box wall mounting type made out of 16 gauge ms sheet to accommodate 2 x15 mtr length of hose pipe , branch pipe, acrlic fronted double door, with lock two keys and break glass recess for keys painted fire red cost of materials and labour etc complete in all respect. (Including all taxes, Labour cess but exluding GST) |
| 255 | Providing and placing on terrace polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (Including all taxes, Labour cess but exluding GST) |
| 256 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cablerun shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. size 16 Sqmm 4 coe (Including all taxes, Labour cess but exluding GST) |
| 257 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction Size 16 Sqmm 4 core (Including all taxes, Labour cess but exluding GST) |
| 258 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharg Size 16 sqmm 4 core (Including all taxes, Labour cess but exluding GST) |
| 259 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (Including all taxes, Labour cess but exluding GST) |
| 260 | S/F 2 No. 6 SWG GI wire (Including all taxes, Labour cess but exluding GST) |
| 261 | Supply and laying of 25mm x 5mm G.I. strip from earth electrode directly in the ground as required complete in all respect. (Including all taxes, Labour cess but exluding GST) |
| 262 | Supply and fixing of fire extinguisher ,ABC Type 4.0 kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work (Including all taxes, Labour cess but exluding GST) |
| 263 | Supply and fixing of fire extinguisher ,CO2 Type6.5kg capacity (ISI Marked IS : 15683 & TAC approved (complete with initial charge and wall bracket ,along with supply of all materials and labour for proper completion of work. (Including all taxes, Labour cess but exluding GST) |
| 264 | Supply and fixing of four fire bucket with one stand fill with river sand supply of all materials and labour for proper completion of work. (Including all taxes, Labour cess but exluding GST) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail