Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Renovation work of Class room, Boundary wall, Canteen, Cycle Stand & Admin Building at Govt. I.T.I. Charbagh District-Lucknow (U.P.) |
| 2 | CIVIL WORKS (COLOR LAB & CLASS ROOM) |
| 3 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 4 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 5 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 6 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 7 | Providing and fixing Stainless steel sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. |
| 8 | Providing and fixing Stainless steeltower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 9 | 300 x 10mm |
| 10 | 200 x 10mm |
| 11 | Providing and fixing Stainless steelhandles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. |
| 12 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 12 mm mild steel U beading |
| 13 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 14 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 15 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 16 | One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work |
| 17 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 18 | Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) |
| 19 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs c) After two days ofproper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarsesand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above |
| 20 | Dismantling jack arched or wooden beam & barges roof.including beam and roof concrete and including stacking of materials as directed byby the Engineer-in-charges with in a distance of 60 meters(200ft.) |
| 21 | Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge |
| 22 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 23 | Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 24 | Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). |
| 25 | Disposal of Malba upto 8 Km |
| 26 | ELECTRICAL WORKS (COLOR LAB & CLASS ROOM) |
| 27 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 28 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 29 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 30 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 31 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 32 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet |
| 33 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 34 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 35 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 36 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 37 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 38 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 39 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 40 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door |
| 41 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 42 | 10 sqmm 2 core |
| 43 | 10 sqmm 4 core |
| 44 | 70 sqmm 3.5 core |
| 45 | 240 sqmm 3.5 core |
| 46 | Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCB's (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters(KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 47 | the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only. |
| 48 | Incoming : |
| 49 | 400 Amp. MCCB - 1No |
| 50 | Metering : |
| 51 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 52 | One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 53 | One (1) Set of Phase Indication Lamp. |
| 54 | Bus Bar : |
| 55 | One (1) No.500 A, TPN aluminimum bus bar of suitable length. |
| 56 | Outgoing : |
| 57 | Phase indication lamps on each outgoing to be provided. |
| 58 | 200Amp 4P MCCB - 1Nos. |
| 59 | 63Amp 4P MCB - 5Nos. |
| 60 | 40Amp 4P MCB - 4Nos. |
| 61 | 32Amp SP MCB - 2Nos. |
| 62 | 100Amp 4P MCCB - 1Nos.-Spare |
| 63 | 40Amp 4P MCB - 1Nos.-Spare |
| 64 | 63Amp 4P MCB - 1Nos.-Spare |
| 65 | SUB PANEL |
| 66 | Incoming : |
| 67 | 200 Amp. MCCB - 1No |
| 68 | Metering : |
| 69 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 70 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 71 | One (1) Set of Phase Indication Lamp. |
| 72 | Bus Bar : |
| 73 | One (1) No.250 A, TPN aluminimum bus bar of suitable length. |
| 74 | Outgoing : |
| 75 | Phase indication lamps on each outgoing to be provided. |
| 76 | 63Amp 4P MCB - 2Nos. |
| 77 | 40Amp 4P MCB - 2Nos. |
| 78 | 40Amp 4P MCB - 1Nos.-Spare |
| 79 | 63Amp 4P MCB - 1Nos.-Spare |
| 80 | Supply & fixing of 7/9 W LED BULB complete in all respect. |
| 81 | Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. |
| 82 | CIVIL WORKS (CLASS ROOM) |
| 83 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 84 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 85 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 86 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 87 | Providing and fixing Stainless steel sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. |
| 88 | Providing and fixing Stainless steeltower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 89 | 300 x 10mm |
| 90 | 200 x 10mm |
| 91 | Providing and fixing Stainless steelhandles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. |
| 92 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 12 mm mild steel U beading |
| 93 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 94 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 95 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 96 | One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work |
| 97 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 98 | Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) |
| 99 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs c) After two days ofproper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarsesand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above |
| 100 | Dismantling jack arched or wooden beam & barges roof.including beam and roof concrete and including stacking of materials as directed byby the Engineer-in-charges with in a distance of 60 meters(200ft.) |
| 101 | Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge |
| 102 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 103 | Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 104 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 25 mm thick |
| 105 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 106 | Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). |
| 107 | Disposal of Malba upto 8 Km |
| 108 | ELECTRIFICATION WORKS (CLASS ROOM) |
| 109 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 110 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 111 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 112 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 113 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 114 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet |
| 115 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 116 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 117 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 118 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 119 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 120 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 121 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 122 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door |
| 123 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 124 | 10 sqmm 2 core |
| 125 | 10 sqmm 4 core |
| 126 | 70 sqmm 3.5 core |
| 127 | 240 sqmm 3.5 core |
| 128 | Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCB's (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters(KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 129 | the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only. |
| 130 | Incoming : |
| 131 | 400 Amp. MCCB - 1No |
| 132 | Metering : |
| 133 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 134 | One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 135 | One (1) Set of Phase Indication Lamp. |
| 136 | Bus Bar : |
| 137 | One (1) No.500 A, TPN aluminimum bus bar of suitable length. |
| 138 | Outgoing : |
| 139 | Phase indication lamps on each outgoing to be provided. |
| 140 | 200Amp 4P MCCB - 1Nos. |
| 141 | 63Amp 4P MCB - 5Nos. |
| 142 | 40Amp 4P MCB - 4Nos. |
| 143 | 32Amp SP MCB - 2Nos. |
| 144 | 100Amp 4P MCCB - 1Nos.-Spare |
| 145 | 40Amp 4P MCB - 1Nos.-Spare |
| 146 | 63Amp 4P MCB - 1Nos.-Spare |
| 147 | SUB PANEL |
| 148 | Incoming : |
| 149 | 200 Amp. MCCB - 1No |
| 150 | Metering : |
| 151 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 152 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 153 | One (1) Set of Phase Indication Lamp. |
| 154 | Bus Bar : |
| 155 | One (1) No.250 A, TPN aluminimum bus bar of suitable length. |
| 156 | Outgoing : |
| 157 | Phase indication lamps on each outgoing to be provided. |
| 158 | 63Amp 4P MCB - 2Nos. |
| 159 | 40Amp 4P MCB - 2Nos. |
| 160 | 40Amp 4P MCB - 1Nos.-Spare |
| 161 | 63Amp 4P MCB - 1Nos.-Spare |
| 162 | Supply & fixing of 7/9 W LED BULB complete in all respect. |
| 163 | Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. |
| 164 | Networking and C.C.TV. System |
| 165 | CIVIL WORKS (ADMIN & ACADEMIC) |
| 166 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand |
| 167 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. |
| 168 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. |
| 169 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 170 | Providing and fixing Stainless steel sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete. (a) 250mm x 16mm. |
| 171 | Providing and fixing Stainless steeltower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete |
| 172 | 300 x 10mm |
| 173 | 200 x 10mm |
| 174 | Providing and fixing Stainless steelhandles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete (a) 125 mm. |
| 175 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete With 12 mm mild steel U beading |
| 176 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 177 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works.(b) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work. |
| 178 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. |
| 179 | One priming coat of cement primer and Two coat oil distemper on new work including supply of all materials labour and tools and plants etc required for proper completion of the work |
| 180 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 181 | Scraping old white or colour wash including disposal of refuse as directed by the Engineer-in- charge with in a distance of 60 mts.(200 ft) |
| 182 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5(1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm heightincluding rounding of junctions of walls and slabs c) After two days ofproper curing applying a second coat of cement slurry using 2.75 kg/ sqmof cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarsesand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge including laying glass fibre cloth ofapproved quality in top layer of plaster and finally finishing the surface withtrowel with neat cement slurry and making pattern of 300x300 mm square3 mm deep. e) The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test. All above |
| 183 | Dismantling jack arched or wooden beam & barges roof.including beam and roof concrete and including stacking of materials as directed byby the Engineer-in-charges with in a distance of 60 meters(200ft.) |
| 184 | Dismantling of existing plaster including disposal of refuse as directed by the engineer in charge |
| 185 | Supply and fixing 6 mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 300x300mm). |
| 186 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters :35 mm thick Single leaf |
| 187 | Dismantiling Door & window ,chowkhats with hold fast & including stacking of dismantled materials as directed by the engineer-in-charge with in a distance of 60 m (200ft) |
| 188 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 189 | Providing and laying 6 to 8 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 190 | Dismantling cement concrete or brick or granolithic floors including base concrete and including stacking of dismantled materials as directed by the Engineer-in-charge within a distance of 60 metre (200 feet). |
| 191 | Disposal of Malba upto 8 Km |
| 192 | ELECTRICAL WORKS (ADMIN & ACADEMIC) |
| 193 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 194 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 195 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 196 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 197 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 198 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. TV antenna socket outlet |
| 199 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 200 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 201 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 202 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. Including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 203 | Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required. |
| 204 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 205 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Disect Current(BLDC) motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value(CM/M/W) minimum 6, Air delivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 206 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 12 way, Double door |
| 207 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 208 | 10 sqmm 2 core |
| 209 | 10 sqmm 4 core |
| 210 | 70 sqmm 3.5 core |
| 211 | 240 sqmm 3.5 core |
| 212 | Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCB's (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters(KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 213 | the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only. |
| 214 | Incoming : |
| 215 | 400 Amp. MCCB - 1No |
| 216 | Metering : |
| 217 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 218 | One (1) No. (0-400A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 219 | One (1) Set of Phase Indication Lamp. |
| 220 | Bus Bar : |
| 221 | One (1) No.500 A, TPN aluminimum bus bar of suitable length. |
| 222 | Outgoing : |
| 223 | Phase indication lamps on each outgoing to be provided. |
| 224 | 200Amp 4P MCCB - 1Nos. |
| 225 | 63Amp 4P MCB - 5Nos. |
| 226 | 40Amp 4P MCB - 4Nos. |
| 227 | 32Amp SP MCB - 2Nos. |
| 228 | 100Amp 4P MCCB - 1Nos.-Spare |
| 229 | 40Amp 4P MCB - 1Nos.-Spare |
| 230 | 63Amp 4P MCB - 1Nos.-Spare |
| 231 | SUB PANEL |
| 232 | Incoming : |
| 233 | 200 Amp. MCCB - 1No |
| 234 | Metering : |
| 235 | One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. |
| 236 | One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. |
| 237 | One (1) Set of Phase Indication Lamp. |
| 238 | Bus Bar : |
| 239 | One (1) No.250 A, TPN aluminimum bus bar of suitable length. |
| 240 | Outgoing : |
| 241 | Phase indication lamps on each outgoing to be provided. |
| 242 | 63Amp 4P MCB - 2Nos. |
| 243 | 40Amp 4P MCB - 2Nos. |
| 244 | 40Amp 4P MCB - 1Nos.-Spare |
| 245 | 63Amp 4P MCB - 1Nos.-Spare |
| 246 | Supply & fixing of 7/9 W LED BULB complete in all respect. |
| 247 | Supply and fixing of LED Tube Light with batten suitable for up to 1X20 watt LED tube light complete including tube etc. on surface complete in all respect. |
| 248 | Networking and C.C.TV. System |
| 249 | CONSTRUCTION OF BOUNDARY WALL |
| 250 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds of soil |
| 251 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 252 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 253 | Upto plinth level |
| 254 | (i) R.C.C. work in Footing |
| 255 | (ii) R.C.C. work in Beam |
| 256 | Above plinth to floor-V lvl |
| 257 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 258 | (iii) R.C.C. work in Columns |
| 259 | (ii) R.C.C. work in Beam |
| 260 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 261 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 262 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 263 | Columns,Pillars, Piers, Abutments, Posts and Struts. |
| 264 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 265 | M-150 brick work in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 266 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 267 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 268 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. 1:6 (1 cement: 6 coarse sand) |
| 269 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 270 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 271 | REPAIR OF BOUNDARY WALL |
| 272 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 273 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 274 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 275 | INTERLOCKING |
| 276 | Earth work in exacavation in t. in ordinary soil(loan clay or sand) including lift upto 1.5 m and dressing of sides and ramming of bottom sand disposal of surplus excavated earth as directed by the Engineer i/c with in alead of 50m. |
| 277 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work, in foundation and floors. |
| 278 | Class M-150 brick work in 1:4 cement coarse sand (of 2.5 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 279 | Interlocking Tiles-Rubber moulded refiective Zig-Zag 80mm Providing and laying of Interlocking Concrete Block Laying of Pavements having thickness 80mm including levelling and dressing of surface to required level and slope, spreading and moisting 30m thick local sand on bend, filling joints with local sand on bend, filling joints with local sand etc for proper completion of the work as per drawing and technical specification clause 1504 |
| 280 | CYCLE STAND |
| 281 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 282 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 283 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 284 | Upto plinth level |
| 285 | (i) R.C.C. work in Footing |
| 286 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
| 287 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 288 | P/F Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 289 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 290 | Steel work in built up tublar trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer,elded and bolted including special shapped washers etc. complete: Electric resistance or induction butt welded tubes. |
| 291 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 292 | Steel Painting:Applying priming coat:(a) With ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. |
| 293 | Interlocking Work |
| 294 | EXTERNAL LIGHTING WORKS |
| 295 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded sotne aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 296 | Painting with aluminium paint of approved brand and manufacture to given an even shed. Two or more coats on new work |
| 297 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40mm dia |
| 298 | Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required. 3X2.5 sqmm |
| 299 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 300 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 301 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 302 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 303 | Upto 35 sq. mm |
| 304 | Above 185 sq. mm and Upto 400 sq. mm. |
| 305 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 306 | 2 X 6 sqmm. (19mm) |
| 307 | 2 X 10 sqmm. (19mm) |
| 308 | 4 X 10 sqmm. (25mm) |
| 309 | 3.5 X 240 sqmm. (62mm) |
| 310 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 311 | Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/lighting DBs for automatic switching On & Off of street lights at sunset & sun risr or twillight(Auto On, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c progamming at site complete required.02 output per phase and suitable for single phase supply |
| 312 | L.T. FEEDER PILLER |
| 313 | Supplying assembling erecting connecting, testing and commissioning of feeder pillar with over voltage and under voltage relay with auto re-setting, manufactured using 1.9/1.6 mm thick CRCA sheet steel with power coated paint double door (front operated)with canopy base channel and cable gland entry from bottom for cable using, suitable alluminium busbar with provision of incoming & outgoing MCCB/MCB of L&T/Schneider/GE/ABB or Eq. make. Installation of feeder pillar of suitable c.c. foundation etc complete in all respect. |
| 314 | Incoming : |
| 315 | 1No. Of 400 Amps FP MCCB of 36 KA service breaking capacity and 400 Amp trip setting. |
| 316 | Metering : Voltmeter, Ammeter, Indication |
| 317 | Bus Bar : |
| 318 | 1 Set of 500 Amps TPN Aluminium Bus Bars of suitable length and of cross section . Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of 36 KA at 415 volts. |
| 319 | 3Nos. Phase indicating lamp each lamp shall have one toggle switch . |
| 320 | Outgoing : |
| 321 | Phase indication lamps on each outgoing to be provided. |
| 322 | 400Amp FP MCCB (36 kA) - 1 Nos. |
| 323 | 63 Amp. FP MCB- 1 No. -Spare |
| 324 | Supply of following size of 1.1 KV grade multicore aluminium conductor PVC sheathed armoured cable as per IS 1554. Make-Polycab or Eq |
| 325 | 6 sqmm 2 core |
| 326 | 10 sqmm 2 core |
| 327 | 10 sqmm 4 core |
| 328 | 240 sqmm 3.5 core |
| 329 | Supply of 7.50 m long steel tubular pole designated 410 SP-6 with single arm bracket including Clamps,bolts,nuts etc.complete in all respects. |
| 330 | Supply of LED street light fitting having die cast aluminium body and diffuser/reflector with driver set suitable for 75 watt to 90 Watt confirming to IP 66 protection complete in all respect. |
| 331 | EXTERNAL DRAIN WORKS |
| 332 | Constructing brick masonry open surface drain with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 fine sand) including earth excavation, 10cm thick bed concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and 25mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size) for filling haunches including 12mm cement plaster 1:4 (1 cement : 4 coarse sand ) with a floating coat of neat cement inside the drain, its top and exposed side including disposal of surplus earth complete as per standard design: Drain 30 cm drain 45 cm average depth |
| 333 | GST Extra as applicable Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail