| 1 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA [Through Rate] |
| 2 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] |
| 3 | [23.22.4.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing) [Through Rate] |
| 4 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole [Through Rate] |
| 5 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] |
| 6 | [23.22.8.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 8.2. SITC Four pole ON LOAD Manual change over switch in SS enclosure of following Ratings 100 amp 415 volts [Through Rate] |
| 7 | [23.3.1.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 1.2. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group B [Through Rate] |
| 8 | [23.3.4.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 4.2. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch required MS Box etc complete as required Group B [Through Rate] |
| 9 | [23.3.5.2]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 5.2. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch required MS Box etc complete as required Group B [Through Rate] |
| 10 | [23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate] |
| 11 | [23.3.6.3]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) [Through Rate] |
| 12 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 13 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 14 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 15 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 16 | [24.14.24]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 24. 16 Sq mm 4 core (Arm.) [Through Rate] |
| 17 | Supply and Erection of LED Batten 18/20W complete with in all respect.Make: Bajaj / Philips / Wipro / Surya Roshni |
| 18 | S/I/T/C of Passenger Elevator per the technical specifications and conditions mentioned herein. MAIN SPECIFICATIONS: TYPE : Gearless Passenger Elevator NO. LIFTS : 01 (One) CAPACITY : 680 Kg / 10 Person SPEED : 1.00 meter/Sec CONTROL : High Performance Simplex Full Collective Control System DRIVE : AC VVVF drive for more power saving, comfort and safe ride. BUILDING DATA STOP/OPENING : 03 Stops/ 03 Openings FLOOR : G, 1, 2. TRAVEL : 08 meters (Approx.) SHAFT SIZE : 1900 mm wide x 2100 mm OVERHEAD : 4800 mm (Available) PIT : 1600 mm (Approx.) M/C POSITION : Gearless Machine shall be placed above lift shaft in machine roomCAR ENCLOSURE , LANDING DOOR AND CAR DOOR SPECIFICATIONS CAR AREA INSIDE : 1300 mm Wide x 1350 mm Deep (1.75 Sq. meter) CAR ENCLOSURE : S.S Hairline Finish car, Granite flooring on heavy duty M.S. Platform, S.S. handrails at three side of car, decorative false ceiling with LED lighting, blower fan. CLEAR OPENING : 800 mm wide x 2000 mm Height. CAR DOOR : Center opening automatic door (S.S Hairline Finish) LANDING DOOR : Center opening automatic door (S.S Hairline Finish) POWER SUPPLY : Three Ø .415 V AC, 50 Hz plus /- 5% Single Ø 230 V AC, 50 Hz plus /- 5% DESIGN : These Components are generally confirmed as per Indian Standard Specification for Elevators or Escalators complete in all respect as per IS standards. Make: Otis/Kone/Mitsubishi/Schneider/Hitachi/Johnson/Orbis |
| 19 | S/I/T/C of Passenger Elevator per the technical specifications and conditions mentioned herein. MAIN SPECIFICATIONS: TYPE : Gearless Passenger Elevator NO. LIFTS : 01 (One) CAPACITY : 1088 Kg / 16 Person SPEED : 1.00 meter/Sec CONTROL : High Performance Simplex Full Collective Control System DRIVE : AC VVVF drive for more power saving, comfort and safe ride. BUILDING DATA STOP/OPENING : 03 Stops/ 03 Openings FLOOR : G, 1, 2. TRAVEL : 08 meters (Approx.) SHAFT SIZE : 2500 mm wide x 2100 mm OVERHEAD : 4800 mm (Available) PIT : 1600 mm (Approx.) M/C POSITION : Gearless Machine shall be placed above lift shaft in machine roomCAR ENCLOSURE , LANDING DOOR AND CAR DOOR SPECIFICATIONS CAR AREA INSIDE : 1600 mm Wide x 1600 mm Deep (2.56 Sq. meter) CAR ENCLOSURE : S.S Hairline Finish car, Granite flooring on heavy duty M.S. Platform, S.S. handrails at three side of car, decorative false ceiling with LED lighting, blower fan. CLEAR OPENING : 1000 mm wide x 2000 mm Height. CAR DOOR : Center opening automatic door (S.S Hairline Finish) LANDING DOOR : Center opening automatic door (S.S Hairline Finish) POWER SUPPLY : Three Ø .415 V AC, 50 Hz plus /- 5% Single Ø 230 V AC, 50 Hz plus /- 5% DESIGN : These Components are generally confirmed as per Indian Standard Specification for Elevators or Escalators complete in all respect as per IS standards. Make: Otis/Kone/Mitsubishi/Schneider/Hitachi/Johnson/Orbis Please Enable Macros to View BoQ information |