| 1 | Repair of 63 KVA Transformer incl. changing of HV & LV Coil, Bushing, Gasket & fresh transformer oil without returning of old & unsearciable material. Complete in all respects as per direction of E/I.(AOR) |
| 2 | Dis./Re-errection of 25/63/100/250 KVA Al. wound outdoor type Transformer as per ISS including fees as per direction of E/I.(AOR) |
| 3 | Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 4 | iii) 200 Amp 25KA TPMCCB ( DSR 2.2.5) |
| 5 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (KEI, Polycab, Havell's make) |
| 6 | (1) 50 Sq.mm. x 3.5 Core (PS No. 501) (492.0 + gst) |
| 7 | S/F of cable Lug(socket) to the cable lead. Complete in all respects as per PS No. 504 |
| 8 | a- 35 sq. mm (31.0 + gst) |
| 9 | b- 70 sq. mm (67.0 + gst) |
| 10 | Supply and making straight through joint with cast resin compound including ferrules and other joints material for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required |
| 11 | a) 3.5x70 sq. mm ((Electrical DSR-18/Ite. No. 9.3.20 pg.35) |
| 12 | Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) P-144) |
| 13 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138) |
| 14 | S/E of overhead line with ACSR conductor on steel tubular poles incl. compression joint, laying stringing and binding etc. as PS No. 627 |
| 15 | New Transformer oil for Transformer of approved make as per direction of E/I. |
| 16 | Dehydration charges of Transformer oil as per direction of E/I. |
| 17 | Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. (Electrial DSR-2018, Item No. 10.5) |
| 18 | (a) 120 Sqmm ( Item No. 10.5.2 P-37) |
| 19 | (b) 240 Sqmm ( Item No. 10.5.3 P-37) |
| 20 | Supply and making Straight Through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. (Electrial DSR-2018, Item No. 10.6) |
| 21 | (a) 120 Sqmm ( Item No. 10.6.2 P-38) |
| 22 | (b) 240 Sqmm ( Item No. 10.6.3 P-38) |
| 23 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC cost data book 2019/P-48) |
| 24 | S/F of out door type fuse set 11 KV Jai shree make insulator channel type Relco make complete in all respects as per direction of E/I. |
| 25 | Testing and servicing of 11KV VCB such as Programming of IDMT relay, Servicing of Breaker, Primary injection test on 11KV indoor type C.T. |
| 26 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (DSR civil I No. 15.2.1/P-258) |
| 27 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) (DSR civil-18/ I.No-4.1.6 / P-86). |
| 28 | Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46) |
| 29 | Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 pg.45) |
| 30 | Repairing of 11KV fuse wire/Jumper i/c supply and fixing of required size conductor, fuse wire of 11KV Line/DP structure of Transformer by takinng shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, shoes and other necessary items complete including all taxes. |
| 31 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by making experts technical staff. Complete in all respects as per direction of Engineer in charge (AOR) |
| 32 | Location and pin pointing of 11 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 33 | Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) |
| 34 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of soil.(Rate as per TAC order) |
| 35 | Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. 2.25/P-67 (Rate as per TAC order) Please Enable Macros to View BoQ information |