| 1 | Operation & maintenance of clear water booster pump sets, submersible pump set EI & Fans of staff qtrs. And street light at following locations as per inventory terms & conditions attached.a) Old Rajender Nagar.b) BaghRaoji,c) Dev Nagar,d) CC hosue Karol Baghe) Community Hall old Rajender Nagar. |
| 2 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface / recessed steel/PVC conduit including dismantling as required. -Group A. (DSR No. 1.15.1) |
| 3 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 4 | 3 x 4 sq. mm |
| 5 | 3 x 6 sq. mm |
| 6 | Dismentling, rewinding / repairing, greasing of following type ceiling fan / exhaust fan i/c re-installation connection testing etc. complete as reqd. |
| 7 | 48” ceiling fan |
| 8 | 300mm sweep exhaust fan |
| 9 | Supplying & Replacement(from deputed labour) of following items ( ISI marked) including connection, testing complete as required. |
| 10 | 5/6 Amp. Piano type switch |
| 11 | 15/16Amp. Piano type switch |
| 12 | 5/6 Amp. 3 pin socket outlet(Piano type) |
| 13 | 15/16 Amp. 6 pin socket outlet (Piano type) |
| 14 | 6 Amp. Bell push piano type |
| 15 | Call bell/Buzzer |
| 16 | Stepped stype modular fan regulator |
| 17 | PVC batten/Angle holder |
| 18 | 6-32 Amp. SP MCB 'C' curve 10 KA breaking capacity |
| 19 | 6-32 Amp. SP&N MCB (C- curve 10 KA breaking capacity) |
| 20 | 2.5mfd capacitor |
| 21 | 3.15mfd capacitor |
| 22 | 63 Amp. 2 pole isolator |
| 23 | 3 mm thick phenolic laminated sheet |
| 24 | Supply of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.a) Installation, Testing and Commissioning to be done by electrician/wireman |
| 25 | Supplying, installation testing, commissioning of 300mm sweep exhaust fan, silver in colour having 3 no. of blade i/c condenser, etc. complete as required. |
| 26 | Supplying & replacement of T5 Tube with 20 watt LED Batten from deputed labour i/c connection, testing etc. complete as required. |
| 27 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. A) 63 A - (DSR No. 2.13.2) |
| 28 | Dismantling, rewinding and re-assembling of 5 HP 3 Phase 415 volt induction motor, replacement of connection plate i/c varnishing, tapping connection, testing cartage to and fro etc. complete as required. |
| 29 | Repairing of 5 HP centrifugal Pump set i/c S/R of following worn out parts i.e. gland sleeve, neck ring, ball bearing, nut bolt, poacing and cartage to & fro i/c dismantling & reassembling, commissioning at site etc. as required. |
| 30 | Rewinding & Repairing of 3 HP submersible mono block pump set i/c dismantling & reassembling, commissioning at site etc. as required. Please Enable Macros to View BoQ information |