| Sl. No. | Item Description |
| 1 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast complete all as specified and directed. |
| 2 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each complete all as specified and directed. |
| 3 | Taking down shutter of any description exc 1 sqm but n exc 2 sqm each complete all as specified and directed. |
| 4 | S&F pressed steel frames size 105mm x 60mm for doors with one or more rebates including necessary fixing lung, hings, lock strike plate etc. complete all as specified and directed. |
| 5 | S&F pressed steel frames for door made out of MS Sheet 1.25mm thick of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 6 | M&L Plain cement concrete, M-15 (Nominal mix), type B-1 (Using 20mm graded stone aggregates) as in filling of steel chowkats or frames, cills and hold fast etc complete all as specified and directed. |
| 7 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of k value 58-60 (Suspension grade) calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900n (edge), minimum compressive strength 50n/mm2 modulus of elasticity 850 N/mm2 and resistance to spred of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC tobe laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhessive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessart full body threaded star headed counter sunk ss Screw complete all as specified and directed. |
| 8 | S&F factory made single extruded WPC (Wood Polymer Composite) glazed and skeleton shutter of size 35mm thick open rebated prepared to receive glass gauge etc without sash bars for securing glass , gauge etc comprising of virgin polymer of k value 58-60 (Suspension grade) calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 n (face) & 900n (edge), minimum compressive strength 50n/mm2 modulus of elasticity 850 N/mm2 and resistance to spred of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC tobe laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhessive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessart full body threaded star headed counter sunk ss Screw complete all as specified and directed. |
| 9 | M&L for Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 10 | M&L for Preparing the old steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel (ordinary tint) paint complete all as specified and directed. |
| 11 | S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing as per SSR Pt-II complete all as specified and directed. |
| 12 | S&F factory made solid PVC moulded door shutter with wood free EPS 28 to30mm thick(stiles) with 2 4 or 6 panels design with 2mm thick moulded prelam PVC sheet on the front face and 2 mm prelam PVC sheet on back face supplying and fixing in frame at site asper specifications and drawings as per SSR Pt-II complete all as specified and directed. |
| 13 | S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed. |
| 14 | S&F butt hinges 100mm, cold rolled medium weight mild steel complete all as specified and directed. |
| 15 | S&F 125mm size, extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 16 | S&F 150mm long aluminium tower bolts (ISI Marked) extruded type complete all as specified and directed. |
| 17 | S&F 300mm, Mild steel spring for door, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed. |
| 18 | S&F 300 mm size brass sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 19 | S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed. |
| 20 | M&L Sheet glass,4.8 mm thick ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 21 | M&L Anodised aluminium frame for doors, windows, ventilators with one or more rebates, including joing cleats for fixing etc complete all as specified and directed. |
| 22 | S & F Anodised aluminium window and ventilator shutters, side hung type without sash bars,, (powder coating of any colour and thickness not less than 50 micron) aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 23 | S & F Anodised aluminium three parallel tracks within the frame, allowing for three sliding panels for window and ventilator (two panels fixed with ordinary quality glass of thickness 5 mm and one panel fixed galvanised mild steel wire cloth 0.56 mm of nominal dia of each wire and average width of aperture 1.18 mm) (powder coating of any colour and thickness not less than 50 micron) aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as multi point lock,glass sealant etc, complete all as specified. Note:- The rate includes Three track frame , Three No panels(2 glass and 1 wire cloth including 5 mm thick glass and wire cloth as described in item description) complete all as specified and directed. . |
| 24 | S&F Anodised Aluminium grill (anodised transperent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design pattern, with approved standard section and fixed to the existing window frame with C.P. brass /stainless steel screws @ 200 mm centre to centre incuding cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 25 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-16 complete all as specified and directed. |
| 26 | S & F Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed. |
| 27 | Demolition of stone slabs and tiles of any description or thickness in floor,approns etc laid,bedded and pointed in any mortar complete all as specified and directed. |
| 28 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 29 | Demolition of brick work or stone /boulder masonry, built in CM, incl all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed. |
| 30 | M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6) complete all as specified and directed. |
| 31 | Demolition of cement concrete ( unreinforced) in ground floors and pavings n exe 15 cm thickness. ( below or above ground level) complete all as specified and directed. |
| 32 | Cement concrete type C- 2, 1:3:6 (40mm graded aggregate) 75 mm thick as in plinth protection complete all as specified and directed. |
| 33 | Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises, M&L non skid ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick in CM 1:6 complete all as specified and directed. |
| 34 | Dismantling of floor tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises. M&L Non skid ceramic white tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 35 | Dismantling of wall tiling incl cement mortar bedding (but not backing) removing servicable tiles to a store and rubbish off premises .M&L Glazed ceramic coloured tiles(match as floor tiles) of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed. |
| 36 | Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water complete all as specified and directed. |
| 37 | M&L Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 38 | M & L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed.Note :- Water proofing liquid compound shall be measured and paid separately. |
| 39 | M&L Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on new surface of wall including preparation of surfaces with complete all as specified and directed. |
| 40 | M&L Distempering with 1st quality acrylic distemper (ready mixed ) having VOC content less than 50 gm/litre of approved manufacturer of required shade and colour complete as per manufacturers specification two or more coats over 2mm wall care putty on old surface of wall including preparation of surfaces with complete all as specified and directed. |
| 41 | Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces of wall complete including preparation of surfaces of walls complete all as specified and directed. |
| 42 | Material & Labour for appplying two or more coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489 :2004, Alkali & fungal resistance dirt resistance exterior paint of required shade ( Company Depot Tinted ) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces of wall complete including preparation of surfaces of walls by complete removal of existing treatment complete all as specified and directed. |
| 43 | M&L for one coat of white wash on ceiling incl preparation of old plastered surfaces complete all as specified and directed. |
| 44 | S&F in repair stainless steel curtain rods 20 mm dia including brackets with cut hole suitable for 20 mm dia rod fixed with screws and gutties in wall, including end caps with wall ornament and fixed to curtain rod with screws of design/shape complete all as specified and directed. |
| 45 | S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495 mm X 420 mm bowl size 410mm x 330mm x 160mm complete all as specified and directed. Make Blue Star,Nirali,Paryag/Equivalent. |
| 46 | Roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments complete all as specified and directed. |
| 47 | M&L for PCC 1:2:4, type B0 using 12.5mm graded crushed stone aggregate as in roof padding complete all as specified and directed. |
| 48 | Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 using water proofing liquid compound as per manufacturer's instructions and surface finished even and smooth without using extra cement. complete all as specified and directed. |
| 49 | Applying bitumen primer for use in waterproofing and damp proofing treatments, complete all as specified and directed. |
| 50 | Bitumen hot blown VG 20 of paving grade (60-80 penetration) applied hot, two coats over primed concrete surfaces at the rate of 1.5 kg per sqm per coat. Complete all as specified and directed. |
| 51 | APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove febric (wt. not less than 150 gms/sqm) land on primed surface by forced appplication complete all as specified |
| 52 | 50 mm thick PCC M-20 (Nominal mix) using 12.5 mm graded stone aggregate mixed with water proofing compound in sunken slab complete all as specified and directed. |
| 53 | Rendering 15 mm thick plaster in CM 1:3 on fair faces of brickwork or concrete surfaces with waterproffing compound complete all as specified and directed. |
| 54 | M & L for application two coats of water proofing polymeric based chemical on concrete surfaces in sunken floor. WPC should be applied as per manufactures instruction, after application of WPC ponding complete all as specified and directed. |
| 55 | M & L for PCC 1:5:10 type E-2 (using 40 mm graded crushed stone aggregate ) in foundation , filling and mass concrete , complete all as specified and directed. |
| 56 | Taking up or down 15mm bore dia steel water tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 57 | Taking up or down 20mm bore dia steel water tubing and connection, including cleaning for refixing or removal to store, complete all as specified and directed. |
| 58 | Steel water tubing, 15mm bore dia, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed. |
| 59 | Steel water tubing, 20mm bore dia, galvanised, \\"medium grade\\" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor including cutting chases for concealed work etc, complete all as specified and directed. |
| 60 | S&F 20mm dia gun metal ,globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 61 | S&F in repair vitreous china wash down water closet pan (Orissa patern) white with integral foot rest of of size 580x440mm white (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including 'P' and 'S' trap complete incl making good to floor complete all as specified and directed. |
| 62 | Supply of PVC 10 Ltr valvless,syphonic action type , flushing cistern, low level,white inlet, ball valve, float and handle including bracket and & supply of flush pipe of polyethylene of low or high density or PVC , 32 mm dia for low level cistern device.(Note:- Fixing of these items includes in connected items) complete all as specified and directed. |
| 63 | S & F health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in pipe. complete all as specified and directed. (Make : Jaquar/Kohler/ Cera)/Equivalent. |
| 64 | S&F in repair 15mm bore Angle valves, CP fancy type (ISI marked) one way/two way screwed down, high pressure with crutch or butterfly handle, screwed both ends (externally threaded) complete all as specified and directed. |
| 65 | S&F in repair bib taps 15mm bore, fancy type cromium plated with butterfly handle, screwed down, high pressure, with carutch or butterfly handle, screwed both ends for iron pipe or for unions.including wall flange complete all as specified and directed. |
| 66 | S&F in repair Brass chromium plated mixture for mixing hot and cold water for Bath/WHB, screwed down for iron pipe for 15mm dia bore pipe, complete all as specified and directed. |
| 67 | S&F in repair CP Swan Neck type Pillar taps fancy type 15 mm bore cast alloy with capasten head screwed down high pressure with without lettered 'Hot' or Cold with long screwed shanks and fly-nutsscrewed complete all as spfd and directed |
| 68 | S&F soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed. (Make : Jaquar/Kohler/ Cera)/Equivalent. |
| 69 | Supply & Fixing 600mmx450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 70 | S&F brass cromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as specified and directed. |
| 71 | S&F in repair PVC connections 15mm, 450mm long with PTMT nuts washers etc complete all as specified and directed. |
| 72 | S&F Rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position with PVC float ball valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including dismantling old cemented/ asbestos water/ PVC storage tank, complete all as specified and directed. |
| 73 | Dismantling of CI/PVC pipe 75/100mm bore fixed to wall or laid in floor or trenches inculding connection complete all as specified and directed. |
| 74 | S&F PVC (SWR) pipes 75 mm bore dia, single socketed, in any length with rubber ring joints fixed to walls/ laid in trenches or in floors etc, complete all as specified and directed. |
| 75 | S&F PVC (SWR) pipes 110 mm bore dia, single socketed in any length with rubber ring joints fixed to walls/ laid in trenches etc complete all as specified and directed. |
| 76 | S & F 75 mm bore PVC Bends (SWR) complete all as specified and directed. |
| 77 | S & F 75 mm bore PVC (SWR) T- Junction with ovel acces door complete all as specified and directed. |
| 78 | S & F 110 mm bore PVC Bends (SWR) complete all as specified and directed. |
| 79 | S & F 110 mm bore PVC (SWR) T-Double Junction with ovel acces door complete all as specified and directed. |
| 80 | S&F CP grating 125mm. complete all as specified and directed. |
| 81 | S & F PVC (SWR) multi floor trap of 75mm dia with grating including jointing with solvent cement complete all as specified and directed. |
| 82 | S&F PVC (SWR) vent cowl 110 mm dia complete all as specified and directed. |
| 83 | Supply only liquid water proofing liquid complete all as specified and directed. |
| 84 | M&L cutting into existing manholes for connecting new drains making good to pipe and rendering cutting our existing benching for forming branch channel (1/2 round or 3/4 section) in cement concreete 1:2:4 type B-1 (using 20mm graded crush stone aggragate) smooth finished and reforming benching as reqd for 150/200mm internal dia of pipe complete all as specified and directed. |
| 85 | Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. |
| 86 | Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls,floors, etc, complete all as specified and directed. |
| 87 | Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed. |
| 88 | M&L for point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including PVC concealed conduit of suitable size incl all fittings such as Tee, connector pieces, L-junction etc on joints including terminated boxes of Modular GI sheet Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement ) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/celing PVC conduit shall be provided on surface with proper fixing clamps complete all as specified and directed. |
| 89 | Description all as per serial item No 88 here-in-before but one 5pin, 6 Amp socket outlet on same board complete all as specified and directed. |
| 90 | Description all as per serial item No 88 here-in-before but one 5pin, 6 Amp socket outlet independent complete all as specified and directed. |
| 91 | Description all as per serial item No 88 here-in-before but for one 5 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm for phase and earth wire of size complete all as specified and directed. |
| 92 | All as per the description of serial item no 88 above controlled by two 2-way switches, with cables 1.5sqmm size complete all as specified and directed. |
| 93 | S&F Modular Switch two way 6 Amp, one module 240 volts ISI marked complete all as specified and directed. |
| 94 | S&F bell, AC 230 Volts, single pole complete all as specified and directed. |
| 95 | S&F Modular bell push 6A 1 module 240 volts ISI marked complete all as specified and directed. |
| 96 | S&F Modular Switch one way 6 Amp, one module 240 volts ISI marked complete all as specified and directed. |
| 97 | S&F Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. |
| 98 | S&F Socket 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. |
| 99 | S&F Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed. |
| 100 | S&F Modular Fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed. |
| 101 | S&F Modular white cover plate 8M complete all as specified and directed. |
| 102 | S&F Modular white cover plate 6M complete all as specified and directed. |
| 103 | S&F Modular white cover plate 3M complete all as specified and directed. |
| 104 | S&F Modular white cover plate 1M complete all as specified and directed. |
| 105 | S&F Single pole and neutral enclosure with 1 two pin and earth plug and a socket complete with one single pole MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed. |
| 106 | S&F ceiling rose, 3 terminal surface type complete all as specified and directed. |
| 107 | S&F angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 108 | S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 20 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. |
| 109 | S&F Decorative ultra slim LED Tubelight fitting of LED with extruded polycarbonate, enviormental friendly energy efficient ready to use, 10 watt, 6500K fitting, incluing reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection from ceiling rose to connector of LED fitting including testing on completion all as specified and directed. |
| 110 | S&F street light bracket made out of 40mm dia GI light grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 40 x 5 iron strip and nut bolts and washers, complete all as specified. |
| 111 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 112 | M&L in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 10.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark in PVC casing capping concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note : Wiring shall be done in proper colour coding. |
| 113 | M&L distribution board sheet steel powder coated for MCB with rated bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and directed.Note:- Distribution board and MCB's should be same make. |
| 114 | S &F in replacement of SPN 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 115 | S&F in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 116 | S&F factory made CRCA sheet powder coated double door meter panel board 2mm thick, of size 100X100X20 cm or suitable size , with Aluminium bus bar, wall mounted type partially grouted in wall with locking arrangement, handle and making good disturbed surface as well as matching with existing whitewash color/surface and including provn of following and connection complete all as specified and directed :-a) MCCB 100A, 415 Volts, C series-01Nos (Incoming)b) MCB SPN, 40A, 230 Volts-05 Nos (Outgoing for each qtr and 1 common stair case light point) including connection complete all as specified and directed. |
| 117 | Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level ,connected to galvanised earth lead wire 4.0mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 40mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and complete all as specified and directed. |
| 118 | Disconnecting/ Taking down Ceiling Fan/ Exhaust fan of any sweep and deposit to safe custody and refixing the same making connection and testing complete all as specified and directed. |
| 119 | Disconnecting water heater and taking in safe custody/ refixing the same including fastner and making the conection and testing complete all as specified. |
| 120 | Disconnecting electronic meters temper proof LCD display and taking in safe custody and refixing the same with caliberation and cleaning and making the conection and testing complete all as specified and directed. |
| 121 | Supplying laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volta grade with stranded aluminium conductor of size 35 Sqmm , 3.5 core flat cable complete all as specified and directed. |
| 122 | Excavation in trenches n exc 1.5 m wide and n exc 1.5 mtr in depth for foundation laying of under ground cable erecting of pole stay not exc 10 sqm on plain and not exc 1.5 m depth and getting out in soft & loose soil complete all as specified and directed. |
| 123 | Returning, filling in (soil ) including spreading, levelling, watering and well ramming in layers not exc 25cm in any type of soil complete all as specified and directed. |
| 124 | Removal of excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed. |
| 125 | M&L for sand cushioning to under ground cable with a layer of sand 8cm before laying the cable and 15cm after laying the cable (10cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed. |
| 126 | M&L for sub class ‘B’ brick old size protection cover laid dry flat transversally along the length of cable on cushioning with width equal to the length of brick complete all as specified and directed. |
| 127 | Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail