Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BUILDINGS & STRUCTURE (Sch 'A' PART-I) |
| 2 | Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 40,02,11,700.00 inserted by the MES in Schedule ‘A’ Part-I. |
| 3 | EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II) |
| 4 | Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 30,31,191.29 inserted by the MES in Schedule ‘A’ Part-II. |
| 5 | INTERNAL WATER SUPPLY (Sch 'A' PART-III) |
| 6 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 7,07,330.16 inserted by the MES in Schedule ‘A’ Part-III. |
| 7 | INTERNAL ELECTRIFICATION (Sch 'A' PART-IV) |
| 8 | Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,13,10,758.80 inserted by the MES in Schedule ‘A’ Part-IV. |
| 9 | ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V) |
| 10 | Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,08,68,088.22 inserted by the MES in Schedule ‘A’ Part-V. |
| 11 | SEWAGE DISPOSAL (Sch 'A' PART-VI) |
| 12 | Lump sum price worked out by the Contractor for “(SEWAGE DISPOSAL)” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 16,98,733.50 inserted by the MES in Schedule ‘A’ Part-VI. |
| 13 | AREA DRAINAGE (Sch 'A' Part-VII) |
| 14 | Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,45,655.45 inserted by the MES in Schedule ‘A’ Part-VII. |
| 15 | EXTERNAL WATER SUPPLY (Sch 'A' Part-VIII) |
| 16 | Lump sum price worked out by the Contractor for “(EXTERNAL WATER SUPPLY)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.97,539.92 inserted by the MES in Schedule ‘A’ Part-VIII. |
| 17 | EXTERNAL ELECTRIFICATION (Sch 'A' PART-IX) |
| 18 | Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 92,52,627.55 inserted by the MES in Schedule ‘A’ Part-IX. |
| 19 | FIRE FIGHTING (Sch 'A' Part-X) |
| 20 | Lump sum price worked out by the Contractor for “(FIRE FIGHTING)” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 94,94,277.20 inserted by the MES in Schedule ‘A’ Part-X. |
| 21 | LIGHTNING PROTECTION (Sch 'A' Part-XI) |
| 22 | Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,46,166.30 inserted by the MES in Schedule ‘A’ Part-XI. |
| 23 | LIFT (Sch 'A' Part-XII) |
| 24 | Lump sum price worked out by the Contractor for “(LIFT)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs.99,02,655.20 inserted by the MES in Schedule ‘A’ Part-XII. |
| 25 | TV SOCKET (Sch 'A' Part-XIII) |
| 26 | Lump sum price worked out by the Contractor for “(TV SOCKET)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 13,13,338.60 inserted by the MES in Schedule ‘A’ Part-XIV. |
| 27 | COOLING APPLIANCES (AC) (Sch 'A' Part-XIV) |
| 28 | Lump sum price worked out by the Contractor for “COOLING APPLIANCES (AC)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 18,62,200.88 inserted by the MES in Schedule ‘A’ Part-XIV. |
| 29 | DEMOLITION AND DISMANTLING (Sch 'A' Part-XVIII) |
| 30 | Lump sum price worked out by the Contractor for “(DEMOLITION AND DISMANTLING)” as listed in Schedule ‘A’ Part-XVIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 10,71,212.04 inserted by the MES in Schedule ‘A’ Part-XVIII. |
| 31 | MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XVII) |
| 32 | INTERNAL ELECTRIFICATIONS & F Metal flush box 8 module complete all as specified and directed. |
| 33 | S & F Modular type TV socket Co-axial socket (RJ-9) outlet 1 Module in the modular MS/ GI sheet Box and cover plate including concealed 40mm PVC conduit in wall/ceiling/fixed to roof , connections etc complete all as specified and directed |
| 34 | S & F Modular type RJ-11 telephone socket outlet in the modular MS/GI sheet box and cover plate including concealed 25 mm PVC conduit in wall/ceiling/fixed to roof , connections etc complete all as specified and directed. |
| 35 | S & F of engagement light (LED LIGHT) of red and green colour outside the CO/OIC office. controlled separately for red and green LEDs through one way switches located outside of CO / OIC office. The engagement status of CO / OIC shall be transmitted to all concerned officers offices through LED engagement lights (red and green) colour installed inside their respective offices. The system shall be connected through 1.5 sqmm 3-core submain circuit wiring, complete all as specified and directed.NOTE : Submain wiring of 1.5 sqmm, 3-Core wire shall be measured and paid separately. |
| 36 | S & F LED hanging profile light 40 watt LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 120 lumens per watt, aluminium extruded housing powe coated, suitable for suspended mounting, complete with high efficiency polycarbonate diffuser for uniform illumination, colour temperature 6500k (neutal/cool white), including suspension kit-1200mm, driver, connectors and fixing flxible copper conductor cable, complete all as specified and as directed. |
| 37 | S&F LED light fitting 24 watt recess mounting of size 300 mm x 300 mm , LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 1200 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmm x 3 core complete all as specified and directed by EIC. |
| 38 | Materials and Labour for bracket for street light fittings, made out of 40 mm bore galvanized steel tubing, light grade, (1.60 RM Approx), bent to shape required and fixed to pole with FI clamp 40 X 5 mm with suitable size nuts, bolts and washers complete all as specified and directed. |
| 39 | S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 amps rated copper busbar, 6 way Double door (with metal) door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, IK 09, Conf to IS 8623-1&3 , IEC 61439-3, having Neutral and earth bar , cable ties for cabel management, fully shrouded neutral bar, reversible door option, blanking plate including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed by Engr-in-charge. |
| 40 | Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip 50x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 40mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by Engr-in-Charge.OTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:-1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock.2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistivity is very high.3.The cost of GI strip of size 50x 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer.5. Cost of welding and nut bolts are deemed to be included in the unit rate. |
| 41 | S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chase or buried in ground or drawn in conduit/pipe or fixed to pole or any oher indicated situation for loop earthing etc. as required for 50 x 6 mm galvanised iron strip complete all as specified and as directed. |
| 42 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (MLTP), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1975MM (H) X 2150MM (L) X 1000MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 1100Amp rated, 32kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.12 to 16.13 |
| 43 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 44 | Incoming complete all as specified and directed;(a) EDO ACB 1000Amp,50kA, rating 415 Volts ,4 pole ,Outgoing complete all as specified and directed.(a) MCCB FP 250 Amp 36 KA - 02 Nos. (b) MCCB FP 200 Amp 25 KA - 02 Nos. (c) MCCB FP 160 Amp 25 KA - 02 Nos. (d) MCCB FP 63 Amp 25 KA - 01 No. (e) Multi-functional Meter CL.1 RS 485 - 01 No(f) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (g) 1000/5A CT CL.1.0,15VA(h) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc). |
| 45 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (Utility Panel), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1825MM (H) X 1050MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 100Amp rated, 25kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.15 to 16.16 |
| 46 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 47 | Incoming complete all as specified and directed;(a) MCCB 63Amp, 415V, 50Hz, 16kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 16 Amp, 415V, 50Hz, 16kA, 4P -05 Nos(b) Multi-functional Meter CL.1 RS 485 - 01 No(c) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set.(d) 100/5A CT CL.1.0,10VA(e) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 48 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (PDB-0), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1825MM (H) X 1650MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 300Amp rated, 25kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.18 to 16.19 |
| 49 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 50 | Incoming complete all as specified and directed;(a) MCCB 200Amp, 415V, 50Hz, 25kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 20 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(b) MCCB 25 Amp, 415V, 50Hz, 16kA, 4P -01 Nos(c) MCCB 32 Amp, 415V, 50Hz, 16kA, 4P -06 Nos(d) MCB 16 Amp, 230V, 50Hz, 10kA, 4P-02 Nos(e) Multi-functional Meter CL.1 RS 485 - 01 No(f) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (g) 300/5A CT CL.1.0,10VA(h) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 51 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (PDB-1), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1975MM (H) X 1650MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 200Amp rated, 25kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.21 to 16.22 |
| 52 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No. NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 53 | Incoming complete all as specified and directed;(a) MCCB 160 Amp, 415V, 50Hz, 25kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 20 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(b) MCCB 32 Amp, 415V, 50Hz, 16kA, 4P -09 Nos(c) Multi-functional Meter CL.1 RS 485 - 01 No(d) 200/5A CT CL. 1.0, 10 VA(e) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (f) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 54 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (PDB-2), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers size 1975MM (H) X 1650MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 300Amp rated, 16kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.24 to 16.25 |
| 55 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 56 | Incoming complete all as specified and directed;(a) MCCB 200Amp, 415V, 50Hz, 25kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 32 Amp, 415V, 50Hz, 16kA, 4P -03 Nos(b) MCCB 25 Amp, 415V, 50Hz, 16kA, 4P -04 Nos(c) MCCB 20 Amp, 415V, 50Hz, 16kA, 4P -01 Nos(d) MCCB 16 Amp, 415V, 50Hz, 16kA, 4P -03 Nos(e) Multi-functional Meter CL.1 RS 485 - 01 No(f) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (g) 300/5A CT CL.1.0,10VA(h) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 57 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (PDB-3), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1975MM (H) X 1650MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 300Amp rated, 16kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.27 to 16.28 |
| 58 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 59 | Incoming complete all as specified and directed;(a) MCCB 250Amp, 415V, 50Hz, 36kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 63 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(b) MCCB 40 Amp, 415V, 50Hz, 16kA, 4P -03 Nos(c) MCCB 32 Amp, 415V, 50Hz, 16kA, 4P -01 Nos(d) MCCB 25 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(e) MCCB 16 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(e) Multi-functional Meter CL.1 RS 485 - 01 No(f) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (g) 300/5A CT CL.1.0,10VA(h) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 60 | Supply, fixing and commissioning and Design verified as per IS /IEC-61439-1&2 LT Panel (PDB-4), indoor type LT Panel Box by CPRI tested and IEC-61439 certified manufacturers of size 1575MM (H) X 1650MM (L) X 400MM (D) with comprising of the following and complete all as specified and directed.Fabrication Details :Main frame 2 mm thick CRCA sheet, partition sheets / covers / doors of 1.5 mm thick CRCA sheet, gland plates 1.5 mm thick MS sheet (undrilled), base frame of 75 mm MS channel with provision of incoming and outgoing cable entry at the bottom for installation, seperate chambers for Main Bus Bars, switch Gears and Cable end connections free standing floor mounted with degree of protection IP 54 and with heavy duty Hinges for doors and locking arrangements with Aldrops at front and Back complete all as specified and directed. Bus bar details :Material shall be Copper bus bar 300Amp rated, 16kA, 3L+N, sleeving heat shrinkable type, with bus bar sizes for phase of rated capacity and bus bar shall extended type be support of epoxy type insulators for connection ,earthing of 40x6 mm GI Flat complete all as specified and directed. Item Continued as 16.30 to 16.31 |
| 61 | Painting Detais :Painting shall be 7 tank processed powder coated/ epoxy coated shall be a dry finishing process that uses finely ground particles of pigment and resin based polymer that are electrostatically charged and sprayed onto electrically grounded parts complete all as specified and directed.Wiring :Pannel wiring shall be of 2.5 sq mm copper standard with 5A MCB wiring for controll wiring and indication lamps complete all as specified and directed.Accessories for Panel Box :Multi Functional Meters CT/PT programmable with RS 485 communicatio port CL1 with direct acess to basic power and Energy parameters and Indication Lamps (LED) - 03 No.NOTE : Rate quoted includes for necessary PCC foundation / steel angulars/ channels to LT pannel and includes the cost of all Accessories and switch gears, necessary cable connections with Lugs, washers nut bolts and cable glands as per site requirement complete all as specified and directed. |
| 62 | Incoming complete all as specified and directed;(a) MCCB 160Amp, 415V, 50Hz, 25kA, 4P-01 NoOutgoing complete all as specified and directed.(a) MCCB 32 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(b) MCCB 25 Amp, 415V, 50Hz, 16kA, 4P -02 Nos(c) MCCB 20 Amp, 415V, 50Hz, 16kA, 4P -01 Nos(d) MCCB 16 Amp, 415V, 50Hz, 16kA, 4P -01 Nos(e) MCB 20 Amp, 230V, 50Hz, 10kA, 'C' Series, 2P -01 No(f) MCB 32 Amp, 230V, 50Hz, 10kA, 'C' Series, 2P -01 No(g) Multi-functional Meter CL.1 RS 485 - 01 No (h) Indicator lamps (R, Y. B) with individual fuse protection – 01 Set. (j) 300/5A CT CL.1.0,10VA(k) Misc electrial assessories (wires, sockets, terminals, channels, nuts & Bolts etc) |
| 63 | S&F round shape 6 Watts, 220 Volts, sensor based, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 64 | S&F round shape 12Watts, 220 Volts, sensor based, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 65 | ROAD/ PATH/ CULVERT/ HARDSTANDINGM & L for applying tack coat on existing bituminous, cement concrete or primed granular surface to ensure a bond between the surface being paved and the overlaying course with cationic bitumen emulsion RS-1 grade at the rate of 3 kg per 10 sqm of surface com |
| 66 | Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi-automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T & P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete all as specified |
| 67 | Supply & Fix delinator of ABS round body fitted with 2 Nos 100mm dia highly relective reflectors made out of PMMA and mounted on MS pipe of 50mm dia duly powder coated, and rust and anti theft steel net colour of red, white or yellow-white combination as available, provided at site as per manufacture's instruction embedded in PCC (1:3:6) type C2 in ground 30cm X 30cm X 30cm block including exacavation of hole and removing excavated material from site complete all as specified and directed. |
| 68 | Supply & Fix for solar powered rechargable battery road stud with super bright LED flash both side reflection Red/Yellow unbreakable, scratch resistant for maintenance free operation etc. complete all as specified and directed. |
| 69 | Supply & Fix for CAT EYE both side reflection colour yellow etc. complete all as specified and directed. |
| 70 | SEWAGE DISPOSALM&L for construction of RCC Septic tank (150 Users) conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:3:6 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as specified and shown on Drg No. CESZ/2020/TD/ST-08 Sheet 1/3 & 3/3. |
| 71 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of DWC complete filled with brick bats of size not less than 3M dia x 4.5 M effective depth complete all as specified and shown on Drg No. SZ/TD-14 Sheet 1/1. |
| 72 | DG SETSupply, installation, testing and commissioning of silent built-in within an acoustic enclosure diesel engine driven generating set water cooled including AMF panel for standby power supply 415 Volts, 03-Phase, 4-Wire, 50 Cycles/Sec, 320 KVA (256.00 KW) or next higher standard size available at 0.8 power factor complete as per CPCB-IV norms with alternator directly coupled to diesel engine, mounted on common base frame and complete with self-starter, fuel tank capacity not less than 8 hours fuel requirement and battery as recommended by OEM, battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. and microprocessor based gen-set controller with the following under-mentioned features and all as specified and as directed.(a) Alphanumeric LDC display with LED backlight.(b) Operator interface.(c) Suitable to provide a record of most recent fault conditions and fault history.(d) Complete alternator data, viz. voltage, Ph-Ph, Ph-neutral, KVA, Frequency etc.(e) Complete engine data viz. starting battery voltage, engine temperature, engine running hours, engine oil pressure etc.(f) Control including provision of service adjustment and calibration of DG control functions. Item Continued as 16.40 to 16.42 |
| 73 | GENSET SPECIFICATIONS :-Prime Mover Rating : 380 BHPCurrent Rating : 445.20 ANo. of Phases : 03Power Factor : 0.8 (Lag)ENGINE SPECIFICATIONS :-Aspiration : Turbocharged-aftercooled.No. of Cylinders : 06, In line.RPM : 1500Governor : MechanicalALTERNATOR SPECIFICATIONS :-Voltage : 415RPM / Frequency : 1500/50 HzEnclosure : IP 23Voltage Regulation (Max) : +/- 1%.Insulation Class : H ClassConformance Standards :-IS 4722, BS 5000, IS 1460, ISO 8528, BS 5514, ISO 3046.Make and Size of Battery : As recommended by OEM. |
| 74 | AMF PANEL SPECIFICATIONS :-ASEB I/C : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.DG I/C : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.AMF O/G : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/ Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.The size / rating of all the connected accessories viz. Contactors, relays, timers, bus-bars, connecting cables etc. of the AMF Panel shall be in conformity with the I/C and O/G ACBs/MCCBs. Please Enable Macros to View BoQ information |
| 75 | AMF PANEL SPECIFICATIONS :-ASEB I/C : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.DG I/C : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.AMF O/G : Air Circuit Breaker (ACB), 4-Pole having breaking capacity 50 KA of rating 630 A, manual draw-out (MDO) type with LSING Protection, LCD Display, Communication through RS-485 Port, True RMS Sensing, Current/Voltage/ Power Measurement, Thermal Memory, Fault Indication, Zone Selectivity, Harmonics etc. – 01 No.The size / rating of all the connected accessories viz. Contactors, relays, timers, bus-bars, connecting cables etc. of the AMF Panel shall be in conformity with the I/C and O/G ACBs/MCCBs. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy