| 1 | M&L for dismantling of Asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified and directed. |
| 2 | Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed. |
| 3 | Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed. |
| 4 | Taking down cement plaster on stone masonry, RCC surfaces,ceiling, dado surfaces etc complete incl racking out joints, hacking for key scrubbing down with water complete all as specified and directed. |
| 5 | M&L for demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided all as specified and directed. |
| 6 | M&L for Reinforced cement concrete (Nominal Mix) type B1 1:2:4 using 20 mm graded stone aggr as in Beams, cantilevers , bressummers, lintel over 1.5 m span including necessary formwork etc. all as specified and directed. |
| 7 | S&F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 8 | S&F mild steel TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed. |
| 9 | M&L for 30 mm thick guniting in patches on to the required area on RCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at any heights from existing ground floor and at any locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete as specified here in before and applying one coat of rust convertor/kp-100 equivalent grade over reinforcement wherever necessary providing and tying in position 25mmx25mmx12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc,loose spalt concrete portions by chipping, removal of dust over treated surface and applying 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, and removing the debris out side the MOD land in low lying areas and leveling complete all as specified & as directed. |
| 10 | M&L Prepainted Galvalume Aluminium Zinc Coating GI based corrugated Steel Sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 11 | M&L for Plain, galvanised, mild steel sheeting, 0.63mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275, fixed with self tapping screws all as specified and as directed. |
| 12 | Mild steel sheet eaves gutters, galvanised class 3, half round with rounded edges 1.25 mm thick 150mm dia sheet complete all as specified and directed. |
| 13 | M&L for squarred rubble walling Jodhpur type regular coursed well bonded, bedded and solidly hearted built in cement mortar 1:4 complete all as specified and directed. |
| 14 | All as per item no 13 specified above but except stone complete all as specified and directed. |
| 15 | Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing complete all as specified and directed. |
| 16 | M&L for providing of Pavement quality concrete(PQC) of minimum 28 days field Flexural strength of 45Kg/ Sqcm or 4.5 Mpa, aggregate gradation as per Table 3 of IRC 15 2017, coarse aggregate of clean , hard strong, dense non-porous and durable pieces of crushed stone ogravel, fine aggregates of clean natural sand ocrushed stone sand or combination of both using minimum 360 kg/cum of cement with non-circular virgin synthetic fibre of 12-18 mm length, specific gravity 1.34 to 1.39, UV stable, alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240°C and minimum tensile strength of 300 Mpa and at the rate as specified by the manufacturer. PQC laid, spread and compacted with slip-form paver of minimum 7.50 m width , including curing and tining by Texturing cum Curing Machine complete all as specified and directed. Required surface texturing to be done as specified in Clause - 10.1.14 and Table g of IRC 15-2017 |
| 17 | Rendering 15 mm thick on fair faces of stone masonry surface or concrete surfaces of CM 1:6 be finished even and smooth (without using extra lime or cement complete all as specified and directed. |
| 18 | M&L Rendering 10 mm thick in CM (1:4) mixed with water proofing compound on stone wall, concrete surfaces on ceiling / facia /RCC Chhaja, column etc all as directed & finished even & smooth complete all as specified and directed. |
| 19 | Raking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar all as specified |
| 20 | M&L keyed pointing in cement mortar (1:4) to squared rubble masonry regular coursed or un coursed complete all as specified & directed. |
| 21 | M&L for Dismantling of cast iron/pvc soil waste & vent pipes 110 mm dia incl all fittings etc complete all as specified and directed. |
| 22 | Supplying and laying of 110 mm dia CPVC pipes SWR fittings on walls / ceiling or laying in floors complete all as specified. (with all fitting) |
| 23 | S&F 110 mm bore UPVC bends any radius with oval acess door complete all as specified and directed. |
| 24 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 25 | M&L for mild steel frame work in trusses purlins, posts etc complete using MS angle iron, MS Hollow Square or rectangular sections,flat irons etc complete incl necessary welding cutting to shape & hoisted & fixed in position complete all as directed & specified . |
| 26 | M&L for preparation of new steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including M&L a coat of red- oxide, zinc chrome primer complete all as specified and directed. |
| 27 | M&L for preparation of old painted steel surface of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over & including M&L a coat of red- oxide, zinc chrome primer complete all as specified and directed. |
| 28 | M&L for three coats of white wash including preparation of new surfaces on wall, all as specified and as directed. |
| 29 | M/L for preparation of old plastered/ unplastered surfaces of walls and applying two coats of white wash all as directed by Engr -in- charge. |
| 30 | Complete removal of existing treatment of any description on walls and applying with 2mm wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper over & including M&L single coat of primer on walls complete all as specified and as directed. |
| 31 | M/L for two coat of cement based paint on old/new plastered/ unplastered surfaces over one coat of white wash on wall & including preparation complete all as specified and directed. |
| 32 | S&F GI chicken wire mesh of 0.71 mm dia wire & 12 mm mesh size fixed with nails & screws around RCC chajjas/fascias etc,complete all as specified and as directed. |
| 33 | M&L 50 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate laid in alternative bays as in plinth protection including finishing the surface even & fair & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight in 2 mtr interval, complete all as specified and directed.. |
| 34 | Supply only integral water proofing comound complete all as specified and directed. |
| 35 | S&F of box type steel ventilator with top hung shutter including shop coat zinc chromate & hinges with steel handle, and steel peg stay, complete with glazing bars, complete all as specified and directed. |
| 36 | S&F Sheet glass 4mm thick, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq.m in each pane complete all as specified and directed. |
| 37 | M&L for 7.5cms thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:3 or cement mortar 1:4, complete all as specified and directed. |
| 38 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 39 | Point wiring (Concealed) in wall and surface on roof, garder, pipe and piller using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories ISI marked with valid CML No. ( IS 9537 -1983 for wall/roof /floor etc with pressed flush metal boxes covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continully conductor to commonearth and connecting to earrth dolly complete all as specified and directed for the follwing :- (a) One light point controlled by one, one way switch. |
| 40 | All as per Sr. item No. 39.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the independent board controlled by one no 5 Amp switch. |
| 41 | All as per Sr. item No. 39.00 here-in-above, but suitable for One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch. |
| 42 | All as per srl item no.39.00 here-in-before but with 2.5 sq mm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for indpendent 15 Amp point. |
| 43 | S&F Modular switch flush type single pole one way 6 Amp ISI Marked,1 module, complete all as specified and directed. |
| 44 | S&F Modular switch flush type single pole one way 16 Amp ISI Marked,1 module, complete all as specified and directed. |
| 45 | S&F Modular socket outlet 2 in 1, 5 pin, 6 amp flush type, 230 Volts ISI Marked, complete all as specified and directed. |
| 46 | S&F Modular socket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked, complete all as specified and directed. |
| 47 | Supply and fix modular socketed stepped type electonic fan regulator flush type ISI Marked |
| 48 | Supply and fixing replacement LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including,copper conductor cable of suitable size from ceiling rose complete complete, 4 ft long all as specified and directed. |
| 49 | S&F in replacement bldg security LED Light Luminaire of 35 Watts having IP 65 protection fiting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protectore, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as specified and directed. |
| 50 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 51 | S&F sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door DB's suitable for provn for a MCB One TPN 63 Amps as incoming and complete all as specified and directed by Engr-in-charge. Note : MCB/RCCB TPN/SPN/SP measured and paid saperatly. |
| 52 | Supply and fixing MCB TPN B Curve, 63 Amps, 415 Volts complete all as specified and directed. |
| 53 | S&F MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed. |
| 54 | S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed. |
| 55 | Supply and fixing as MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall incl dismantling of old UNSV DB complete all as specified and directed. |
| 56 | M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and incl 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 25 mm dia size incl all conduit accessories & fittings / junction boxes / inspection covers etc, with and incl cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed.Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable incuding one run of conduit pipe will be measured as one length including making good the disturbed surfaces. |
| 57 | M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 58 | Supply, laying testing LT UG XLPE in trenches/saddle clamping on wall (as per site requirement insulated,armoured, heavy duty electric cable, aluminium coductor, 1100 V grade,croos sectional area 16 sqmm 4 core all as diredted by Engr - in - charge. Note : Earth work and brick work measured and paid separately |
| 59 | Excvation in trenches not more than 1.5 meter wide and in depth in hard/dense/loose soil all as directed by Engr in Charge |
| 60 | Returning and filling of excvated hard/dense/loose soil in treches aall as directed by Engr - in Charge |
| 61 | Removal of surplus hard/dense/loose soil from excavated place and deposting at safe side distance not more than 50 meter from excavated place all as directed |
| 62 | Supply and lay sand for sand cushioning for cable protection in trenches all as directed and specified in SSR Part - 1.Note:. for the purpose of payment punned thickness will be measured etc, complete all as specified and directed. . |
| 63 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 2, flat, size 300x180mm x40 mm, complete all as specified and as directed. |
| 64 | Supply and fix GI tubing medium grade of 40 mm dia for cable protection etc, complete all as specified and directed. |
| 65 | NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of \\"Credit\\" from the Total quoted amount Please Enable Macros to View BoQ information |