| 1 | Providing and fixing factory made UPVC door frame made of UPVC extruded, section having an overall dimension, asbelow (tolerance +/- 1mm) with wall thickness 2.0mm+/- 02mm. corners of the door frame to be jointed withgalvanized brackets and stainless screws, joint mitred and plastic wilded. The hinge side vertical of the framesreinforced by galvanized MS tube of size 19 × 19 mm and 1 mm +/- 0.1 mm wall thickness and 3 nos stainless steelhinges fixed to the frame complete as per manufacturers specification and direction of Engineer-In-Chargei) Extruded section Profile size 48x40 mm. |
| 2 | Providing and fixing to existing door frames30mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a UPVC profile sectionof size 30mm x 60mm and wall thickness 2mm ± 0.2mm with inbuilt decorative moulding edging on one side. Thestyles and rails with plastic brackets of size 75×220 mm mitred and welded at the corners. The styles of the shutterreinforced by inserting galvanised MS tube of size 25×20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail madeup of \\"H\\" Section, a UPVC profile section of size 30×100 mm and 2 mm ± 0.2 mm wall thickness welded to theshutter style with a UPVC profile section single panel of size not less than 620 mm, having overall thickness of 20mm and 1 mm ± 0.1 mm wall thickness with 20 mm panel beading of suitable size/Glass (4 mm thick plain glass)/louver section, louver frame of suitable size, complete as per manufacturer's specification and direction of EngineerIn-Charge. (for W.C. and Bathroom door shutter). |
| 3 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with waterabsorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement and matching pigments etc. all complete as per direction of the Engineer-in-charge. |
| 4 | Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory,Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge.(i) Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles - 30 |
| 5 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position :Local Teak Wood |
| 6 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grainsor cross bands and face veneers on both faces of shuttersi) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 7 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.i) Fixed to openings /wooden frames with rawl plugsscrews etc. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level |
| 9 | I) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burntbrick aggregate 40 mm nominal size) |
| 10 | II) 1:4:8 ( 1 Cement: 4 fine sand : 8 graded well burnt brick aggregate 40 mm nominal size) |
| 11 | First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:-I) In cement mortar 1:4 ( 1 cement : 4 fine sand ) |
| 12 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:-I) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 13 | Neat cement punning. |
| 14 | 12 mm cement plaster of mixi)In cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 15 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of TestCertificate issued by the Manufacturer] :New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 16 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 17 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or repointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge.Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re-plastering or repointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in-charge. |
| 18 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved 450mm long towel rail with total length of 495mm, 78mm wide andeffective height quality and colour.a) 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not lessthan 190gms. |
| 19 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 1st class bricks incement mortar 1:4 (1 cement : 4 fine sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, totalweight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C.top slab with 1:2:4 mix (1 cement :2 fine sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick withcement mortar 1:3 (1 cement: 3 fine sand) finished smooth with a floating coat of neat cement on walls and bedconcrete etc. complete as per standard design :i) Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : |
| 20 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not less than 106 gms. |
| 21 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.i) Flexible pipe - |
| 22 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mmthick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 23 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 i)15 mm nominal bore |
| 24 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.i)15 mm nominal bore. |
| 25 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighingnot less than 690 gms.i)15mm nominal bore. |
| 26 | Providing and fixing brass fullway with wheel valve of approved quality.a) 40mm nominal bore (TSR-02) |
| 27 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, includingcutting and threading the pipe etc. complete :i)25 to 40 mm nominal bore |
| 28 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level |
| 29 | a) 15 mm dia. nominal bore |
| 30 | b) 20 mm dia. nominal bore |
| 31 | c) 25 mm dia. nominal bore |
| 32 | d) 40 mm dia. nominal bore |
| 33 | Providing and fixing aluminium work for doors, windows, ventilators, Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) :-A. For fixed portion of approved quality:-i) Anodised aluminium (anodised transparent or dyedto required shade according to IS: 1868, Minimumanodic coating of grade AC 15) |
| 34 | (B) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provisionfor fixing fittings wherever required including the cost of EPDM rubber / neoprene gasket required ( Fittings shall bepaid for separately ):-(i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodiccoating of grade AC 15). |
| 35 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg/cm2) conformingto IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermalexpansion etc. complete as per direction of Engineer-incharge : |
| 36 | i)Single socketed pipe - 75 mm OD |
| 37 | ii)Single socketed pipe - 110 mm OD |
| 38 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVCrain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382leaving 10 mm gap for thermal expansion: |
| 39 | i) Coupler - 75 mm |
| 40 | ii) Coupler - 110mm |
| 41 | iii) Single equal tee with door - 75x75x75mm |
| 42 | iv) Single equal tee with door |
| 43 | v) Bend 87.5° - 75 mm |
| 44 | vi) Bend 87.5° - 110 mm |
| 45 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with waterproofing cement compound, as directed by Engineer-in- Charge and consisting of applying :(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofingcement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofingcement compound @ 0.670 kg/sqm and fine sand @ 1.289 kg/sqm. This will be allowed to air cure for 4hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall andtucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 46 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with :Cement concrete 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size) Please Enable Macros to View BoQ information |