| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.-All kinds of soil |
| 2 | Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcementAll work upto plinth level:1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 7 | Half brick masonry work with first class bricks in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 8 | Demolishing cement concrete manually / by mechanical means including disposal of material with all lifts and upto 50 m lead etc. complete as per direction of the Engineer- in-charge:-Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 9 | Demolishing/Dismantling of one bathroom having broken/disfuntional Vitreous china Indian/orissa type w.c. pan/Anglo Indian W.C./European type W.C. pan externally & internally having Nominal concrete of any grade to RCC of any grade, tiles of any thickness work in floors and roofs laid in cement mortar, old plaster of any thickness or pointing, raking out joints, cleaning and preparing the surface for re-plastering or re-pointing manually / by mechanical means, C.I./PVC pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks, removing & cleaning blockage from existing pipes including disposal of unserviceable material with all lifts and any lead etc. complete as per direction of the Engineer- in-charge. |
| 10 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 11 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 12 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 MM |
| 13 | Dismantling old plaster or pointing, raking out joints, cleaning and preparing the surface for re- plastering or re-pointing including disposal of rubbish to the dumping ground with all leads and lifts etc.complete as per direction of the Engineer- in- charge. |
| 14 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veeners on both faces of shutters.30 mm thick including ISI marked Stainless Steel butthinges with necessary screws. |
| 15 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 16 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-incharge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 17 | Providing and fixing IS : 3564 marked aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 18 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :250x10 mm |
| 19 | Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc.250 x 16 mm |
| 20 | Providing and fixing aluminium tubular handle bar of 32 mm outer dia, 3.0 mm thick and 2100 mm long with Stainless Steel screws etc. of approved quality complete as per direction of Engineer-in-charge: Polyester powder coated aluminium minimum thickness 50 micron. |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators, stair railing including hand rail and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling to be paid for separately) :-For fixed portion of approved quality:-Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 22 | For shutters/ sliding shutters of doors, windows & ventilators including providing and fixing hinges / pivots / rollers and making provision for fixing fittings wherever required including the cost of PVC / neoprene gasket required of approved quality ( Fittings shall be paid for separately ):-i)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 23 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition frames with PVC / neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge :-With glass/ float glass panes of 4.0 m thickness ( weight not less than 10.0 kg / sqm ) |
| 24 | Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade-I, type II conforming to IS : 12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows, shutters and partition frames with C.P. brass / stainless steel screws all complete as per architectural drawing and the direction of Engineer-in-charge :-Prelaminated particle board of approved quality with decorative lamination on one side and balancing lamination on other side. |
| 25 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS : 1868 with minimum anodic coating of Grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge (only weight of grill to be measured for payment). |
| 26 | Aluminium Composite Panels of 3mm total thickness with Top coil – 0.25mm AA3003 Grade manufactured as per IS-737 1986, FR Grade Class B1 with 2.50mm Mineral Core with minimum 70-72% Inorganic content(Aluminium Hydroxide and Magnesium Hydroxide) 28- 30% Organic content (LDPE) conforming to ASTM E-119- 16,18 and EN 13501 - 1 class B1 and Bottom coil –0.50mm AA3003 Grade manufactured as per IS-737 1986 with minimum 25 microns lead free PVDF Coating conforming to AAMA2605 on top coil and Service coating on Back Coil (4 - 6 microns) having minimum panel weight of 5.25 Kg/m2 |
| 27 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embrossed on the body / plate with double spring mechanism and door weight upto 125 kg. for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc. complete as per direction of the Engineer-in-charge: With stainless steel cover plate minimum 1.25 mm thickness |
| 28 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622 - 2017, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 fine sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete as per direction of Engineer-in-chargeDouble charged Stainfree vitrified tiles (Glossy) Size of tile 600x600 mm |
| 29 | Providing and fixing 1st quality ceramic glazed wall tiles (minimum 200 x 300) conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-in-charge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc all complete. as per direction of Engineer-in-charge450 mm x 300 mm in all shades & desgin 1st Class Quality |
| 30 | Providing and laying ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 - 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete. as per direction of Engineer-in-chargeAnti-Skid Tiles/Mat finish Tiles/Glossy TilesCeramic Tiles 1st quality 300 x 300mm in all shades and designs |
| 31 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion:Single socketed pipe - 75 mm OD |
| 32 | Single socketed pipe - 110 mm OD |
| 33 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: |
| 34 | A) Coupler |
| 35 | i) 75 mm |
| 36 | ii) 110 mm |
| 37 | B) Single equal tee without door |
| 38 | i) 75x75x75mm |
| 39 | ii) 110x110x110mm |
| 40 | B) Single equal tee with door |
| 41 | i) 75x75x75mm |
| 42 | ii) 110x110x110mm |
| 43 | Bend 87.5° |
| 44 | i) 110mm |
| 45 | ii) 75mm |
| 46 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete.i) 75mm |
| 47 | ii) 110mm |
| 48 | Providing and fixing white vitreous china water closet squatting pan (Indian type) Orissa pattern W.C. pan of size 580x440 mm |
| 49 | Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. |
| 50 | Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings:Flat back wash basin of size 630x450mm. |
| 51 | Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittingsSize 450x300x150 mm. |
| 52 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia |
| 53 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity-white |
| 54 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357mm |
| 55 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore |
| 56 | Providing and fixing uplasticised PVC connection pipe with brass unions :30 cm length15 mm nominal bore |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on walli) 25 mm nominal outer dia .Pipes |
| 58 | ii) 40 mm nominal outer dia .Pipes |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete asper direction of Engineer in Charge.External worki) 25 mm nominal outer dia .Pipes |
| 60 | ii) 40 mm nominal outer dia .Pipes |
| 61 | Providing and fixing PTMT bib cock of approved quality and colour.15mm nominal bore, 90 mm long, weighing not less than 93 gms. |
| 62 | Providing and fixing PTMT pillar cock of approved quality and colour15mm nominal bore, 125mm long foam flow, Weighing not less than 120 gms. |
| 63 | Providing and fixing PTMT grating of approved quality and colour.Circular type.125 mm nominal dia with 25 mm waste hole |
| 64 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.Fixed to openings /wooden frames with rawl plugs screws etc. |
| 65 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture, of required shade and colour complete, as per manufacurer's specification. [Payment shall be made after submission of Test Certificate issued by the Manufacturer]Two or more coats on new work. |
| 66 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 67 | 15 mm cement plaster of mixIn cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 68 | 12 mm cement plaster of mixIn cement mortar 1 : 4 ( 1 cement : 4 fine sand ) |
| 69 | Providing 10mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level over first class wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame etc. complete as per direction of Engineer-in-charge. (frame work to be paid separately) :i) Flat surfaces |
| 70 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work |
| 71 | Painting with synthetic enamel paint ( one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 72 | Distempering with 1st quality washable acrylic distemper of approved brand and manufacture and of required shade on old work ( one or more coats ), to give an even shade as required complete as per direction of the Engineer in charge. |
| 73 | Wall painting with acrylic exterior paint (one or more coats ) of required colour of approved brand and manufacture on old work to give an even shade including preparation of surface as required complete as per direction of the Engineer in charge. |
| 74 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] : New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Please Enable Macros to View BoQ information |