| 1 | Details of Supply (A) |
| 2 | PG clamp made of Aluminum Alloy fitted with 04 Nos. suitable size of GI Nut & Bolts with washer suitable for Moose to Moose conductor. |
| 3 | PG clamp made of Aluminum Alloy fitted with 04 Nos. suitable size of GI Nut & Bolts with washer suitable for Moose to Panther conductor. |
| 4 | PG clamp made of Aluminum Alloy fitted with 04 Nos. suitable size of GI Nut & Bolts with washer suitable for Panther to Panther conductor. |
| 5 | 33KV CT Junction Box |
| 6 | 36KV Terminal kit for 1C*630 SQMM XLPE copper conductor power cable for all three phases |
| 7 | Fire Fighting CO2 Type of 22.5 KG |
| 8 | Portable AFF mechanical foam type.fire extiguisher complete with initial charge hose pipe and all other accessories and fitting as per latest IS, Trolly mounted 45/50 Ltr. capacity |
| 9 | Supply of flexible copper bond (rope type) of size 450mm long, 16mm dia & both side copper lugs heaving hole of 16mm dia and complete with nut-bolt & washer. |
| 10 | Supply of laminated strip type copper bond of size 700mm long, 16mm dia & both side copper lugs heaving hole of 18mm dia and complete with nut-bolt & washer for using in transformer neutral bushing to earth. |
| 11 | 40mm MS Rod for main earth mat |
| 12 | HDG Nut Bolt & washer size of 16*40 |
| 13 | HDG Nut Bolt & washer size of 16*45 |
| 14 | 75*10mm MS Flat (TATA JINDAL SAIL ONLY) |
| 15 | 50*6mm MS Flat (TATA JINDAL SAIL ONLY) |
| 16 | 25*6mm MS Flat (TATA JINDAL SAIL ONLY) |
| 17 | Industrial Split AC (2 ton) along with stabilizer(5KVA) , also with stand for outdoor system. (Make Blue Star/O General/Mitsubishi). |
| 18 | Cable tray 75mm |
| 19 | Cable tray 225/250mm |
| 20 | Supply of Bajaj/Philips/CGL make 150 Watt Edge LED street light. |
| 21 | Details of Work (B) |
| 22 | Safely shifting of 40 MVA T/F main tank from unloading place to existing T/F plinth by dragging about 20 Mtrs. Job includes turning of T/F if required, handling & shifting of all accessories of 40 MVA T/F such as radiator, conservator tank, bushing, cooling fan, marshling box, motor drive mechanism of RTCC panel, oil pipe line,t/f oil drum & all associated materials from store / unloading place to erection site as per requirement upto completion of job satisfactorily. |
| 23 | Additional shifting 40Mtr. @ 5mtr/ job |
| 24 | Complete erection of 40 MVA T/F by erection of radiator, conserator tank, all bushing, with their turrets connecting oil pipe lines, cooling fans,, motordrive mechaism of tap changer, RTCC panels etc. to complete the job satisfactorily including topping up of transformer oil in tank, radiators, oil pipe lines, conservator tank etc. and all other associated works for completion of work satisfactorily. All arrangement of T&P and man power will be provided by contractor at his own cost. |
| 25 | Centrifuging of complete T/F oil in T/F by connecting centrifuging pipes circulating the T/F oil through centrifuging machine and taking the BDV , PPM value of the oil periodically (Every hour) till the required value is achieved as per direction of supervising engineer. The work includes all the work related to centrifuging the oil and filling oil in T/F tank. (Operator, centrifuging machine and testing equipment shall be arrange by the Contactor). |
| 26 | Prepairing cable schedule and Dressing, binding and Termination of cable including fixing of cable tray support structure and termination of cable marking and its ferruling as per schedule and inter connection with T/F to C&R panel, RTCC panel, cooling fans ,marshaling box, driving mechanism etc and as per site requirement for completion of job satisfactorily. |
| 27 | Safely carriage of oil tank for above work from 132 KV S/S Naini Complex or Other S/S to 132 KV S/S Meja Road including loading, unloading & shifting at working place also to and fro distance approx. 2x40=80 km. |
| 28 | Making of delta earthing of transformer neutral bushing by 3 meter, 40/36mm MS Round & 75x10mm MS Flat including cutting, bending & proper welding & connect with HV, LV Neutral Bushing with double MS Flat 75x10mm as per drawing. The job also includes excavation of soil for connecting main earth mat (X & Y) co-ordinates with delta earthing & leveling of soil after completion of work. |
| 29 | Earthing of T/F body, MB, DM box of OLTC, RTCC at two points using 75x10/50x6mm M.S. flat (M.S Flat shall be provided by the department) The job also includes Excavation of soil for connecting main Earth mat (X and Y) and levelling of soil after completion of work. |
| 30 | Painting of various MS Flat by one coat red oxide primer and two coat bus green paint of Nerolac/Burger/Asian make including painting of joints below ground by best quality of non corrosive paint. |
| 31 | Testing of newly erected 40 MVA T/F oil by arranging appropriate equipments. Job includes BDV, PPM, DGA, TAN DELTA resistivity and all assocaited testing as per instruction. |
| 32 | Supply, Installation, commissioning and testing of complete set of Chemical Earthing to be done for 40 MVA T/F-II at 132 KV S/S Meja Road under ETD-III, Prayagraj including excavation, making of earth pit, fixing of electrode with back fill earthing compound, fixing of earth pit cover, any other civil work as per the site engineer and as per drawing attached (all consumable items provided by contractor at his own cost). |
| 33 | Details of Work (C) |
| 34 | Following works are required for complete erection of 132 KV& 33KV Transformer bay at 132 KV S/S Meja Road under Electy. Trans. Division-III, Prayagraj. |
| 35 | Shorting, counting and shifting of galvanized structure to loading point and loading it on vehicle at EFU-Naini, Prayagraj. |
| 36 | Carriage of above 5.28 MT structure from EFU Naini, Prayagraj to 132 KV S/S Meja Road approx. distance 40 km. (vehicle, man, materials provided by contractor at his own cost) |
| 37 | Unloading, shorting, counting member wise and stacking properly galv. structure at the store of 132 KV S/S Meja Road |
| 38 | Erection of auxiliary structure for installation of 132KV & 33KV BSI, LSI, PT, CT, LA and all associated structures for 132/33KV 40 MVA T/F bay, including shifting of all material i.e. structure part ,nuts, bolt ,washers etc from substation store to erection site. Matching of holes,matching of member if required shall be done by contractor. |
| 39 | Loading & Carriage of MS round Bar 36/40mm , 500MTR from following substations - (A) 400 KV S/S masauli to 132 KV S/S Meja Road approx. Dist. (30 km) - 300 meter.(B) 132 KV S/S Shankargarh to 132 KV S/S Meja Road approx. Dist. (90 Km.) - 96 meter. (Total weight of MS round Bar 3.168 M.T. and total distance of carriage 120 K.M. Approx) (Calculation of shifting of MS Rounbar = 3.168 x 120 = 380.16 is treated as Total Qty. 380.16 |
| 40 | Unloading of MS round Bar 36/40mm , 500MTR at 132KV Meja Road approx. |
| 41 | Laying of 36/40mm MS round bar,800mm below ground level in soil including excavation of trech, cutting,welding/painting, its back filling and all other associated work for 132/33 kv Transformer bay at 132kv s/s meja road. MS round bar will be provided by department. |
| 42 | Fabrication of 4mtr long electrode of 36/40mm dia MS round bar having 150mm long conical shape and fixing vertically below the earthmat level and its weildingwith main earth mat and its painting. |
| 43 | Shifting of material from store to erection place in switchyard of following equipments-132 KV & 33 KV( CB, LA, CT, PI, BSI and all associated material ) as per requirements. |
| 44 | Erection of following equipments as per instruction of JE/SDO manual/hydra of various equipments including shifting from store to erection site including all other associated work to complete the job satisfactorily:- |
| 45 | 132 KV Bus isolator |
| 46 | 132 KV SF-6 circuit breaker |
| 47 | 132 KV C.T |
| 48 | 132 KV C.T junction box |
| 49 | 33 KV Bus isolator with junction box |
| 50 | 33 KV CT |
| 51 | 33 KV CT junction box |
| 52 | 33KV Vacuum circuit breaker |
| 53 | 120 KV LA |
| 54 | 30 KV LA |
| 55 | Splitting of main bus and Jumpering of equipments, 132 KV & 33 KV BSI, CB, CT, LA and also jumpering to Main Bus as required with the help of Panther/moose conductor and suitable clamps/connectors including, cutting, bending, shaping etc. of the Conductor as per Site Requirement. Connector & other hardware fitting provided by department. |
| 56 | Earthing of following main and auxilliary structure,equipments and panels and cable trench with the help of specified size MS flat along with cutting,bending and straightening of MS flat to give it proper shape,painting of all type of joints,risers,strips,with one coat of red oxide primer and two coat of green enamel paint in all side of surfaces as per drawing of earthing and standard practice including cost of all required consumables material, T&P, Labour etc. |
| 57 | Earthing with 75*10mm MS Flat |
| 58 | Earthing with 50*6mm MS Flat |
| 59 | Earthing with 25*6mm MS Flat |
| 60 | Excavation of Trench in Rectangular shape around L.A. structures for Mesh Earthing for 03 Nos. 120KV LAS by Fabrication of 06 Nos. 4 Meter long Electrodes with 36mm/40mm dia. M.S. Round having 150 mm long conical Shape, its Piercing Vertically in Ground with top 800 mm below ground level, Jointing Electrodes with 75*10 mm M.S. Flat by proper Welding. Two No. risers of 75*10 mm M.S. Flat shall be welded with existing main earth mat to Auxiliary structure, one separate riser will be taken from the laid earth mat to corresponding L.A. through surge counter for making of proper Mesh. Painting of the Shielding| Mesh/Earthing Strips with anti-corrosive Paint and back filling of excavated trench including the cost of labour, T&P etc. |
| 61 | Excavation of Trench in Rectangular shape around L.A. structures for Mesh Earthing for 03 Nos. 30KV LAS by Fabrication of 04 Nos. 4 Meter long Electrodes with 36/40mm dia. M.S. Round having 150 mm long conical Shape, its Piercing Vertically in Ground with top 800 mm below ground level, Jointing Electrodes with 75*10 mm M.S. Flat by proper Welding. Two No. risers of 75*10 mm M.S. Flat shall be welded with existing main earth mat to Auxiliary structure, one separate riser will be taken from the laid earth mat to corresponding L.A. through surge counter for making of proper Mesh. Painting of the Shielding Mesh/Earthing Strips with anti-corrosive Paint and back filling of excavated trench including the cost of labour, T&P etc. |
| 62 | Shifting of power cable from store to work place & laying of 33kV, 1-core 630mm2, XLPE copper conductor Power Cable to connect 33kV side of T/F (600 meter) |
| 63 | Installation of 33KV, 630 mm2, XLPE Power Cable outdoor termination kit for all six phases (06 Set). (01 set = 2 phases) (01 job include 3-phases of cables) |
| 64 | Laying and termination of following size of unarmoured control cable from control room to equipment cable rack (CB,CT etc) via cable trenches and fixing of it with the help of 25x3mm aluminium strip and 6mm dia GI nut and bolts on cable rack up to termination point by cable tray including tag wielding on equipments as per AE/JE direction and all associated works to complete the job satisfactorily. |
| 65 | 10Cx2.5 sqmm. |
| 66 | 6Cx2.5 sqmm. |
| 67 | 4Cx2.5 sqmm. |
| 68 | 2Cx2.5 sqmm. |
| 69 | Cable termination at VCB/CT/PT/BSI/LSI Junction Boxes to C&R Panel and CT/PT turrets to CT/PT Junction boxes with proper ferruling & dressing (Ferrule provided by contractor). |
| 70 | 2x2.5 mm2 |
| 71 | 4x2.5 mm2 |
| 72 | 6x2.5 mm2 |
| 73 | 10Cx2.5 sqmm. |
| 74 | Erection of control & relay panel for 40MVA T/F including shifting from store to erection site and proper earthing of panel and all associated work to complete the job satisfactorily. This work also include termination of all control cable in panel and associated equipments such as CB, LSI,BSI, CT,PT and all associated works. |
| 75 | Providing & fixing equipment names plate of MS Sheet 16 gauge of size 200x300 mm with hole of S/S in the top centre for fastering & writing name of equipment black colour after painting sheet with 02 coat of red primer & 01 coat Yellow colour. |
| 76 | Providing & fixing bay name display board of MS Sheet 16 gase size 400x250 mm with the help of MS pipe having inner frame approx. size 2\\"x1\\" with welding of two legs of MS angle of 03 feet and writing name of bay black colour after painting sheet with 02 coat of red primer & 01 coat yellow colour both side of display board including digging, grounting, concreating (1:2:4 Ratio), 1.5 feet from ground level & all associated work to installed Bay name display board. |
| 77 | Providing and fixing of protective wire mesh net of 1\\"*1\\" size having 4mm thickness between 40MVA T/F and LV side 33KV LA,fabrication of wire mesh frame the work including cutting,strengthening,welding and drilling of angle of size 5m*4m making 4m*3.5m size pocket for fixing net in frame. Top side fabrication the channel for fixing of post insulator 2*22kv top side to pass the jumper for reducing the load of LV side bushing. Digging the pit for foundation of size 12\\"*12\\"*24\\" and grouting the frame with cement stone,and sand in ratio 1:2:4(angle,MS flat shall be provided by department )free of cost. [ Please Enable Macros to View BoQ information |