| 1 | Comprehensive Maintenance Contract for the Addressable / Conventional Fire Alarm and Detection Systems installed at the buildings listed below, including 01 visit per month for each building, as well as visits whenever required in case of any defect in the system of any below listed buildings. The services shall be carried out by a team consisting of an Engineer, Technician, and 02 Nos. Helper, with the objective of keeping the system functional round the clock. The scope of work includes servicing, maintenance, testing and cleaning of the system—both internally and externally.The technical staff of the agency i.e. Engineer and technician shall also provide basic training to the fire staff on the operation and basic upkeepment / maintenance of the Fire Alarm system.All maintenance work shall be carried out to the entire satisfaction of and as per the directions of the Fire Officer/Engineer In Charge for the buildings listed below: |
| 2 | 1. Palika Kendra2. Mayur Bhawan3. Chanakya Bhawan4. Charak Palika Hospital (Old & New Building)5. Lok Nayak Bhawan6. Palika Bhawan7. Yashwant Place (including Residential Building Market)8. Chander Lok Building9. Palika Bazar10. Bapu Dham Tower 1 to 1011. Vidyut Bhawan12. Shivaji Stadium13. Talkatora Stadium and Annexie Building14. C.P. Corridor15. NDCC PH-II & Convention Centre16. Amrit kal Niwas, Aliganj 17. NDMC Type-II flats, Saket18. Palika Parking19. Mohan Singh Place20. Shaheed Bhagat Singh Place21. Palika Place22. Akanksha (Women Hostel)23. Palika Health Complex24. Kaka Nagar Bharat Ghar, 25. Community Centre Golf Link |
| 3 | 26. Community Centre Jor Bagh 27. Polyclinic, SBS Marg 28. Old Age Home Kali Bari 29. Swati Woking Girls Hostel 30. Harish Chander Mathur Lane Dispensary 31. Lodhi Road Dispensary 32. Sarojini Nagar Dispensary 33. Lodhi Colony Barat Ghar 34. Khan Market Bagar Ghar35. Mandir Marg Barat Ghar, 36. Moti Bagh Barat Ghar 37. PSOI Club, Nehru Park38. Aaradhna (Old Age Homes)39. East Kidwai Nagar Banquet Hall and Market40. Atal Adarsh Vidhyalaya, East Kidwai Nagar41. Atal Adarsh Prathmik Vidhyalaya, Kaka Nagar42. Palika Maternity Hospital43. Indira Niketan Working Girls Hostel, 44. Sarojini Nagar Barat Ghar, 45. Laxmi Bai Nagar Barat Ghar 46. Laxmi Bai Nagar Gymnasium47. Community Centre Babar Road 48. Zonel Service Centre Fire Brigade Lane 49. Pragati Bhawan 50. Disaster Management Centre Humanyun Road51. Veterinary Hospital, Moti Bagh |
| 4 | Carrying out repairing, servicing & testing of Fire Alarm System installed in NDMC Buildings as and when required on call and as per direction of Engineer-In-Charge. |
| 5 | Technician |
| 6 | Helper |
| 7 | Replacement / Supplying, installation, testing & commissioning of sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 8 | 4 Zone |
| 9 | 10 Zone |
| 10 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 11 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 12 | Replacement/Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required |
| 13 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 14 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required |
| 15 | Supplying, installation, testing & commissioning of addressable manual call point complete as required |
| 16 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required |
| 17 | Supply, Installation, Testing, and Commissioning of Loop Interface Module compatible with existing BOSCH Addressable Fire Alarm System, suitable for loop extension and integration with control panel, including all required accessories, wiring, and terminations, complete in all respects as per the direction of Engineer-in-Charge |
| 18 | Replacement/P/F/T/C of Emergency Lights (16/20W x 2 Nos.) Twin LED emergency Swivel type Beam Lights having minimum 90 Minutes and upto 5 Hours Battery Backup, Made out of CRCA/MS Powder Coated Sheet as per manufacturer’s Design, 12V, 7AH SMF Battery, Overcharging and Low Battery Protection, Fuse suitable for operation on 230V 50 Hz AC Supply etc. complete in all respect to the entire satisfaction of Fire Officer. |
| 19 | Providing and Fixing of Exit / Escape Route Signages / Safety instruction Board /Emergency Contact Plates/Evacuation Plan to be made of 3 mm +/- 10 % Aluminum composite panel with photo luminescent self glowing signages in desired text/ graphics fixed with mounting tape, steel screw which ever is required etc. complete to the entire satisfaction of Engineer-in-Charge/Fire Officer. |
| 20 | Provisioning of emergency exit route indicators width 50 mm as on surfaces such as steps, walls, pillars etc using photo –luminescent adhesive tape having sufficient luminous effect upto 2 hours during pitch darkness including providing transparent covering for protecting the photoluminiscent material from wear and tear complete all as specified and as directed by Fire Officer/Engineer-in-Charge. |
| 21 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as requireda) 25 mm dia |
| 22 | Supplying and installing the following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling using M.S. suspenders, including bolts and nuts, painting suspenders etc. as required. |
| 23 | 100 mm width x 50 mm depth x 1.6 mm thickness |
| 24 | Supplying and laying of of 2 X 1.5 Sq. mm Fire Alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete in all respect to the entire satisfaction of Fire Officer / Engineer-in-charge. |
| 25 | Credit of unserviceable material at site including dismantling the following existing irrepairable systems. |
| 26 | Fire Alarm Panel (4 Zone) |
| 27 | Fire Alarm Panel (10 Zone) |
| 28 | Smoke Detectors |
| 29 | Manual Call Boxes |
| 30 | Response Indicators |
| 31 | Sounders |
| 32 | Addressable Detector |
| 33 | Addressable Manual Call Point |
| 34 | Addressable Sounder |
| 35 | Emergency Lights Please Enable Macros to View BoQ information |