| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. |
| 2 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed |
| 3 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. |
| 4 | M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid. |
| 5 | M&L for tibba sand filling under floor or in foundations including gently punned as in cushioning to cable complete all as specified and directed. Note:- Punned thickness of sand shall be measured and paid. |
| 6 | M&L for broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 7 | M&L for precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar work including necessary form work and set in CM 1:6 complete all as specified and directed. |
| 8 | M&L for brick protection cover to the under ground cable (with old size sub class 'B' bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm all as specified and directed. |
| 9 | M&L for brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 10 | M&L Brick work using old size bricks with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:6 complete all as specified and directed. |
| 11 | M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms or any horizontal portion and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified & directed. |
| 12 | Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed. |
| 13 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 sqm each with shutters (without taking off shutters from the frames) and removing to or from store complete all as specified and directed. |
| 14 | S&F for solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, supplied and fixing in opening as specified and shown on drawing made on section 8 of SSR 2020 Part-II complete all as specified and directed. |
| 15 | S&F Factory made Solid PVC Moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2 mm thick moulded Prelam PVC Sheet on the front face & 2 mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 16 | M&L for factory-made uPVC white colour fixed window made of extruded profiles with wall thickness of 2.3mm(±0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (one vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mm) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass.Note: (i) Area should not exceed 1.00 sqm each. (ii) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. (iii) Net opening will be measured for payment purpose. |
| 17 | S&F factory made uPVC white colour sliding window, three track made of extruded profiles with wall thickness of 2.3mm (± 0.2mm), window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ±0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware Touch Lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, for area not exceeding 2.00 sqm each complete as specified and directed.Note : (i) The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. (ii) Net Opening will be measured for payment purpose. |
| 18 | S&F aluminium, anodised, barrel tower bolts of extruded section 200 mm long complete all as specified and directed. |
| 19 | S&F butt hinges, medium weight, cold rolled mild steel 100 mm long complete all as specified and directed. |
| 20 | S&F extruded aluminium alloy handles fabricated type anodised of 150 mm size complete all as specified and directed. |
| 21 | S&F Mortice lock, vertical type, size 100 mm, 4- lever mild steel body with two keys complete all as specified and directed. |
| 22 | S&F drawer lock, two-lever brass body grade-I of 65mm size complete all as specified and directed. |
| 23 | S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed. |
| 24 | M&L for auto close hinges, stainless steel, bright finish or electrogalvanised fixed complete all as specified and as directed. |
| 25 | S&F stainless steel handles, fancy type, of 200 mm size complete all as specified and directed.Make : Ebco / Hettich / Ultima / Hafele or equvalent make as approved by GE. |
| 26 | S&F stainless steel (SS) tower bolts, fancy type, of size 150 mm long complete all as specified and directed.Make : Hafele / Hettich / Ultima or equivalent make as approved by GE. |
| 27 | M&L for cupboard magnet, stainless steel, bright finish or electro-galvanised of size 55 x 29mm complete all as specified and directed .Make : Godrej, Hafele,Ultima,Hettich |
| 28 | S&F 25 mm dia stainless steel, silver & chrome finish, fancy type, anti-rust curtain rod complete as all specified and directed. |
| 29 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size, floor door stopper of size 200mm etc. using medium weight, aluminium section as follow :- (a) Frame (top & side) section shall of size 101.60x 44.75 x 2.4 mm (Section 14021)(b) Vertical Members of shutter section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560).(c) Top members of shutter section shall be of size 83.50 x 44.45 x 2.00 mm (19581).(d) Lock rail (Middle member) of shutter section shall be of size 150 x 44.4 x 3.00 mm (Section No 19596)(e) Bottom Members of shutter section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584)(f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370)Note:- Section given above are of Make Jindal, the contractor may use similar section of other make as mentioned in Appx 'B' of PS. |
| 30 | S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) partition with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead, joining cleat etc. for fixing in position, using medium weight, aluminium section as follow :- (a) Outer Frame (top / bottom / side) section shall of size 101.60x 44.45 x 2.5 mm (Section 20102).(b) Middle members (Horizontal / Vertical) section shall be of size 101.60 x 44.5 x 2.50 mm (Section No 20057).Note:- Section given above are of Make Jindal, the contractor may use similar section of other make as mentioned in Appx 'B' of PS. |
| 31 | M&L for mild steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 32 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. |
| 33 | M&L for carried out water roof treatment as under :(a) All visible cracks to be opened up in V shape cleaned properly with wire brush washed and filled with cracks filling compound for cracks up to 5mm width / depth of cracks. (b) Cracks of more than 5mm width / depth are filled with URP cement grouting by injecting through nozzles till refusal. The size and spacing of nozzles shall be as per manufacturer instruction or as directed by Engineer-in-Charge.(c) After drying, the roof coat paint shall be applied at rate of one liter per square meter with roller in both direction with a minimum gap of 12 hours’ time period for each direction over a self-primer coat at rate of 0.50 liter of water mixed to one liter of roof coat paint (three coats including primer shall be applied).(d) The roof treatment shall be got carried out by the manufacture or their authorised applicators only. (e) Necessary guarantee for 5 years shall be submitted by the contractor.Make : (i) Roof Coat : Berger (HS Damp Shield Elasto) / Asian (Smart Care Damp Proof) / Sika (Sikalastic-510 CoolCoat) or equivalent as approved by GE.(ii) Cement Grout : Dr. Fixit (Fixit Pidicrete URP Model:301) or equivalent in Fosroc / Choksey chemicals / Sika / Berger (HS Super Grout) or equivalent as approved by GE. |
| 34 | S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 35 | M&L false ceiling at all heights with semi perforated 12 mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter locking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 4x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, and direction of engineer-in-charge complete all as specified and directed. |
| 36 | M&L for 18-20 mm thick High Density high moisture resistant (HDHMR) board for kitchen cupboard / door shutter of make Action tesa / Pearlwood or equivalent make as approved by GE, one side colour / white laminate and other side decorative as in modular kitchen / cabinets / door shutter fixed with minifix hardware wherever required including edge band 22mm wide, 0.80mm thick of matching colour on exposed surfaces of board fixed with polymaster adhesive of REHAU make or equivalent including trimming edges of edge band to true line of thickness of board by manual trimmer, fixed to wall etc. complete all as specified and directed. |
| 37 | M&L for 8 mm thick HDHMR (High density high moisture resistant) board of Action tesa / Greenply or equivalent make both side white laminate as in back of kitchen cabinets/portion of cupboard etc complete all as specified and directed. |
| 38 | M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 20 mm thick in CM 1:4 complete all as specified and directed. |
| 39 | M&L for machine cut kota stone slab flooring mirror finished 40-50 mm thick (for shelf / partition / suspended slab including rubbing and polishing complete all as specified and directed. |
| 40 | M&L for machine cut kota stone slab mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) in riser of step ,skirting, dado and pillar over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 41 | M&L for 75 mm thick Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 42 | M&L for 100 mm thick Cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 43 | M&L for surface preparation by removal of all loose particle to ensure clean, smooth and dry surface and laying 25mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate finished even & smooth without using extra cement with integral water proofing compound at rate of 03% per KG of cement of make approved by GE and curing the same as per manufacturer instruction complete all as specified and directed. |
| 44 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and smooth with using extra cement complete all as specified and directed. |
| 45 | M&L for glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7 mm / 300x 600x7 mm / 450x 300x7 mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in CM 1:4 complete all as specified and directed. |
| 46 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 47 | S&F for rubber moulded machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed. |
| 48 | Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed. |
| 49 | M&L for rendering 10 mm thick in CM 1:4 on concrete surface and finished even and smooth with out using extra cement with and including integral water proofing compound at rate of 03% by weight of cement or as per manufacturer specification complete all as specified and directed. |
| 50 | M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed. |
| 51 | M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed |
| 52 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 53 | M&L for rendering 05 mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed . |
| 54 | M&L for 15 mm thick screed bed or bedding layer in CM 1:6 surface finished fair and even for laying floor finishes complete all as specified and directed. |
| 55 | M&L for complete removal of existing surface of ceiling (plastered or un-plastered) by washing, rubbing down and stopping of distempered and surface to be repaired by filling putty in holes & depression if required to obtain even and uniform surface etc and applying two coat of oil bound distemper on ceiling white or tinted including scaffolding arrangement, trestles, ladders etc for execution of work up to four storey complete all as specified and directed. |
| 56 | M&L for preparation of new surface of walls of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc. |
| 57 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description with a coat of 1 mm thick wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.Make for Acrylic Emulsion Paint : Apex Ultima of Asian Paint / WeatherShield Max of Dulux / WeatherCoat Anti Dust of Berger or equivalent make as approved by GE.Note :- Acrylic Emulsion Paint shall be carried out as specified in clause 15.17 of SSR Part-I including all necessary arrangement such as scaffolding / working plateform for execution of work upto four storey building etc. |
| 58 | S&F 4.8 mm thick sheet glass, ordinary quality and glazing with neoprene rubber beading in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 59 | M&L for preparation of new or previously untreated plastered or concrete surface of ceiling, of any description, over 10 cm in width or girth and apply two coat of plastic emulsion paint over a coat of primer and including 1 mm thick putty on ceiling complete all as specified and directed. |
| 60 | M&L for complete removal of existing treatment and preparation of old surface of wall of any description, and apply two coat of plastic emulsion paint over a coat of primer and including 1 mm thick wall putty complete all as specified and directed. |
| 61 | M&L for preparation of new or previously untreated plastered or concrete surface of any description, over 10 cm in width or girth and apply two coat of plastic emulsion paint over a coat of primer and including 1 mm thick putty on wall complete all as specified and directed. |
| 62 | M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 63 | M&L for cast iron nahani trap with grating including jointing to waste pipe 75 mm diameter of outlet fixed in cement concrete (1:2:4) type B1 complete all as specified and directed. |
| 64 | S&F in repair 15 mm bore chromium plated urinal valve with built in auto closing system control complete all as specified and directed. |
| 65 | S& F in repair 18mm thick granite urinal partition of size 950x450 mm, urinal partitions terminating about 40cm above floor line complete all as specified and directed. |
| 66 | S&F 16 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified. |
| 67 | S&F 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls / ceiling or laying in floors including special fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified. |
| 68 | S&F in repair for 2-in-1 Angle Cock / 2 Way Angle Valve, fancy type chromium plated cast copper alloy, for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. |
| 69 | M&L for providing circular, raised platform of height 20 cm below the tank and base dia 25 cm more than the external dia of PVC tank of 500/1000 liters using PCC 1:3:6 type C1 using 20 mm graded stone aggregate with smooth finish including necessary form work etc. complete all as specified and directed. |
| 70 | M&L for Double Wall Corrugated (DWC) pipe of class SN-4, IS-16098 (part-II) of 200mm bore (internal), laid to slope in trenches, jointed complete with coupler, bends, Tee, reducers etc and tested complete all as specified and directed.Make : Ultra plus of Supreme / Corfit of Prince / D-Rex of Astral or equivalent as approved by GE. |
| 71 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed. |
| 72 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 73 | M&L in repair for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 74 | S&F PVC (SWR) bends any radius of 75 mm bore without access door complete all as specified and directed. |
| 75 | S&F PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed. |
| 76 | S&F in repair PVC (SWR) bends any radius of 110 mm bore without access door complete all as specified and directed. |
| 77 | Taking up or down steel tubing and connections including cleaning if refixing required for 15 mm bore of pipe complete all as specified and directed. |
| 78 | Taking up or down steel tubing and connections including cleaning if refixing required for 20 mm bore of pipe complete all as specified and directed. |
| 79 | Dismantling water tanks of any description, capacity exc 250 and not exc 500 litres and removing from site complete all as specified and directed. |
| 80 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 500 litre capacity hoisted and fixed in position complete all as specified and directed |
| 81 | S&F in repair bib taps cast copper alloy with crutch or butterfly handle, long body, screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated of 15 mm bore dia of pipe complete all as specified and directed. |
| 82 | S&F in repair for 15mm bore dia of pipe pillar taps cast copper alloy, with capstan head chromium plated fancy type screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 83 | S&F in repair stop valves, fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions for 20 mm bore dia of pipe complete all as specified and directed. |
| 84 | S&F in repair ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule of 20 mm bore dia of pipe complete all as specified and directed. |
| 85 | S&F PVC connection 15 mm size bore with PTMT nuts of length 450 mm complete all as specified and directed. |
| 86 | S&F in repair soap dish, any type fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 87 | M&L in repair wash down water closet vitreous china white pedestal pattern with 'P' or 'S' trap including connecting to outgoing drain pipe & to flushing pipe also including plastic water closet seat, black/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, excluding flushing cistern and flush pipe complete all as specified and directed. |
| 88 | M&L in repair for Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as specified and directed. |
| 89 | M&L toilet paper holder, of stainless steel with flat recessed type, chromium plated, fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. Make:- Jaquar CAT Part No. CPA-CHR-1151 / Grohe Cat Part No. 40367000 / Kohler cat Part No. K-5633IN-CP or equivalent model of make as approved by GE. |
| 90 | M&L in repair for vitreous china wash basin, white,flat back, size 550 x 400 mm with pedestal, brackets, including PVC connection of 450 mm long, PVC (HDPE) 32 mm bore waste pipe, brass couplings 32 mm CP etc. complete all as specified and directed.Make:- Jaquar Cat part No. KUS-WHT-35935 / Grohe Cat Part No. 39231000 / Kohler cat Part No. 25816IN-0 or equivalent make as approved by GE. |
| 91 | S&F in repair looking mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge , mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete all as specified and directed. |
| 92 | S&F PVC waste pipe minimum 600 mm long suitable for 32 / 40 mm dia of outlet for wash hand basin / sink complete all as specified and directed. |
| 93 | S&F in repair for single piece WC With UF Soft Close Slim Seat Cover, Hinges, Flush Cistern Fitting, fixing accessories S / P Trap as per manufacturer instructions complete all as specified and as directed. Make : Jaquar CAT Part No LYS-WHT-38851S300UFSMN / Hindware Cat Part No. 92565 (S-22) / Cera Cat Part No. S1013123 or equivalent as approved by GE. |
| 94 | S&F in repair angle stop valve, fancy type chromium plated cast copper alloy, for 15 mm bore dia of pipe screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed. Make:- Jaquar CAT Part No OPP-CHR-15053PM / Kholer CAT part No. 11568IN-7B-CP / Grohe CAT Part No 2201600M or equivalent as approved by GE. |
| 95 | S&F in repair waste coupling of brass CP for 32 mm bore dia of pipe half or full threaded with long shank complete all as specified and directed. |
| 96 | S&F in repair health faucet (hand shower) chromium plated suitable for 15 mm dia pipe with 1.2 metre long flexible tube with non return valve and wall hook including making connections and fixed in position complete all as specified and directed.Make : Jaquar CAT Part No ALD-CHR-577 / Kholer CAT Part No K-12927IN-CP / Roca CAT Part No RF9060A1 or equivalent make as approved by GE. |
| 97 | S&F in repair chromium plated towel ring round (20cm dia) / square (20cm x20cm) shape (minimum weight 300gm) with round flange complete all as specified and directed. |
| 98 | S&F in repair chromium plated Hands-Free Jet spray for Pedestal type WC with PVC fexible cord of suitable length complete all as specified and directed. |
| 99 | Supply, installation, commissioning and testing of LT Panel, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply) CPRI approved, factory assembled, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm(for external) and 2 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged , double door opening for external, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel grey paint first quality) over a coat of red oxide primer complete mounted on angle iron leg made of angle iron 40mm x 40mm x 6 mm and 60 cm high above GL and 15 cm embedded in ground with PCC 1:2:4 type B1 of block size 30x30x30 cm comprising of the following.(a) Copper Bus bar: - Bus bar chamber having 4 nos air insulated copper strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, as well as outgoings shall have copper TPN extension links (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs.(b) Incoming: -(i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade, 125 amps rating 4 pole,36 KA, Adjustable thermal and adjustable magnetic release specially fixed for incoming supply with overload, short circuit and earth fault protection, adjustable type (Ics=100%Icu) - 01 No. (ii) Voltmeter 0-500V with selector switch 96 mm X 96 mm square flush mounted, with three-way rotary selector switch - 1 No.(iii) Ammeter size 96 mm X 96 mm square dial flush pattern having dual range 500 amp with three-way rotary selector switch - 01 no.(iv) Three Nos CTs of suitable ratio (set of three)-01 Set(v) Indicating lamps (R,Y,B) - 01 set of three(c) Outgoing(i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade 100 amps rating and 25 KA rupturing capacity, adjustable thermal and fixed magnetic type (Ics=100%Icu) - 01 Nos.(i) MCCB 4 pole, LT 415 Volts, 50 Hz AC grade 63 amps rating and 16 KA rupturing capacity, adjustable thermal and fixed magnetic type (Ics=100%Icu) - 01 Nos.Note: -(i) All incoming/ outgoing cables shall be connected by suitable size gland plate /glands. And All spreader terminals of MCCBs should be connected with extension links (bus bar).(ii) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (iii) Panels shall be placed above 60 cm from ground level(iv) Outgoing Cables shall be fed with solid busbar connectors. |
| 100 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| 101 | Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy