| 1 | Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls Brick / stone masonry in Cement mortar walls under 3m high. |
| 2 | Dismantling, clearing away and carefully stacking materials useful for re-use for floor finish and dadooing walls in cement mortar with mosaic tiles/ glazed tiles / cuddapah slabs etc., as directed by the departmental officers |
| 3 | Supplying and filling in foundation, basement, etc with conveyed earth in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | Brick work in Cement Mortar 1:5 using best quality Burnt Clay Brick of size 9\\" x 4 3/8\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 5 | For Superstructure In Ground Floor |
| 6 | For Superstructure In First Floor |
| 7 | For Superstructure In Second Floor |
| 8 | Paving the floor with best quality Double Charged Vitrified Tiles 600 x 600 x 8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 9 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. |
| 10 | Reinforced cement concrete precast slab 50mm thick using 20mm Jelly |
| 11 | Easening the doors and windows including fixing of furniture fitting etc., complete. |
| 12 | Renewing the broken glass panes of 3mm. Thick with new plain glass panes of 3mm. Thick including fixation in position with teak wood beeding of size 25mm x 12mm alround the glass panels with nails etc.,. |
| 13 | Supplying, Fabricating, erecting and fixing Hilux (or) equivalent Gyp Board FALSE CELING upto a ceiling height of 4.50 m from floor level using Hilux board Plain sheet 10mm thick which includes shaped GI channels of size 25 x 25 x 0.50 mm thick suspended from ceilling at 1.2 m both longitudinal and cross vertical support and fixing shaped GI channels of size 50 x 30 x 0.50 mm and 150 x 10 x 0.50 mm thick at 0.60m centre longitudinal and cross direction for vertical supports and fixing U shaped GI channels of size 50 x 30 x 0.50 mm thick and 50 x 10 x 0.50 mm thick at 0.60 m centre to centre in cross direction and respectively for horizantal supports of zig - zag pattern and fixing of Gyp board in the panel provided in the desing pattern given and sprating the standard specification and as directed by the departmental officers. The rate shall be inclusive of finishing the edges and wall junctions with suitable lipping and cornice arrangements. |
| 14 | Supplying and fixing in position of 12 mm thick first quality bolth side film face dencified of water and fire proof plywood (IS 4990:2011) for shuttering the door, window, and ventilators including fixing with country wood reepers of size 50 x 25mm including cost of labour charges for fixing and removing the same after the completion of counting. |
| 15 | Supplying and fixing and fabricating of Plywood wall partition using 19mm plywood and , Aluminium channel of size 101.60x44.50x3.18mm etc., The cost including screws,gum, labour and fixing and after removing the counting is over etc., |
| 16 | Supplying and fixing of weld mesh for closing windows and verandah openings including fixing with country wood reepers of size 50x25mm, Screws, etc., The cost includes removing the same after the counting is over . |
| 17 | Supplying and fixing in position of weld mesh enclosure in Counting Hall by using Square tube of size 50mmx50mmx4.5 for vertical support and 35mmx35mmx3.2 for Horizontal support at 0.90cm interval etc., including cost of materials, cutting, welding, primer, transportation, labour charges for fixing and removing the same after the counting is over. |
| 18 | Supplying and fixing of Gate with using weld mesh 7.5x2.5cm.10 gague, Square tube of size 35mmx35mmx3.2 for frame including cost of materials, cutting, welding, primer, transportation, labour charges for fixing and removing the same after the counting is over. |
| 19 | Providing to barricading arrangements from building entrance to counting hall (inner barricade) by using Casurina props 10-13 cm at 0.60m interval for vertical post and 8-10 cm dia casurina poles for horizontal members 0.45 intenal tied with coir and removing the same after the counting is over etc., complete., |
| 20 | Providing to barricading arrangements from road to building entrance (outer barricade) by using Casurina props 10-13 cm at 0.60m interval for vertical post and 8-10 cm dia casurina poles for horizontal members 0.45 intenal tied with coir and removing the same after the counting is over etc., complete., |
| 21 | Supplying and fixing and fabricating of Score board using 19mm plywood and , Aluminium channel of size 101.60x44.50x3.18mm, L angle etc., The cost including bolts,screws,tranportation charges, labour and fixing and after removing the counting is over etc., |
| 22 | Supplying and fixing of MS Square tube angle of following sizes of approved quality for uses of various type of truss works, including cost of transportation, cutting, welding, removing after the counting is over,etc., complete |
| 23 | Angle of size 50mm x 50mm x 4.5 |
| 24 | Angle of size 35mm x 35mm x 3.2 |
| 25 | Angle of size 25mm x 25mm x 3.2 |
| 26 | Supplying and fixing by drilling holes and not by puching for Roofing with pre painted Galvalum sheet of 0.47mm thick of best approved quality with required size with curved shape and white ridge sheet with necessary bolts and nuts bitumen washers, including cutting the sheet to the required size found necessary during execution etc., Complete complying with standard specifications. [The sheet should be got approved by the Engineer incharge before use on works] |
| 27 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 28 | 110mm dia PVC soil / waste pipe |
| 29 | 75mm dia PVC soil / waste pipe |
| 30 | Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply / Above ground level. |
| 31 | 32mm dia UPVC pipe |
| 32 | 25mm dia UPVC pipe |
| 33 | 20mm dia UPVC pipe |
| 34 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. |
| 35 | 32mm dia Gun Metal Gate Valve |
| 36 | 25mm dia Gun Metal Gate Valve |
| 37 | Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 38 | Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without Pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 39 | Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm \\"P\\" or \\"S\\" trap connecting with PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) |
| 40 | Providing counter arrangements at the counting hall for getting signature from the candidates authorised agents to a size of 9\\"x5\\" and tied edges with PVC pipe 3/4\\" dia including all labour and materials charges etc., complete |
| 41 | Supplying and fixing of Counting hall entrance gates by using Square tube of size 50mmx50mmx4.5 for outer frame and 35mmx35mmx3.2 for inner supports, bottom closed with GI sheet at a height of 0.75cm etc., including cost of hinges, aldrops, cutting, welding, primer, transportation, labour charges for fixing and removing the same after the counting is over. |
| 42 | Supplying fixing, placing inposition of Aluminium adjustable ladder for using to wrote vote counting score on score board at a time of counting. The Cost including transporatation charges, loading and unloading charges etc., complete. |
| 43 | Hire Charges for fixing of Arabian panthal of size 20'x20' including the cost of transport, laying and removing the same after the counting is over |
| 44 | Hire charges for providing Back drop of size 6'x4' with covering cloth including cost of transport, laying and removing the same after the counting is over |
| 45 | Hire charges for Supplying and fixing of Best quality of Curtain with designed Anchor in Kancheepuram RO room. Including cost of Transport, Screws, Drilling, and also removing the same after the counting is over. |
| 46 | Hire Charges for best quality designed Sofa set the cost includes tranportation charges, loading and unloading charges and also removing the same after the counting is over. |
| 47 | Hire Charges for best quality Teapoy of size 0.45mx0.60mx0.60m the cost includes tranportation charges, loading and unloading charges and also removing the same after the counting is over. |
| 48 | Hire charges for spreading the red synthetic carpet of approval quality and colour including the cost of transport, laying and removing the same after the counting is over |
| 49 | Providing Mortice Lock-(Godrej or equivalent) with required screws with 3 Keys |
| 50 | Hire Charges for Plastic chairs for counting Staff and counting assistant in counting hall, and dining use. The Cost including transporatation charges, loading and unloading charges etc., complete. |
| 51 | Hire Charges for steel tables for dining use. The Cost including transporatation charges, loading and unloading charges etc., complete. |
| 52 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT |
| 53 | Hire Charges for best quality white colour Table cloth for Officers table and Chair in RO room etc., complete. |
| 54 | Supplying and fixing inposition of PVC foam type name boards in all counting halls,Strong rooms, Store rooms and RO room. The cost includes transportation charges, screws, drilling, and also removing the same after the counting is over. |
| 55 | Size 4'x3' |
| 56 | Size 6\\"x6\\" |
| 57 | Size 1'6\\"x3\\" |
| 58 | Supplying and fixing inposition of flex sign boards at a time of polling and counting. The cost includes casurina props, screws, gum, transportation charges and also removing the same after the counting is over. |
| 59 | 8' x 6' |
| 60 | 6' x 4' |
| 61 | 4' x 3' |
| 62 | 3' x 2' |
| 63 | 2' x 1'6\\" |
| 64 | Supplying and fixing inposition of PVC Designation board of size 1'x3\\" for officers at a time of counting in RO room & Counting Hall. |
| 65 | Supplying, fixing and fabricating of Postal vote transparent counting box including cost of transportation charges, screws, fevicol and and all other incidental charges etc., complete |
| 66 | Hire charges for frisking point of Size 1.80x1.80x1.80m using Square tube of angles and alround covered with best quality cloth etc., The cost includes transportation charges, fixing and also removing the same after the counting is over. |
| 67 | Repair and maitenance of all floor Industrial type Reverse Osmosis system including cost of cooling and hot water arrangements and other repairs etc., complete |
| 68 | Clearing and conveying the debris and unwanted materials to outside the campus with in lead of 5Km |
| 69 | Levelling the uneven surfaces by removing the heaps of earth etc., by plugging out the tree trunk with roots below the ground level and removing the bushes using JCB Machinery etc. complete complying with standard specications and as directed by the departmental officers. |
| 70 | Hire charges of crane for fixing plywood to closing windows at building outer side including cost of crane operator, fuel and other incidental charges etc., complete |
| 71 | GST @ 18 % Please Enable Macros to View BoQ information |