| 1 | Earthwork in excavation in foundation Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth a obtained to a distance Up to 50M including all lifts with leveling remming the foundation trenches removing roots of trees shurbsall complete as per approved design, building specification and direction of E/I |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item -A) |
| 3 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 4 | Providing designation 75B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I. |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level: 1:2:4 (1 Cement : 2 Coarse sand (zone -III) : 4 Graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, exluding the cost of centering, shuttering, finishing and reinforcement- all work up to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand (zone-iii): 3 graded stone aggregate 20 mm nominal size). |
| 7 | Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 |
| 8 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 9 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand ofF.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mmdepth curing, taxes and royalty all complete as per building specification and direction of E/I |
| 10 | Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarsesand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, pillars, piers, Abutments, posts and Struts. |
| 14 | Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 15 | Centering and shuttering including strutting, propping etc and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 16 | Reinforced cement concrete work in walls (any thickness), including attached plasters, buttresses, plinth and string courses, fillets, column pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement :1.5 coarse sand (zone -iii):3 graded stone aggregate 20 mm nominal size) |
| 17 | Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed inposition and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and directionof E/I. (where materials is not supplied by the deptt.)including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface allcomplete as per building specification and direction of E/I |
| 18 | Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size, |
| 19 | Providing and laying Doublecharge vitrified floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS: 15622 / ISO 13006 of approved make,in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc.complete. Size of Tile 600x600 mm building specification and direction of E/I |
| 20 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 21 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 22 | Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 23 | Supplying fitting and fixing PVC door frame taxes all complete as per building specification and direction of E/I. |
| 24 | Supplying fitting and fixing PVC door shutter taxes all complete as per building specification and direction of E/I. |
| 25 | S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.) |
| 26 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 27 | Providing and laying 6 mm thick precast white glazed tiles in wall over 12 mm cement mortar (1:3) and jointed -do-do all complete job as per spe. And direction of E/I. |
| 28 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification anddirection of E/I. |
| 29 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) building specification and direction of E/I |
| 30 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.building specification and direction of E/I |
| 31 | providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing excluding carraige of M.S.bars to work site , cutting, bending, and binding with annealed wire with cost of wire removal of rust placing the rod in position all complete as per building specification and direction of E/I.8 mm dia. |
| 32 | 10mm Dia |
| 33 | 12mm Dia ,16mm Dia |
| 34 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 35 | Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or anyother approved water proofing compound including screening, curing with all leads and lifts of water, scaffoldingtaxes and royalty all complete as per building specification and direction of E/I |
| 36 | 500mm diameter C.I cover (medium duty) the weight of the cover to be not less than 58 kg. |
| 37 | Providing and laying vitrified floor tiles for step of stair in with water absorption less than 0.08% and conformingto IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement andmatching pigments etc., complete step tiles & have bullnose, Anti and self embossed line. Size of Tile 1200x300mmx15 mm other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I |
| 38 | Supplying Fitting and fixing vitreous white glazed earthen ware wash hand basin of parry ware of hindustan -do-do- all complete job. |
| 39 | Supplying Fitting and fixing vitreous white glazed earthen ware wash hand basin of parry ware of hindustan -do-do- all complete job. |
| 40 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost ofcentering, shuttering and finishing.1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 41 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 42 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 43 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead anddisposal of unserviceable materials with all leads all complete as per direction of E/I |
| 44 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal ofunserviceable materials with all leads all complete as per direction of E/I. disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 45 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I .unserviceable materials with all leads all complete as per direction of E/I. disposal of unserviceable materials with all leads all complete as per direction of E/I |
| 46 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab byapplying two Component, factory designed, ready to use, acrylic modified flexible |
| 47 | Providing 25mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with Integral waterproofing compound Liquid @125 ml per bag cement including screening, curing |
| 48 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.proofing compound Liquid @125 ml per bag cement including screening, curing |
| 49 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 50 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidatedand grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 51 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.15 mm nominal dia Pipes |
| 52 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.20 mm nominal dia Pipes |
| 53 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.25 mm nominal dia Pipes |
| 54 | Providing and fixing male ended 15 mm dia brass bib cock of approved quality -do- do all complete job. |
| 55 | Providing and fixing brass stop cock of approved quality all complete as per spe. And direction of E/I |
| 56 | Providing and fixing 15 mm size CP brass pillars of approved quality all complete as per spe. And direction of E/I |
| 57 | Eaeth work in excavation for laying of differrent types and sizes of RCC Spun pipes with disposal of excavated earth with in initial lead and lift as per spe. And direction of E/I. |
| 58 | Labour for laying ,fitting and fixing NP2 RCC spun pipe with collars in lines - do-do - all complete job. |
| 59 | Cost of water storage tank. |
| 60 | Supplying fitting and fixing 2 HP Submersible pump set 150 mm dia. |
| 61 | Supplying flat flexible submersible cable with copper conductor PVC insulated and PVC sheated 3 core 2.5 sq mm. |
| 62 | D.O.L Starter with SS enclouser . |
| 63 | supplying 32 mm G.I Pipes |
| 64 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 65 | S/F/F Viterous white glazed earthen ware IWC of parry, hindustan -do-do-all complete job. |
| 66 | Providing and fixing on wall face unplasticised rigid PVC Rain water pipes conferming -do-do all complete job.110 mm dia. |
| 67 | Supplying Fitting and fixing vitreous white glazed earthen ware wash hand basin of parry ware of hindustan -do-do- all complete job. |
| 68 | Wiring for light /fan point / exhause fan point / call bell point with 1.5 sq.mm FRPVC inlsulated copper conductor single core cable in surface / recessede conduit with paino type switch phenolic laminated sheet suitable size M.S box insulated copper conductor. Group-C |
| 69 | Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire |
| 70 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire |
| 71 | Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and makinggood the same in case of recessed conduit as required.25mm dia |
| 72 | 32mm dia |
| 73 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excludingmodular plate etc. as required.5/6 amps one way switch |
| 74 | 15/16 amp one way switch |
| 75 | 5/6 amp 3 pin socket outlet |
| 76 | 5/16 amp 6 pin socket outlet |
| 77 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excludingmodular plate etc. as required. |
| 78 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 79 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4/5 Module (78mm x140mm x 50mm) |
| 80 | 8/9Module (78mmX230mmx60mm) |
| 81 | Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 82 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 83 | Supplying and fixing Ding dong sound call bell single phase, 230 volts,complete as required. |
| 84 | Installation testing and commissionging of prewired fluorescent fitting/compactfluorescent fitting of all type complete with accessories and tube etc directly/all including connection with 1.5sqmm FRPVC insulated copper conductor single core cable and earthing etc as required |
| 85 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required. |
| 86 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as |
| 87 | Supplying and fixing following ways, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 Way (4+18), Double Door Horizontal Type |
| 88 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections,testing and commissioning etc.,as required.6 / 32 Amp Single Pole |
| 89 | 6/32 Amp TPN |
| 90 | 40 Amp TPN |
| 91 | Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.63 Amps |
| 92 | Providing and fixing M.V danger Notice plate of 200 mm X 150 mm of mild steel at least 2 mm thick and vitreous enamelded white on both side with inscription in single red colour in front side as required. |
| 93 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke andsalt) as required. |
| 94 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 95 | S.I.T.C of following rating surface mounted LED Tube Lighting FittingSuitable for 230V 50 Hz, Single Phase Supply etc. complete as10/12 W LED Tube Light |
| 96 | 20/22 W LED Tube Light |
| 97 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :-Usha/Crompton / Havells . |
| 98 | Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete asrequired1200 mm ( 48\\") BLDC 5 Star rating 32W Ceiling Fan |
| 99 | Carriage of materialsBricks |
| 100 | Stone chips |
| 101 | Cement +steel |
| 102 | Paver block |
| 103 | Add 18% G.S.T |
| 104 | Add 1% L.C. Please Enable Macros to View BoQ information |