| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out etc in any type of soil, complete all as specified and directed. |
| 2 | PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete all as specified and directed. |
| 3 | Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4, complete all as specified and directed. |
| 4 | Hardcore of broken stone or boulder of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick, watered and rolled/rammed to a true surface, complete all as specified and directed. |
| 5 | 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
| 6 | 100mm thick Plain Cement concrete Type D-2, 1:4:8 (using 40mm graded crushed aggregate) as in sub-base of floors, path/hardstandings etc, finished even and rough to receive topping layer complete all as specified and directed. |
| 7 | 40 mm thick PCC 1:2:4 type B-1, (Using 20 mm graded crushed stone aggregate), as in flooring/path/hardstanding etc & finishing the surface even and fair complete all as specified and directed. |
| 8 | Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular), area of each tile exceeding 0.11 Sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with & including 15 mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed. |
| 9 | Glazed ceramic coloured digital tiles 300x450x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 10mm thick rendering in CM 1:4 on other than fair faces of brick work finished even and fair to receive tiles, complete all as specified and directed. |
| 10 | Rendering 15mm thick in cement mortar (1:4) on fair faces of the brick work or cement concrete surfaces, finishing the surface even and smooth without using extra cement, complete all as specified and directed. |
| 11 | Rendering 15mm thick in cement mortar (1:6) on other fair faces of the brick work or cement concrete surfaces, finishing the surface even and smooth without using extra cement, complete all as specified and directed. |
| 12 | Rendering 5mm thick cement plaster with cement mortar(1:3) on concrete surface as in ceiling finished even and smooth without using extra cement, complete all as specified and as directed. |
| 13 | Preparation of newly plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed. |
| 14 | Preparation of newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed. |
| 15 | Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whitening primer complete all as specified and as directed. |
| 16 | Preparation of old painted surfaces with complete removal of existing treatment & applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm on wall complete all as specified and directed. |
| 17 | Factory made box type steel ventilators top hung shutter shutters glass/glazed including guard bars ,hinges,steel handle,tower bolt and steel peg stay,complete with or without glazing bars ,devotiled or welded,including one coat of red oxide primer complete shown as drawing No (CEUZ/TD/1517/15 Sh No 1/3 to 3/3) |
| 18 | Solid PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S square tube, supplying and fixing in opening as per specification and drawing, complete all as specified and directed. |
| 19 | Factory made solid panel PVC door shutter/ cupboard shutter/ kitchen cabinets 30mm thick style wooden texture consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site, complete all as specified and directed. |
| 20 | Butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked complete all as specified and as directed. |
| 21 | 200 mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified and as directed. |
| 22 | Aluminium handles fabricated type anodised of size 125mm with screws long ISI marked complete all as specified and directed |
| 23 | 250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections & fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified and directed. |
| 24 | Preparation of new steel surfaces of any description exc 10 cm width or girth, and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 25 | Bib cock 15mm bore, fancy type chromium plated cast copper alloy with capstan head fixed in repairs all as specified and directed. |
| 26 | Angle cock with wall flange , cast copper alloy, chromium plated fancy type screwed for 15 mm bore iron pipe fixed in repairs, complete all as specified and directed. |
| 27 | Pillar taps 15mm cast copper alloy CP, fancy type with capstan head, screwed down high pressure with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nut, screwed for iron pipe 15 mm bore.fixed in repairs, complete all as specified and as directed. |
| 28 | Hand shower health faucet with 1 mtr long easy flexible chromium tube finish and wall hook all as specified and directed. |
| 29 | Vitreous china wash basin, white, flat back, size 550x400mm including CP mixer for mixing hot and cold water for pipe of bore 32mm, waste fitting chromium plated brass, chromium plated steel chain and rubber plug, porcelain stopper, a pair of CI brackets and waste pipe etc., fixed in repairs complete all as specified and as directed. |
| 30 | PVC valve less, Symphonic action type, flushing cistern of capacity 10 liters, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete, fixed in repairs complete all as specified and as directed. |
| 31 | Vitreous china wash down water closet pan pedestal pattern in white colour with 'P' or 'S' traps excluding seat cover, flushing cistern and flush pipe fixed in repairs complete all as specified and directed. |
| 32 | PTMT Grating Round 140 mm dia fixed in repairs complete all as specified and directed. |
| 33 | 20mm nominal outer dia chlorinated polyvinyl chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement complete all as specified and directed. |
| 34 | Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) 3 layer hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed. |
| 35 | Ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe 20 mm dia (minimum weight 210 gms) complete all as specified and directed. |
| 36 | 110mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc., complete all as specified and directed. |
| 37 | PVC (SWR) Type-B pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center, fixed in repairs complete all as specified and directed. |
| 38 | 75mm bore PVC SWR Type-B ( pressure not less than 6 kg /cm2) pipes single socket in any length with rubber ring joints laid in trenches or in floors etc., fixed in repairs complete all as specified and directed. |
| 39 | PVC(SWR) Type-B pipes 75 mm bore single socketed, in any length with rubber ring joints fixed to walls including stack clamp of GI flat 30mm wide 2mm thick fixed to wall with nail at spacing of 1m center to center, fixed in repairs complete all as specified and directed. |
| 40 | PVC SWR bends any radius 75 mm bore provided with access door fixed in repairs, complete all as specified and as directed. |
| 41 | PVC SWR bends any radius 110 mm bore fixed in repairs, complete all as specified and as directed. |
| 42 | PVC (SWR) branch piece of 75 mm bore pipe, single (single Y) equal or unequal ordinary or inverted (spigot or socket type) provided with access door fixed in repairs, complete all as specified and directed. |
| 43 | PVC (SWR) branch piece of 110 mm bore pipe, single (single Y) equal or unequal ordinary or inverted (spigot or socket type) provided with access door fixed in repairs, complete all as specified and directed. |
| 44 | PVC (SWR) branch piece of 75 mm bore pipe, double (double Y) equal or unequal ordinary or inverted (spigot or socket type) provided with access door fixed in repairs, complete all as specified and directed. |
| 45 | PVC (SWR) branch piece, double (double Y) equal or unequal ordinary or inverted of 110 mm bore pipe fixed in repairs, complete all as specified and directed. |
| 46 | PVC (SWR) junction single, (Single T) equal or unequal of 75mm bore provided with access door fixed in repairs, complete all as specified and directed. |
| 47 | PVC (SWR) junction single, (Single T) equal or unequal of 110mm bore provided with access door fixed in repairs, complete all as specified and directed. |
| 48 | PVC SWR reducer 110mm to 75 mm complete all as specified and as directed, |
| 49 | PVC SWR vent cowl 75 mm complete all as specified and as directed. |
| 50 | PVC (SWR) 75 mm dia floor trap plain with grating including jointing with solvent cement fixed in repairs, all as specified and directed |
| 51 | 600 X 450 mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated beads screws and cup washers fixed in repairs, complete all as specified and as directed. |
| 52 | TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia complete all as specified and directed. |
| 53 | TMT bars, 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally or hooping for column, hooking ends and binding with and including mild steel wire(annealed) not less than 0.90mm dia as in stirrups, complete all as specified and directed. |
| 54 | Plain cement concrete type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) as in chajja complete all as specified and directed. |
| 55 | Reinforced cement concrete nominal mix Type B-1 1:2:4 (20mm graded crushed stone aggregates) for cooking platform ,Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed. |
| 56 | Form work to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for rough finished surfaces of concrete, complete all as specified and as directed. |
| 57 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, complete all as specified and directed. |
| 58 | Formwork (rough finished flat surface) to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges complete all as specified and directed. |
| 59 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and directed. |
| 60 | Removing excavated material exc. 250 m but n exc 500 mtrs and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed. |
| 61 | Concrete bed to drain pipes 1:3:6 type C-2 (Using 40mm graded crushed stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested for 150mm internal dia of pipe, complete all as specified and directed. |
| 62 | Reinforced concrete pipes 150mm dia, class NP3, laid and jointed with collars, complete all as specified and directed. |
| 63 | PCC 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 64 | 15mm thick cement plaster rendering in CM 1:4 on fair faces of brick or concrete surfaces including mixing of WPC admixture as per manufacturer's instruction & finishing the surface even and smooth without using extra cement, complete all as specified.(Note:- WPC admixture shall be measured and paid separately) |
| 65 | Supply only liquid water proofing compound. |
| 66 | Reinforced cement concrete 1:2:4, B-1 (Using 20mm graded stone agg) as in manhole covers slab/shelves etc including necessary form work for fair finished surfaces complete all as specified and directed.Note:- Steel reinforcement shall be measured and paid seperately under relevant item |
| 67 | Construction of Soakage well of size 1.8m dia and 3.0m depth in any type of soil, foundation in pcc 1:3:6 wall of honeycombed brick masonary, RCC cover slab in M-25 filling with brick bats. Drg No CE/TD/1202/03 Sheet 1/2 & 2/2 complete all as specified and directed. |
| 68 | Dismantling asbestos cement (corrugated, semi corrugated) sheets including ridges as in roof covering, complete all as speciified and directed. |
| 69 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) of any type and any thickness including cover fillets/GI grid framework complete all as specified and directed. |
| 70 | Dismantling timber scantling 40 sqcm and over in section, as in any position, complete all as specified and directed. |
| 71 | Structural steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastening and heavy brackets (Beam, tee, angle, channel or hollow steel section) including distance pieces, cleats etc confirming to Fe-410-W (Gde-E-250) quality B complete all as specified and directed. |
| 72 | Pre-painted galvalume aluminum zinc coating GI based corrugated sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 73 | Pre-painted galvalume aluminum zinc coating GI based plain sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 74 | False ceiling of grid of galvanzed steel tee/ angle (power coated ) of grid size 600x600mm as comprising of main and secondry tee ( weight not less than 240gm /RM) and wall perimeter angle (weight of section not less than 217gm/RM) all around of walls suspended with 4mm GI wire @ 1200mm c/c of ceiling by fasteners of adjustable guide hanger including clips/MS fitments to hold the panels insert of any type including 4mm thick Asbestos fibre designer ceiling boards size 595x595mm fixed in position all as directed. |
| 75 | GI frame work with size of grid 605mm x 605mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre intermediate channel 0.9mm thick having two equal flanges of 15mm each web of 45mm suspended from soffit at approx 900mm c/c with GI cleat and steel expansion fasteners with and including celing section (n.exc 1.2m length) of 0.55mm thickness having kruled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 centre to centre with support of Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and including 12mm thick Gypsum board fixed to flat surface in GI metal frame work complete all as specified and directed. |
| 76 | Applying 3mm thick wall care putty on ceiling surfaces complete all as specified and directed. |
| 77 | Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed. |
| 78 | Taking down wall panelling including similar works in any position complete all as specified and as directed. |
| 79 | PVC wall lining/panelling consisting of 5mm thick plain colour pvc sheet inclusive of solvent cement and fixing at site on pvc frame including 5mm thick pvc sheet filet of width 5mm to make pvc frame as per manufacturers instruction and drawings, complete all as specified and directed. |
| 80 | 10mm thick heavy duty PVC fluted panel of any color any design inclusive solvent cement and fixing at on wall/frame as specification in interior/exterior wall complete all as specified and directed. |
| 81 | Texture cement stone cladding thickness of 8mm of standard weight 9.6Kg/Sqm of fire resistance as per BS-476 part-IV, moisture resistant tested as per IS-14862-2000 of thermal conductivity of 0.0872 W/m-K at mean temperature of25 degree of any colour finished with one coat of primer and two coats of exterior emulsion paint of external wall complete all as per manufacturer's direction complete all as specified and directed, |
| 82 | Vitrified ceramic tiles (Light shade) 10mm thick (square /rectangular) polished, area of each tile n.exceeding 0.36 sqm laid as in floors, set and jointed in neat cement slurry and pointed in white/coloured cement to match with shade of tiles including 15mm thick screed bed in cement and sand mortar 1:4, complete all as specified and directed. |
| 83 | Description all as per Item No 82 above, but in skirting/dado over and including 10mm thick rendering in CM 1:4. |
| 84 | Demolition of brick work or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework, complete all as specified and as directed. |
| 85 | Brick work with sub class 'B' bricks , straight or curved on plan exc. 6 mtr mean radius built in CM 1:6 complete all as specified and directed. |
| 86 | Taking down cement plaster from brick or stone walls incl racking out joints hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 87 | Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed. |
| 88 | Providing cement concrete type B-1, 1:2:4 ( using 20mm graded crushed stone aggregate), 50 mm thick as in plinth protection laid in bays not exceeding 2 Sqm each and finishing even and fair with 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between the walling and plinth protection, filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand ( all by weight), complete all as specified and as directed. |
| 89 | 25mm PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floor finished even and fair complete all as specified and directed, |
| 90 | Roughening surfaces of old concrete floors by picking,sweeping clean and washing down with water to remove dust etc and brushing with neat cement slurry using cement at 3kg/sqm complete all as specified and as directed. |
| 91 | 20-25 mm thick machine cut kota stone slab as in flooring, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over with mirror cut polishing 100mm wide marble patti/border all around and including 15mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed.Note:-(Size of Kota Stone slab shall be 53 cm x 53 cm). |
| 92 | Description all as per Item No 91 above, but in skirting/dado over and including 10mm thick plaster in CM 1:4 including mirror cut polishing complete all as specified and directed. |
| 93 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) of size n. exc 1.5 Sqm each complete all as specified and as directed. |
| 94 | Figured glass sheet, 3mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed. |
| 95 | Steel windows/ventilator (Box type) factory made glass/glazed shutter, (glass panes shutter shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 . |
| 96 | Machine pressed precast concrete interlocking paver block of any shape and size, ISI marked (IS:15658-2006) 60mm thick, M-35 grade , in paths and hardstanding,with grey cement and coloured pigment, laid tightly over and joints filled with dry sand. (Size, shape, colour and pattern as approved by GE) complete all as specified and directed. |
| 97 | Plain Cement Concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in coping and eadges of path, roof kerb including weathering, slightly rounded or chamfered angle and throating, necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. |
| 98 | Removing excavated materials exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |
| 99 | Removing excavated materials exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |