| 1 | Electrical fault attending on call basis with necessary testing equipment i.e megger, clamp multimeter and necessary tools and tackles, testing, checking for necessary restoration of electrical faults, replacement of minor spare parts / accessories, etc. i/c cleaning of LT panel/TP DB/Pump Panel/Fan & filter of Free Cooling system by blower i/c tightening of necessary connections etc. complete as required. |
| 2 | Replacement of the following faulty / damaged spares i/c connection, testing, checking, commissioning etc. complete as reqd. |
| 3 | a ) DP MCB (40-63 A) (M/s L&T or SS make) |
| 4 | b) TPN MCB ( 40-63 A) (M/s L&T or SS make) |
| 5 | c ) 63 Amp FP Isolator |
| 6 | d)9 W LED Bulb ( M/s Havells or SS Make) |
| 7 | e) 63 TPN SFU in open execution with 3 nos HRC fuse (M/s L&T or S/S make) |
| 8 | f) 63 A HRC Fuse |
| 9 | g) 150 A stud type connector |
| 10 | h) 63 A rewireable type porcelin kitkat fuse |
| 11 | i) S/F of 200A A rewireable type porcelin kitkat fuse |
| 12 | j) 20 W LED tube with PVC batten type( M/s Phillips or S S Make) |
| 13 | k)three pole 18A power contractor ( MNX 18) |
| 14 | l) Dial type timer |
| 15 | m) 63 TP MCB |
| 16 | n) 4 way MCB box |
| 17 | r) S/F of 100A Neutral link |
| 18 | Supply and fixing the following size of lugs/ socket/ reducer for replacement of burnt out cable leads i/c necessary crimping arrangement etc complete as required. |
| 19 | a) 6 sqmm copper |
| 20 | b ) 10 sqmm copper |
| 21 | c) 16 sq mm copper |
| 22 | d) 6 sq mm Allumunium |
| 23 | e) 16 sq mm Allumunium |
| 24 | f ) 25 sq mm Allumunium |
| 25 | g) 35 sq mm Allumunium |
| 26 | Supplying , drawing/ laying of following sizes 1.1 KV grade PVC insulated copper conductor flexible cable etc. as reqd. |
| 27 | a) 16 Sqmm |
| 28 | b) 10 sqmm |
| 29 | c) 6 sqmm |
| 30 | d) 4 sqmm |
| 31 | Supplying installation, testing and commissioning of 1 no. heavy duty axial flow type fan 300 mm sweep , 1350 RPM suitable single phase 220V AC supply including clamps, fixing bolts, sundry materials complete as reqd. |
| 32 | Supplying and laying following sizes pvc insulated copper conductor un armoured cable of 1.1 KV grade i/c / socketing the lead, making connection as reqd. |
| 33 | a) 4 core 10 sq mm |
| 34 | Replacement of 100 A FP, 415 V, on load change over switch in sheet steel en closure after dismantling the damaged 250A FP changeover switch, burnt out cable etc i/c making hole on the panel, fixing the same on the panel i/c making connection , testing, checking etc. as reqd. (M/s L&T or S S Make) |
| 35 | Supplying and fixing following items . |
| 36 | a) 10 sqmm flexible copper cable |
| 37 | b) 100A FP terminal block |
| 38 | c) 10 sqmm copper socket |
| 39 | d) 35 sqmm Aluminium socket |
| 40 | Supplying and Fixing of 12V/24V - 10A SMPS Automotive Lead Acid Battery Charger with Analog Display (I/P : 150V AC to 285V AC) battery charger with trickle charging facility etc as required |
| 41 | Repairing/servicing the self starter at work shop by throughly checking of armature field coils, pinion & gear, Solenoid switch ( Starter relay) i/c. commutator and brushes, test run etc complete as required. up to 40 KVA |
| 42 | Suppling of 12V 150AH Lead Acid cell maintenance free battery complete with initial charging for starting of DEA set as reqd. (M/s Exide) |
| 43 | Suppling of 12V 130AH Lead Acid cell maintenance free battery complete with initial charging for starting of DEA set as reqd. (M/s Exide) |
| 44 | Attending Emergency fault ,testing,checking of electrical connections,meggaring & testing of Pump condition and finding the fault etc. complete as required. |
| 45 | Withdrawal of the Submersible pump set along with G.I. Pipe and cable from the existing bore well with necessary tools and tackles and arrangement of scaffolding after necessary disconnection of delivery pipe line and electrical connections etc complete as reqd. |
| 46 | Supplying of 50 mm dia. Heavy duty GI pipe i/c cutting threading complete as reqd. (Supreme or similar superior make). |
| 47 | Lowering, re-installation of the submersible pump set along with G.I. Pipe and cable in the existing borewell with necessary tools and tackles and arrangement of scaffolding and necessary re-connection of delivery pipe line , cable jointing and electrical connections for commissioning the pump set and restoration of water supply testing commisioning etc as required |
| 48 | Rewinding of 3 hp Submersible/Centrifugal motor i/c dismantling from site transportation to work shop, refixing and testing commissioning etc as required |
| 49 | Rewinding of 5 hp Submersible/Centrifugal motor i/c dismantling from site transportation to work shop, refixing and testing commissioning etc as required |
| 50 | Rewinding of 7.5 hp Submersible/Centrifugal motor i/c dismantling from site transportation to work shop, refixing and testing commissioning etc as required |
| 51 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class VC conduit as required. |
| 52 | a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 53 | b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 54 | c) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 55 | d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 56 | S/F SP MCB ( C series ) ( 5-32 A) conections i/c removing of old mcb if required so etc as required Please Enable Macros to View BoQ information |