| 1 | Supply of materials |
| 2 | Supply of Kiosk panel single door 600x600x300 IP 66 with stand of 60cm height |
| 3 | Supply of 12 way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator). |
| 4 | Supply of 40A rating, double pole (single phase and neutral) 240 V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 5 | Supply of 32A rating, 240/ 415 V, 10 kA, \\"C\\" curve, Single pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. |
| 6 | Supply of 16A rating, 240/ 415 V, 10kA, \\"C\\" curve,single pole miniature circuit breaker suitable forinductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc.as required. |
| 7 | Supply of 6A rating, 240/ 415 V, 10kA, \\"C\\" curve, Single pole miniature circuit breaker suitable forinductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc.as required. |
| 8 | Supply of one run Copper Conductor, XLPE Insulated,Thermoplastic Tape Inner Sheathed, Armoured andExtruded PVC Type Outer Sheathed power cable of 1.1 kVgrade (2XFY) of following size as per IS-7098(part 1) 2011.(cost for 1 Meter) 4 core X 4 Sq.mm 2XWY |
| 9 | Supply of Wiring for circuit/ submain wiring alongwith earth wirewith the following sizes of FRLS PVC insulated, 650V,copper conductor, single core cable in surface / recessedwith 20/25/32mm medium class, ISI marked, PVCconduit/casing and capping as required. 2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 10 | Supply of Wiring for circuit/ submain wiring alongwith earth wirewith the following sizes of FRLS PVC insulated, 650V,copper conductor, single core cable in surface / recessedwith 20/25/32mm medium class, ISI marked, PVCconduit/casing and capping as required. 2x2.5 sq.mm + 1x2.5 sq.mm earth |
| 11 | Supply of flexible copper cable, solid/ stranded copperconductor, PVC insulated, core laid up, PVC tape/ PVCextruded innersheathed for multicore cables, unarmoured,extruded PVC type ST2 sheathed 650/ 1100 V grade as perIS 7098(part 1) 1988. 3 core X 1.5 Sq.mm 2YY(cost for 1 Meter) |
| 12 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit / casing and capping, with modular switch, modular plate, suitable PVC / GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 13 | Supply of Digital multifunction time switch, 2M,din rail mount (suitable for MCB DB), 24Hrs, LCD withbackground lighting, 10A 1SPDT/2SPDT contact, 230VAC,1phase, Automatic Summer/winter, ROM storage.Two channel Make: Legrand, Schneider, Siemens, L&T |
| 14 | Supply of contactor,2 pole,12 AModel:MNX 12 of LK or equivalent |
| 15 | Supply of Integral LED street light luminaries, 70w,230VAC, 1Ф, 50Hz comprising of epoxy power coated hsg, enclosed with glass cover in frame. Suitable for 50mm OD pipe, Ingress Protection IP66, luminus efficiency>= 110 lm/Watt, integral driver, inbuilt surgesuppressor of 10 kV or above with supporting bracket/chain with complete accessories. |
| 16 | Supplying of Weather proof junction box (IP 65) surface mounted 4 Way with connector |
| 17 | Supplying of following size Modular Socket on existing modular switch box/cover including connections etc. as required.2 Module, 5 Pin, 6A |
| 18 | Supplying of following Modular base & cover plate on existing modular PVC/GI box.6 Module |
| 19 | Supplying of following size Modular Socket onexisting modular switch box/cover including connections etc.as required.2 Module, 5 Pin, 16A |
| 20 | Supplying of following size Modular Switch onexisting modular switch box/cover including connections etc.as required.1 Module, 1 Way, 16A |
| 21 | Supply of wall fan 230V, 50HZ, 90W, 2000-2100 rpm, 72-80 CMM, 40-45dbnoise level, variable speed with ocsillation completeaccessories as required.300 mm wall fan |
| 22 | Supplying of end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required ) 4sqmm |
| 23 | Supplying of end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required ) 1.5 sqmm |
| 24 | Supply and installation of 8-10W, 1700-2100 lumen output, 230V AC, single phase, 50 Hz, IP 20, 1200 mm length T8 LED tube with extruded aluminium/ polycarbonate body, inbuilt driver complete with pre wired, CRCA batten etc. as required. 18-20W LED/ CRCA batten Nos. 150.00 338.00 LIGHT FITTINGS, FANS AND AIR CONDITIONING UNITS8-10W LED/ CRCA batten |
| 25 | Supply of 10SWG Cu wire and 0.50 meter below ground level/surface for conductor earth electrode including connection/termination with copper lug etc.. As required.(Cost for 1 meter) |
| 26 | Supply of earthing with GI earth pipe 4.5m long,40mm dia including accessories and providing maisonry enclosure with cover plate having locking arrangement and water pipe etc with charcol coke and salt as required. |
| 27 | Supply of 25mm Dia Galvanized round pipe with 5mm thickness including excavation, laying of pipe and refilling the trench etc. as required . |
| 28 | Supply of selector switch 10A with 2 number of switching position electrical life 1lakh cycles per pole |
| 29 | Installation charges |
| 30 | Fixing of Kiosk panel single door 800x800x300 IP 66 suitably with anchor bolts upon an RCC block of 400 mm height |
| 31 | Installation of 12 way, single pole and neutral(SPN), sheet steel, 230V MCB double door distributionboard on surface complete with 100A fully insulated tinnedcopper bus bar, srouded neutral bar earth bar,interconnections, powder coated including earthing etc. asrequired. (without MCB/ RCCB/ Isolator). |
| 32 | Installation of following rating, double pole (singlephase and neutral),40A, 240 V, RCCB, having a sensitivitycurrent of 30 mA in the existing MCB DB complete withconnections, testing and commissioning etc. as required. |
| 33 | Fixing of 16A rating, 240/ 415 V, 10kA, \\"C\\" curve,single pole miniature circuit breaker suitable forinductive load of following single poles in the existing MCB DBcomplete with connections, testing and commissioning etc.as required. |
| 34 | Fixing of 6A rating, 240/ 415 V, 10kA, \\"C\\" curve, Single pole miniature circuit breaker suitable forinductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc.as required. |
| 35 | Fixing of 32A rating, 240/ 415 V, 10kA, \\"C\\" curve, Single pole miniature circuit breaker suitable forinductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc.as required. |
| 36 | Laying of one run Copper Conductor, XLPE Insulated,Thermoplastic Tape Inner Sheathed, Armoured andExtruded PVC Type Outer Sheathed power cable of 1.1 kVgrade (2XFY) of following size as per IS-7098(part 1) 2011.(cost for 1 Meter) 4 core X 4 Sq.mm 2XWY |
| 37 | Laying of circuit/ submain wiring alongwith earth wirewith the following sizes of FRLS PVC insulated, 650V,copper conductor, single core cable in surface / recessedwith 20/25/32mm medium class, ISI marked, PVCconduit/casing and capping as required. 2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 38 | Laying of flexible copper cable, solid/ stranded copperconductor, PVC insulated, core laid up, PVC tape/ PVCextruded innersheathed for multicore cables, unarmoured,extruded PVC type ST2 sheathed 650/ 1100 V grade as perIS 7098(part 1) 1988. 3 core X 1.5 Sq.mm 2YY(cost for 1 Meter) |
| 39 | Laying of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V,copper conductor, single core cable in surface / recessedwith 20/25/32mm medium class, ISI marked, PVCconduit/casing and capping as required. 2x2.5 sq.mm + 1x2.5 sq.mm earth |
| 40 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit / casing and capping, with modular switch, modular plate, suitable PVC / GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. |
| 41 | Fixing of Digital multifunction time switch, 2M,din rail mount (suitable for MCB DB), 24Hrs, LCD withbackground lighting, 10A 1SPDT/2SPDT contact, 230VAC,1phase, Automatic Summer/winter, ROM storage.Two channel Make: Legrand, Schneider, Siemens, L&T |
| 42 | Installation of of contactor,2 pole,32AModel:MNX L&T or equivalent |
| 43 | Intsallation of Weather proof junction box (IP 65)surface mounted 4 Way with connector |
| 44 | Installation of Integral LED street light luminaries, 70w,230VAC, 1Ф, 50Hz comprising of epoxy power coated hsg, enclosed with glass cover in frame. Suitable for 50mm OD pipe, Ingress Protection IP66, luminus efficiency>= 110 lm/Watt, integral driver, inbuilt surge suppressor of 10 kV or above with supporting bracket/chain with complete accessories. |
| 45 | Fixing of following size Modular Socket onexisting modular switch box/cover including connections etc.as required.2 Module, 5 Pin, 6A |
| 46 | Fixing of following Modular base & coverplate on existing modular PVC/GI box.6 Module |
| 47 | Fixing of following size Modular Socket onexisting modular switch box/cover including connections etc.as required.2 Module, 5 Pin, 16A |
| 48 | Fixing of following size Modular Switch onexisting modular switch box/cover including connections etc.as required.1 Module, 1 Way, 16A |
| 49 | Installation of wall fan 230V, 50HZ, 90W, 2000-2100 rpm, 72-80 CMM, 40-45dbnoise level, variable speed with ocsillation completeaccessories as required.300 mm wall fan |
| 50 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required ) 4sqmm |
| 51 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )1.5sq mm |
| 52 | Installation of 8-10W, 1700-2100 lumen output, 230V AC, single phase, 50 Hz, IP 20, 1200 mm length T8 LED tube with extruded aluminium/ polycarbonate body, inbuilt driver complete with pre wired, CRCA batten etc. as required. 18-20W LED/ CRCA batten Nos. 150.00 338.00 LIGHT FITTINGS, FANS AND AIR CONDITIONING UNITS8-10W LED/ CRCA batten |
| 53 | Installation of 10SWG Cu wire and 0.50 meter below ground level/surface for conductor earth electrode including connection/termination with copper lug etc.. As required.(Cost for 1 meter) |
| 54 | Installation of earthing with GI earth pipe 4.5m long,40mm dia including accessories and providing maisonry enclosure with cover plate having locking arrangement and water pipe etc with charcol coke and salt as required. |
| 55 | Laying of 25mm Dia Galvanized round pipe with 5mm thickness including excavation, laying of pipe and refilling the trench etc. as required . |
| 56 | Installation of selector switch 10A with 2 number of switching position electrical life 1lakh cycles per pole Please Enable Macros to View BoQ information |