| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. |
| 2 | Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thickness minimum 2 mm, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.FRLS PVC insulated copper conductor single core cable etc as required. |
| 4 | Group C |
| 5 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 6 | 2x1.5 Sq. mm. |
| 7 | 2x2.5 Sq. mm. |
| 8 | 2x4 Sq. mm. |
| 9 | 2x10 Sq. mm. |
| 10 | 4x4 Sq. mm. |
| 11 | Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. |
| 12 | 3x1.5 Sq. mm. |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- |
| 14 | 25 mm. dia |
| 15 | 50 mm. dia |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required |
| 17 | 5/6 amp Modular switch |
| 18 | 3 pin 5/6 amp socket outlet |
| 19 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. |
| 20 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 21 | Supplying and fixing following size/modules,G.I box alongwith modular base & cover for modular switches in recess etc.as required |
| 22 | 8 Module (125mmX125mm) |
| 23 | Supplying and fixing Ding Dong bell suitable for single phase, 230 volts, complete as required. |
| 24 | Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 25 | Single pole. Cat-A. |
| 26 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | 40 Amps |
| 28 | 63 Amps. Cat-A. |
| 29 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | 40 Amps. Cat-A. |
| 31 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 32 | 63 Amps. Cat-A. |
| 33 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- |
| 34 | Double door-6 way |
| 35 | Double door-12 way |
| 36 | Double door-16 way |
| 37 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 38 | 32 A- 100 A 18 KA |
| 39 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required.Exhaust Fan, Light duty, (Domestic) 300 mm sweep. |
| 40 | Exhaust Fan, Heavy duty, 300 mm sweep |
| 41 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 42 | Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. |
| 43 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run). |
| 44 | Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run). |
| 45 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. |
| 46 | Armoured cable 35 sq. mm (3.5 core) |
| 47 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. |
| 48 | Armoured cable 95 sq. mm (3.5 core) |
| 49 | Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required. |
| 50 | Armoured cable 95 sq. mm (3.5 core) |
| 51 | Providing, Installation, testing and commissioning of ceiling fan with two module modular step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required. |
| 52 | Ceiling Fan 1200 mm sweep, Category-A |
| 53 | Supplying and fixing surface mounting 2'x2' size LED solution suitable for surface application with the use of the latest technology 36 Watt (3360 lumens), 6500K made of CRCA housing and it should be compatible with specifications i.e. power factor ≥ 0.95, harmonic distortion ≤ 10% and efficacy ≥ 80 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz complete with all accessories, connections, testing and commissioning etc.as required with 5 years warranty.36 Watt LED, 2'x2' Panel |
| 54 | Providing and Fixing of 1200 mm X 300 mm LED fixture 36 W +/- 1W Surface mounted fixture with HET Plastic diffuser with CRCA Powder Coated housing having minimum system lumen efficacy 100lm/W with P.F.>0.95 with THD<10%. The LED with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700 K with CRI of minimum 80. The Input voltage range shall be 150V to 270V , 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 55 | LED Panel 4'x1' 36 watt Surface |
| 56 | Providing and Fixing of IP20 LED Surface mounted CRCA Powder Coated Box Type Channel with Pro LED Lamp Suitable for mounting 2 X 18 W LED Tube T8 type having minimum system efficacy of 100 lm/W, P.F.>0.95 with THD<10% ,CCT 6500 K,CRI 80,Surge Protection 2 Kv.The LED with Useful life of 50000 Hrs at L70 .The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 57 | LED fixture 2x18 Watt Surface Mounted 4 Feet Ultra Bright LED Tubelight |
| 58 | Providing and fixing of LED fixture 18Watt +/- 1W recess mounted having minimum system lumen efficacy of 100lm/W with with CRCA housing and PMMA diffuser with P.F. >0.95, THD<10%, CCT 5700K, CRI 80. The LED shall be tested with LM80-08 standard with useful life of 50000 hrs. at L70. The input voltage range shall be 150V as required complete with connections, testing etc. with 5 years warrenty period. |
| 59 | 18 Watt LED Surface panel |
| 60 | Providing and fixing LED Batten Light of IP40 Led fixture 20 W+/- 1W with Surface Mounted 4 Feet with Polycarbonate diffuser with Extruded aluminium housing having minimum system lumen output 1000 lumens and system lumen efficacy of 100 lm/W with P.F.>0.95 with THD<20% ,CRI 80 .The LED with Useful life of 50000 Hrs at L70 . The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80.The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 61 | LED Batten Light of IP40 20W |
| 62 | Providing and fixing of IP65 Bulkhead led fixture 10 W +/- 1 W Wall Mounted with minimum system lumen efficacy of 100 lm/W with Pressure Die Cast Aluminum housing, Polycarbonate Opal Diffuser and P.F.>0.95 with THD<10% ,CRI 80.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70 .The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K only with CRI of minimum 80.The Input voltage range shall be 140V to 280V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc.as required complete in all respects. |
| 63 | LED Bulk Head 10 Watt |
| 64 | Providing and fixing decorative LED mirror light having high quality design suitable for LED tube up to 10Watt (1000 lumen) 6500K and it should be compatible with specifications i.e. power factor ≥ 0.9, harmonic distortion ≤ 10% and efficacy ≥ 100 lumens per watt, CRI > 80, suitable for input voltage AC 220-240V, 50/60 Hz, complete with all accessories, connections, testing and commissioning etc. as required. |
| 65 | 10 Watt LED Mirror Light, 2 ft. |
| 66 | Supplying and fixing 45W LED street light made up of die cast aluminium housing with LED street optic LENS, offering uniform light distribution and individual LEDs with IP66 protection including connections, testing etc. as required complete in all respects with 5 years warranty. |
| 67 | 45W LED Street Light |
| 68 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board with color coted wire set, insulated vertical phase bus bar, neutral bar with shroud, earth war, cable type blanking plate and circuit identification lebel with provision for MCCB as incomer and SP/TP MCB as outgoing as required. (but without MCCB incomer ) |
| 69 | 6 Way (6+6+6), Vertical type, MCB DB, double door with MCCB Incomer |
| 70 | Supplying, Installation, Testing and Commissioning of cubical type, intdoor type,single door,Floor mounted, fixed type, free standing single front, dust proof & compartmentalized MainL.T.Panel made out of M.S. CRC Sheet 16G, Base Frame Angle 40X40X5mm duly painted with Siemens Grey Powder Coated Paint as per specification Approximate Size (H) 1800mm X (W) 1100mm X (D) 3000mm X (L) 300mm and Assembly Charges of 200A 4Strip Copper Busbar ( Vertical/Horizontal) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade , Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. and Assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB ./MCCB to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cables and Control Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. and the panel should be approved/tested from the CPRI lab and should be Comfirm I.S.64139 |
| 71 | MAIN PANEL : |
| 72 | INCOMING: |
| 73 | Main Incomer :-MCCB 2000A 4P 36KA TMR With O/L & S/C Protection -1 No.,Spreader Link MCCB 200A 4P-2 Nos., RHOM Ext.-1 No., Amp. Meter 96x96 MM-1 No., Volt Meter 96x96 MM-1 No., Ampere Selector Switch-1 No. Voltmeter Selector Switch-1 No. ,Current Transformer 3 Nos. Phase indicating lamp LED 03 Nos. Control SP 3 Nos. and terminal strip 01 No. |
| 74 | OUTGOING : |
| 75 | MCCB 100A 4P 25KA TMR With O/L & S/C Protection-4 No.,Spreader Link MCCB 100A 4P-4 Nos. |
| 76 | The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc, |
| 77 | Make:-OEM fulfilling the eligibility criteria as specified in CPWD for E.I. work. Please Enable Macros to View BoQ information |