| 1 | Repairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead.;With cement mortar 1:4 (1 cement : 4 fine sand) |
| 2 | Removing old loose bottom or side cover of RCC slab beam columns etc. rubbing surface of concrete steel using wire brush and applying 2 coats of Alkaline rust converting primer (Feovert) after a waiting time of 6 hrs between coats and then applying another anti corrosive protective coating system ) for reinforcement bars (IPNet-RB) Conforms to IS-2770 Part-1 (Pull out Test) ASTM-3963-86 (Adhesion Test) and then applying concrete penetrating corrosion inhibitor (EPCO-KP100) and applying bonding new to old concrete (Epibond) Conforms to ASTM-C-882-87 and plastering on the fresh bond coat with Polymer Modified Mortar (Monobond) with 20mm C.M 1:3 and finishing coat of 6mm C.P 1:3 (1 Cement : 3 Sand ) incl. cost of transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent. |
| 3 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete. |
| 4 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 5 | Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade. |
| 6 | Waterproofing of sunken slabs toilet blocks terraces on slabs under brickbats roofs watertanks. Cleaning the surface and filling cracks (if any) applying EPCO ACR wherever necessary Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent |
| 7 | UPVC ONLY DOOR FRAME:-;Providing & fixing Upvc Door Frame Yashashri make or equivalent made out of Upvc extruded multi cavity frame of 60 mm x 60mm x 2mm wall thickness. Frame is reinforced with G.I. Channel & welded in corners with Average weight 0.80 kg per running mtr. These frames are tested by using BS 2782 & DIN 53459 test methods. |
| 8 | 20 MM DOOR SHUTTER:-;Providing & fixing 20 mm door shutter Yashashri make or equivalent made by using 20mm x 155mm x 1.2mm upvc multi-cavity section and boarder of 30mm x 40mm x 2.5mm Upvc multi cavity section. The corners are joined by inserting polymetric corners & hardware used for fixing the door shutter is stainless steel hinges & S. S. handle & S.S. tower bolt. The average weight of 20mm door shutter is 4.60kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods. |
| 9 | Providing and fixing anodised aluminium shutters in accordance with the specification annexed herewith including transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Adjustable louvered windows.;Figured glass |
| 10 | Removing and refixing of door/ window shutters paneled or paneled and glazed including replacing of existing hionges chiseling etc complete as directed by Engineer- in charge;Above 1 Sq.m area |
| 11 | Providing and fixing M.S. tower bolts (barrel type) with necessary screws etc. complete;250 x 10 mm |
| 12 | Providing and fixing M.S. handles with necessary screws etc. complete.;125 mm |
| 13 | Providing and fixing 150 mm. bright finished brass floor door stopper with rubber cushion screws etc. to suit shutter thickness complete. |
| 14 | Providing and fixing bright finished brass door latch with necessary screws etc complete;250 x 16 x 5 mm |
| 15 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993;15mm nominal bore |
| 16 | Providing and fixing NICKEL chrome plated copper alloy Fancy long body bib cock with wall flance Jaquar make or equivalent. Confirming to IS 8931;1993;15mm nominal bore |
| 17 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.;500 lit. capacity |
| 18 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 19 | Crack filler for plasters IPS cement sand screeds and non – structural cracks. Do Not open the cracks Clean the cracks so as to free them from oil dust loose particles etc. Moisten the surface with water Fill cracks with EPCO ACR using spatula or a putty knife. While applying avoid formation of cavity or bubbles. After filling allow the surface to dry for at least 24 hours. Apply in layers at 24 hours interval. If the depth of the crack is more than 10mm. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent. |
| 20 | An elastomeric cementitious waterproof coating for concrete and masonry.;Providing and applying on a well prepared vertical surface Masterseal 550EL of BASF make or equivalent elastomeric flexible two component polymers modified cementitious composite system that requires no addition of water at the site. The product shall be applied in minimum two coats to achieve total DFT of 1mm. The material shall be mixed and applied fully in accordance with the manufacturer's instructions. The product shall exhibit at least 40% elongation at ambient & 30% elongation in under water condition with tensile strength greater then 20 Kg/cm2. The product shall resist 1.5 bars pressure when tested as per DIN 1048 at 2mm DFT. When applied at 2mm DFT elastomeric coating shall be able to bridge crack up to 0.5mm width. All scaffolding ladders supporting materials etc. complete. Rates shall be inclusive of all labour materials tools and plant etc. complete. |
| 21 | Providing and and laying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson Somany Kajaria (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigment etc. complete;Dark Shades |
| 22 | Engaging labour / wet sweeper for performing work as directed by engineer in charge. |
| 23 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).;25 mm outer dia CPVC pipe |
| 24 | Providing, erecting and dismantling of scaffolding of width 1.20mts made up of 100mm dia wooden ballies with 38mm thick wooden planks platforms of width 1.20mts at every 2.50mts vertical spacing and for a total vertical height upto 9.00mts. from ground level etc. complete. Please Enable Macros to View BoQ information |