| 1 | Fitting and providing one HT stay for 11kV pole, including digging and back filling pit in ordinary soil. |
| 2 | Transferring LT single phase 2/3 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete. |
| 3 | Transferring LT single phase 4/5 wire OH line to newly erected HT/LT pole including dismantling existing cross arm and insulators, refitting the same on the new pole, binding etc. complete. |
| 4 | Disconnecting and lowering down the single phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work. |
| 5 | Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole including disconnecting and reconnecting wires. |
| 6 | Disconnecting and lowering down the three phase WP service connection with guy wire from the OH line and reconnecting the same after completing the line work. |
| 7 | Additional rate for excavation of one Pit for HT Pole/HT Stay in Laterite. |
| 8 | Fitting and providing one strut using HT PSC pole including digging and back filling pit in ordinary soil. |
| 9 | Labour charges for loading HT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle) |
| 10 | Pole numbering using printed Aluminium sheets of 22 SWG having size 20 x 12 cm or painting the surface of line supports where numbers are to be inscribed, pole numbers shall be painted in circular / rectangular background, using approved quality anti algal yellow paint in two coat after scraping and cleaning the surface at a height of 2.5 metre above ground level. the numbers and letters should be in black synthetic enamel paint. The size of the number should be at least 2cm in height x 1.5 cm in width. including cost of paint. |
| 11 | Fitting and providing on HT Fly stay for 11 kV pole using HT PSC pole including digging and back filling pits in ordinary soil, drawing suffcient length of GI earth leads to the ground for earthing (Excluding provision of earthing). |
| 12 | Fitting one Additional 2.4m/3m Channel cross arm (100x50x6mm), in existing 11KV DP including Conveyance of materials. |
| 13 | Fitting one set AB switch on existing DP, giving connection and drawing sufficient of GI earthing leads to the ground for earthing, excluding provision of earthing |
| 14 | Drilling hole of various sizes on existing Channel/Cross arm |
| 15 | Fitting one LT 2 line cross arm on HT or LT existing poles including fitting insulators and binding the same with LT line. |
| 16 | Providing one Earth using GI earth pipe of size 38.1mm dia, 2.5m length including separate pit (0.45x0.45x2.5m) at a minimum distance of 1.5m away from the pole/structure and maintaining standard distance between different earth pipes in ordinary soil & backfilling. |
| 17 | Striginging of one km 3 PH 11KV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) after fitting insulators, binding conductors to pin insulators using suitable tie and anchoring with wedge type anchoring clamps including cutting and removing tree branches wherever necessary excluding cut point works |
| 18 | Providing one earth using GI earth pipe of size 38.1mm dia, 2.5m length including digging separate pit (0.45x0.45x2.5m) at standard distance (1.5m) away from the pole/structure in ordinary soil & backfilling the pit with 15cm alternate layer of charcol, salt and sand up to 90cm from the bottom. including the cost of 20kg salt, 25kg charcol, excluding supply of earth pipe. |
| 19 | Providing one Coil Earth using No.8 GI-earth wire (50mm dia, 115 turns) including digging separate pit (0.45x0.45x1.5m) at standard distance away from the pole/structure in ordinary soil & backfilling. |
| 20 | Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading&unloading charges. |
| 21 | Additional rate for providing one disc set, PG clamp etc. complete, on any type of HT pole for making cut point |
| 22 | Fitting and erecting one HT Double Pole Structure using PSC pole in position including fitting 2 channel cross arms, digging and back filling pit in ordinary soil, drawing suffcient length of GI earthing leads through all cross arms to the ground for earthing (excluding provision of earthing). |
| 23 | Fitting 5 channel cross arms, AB switch, DO fuse, LA(Ord), HT & LT connections upto OH lines, etc. on existing DP structure, Fixing distribution box/provision for one set 3No.) of LT fuses, drawing suffcient length of GI earthing leads to the ground for earthing, excluding provision of earthing & mounting of Transformer on poles. |
| 24 | Fitting one Additional V cross arm in existing single pole including conveyance of materials |
| 25 | Fitting one additional Fuse unit and giving connection from Transformer to fuse and Distribution box to LT OH line. |
| 26 | Dismantling (without damage) one LT PSC/RCC pole after disconnecting stays, Strut etc. attached thereon and stacking the same. |
| 27 | Fitting and erecting one HT PSC Single pole in position, including fitting cross arm, digging and back filling pit in ordinary soil (as per standards), drawing suffcient length of GI esrthing leads from F clamp through V cross arm to the ground for earthing (excluding provision of earthing). |
| 28 | Installing one DTR Meter with box (normal size 40x25x100cm) on existing poles including fixing of 3 CTs on bus bar, laying and termination of control cable using proper lugs, fixing of meters, capacitors, control fuses and giving the complete connections including conveyance of materials. |
| 29 | Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame, 2 runs of 40 x 6 MS flat for horizontal brasing and grills with MS rod 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation |
| 30 | Cleaning and leveling of transformer yard/RMU, spreading 40mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a crub wall of height 20cm above ground and 10cm below level including cost of all materials and charges for conveying, spreading, consolidating etc. |
| 31 | Erecting one 100KVA Transformer to existing DP and giving connections, including loading from TMR/SRS/other stacking place & unloading at site but excluding cost for transporting transformer. |
| 32 | Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVA Transfomer / Ring Main Units excluding loading & unloading charges Please Enable Macros to View BoQ information |