| 1 | Repair and Renovation of Technical Service Department Office Room and Veranda area at FACT CD, Ambalamedu, Kochi. |
| 2 | Dismantling and removing doors with or without ventilators including removal of shutters, hinges, holdfast and all other fittings and stacking materials as per deptl. instructions |
| 3 | Labour charges for dismantling carefully the existing ceiling /partitions with AC sheets, Plywood / Hardboard /wood etc and stacking them for reuse as per deptl.instructions. |
| 4 | Providing and laying glazed vitrified floor tiles(GVT) with approved brand and size 1200x600mm or nearest available size (thickness to be specified by manufacturerer with water absorption lessthan 0.08% and cofirming to IS 15622 and fixing floor tiles with cement based high polymer modified quick set tile adhessive(Water based)confirming to IS 15477 in average 3mm thickness and grouting the joints of flooring tiles having joint of 3mm width using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10kg of hardner and 0.20kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer in charge. |
| 5 | Providing and fixing vitrified floor tiles with water absorption less than 0.08% and conforming to IS :15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades of any size as approved by Engineer-in-Charge for skirting (height 10cm) to walls over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm with adequate joint spacing of 3mm followed by grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge, excluding cost of cement. |
| 6 | Scrapping old paint and Cleaning all surface by Jet Pressure pump of fresh water, removing all fungus, vegetation, Algae & Opening crack by grinder in 'V' shape up to 3mm, cleaning, 1 coat primer & filling all cracks by crack seal, finishing , Cleaning the surround surface etc. as permanufacturer specification. |
| 7 | Painting one coat of priming coat on plastered surface (interior) with approved quality cement primer after cleaning the surface including all cost of materials, labour etc. |
| 8 | Painting two coats with ready mixed plastic emulsion paint of approved quality and colour specified over the priming coat already done and paid separately after cleaning the surface well. |
| 9 | Supplying and fixing anodized Aluminium frame work of extruded sections and approved brand / manufacturer including mitering the joints, fixing the frame work with necessary screws, drilling holes in floors/walls, providing plugs for fixing screws, finishing the sides of packing between frame work and walls with plaster of Paris, cost of timber packing if necessary, Rubber lining for air tightness, providing corner cleats etc.complete as per standard practice for glazed Doors, Windows, Partitions, Ventilators etc.including hinges ,pivots, tower bolts, fixtures etc.complete(All Aluminum fittings measured in Kg) |
| 10 | Glazing the Aluminium frame work of windows with 3 mm or nearest thick plain glass panes and anodized Aluminium approved brand beadings, with EPDM / NEOPRINE weather seals, gaskets of EPDM or PVC etc and screws as per standard practice at all levels (Measurement for overall area of doors / windows / ventilators) |
| 11 | Glazing/Panelling the Aluminium frame work of doors/other areas with 5.50 mm glass and 4 mm thick hylam sheets (40% hylam sheet aproximate) and powder coated Aluminium approved brand beadings, with EPDM / NEOPRINE weather seals, gaskets of EPDM or PVC etc and screws as per standard practice at all levels (Measurement for overall area of doors/other area) |
| 12 | Providing cup board shutters with approved quality wooden series Aluminium profiles having show case frame of size 66x32.5x0.83 mm,shutter frame of size 41.90x23x0.98 mm, Intermediate frame of size 32x32x0.80 mm (if required) having necessary shutters & partitions (If required) as per requirement, covered with 3 mm hylam sheet inclusive of SS Handles, 75 mm SS hinges, Magnetic latches , necessary cleat angles,rubber beedings & corners with all fixtures in SS screws etc complete as per directions at site |
| 13 | Polishing the existing mosaic floor with suitable mosaic grinder/grinding stone |
| 14 | Collecting , Conveying and disposal spoil earth, debris, dismantled or waste materials by manual/ mechanical means,including loading, transporting , unloading to approved areas for filling, spreading in layers as per directions of Eng-in-charge . (20%deduction will be made if measured loose in lorries & from stack).-For an average lead of 2 KM. |
| 15 | Providing man Mazdoor for labour assistance for emergency works which are not covered in the Schedule of work. Please Enable Macros to View BoQ information |