| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 2 | Group 'A' |
| 3 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd. |
| 4 | 3 x 1.5 Sq.mm.. |
| 5 | 3 x 4 Sq.mm.. |
| 6 | Supply and drawing of telephone wire of 2 pair 0.50 mm dia copper conductor FRLS PVC insulated unsheathed twisted wire jelly filled in existing / surface concealed conduit as reqd. including numbering and connecting the wires at both the ends. |
| 7 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 8 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 9 | 25 mm |
| 10 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 amps switch |
| 12 | 15/16 amp switch |
| 13 | 3 pin 5/6 amp socket outlet |
| 14 | 6 pin 15/16 amp socket outlet |
| 15 | Telephone socket outlet |
| 16 | TV antenna socket outlet |
| 17 | Bell push |
| 18 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 19 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 20 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 21 | 6 Module (200mmX75mm) |
| 22 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 23 | 6 Module |
| 24 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 25 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 26 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 27 | Supplying and fixing following size/ modules, GI box in recess etc as required. |
| 28 | 6 Module (200mmX75mm) |
| 29 | Supply, Installation, testing & commissioning of AC ceiling fan of following sweeps, aluminium die cast body , copper wound, double bearing, less 70 watts 220 volts 50 Hz without regulator I/c wiring the down rods of standard length up to 30 cm with 1.5 sq.mm. PVC insulated copper conductor single core cable etc as reqd. ( ISI marked.) |
| 30 | 1200 mm Make_Bajaj Kassel/or approved Make. |
| 31 | Supply, fixing, testing and commissioning domestic fresh air ventilation fan, 150 mm dia,plastic body,1Ǿ AC power supply,50 Hz complete as required. |
| 32 | Supply,Installation,Testing and commissioning of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete as requiired. |
| 33 | LED light fitting (Integrated) 20 watt with AL-Batten, =>125Lm/w, Make Crompton(Bright linea) or approved Make. |
| 34 | Wall bracket fitting for B_22 with LED bulb (make crompton or equivalent approved make) |
| 35 | LED Ceiling Light 6 watt FR-plastic_housing (round/square shape), Make Crompton-Royal Rimless-R (Cat No. LCRP-06-CDL) or equivalent approved make |
| 36 | LED Ceiling Light 12 watt FR-plastic_housing (round/square shape), Make Crompton-Royal Rimless-R (Cat No. LCRP-10-CDL) or equivalent approved make |
| 37 | Locating fault in wiring rectifying removing & restoring supply the same & making good the damages etc as reqd. |
| 38 | Dismantling the old MS/ PVC conduit pipe of all sizes from surface/recessed & making good the damages I/c filling the holes of the surface and depositing the same as reqd. |
| 39 | Dismantling the old wood batten/PVC casing capping of all sizes from surface & making good the damages I/c filling the holes of the surface and depositing the same as reqd. |
| 40 | Dismantling of switch board/MS/PVC boxes of any size up to 250x300 mm on surface/ recessed including making good and painting with enamel paint etc as reqd |
| 41 | Dismantling, disconnecting old damaged unserviceable fitting/ ceiling fan/ bulkhead fitting with bracket etc. as reqd. and depositing in sectional store. Please Enable Macros to View BoQ information |