| 1 | SH A: Fire Fighting systemSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : |
| 2 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 3 | Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. |
| 4 | M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 5 | Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 6 | 2850 lpm at 88 m Head |
| 7 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) |
| 8 | Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. |
| 9 | Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. |
| 10 | M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 11 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 12 | 2850 lpm at 88 m Head |
| 13 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) |
| 14 | Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. |
| 15 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. |
| 16 | M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 17 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 18 | 180 lpm at 88 m Head |
| 19 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) |
| 20 | Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 |
| 21 | Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. |
| 22 | M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. |
| 23 | Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 24 | 900 lpm at 35 m Head |
| 25 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required: |
| 26 | INCOMING 630A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-630 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 800Amps |
| 27 | OUTGOING(Note: All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch local/remote, auto/manual/OFF operation |
| 28 | JOCKEY PUMP |
| 29 | 125 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 30 | DIESEL ENGINE CONTROL |
| 31 | Control for diesel engine comprising - |
| 32 | Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indicationBattery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC AmmeterAll standard relays and accessories for automatic operation of diesel engineSYSTEM CONTROLLERDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 33 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 34 | 150 mm. Dia |
| 35 | 100 mm dia |
| 36 | 80 mm. Dia |
| 37 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: |
| 38 | 25 mm dia |
| 39 | 32 mm dia |
| 40 | 40 mm dia |
| 41 | 50 mm dia |
| 42 | 65 mm dia |
| 43 | 80 mm dia |
| 44 | 100 mm dia |
| 45 | 150 mm dia |
| 46 | 200 mm dia (wall thickness 6.3 mm) |
| 47 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 48 | Single headed Stainless steel |
| 49 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 50 | Single headed Stainless steel |
| 51 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 52 | 50mm dia |
| 53 | 65 mm dia |
| 54 | 80 mm dia |
| 55 | 100 mm dia |
| 56 | 150 mm dia |
| 57 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : |
| 58 | 150mm dia |
| 59 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 60 | Stainless Steel (Grade 304) |
| 61 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 62 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. |
| 63 | 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 |
| 64 | 20 mm nominal internal dia gun metal globe valve & nozzle. |
| 65 | Drum and brackets for fixing the equipmets on wall. |
| 66 | Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 67 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : |
| 68 | Stainless Steel (Grade 304) |
| 69 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : |
| 70 | 2 way-100 mm dia M.S. Pipe |
| 71 | 4 way - 150 mm dia M.S. Pipe |
| 72 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 73 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : |
| 74 | Pendent Sprinkler |
| 75 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 76 | 50mm dia |
| 77 | 65mm dia |
| 78 | 80mm dia |
| 79 | 100mm dia |
| 80 | 150mm dia |
| 81 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. |
| 82 | 1000mm |
| 83 | Air pressure vessel for Fire Pump :- Providing and fixing double flanged vertical air vessel fabricated from 6 mm M.S. plate with dished ends from 8 mm M.S. plate, outside with one coat of primer and two coats of synthetic enamel paint of approved shade, complete with pressure gauges and all other required accessories to operate commonly main fire pump, Diesel Fire pumps and Jockey pumps at drop of pressure automatically at required pressure setting complete as required and as per enclosed specification. |
| 84 | For Fire Pump: |
| 85 | Dia. : 450mm |
| 86 | Height of shell : 2000mm |
| 87 | Working pressure :12 Kg/Sq.cm |
| 88 | Test Pressure : 16 Kg/Sq.cm |
| 89 | Supplying & fixing of hose cabinet of size 900 mm x 600 mm x 300 mm made of 16 swg MS sheet with 4 mm thick glazed glass thick doors i/c necessary locking arrangement suitable to accommodate, 2 Nos. 15 mtr. long Hose pipe, 1 No. branch pipe, with proper bricks platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for Tarrace hydrant, complete etc as reqd. |
| 90 | Supplying & fixing of hose cabinet of size 750 mm x 600 mm x 250 mm made of 16 swg MS sheet with 4 mm thick glazed glass thick doors i/c necessary locking arrangement suitable to accommodate, 2 Nos. 15 mtr. long Hose pipe, 1 No. branch pipe, with proper bricks platform & duly painted with Post office red externally and white internally with synthetic enamel paint complete in all respect, for Tarrace hydrant, complete etc as reqd. |
| 91 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 92 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : |
| 93 | 100 mm dia |
| 94 | 150 mm dia |
| 95 | 200mm dia |
| 96 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 97 | 100mm dia |
| 98 | 150mm dia |
| 99 | Providing & fixing of Pressure gauge in M.S. pipe line including connection etc as required. |
| 100 | Supplying, Installation, Testing and Commissioning of fixing of following dia. Gun metal gate valve (Screwed type) on the existing pipeline, including testing & Commissioning etc. complete as required.. |
| 101 | 50 mm dia |
| 102 | SH B Fire Alarm SystemSupplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required- 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Announcement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt, 30 AH each sealed maintenance free batteries -1 set. |
| 103 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 104 | 10 Zone |
| 105 | Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. |
| 106 | Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 107 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. |
| 108 | Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 109 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 110 | SH C : Public Address SystemSupplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 111 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 112 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 113 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. |
| 114 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. |
| 115 | speaker cable Two pair, 2-core, 1.5 sqmm |
| 116 | Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 117 | Providing & fixing following sided Architectural hanging / wall mounted non toxic, non-radio active maintaince free self glowing sinages direct fixed on wall / ceiling comprising of 2 mm thick (each side) alminium based photo luminescent safety signages high intensity luminous properties with ultra violet protection layer sheet i/c printed graphics symbols & written message etc. (in Hindi / English) fixed with fish wire/steel chain complete etc as reqd |
| 118 | Single side |
| 119 | Double side |
| 120 | Dismantaling existing various type of Fire Fighting Accessories having different size and type of pipes, valves, pumps, electric cables, sprinklers, hose reels etc i/c disconnections etc complete as required. |
| 121 | Dismantaling existing variouse type of Fire Alarm and PA System Accessories having different size and type of electric cables, panels, RI, isolator, control module etc i/c disconnections etc complete as required. |
| 122 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 123 | 25 mm dia |
| 124 | Fabricating,Supplying, Installation, Testing and Commissioning of Indoor type double door compartmentlised cubical type (IP 54) Fire Fighting Pump panel of suitable size not less than 300 mm deep made out of CRCA sheet steel 1.6 mm thick CRCA sheet powder coated Havells Gray of approved shade after 7 tank treatment process, hinged double door,totally enclosed, dust,vermin and weather proof with locking arrangement duly compartmentalised having 4 strip TPN Aluminium busbar duly PVC sleeved suitable for 415V 3 phase 4 wire 50 Hz A C supply, with cable alleys, detachable cable terminating plates at the bottom/top, end termination,sign writing, danger notice plate.The panel having bottom support suitable extended 'C' channel of size 700mm x 700 mm x 250mm base frame along with 4 legs(Min. 600 mm) grouted in the foundation and having following switch gears, instruments and accessories mounted inside the feeder Pillar i/c connection, interconnection of switch gears,proper gasketing,adequate ventilation arrangement, C.C.foundation of suitable size etc. complete as required as per CPWD specification and as per approval of Engineer in charge(Face Area not less than 1 Sq.mtr.) (For terrace pump) |
| 125 | Incoming :- |
| 126 | 40A TPN MCB 10KA |
| 127 | TPN aluminium bus bars of 100 AMP rating - 1 set |
| 128 | Metering |
| 129 | DIGITAL VOLTMETER - 1 No. |
| 130 | LED/phase indicating lamps (RYB) with MCB control - 3 Set |
| 131 | Outgoing :- |
| 132 | 7.5HP DOL 1W+1S STARTER :-2NOS |
| 133 | 32A TP MCB 10KA - 2 Nos. |
| 134 | 18A TP POWER CONTACTOR - 2 Nos. |
| 135 | 9-15A OVER LOAD RELAY - 2 Nos. |
| 136 | ON, OFF INDICATION LAMP - 4 Nos. |
| 137 | START, STOP PUSH BUTTON - 4 Nos. |
| 138 | AUTO/MANUAL SELECTER SWITCH- 2 Nos. |
| 139 | SINGLE PHASING PREVENTER - 2 Nos. |
| 140 | OTHERS |
| 141 | Suitable Star Delta Starter for above fire fighting pump With ON/OFF Push button,L/R Selector switch & LED Indicating lamp refer to the Type-2 Cordination chart - 2 Nos. |
| 142 | GI Earth strip 20 x 3 mm size full width of the panel with earth stud at both sides - 1 set |
| 143 | Incoming/Outgoing complete Sign writing - 1 job |
| 144 | Danger notice plate - 1 No. |
| 145 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (40 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 146 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 147 | Supplying and Laying of following size XLPE insulated PVC outer sheathed armoured cable with aluminium Conductor suitable for rated voltage of 1100 Volts ISI marked conforming to IS : 7098-1988 with upto date amendments i/c laying in following way, connection complete etc. as reqd. |
| 148 | 3.5 X 120 Sq.mm ( laying in pipe) |
| 149 | 3.5 X 120 Sq.mm ( On surface) |
| 150 | 3.5 X 70 Sq.mm ( cable tray) |
| 151 | 4 X 25 Sq.mm ( cable tray) |
| 152 | 4 x 25 Sq.mm (On surface) |
| 153 | 4 x 16 Sq.mm (Cably tray) |
| 154 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 155 | 3½ X 70 sq. mm (38mm) |
| 156 | 3½ X 120 sq. mm (45mm) |
| 157 | 4 X 25 sq. mm (28mm) |
| 158 | 4 X 16 sq. mm (28mm) |
| 159 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 160 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 161 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 162 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 163 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required. |
| 164 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 165 | 225 mm width X 50 mm depth X 1.6 mm thickness |
| 166 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm) |
| 167 | 18- 22 Watt |
| 168 | SITC of heavy duty exhaust fan 300 mm sweep 900 RPM with louvers in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 169 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 170 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 171 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 172 | Group C |
| 173 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 174 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 175 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 176 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 177 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 178 | 12 way , Double door |
| 179 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 180 | Single pole |
| 181 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 182 | SITC of 400 mm cabin / wall fan with all accessories on the existing wall with the help of fastener i/c connection etc. complete as reqd. |
| 183 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 184 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 185 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape. |
| 186 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc. |
| 187 | SH E: Credit dismantling & credit old existing unserviceable items |
| 188 | Assorted size MS pipe |
| 189 | Assorted size insulated cables and wires |
| 190 | Hydrants |
| 191 | Assorted size Sluice Valve 100/150/200 mm |
| 192 | Assorted size N.R.V 50/65/80/100/150 mm |
| 193 | Assorted size Butterfly valve 50/65/80/100/150 mm |
| 194 | Conventional panel of Fire Alarm with accessories |
| 195 | Detectors |
| 196 | Hose Reel drum |
| 197 | Assorted size Control valve |
| 198 | Sprinklers |
| 199 | Air Vessel 250/450 |
| 200 | MS Box |
| 201 | Jockey Pump (Considering 5% of New pump) |
| 202 | Fire pump panel with accessories (Considering 5% of New pump) |
| 203 | Electric driven Main Fire Pump (Considering 5% of New pump) |
| 204 | Diesel Driven Pump (Considering 5% of New pump) |
| 205 | Terrace Pump (Considering 5% of New pump) Please Enable Macros to View BoQ information |