| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(a) Group C |
| 2 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 3 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 5 | (d) 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 6 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.(a) 20 mm |
| 7 | (b) 25 mm |
| 8 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 10 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.6.1) 1 or 2 Module (75 mmX75 mm) |
| 11 | 6.2) 6 Module (200mmX75mm) |
| 12 | 6.3) 12 Module (200 mmX150 mm) |
| 13 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 15/16 A switch |
| 14 | (b) 6 pin 15/16 A socket outlet |
| 15 | (c) Telephone socket outlet |
| 16 | (d) CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568. 2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. |
| 17 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(a) 8 way (4 + 24), Double door |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 16 way, Double door |
| 19 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole |
| 20 | (b) 63 Amp. DP MCB |
| 21 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board / MCB DB including drilling holes, making connections, etc. as required.11.1) 100 A, 16 KA, TPMCCB |
| 22 | Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required |
| 23 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 24 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 25 | LED Panel light 2x2 ft. (System lumen efficacy =105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5°C to 40°C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1. 5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0. 50 mm) (a) 36 watt |
| 26 | Supplying, Installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2. 5 KV with Short & Open circuit protection, THD < 10%, P. F. =0. 95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1. 5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim a) 12 -15 watt |
| 27 | Brush Less Direct Current (BLDC) MotorSupplying, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as required.(a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 28 | Supplying, Installation, Testing and Commissioning of 400 mm Sweep wall Fan suitable for 230 V 50 Hz Ac Supply complete with all accessories on existing wall etc. complete as required. |
| 29 | Supplying, Installation, Testing and Commissioning of following size of Sweep with following RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the same, connection, testing, commissioning etc. as reqd. (a) 300 mm sweep 900 RPM |
| 30 | (b) 380 mm sweep 900 RPM |
| 31 | Supplying, Installation, Testing and commissioning of non-metallic Fresh Air Fan with louvers shutters of following specification on the existing wall opening etc. complete as required.a) Sweep : 250 mm b) Wattage : not exceeding 45 Wc) Air Delivery : not less than 500 CMH |
| 32 | Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum/copper conductor armoured power cable of 1.1 KV grade on surface/wall/ in pipe/open duct etc. as required.(a) 4 x 25 sq.mm Al. Cable |
| 33 | (b) 3.5 x 50 sq.mm Al. Cable |
| 34 | (c ) 4x16 sq. mm Copper Conductor |
| 35 | SH-II (Air-Conditioners)Supply, Installation, testing and commissioning of Double Skin (Forward Curved DIDW Fan) Treated Fresh Air Unit will be comprising as per Follow : -Factory built floor mounted double skin type horizontal TFA of 45 mm thick panels injected with 40kg / cum density, CFC free PUF insulation with frame work consisting of Hollow Extruded Aluminum Profile consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection molding machine, unit base frame heavy gauge G.I., complete with blower section with blower imported DIDW centrifugal Forward curved blower suitable for static pressure of 50 mm WG static pressure, cooling coil section with Imported special grade copper tube (tubes thickness not less than 0.5mm) DX Coil of 8 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters with Non-woven Synthetic type supported with wire mesh, Fins Material & Thickness 0.15 mm Special grade aluminum alloy -sine wave and staggered pattern, Efficiency of Pre Filter(EU-4) 90 % down to 10 micron, belt drive package with TEFC drive motor Protection IP 55 of efficiency class IE2 suitable for 415 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive.22.1) 2500 CFM Static- 125 MMWG with Hepa filters |
| 36 | Supply, Installing, testing and commissioning Dry Scrubber Unit complete with DIDW Fan Section with following components:-1. Casing - Shall be double skin made of 0.60 mm galvanized preplasticized/powder coated sheet on outside and 0.60 mm GI sheet inside with PUF foam of 36 kg/m3 density insulation in between sheets to make 23 mm thick panels.2. Pre Filter Section with Wire Mesh SS Filters for Coarse Particle Removal.3. Electrostatic Precipitator Section - Electrostatic section shall be made of 16 gauge galvanised sheet, high bake epoxy powder coated, SS Spiked ionizers to create high voltage DC field, aluminium collector plates which should be alternatively charged positive and negative with large collecting area with deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% in single pass as per ASHRAE/DOP test method. Electrostatic Precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. Collector cell should be of permanent type and incorporate slide out facility for easy removal for cleaning. Power supplies shall be 100% solid state. 4. Fan Section with DIDW Backward Curved having 710mm Dia DW type. 1082 RPM, 89 db noise level Fan having following capacity @ specified SP and should be complete with suitable TEFC Induction Motor and Belt Drive arrangements. 23.1) 2600 CFM 70 MMswg |
| 37 | 23.2) 1200 CFM 70 MMswg |
| 38 | Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. 24.1) Thickness 0.63 mm sheet |
| 39 | 24.2) Thickness 0.80 mm sheet |
| 40 | Outdoor units:-Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/ Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor (s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit (s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39° C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity <40 kWr ISEER 5. 4, Capacity > 40 and <70 ISEER 5. 5, Capacity > 70 ISEER 5. 6 for ECSBC Building) For Cooling or Heating or Both. I/C pre fabricated stands for ODU's with vibration pads.25.1) 10 HP to 12 HP |
| 41 | 25.2) 14 HP to 22 HP |
| 42 | INDOOR UNIT Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 ° C DB and 19 ° C WB temperature. (Make will be same as of Outdoor) 26.1) 1. 0 TR |
| 43 | 26.2) 1. 6 TR |
| 44 | 26.3) 2. 0 TR |
| 45 | 26.4) 3.6 0 TR |
| 46 | 26.5) 4.1 0 TR |
| 47 | Supplying, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs (a)Indoor Units |
| 48 | SITC of PVC Drain Water Piping complete with fittings (elbows, tees, reducers, sockets etc.), supports, jointing and any other item required to make the system complete. Nominal Diameters of Pipes in mm as indicated below:28.1) 25 mm ( with 6 mm Insulation) |
| 49 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 29.1) 38. 1 mm dia (OD) (Hard drawn) with tube thickness 1. 62 mm |
| 50 | 29.2) 28. 58 mm dia (OD) (Hard drawn) with tube thickness 1. 2 mm |
| 51 | 29.3) 22. 2 mm dia (OD) (Hard drawn) with tube thickness 1. 2 mm |
| 52 | 29.4) 19 mm dia (OD) (Hard drawn) with tube thickness 1. 2 mm |
| 53 | 29.5) 12. 7 mm dia (OD) (Soft drawn) with tube thickness 1. 2 mm |
| 54 | 29.6) 12. 7 mm dia (OD) (Soft drawn) with tube thickness 1. 2 mm |
| 55 | 29.7) 9. 5 mm dia (OD) (Soft drawn) with tube thickness 1. 2 mm |
| 56 | 29.8) 6. 4 mm dia (OD) (Soft drawn) with tube thickness 1. 2 mm |
| 57 | Providing & fixing control cum transmission wiring of 2 core x 1.5 sqmm copper in suitable conduits between indoor units and outdoor units and indoor units and remote controllers. |
| 58 | Providing and charging of R410 refrigerant complet as per site requirement in new VRV Unit i/c vacuumizing, nitrogen testing of existing system complete as required. |
| 59 | Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 60 | Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete in confirmation to SMACNA/IS and as per specifications complete etc. as required. |
| 61 | SH-III (UPS)Online UPS- Input supply: Three Phase, Output supply: Three Phase Supplying, installation, Testing & Commissioning of of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 deg C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swappable(allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS)system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter(3 Level) with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be < 5% at 50 %load. (The required LC (inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1), however UPSshall be suitable to take load at 0.7 lagging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC :3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage:3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120%for 10 mins, Sine wave output. Non condensing, noise level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery overcharging, output over current, short circuit protection, battery deep discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved asper EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI)-type UPS. Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge. Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost) |
| 62 | This system must provide a means for logging and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise Level65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED ) to display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d)Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f)Temperature: STS, Inverter, PFC. g) Event Logging &Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i)Mains Mode of Operation /Battery Mode of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms: Mains Failure, Battery Low Alarm, UPS Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short-circuit, Over Temperature. The UPS should have QR code which should contain drawing, test report OEM manual, Geo-Tag of manufacturing location etc.(a) 40 KVA (Each Power module shall be ≤ 10 KVA) |
| 63 | SH-IV (CCTV System)Supplying Installation Testing and Commissioning of 8 MP IP IR Dome Camera having following specifications and features etc :-1) Type of Camera: Dome Camera2) Image Sensor: 1/2.8\\" or better progressive Scan CMOS get color image even at night condition3) Signal System: PAL/NTSC4) Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better 5) Imaging: 1/3s to 1/30000s, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both.7) Signal to Noise Ratio: > 50 dB8) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source- Inbuilt IR LED's with effective distance upto 50 Mtrs integrated IR and 30 meter for colour view in night.9) Video Compression (Minimum): H.265 or better, H.265, H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.72310) Wide Dynamic Range: WDR (120db or more)11) Digital Noise Reduction: DNR (2D/3D) On/Off12) Streaming: Triple streaming, configurable13) Video Streaming & Frame Rates: Triple streaming, configurable Main stream: 8MP (3840 × 2160)@20 fps, Sub streams: 4MP (2688×1520)@25/30 fps & D1@25/30 fps;14) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser15) Profile Management: User configuration import, export16) Security: User Authentication, Water Marking17) On board Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.18) Recording Management: Format SD, overwrite, storage management, video to NAS device,19) Edge Analytics: Tripwire, Intrusion, Motion Detection20) Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection |
| 64 | 21) Alarm Support: It should have 1/1 Alarm In/ Out Port22) Audio Support: It should have 1x Built-In Mic and 1/1 Audio In/ Out Port for external Mic. and Speaker (As per site requirement) with G.711U/A/ G.711Mu/ AAC/ G.726 audio compression23) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast, 24) System Capability: ONVIF25) VMS: Camera shall support open source VMS 26) Cyber Security: trusted boot, AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade.27) Ethernet: 1 RJ 45 10/100 Ethernet port28) Power Input: The camera should support simultaneous dual power input - 12 VDC (via power adapter) and PoE-to ensure continuous operation in the event of a failure in one power source.29) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE30) Enclosure: IP67 weather proof, IK1031) Operating Condition: Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)32) IR life: 40000 hours or higher33) Video Bit rate: 32 KBPS - 8 MBPS or better34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS(a) 8 MP (3840 × 2160)@20 fps or better IP IR 2.7mm ~13.5mm Motorized lens, Vari Focal Dome Camera, Angle of View: H: 104°–32°, V: 54°–18°, D: 125°–36° or better |
| 65 | Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.(a) 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. |
| 66 | Supplying and fixing 24U Rack with 4 inch Castor wheels and front brake Floor Standing Rack with Main Frame Pillar of 1. 25mm Powder Coated CRCA Sheet with removable side panels, L- Shape adjustable Vertical Mounting Rail of 2mm with U'Marking completely knocked-down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 5nos two line cable entry/exit provision at top and bottom with rubber protection, Front door 5mm Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 67 | LED DisplaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with3840x2160 resolution or better, USB playback, Bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+,brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V):170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc.as required.(a) 55 inch or larger |
| 68 | Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H. 265 or better, H. 264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G. 711U/A, G. 711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage.5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3. 0, 2xUSB2. 0) 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses, with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm |
| 69 | 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20, 000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection.32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics a) 34) Analytics by NVR: Perimeter protection and face recognation 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32 (36), 2nd screen: 1/4/8/9/16 |
| 70 | Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3. 5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. (a) 8TB (Terabytes) |
| 71 | Earthing with G. I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 Meter long etc. with charcoal/ coke and salt as required. |
| 72 | Providing and fixing 6 SWG dia G. I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 73 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1. 1 KV grade as required. a) 3½ X 50 sq. mm (35mm) |
| 74 | b) 4 X 16 sq. mm (28mm) |
| 75 | c) 4 X 25 sq. mm (28mm) |
| 76 | Fabrication, Designing, Supplying, installation, testing and commissioning of outdoor type cubical type Electrical feeder panel of suitable size fabricated from workshop with IP 54 Protection having depth not less than 400 mm suitable for 415 V 3 phase 4 wires, 50 Hz, AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates including cleaning and finishing complete with 7 tank prepaint process painting with powder coating in siemens grey or approved shed, having extensible type TP & N Aluminium Alloy bus bars of capacity 1.5 times of Main Incomer rating of high conductivity, DMC/SMC bus bar supports with short circuit with stand capacity of 31 MVA for 1 second bottom base channel of MS Section not less than 50mm X 50mm X 5mm thick, entire panel shall have a common G.I earth bar of size 25mm X 6mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of aluminium bus bars and control wiring with 1.5 sqmm FRLS PVC insulated copper conductor single core cable, cable alleys, terminal block for wires & cable, gland plates etc as required. Incoming – a) 125 A FP 25KA MCCB with adjustable thermal magnetic OL/SC protection (Ics=Icu=100%) with spreader link and extended rotary handle – 1 no b) R/Y/B Phase Indication Lamp(LED)-1Set c) MCB SP 2A 10 KA for protection-3 Nos d) CT Class 1, 15 VA 200/5 - 3 nos. e)Multifunction Metre Outgoing- a) 63A FP 16-18 kA MCCB with adjustable thermal magnetic OL/SC protection (Ics=Icu=100%) with spreader link and extended rotary handle – 5 nos |
| 77 | Dismantling of the existing electrical accessories such as wiring, conduit, boxes, switches, sockets, DB's, fans, fittings, ac units etc. including credit of the same under buy back etc. complete as reqd. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail