| 1 | Disconnecting the unserviceable transformer with connected accessories and transporting to the MES store yard. |
| 2 | Supply, fixing, testing and commissioning of transformer, step-down, 11/0.433KVA complete, outdoor/indoor, copper wound capacity 500 KVA complete all as specified and as directed |
| 3 | Supply, fixing, testing and commissioning of transformer, step-down, 11/0.433KVA complete, outdoor/indoor, copper wound capacity 250 KVA complete all as specified and as directed |
| 4 | Supply, fixing, testing and commissioning of transformer, step-down, 11/0.433KVA complete, outdoor/indoor, copper wound capacity 160 KVA complete all as specified and as directed |
| 5 | Supply, fixing, testing and commissioning of transformer, step-down, 11/0.433KVA complete, outdoor/indoor, copper wound capacity 315 KVA complete all as specified and as directed |
| 6 | Note for Item No. 02 to 05(i) No load voltage ratio-11/0.433 KV(ii) Nos of phase- Three(iii) Type of cooling- Oil Natural Air Natural(iv) Frequency-50 Hz(v) Vector group-DYN 11(vi) Two earthing terminals for body earthing.(vii) Oil level gauge indicating oil level minimum and maximum.(viii) Lifting lugs.(ix) Rating and terminal marking plates.(x) Dehydrating breathing device which would not permit ingress of moisture, rain water and insects.(xi) Drain-cum-sampling valve (3/4\\" nominal size thread) preferably steel with plug(xii) Thermometer pocket (for transformers of rating above 25 KVA).(xiii) Oil filling hole (1-1/4\\" Nominal size thread) with cover(xiv) Connection- Delta/Star(xv) Temperature rise in oil-40 deg Centigrade(xvi) Temperature rise in winding- 45 deg Centigrade.(xvii) Material winding-Copper wound |
| 7 | (xviii) High voltage/low voltage-Bushing with box.(xix) Service -Outdoor Type (xx) Neutral- Internally connected with earth lead and bush. (xxi) Tapping range and Tapping methods:- As per IS 1180 -2014, Off load, +-7.5% in steps of +-2.5 % for variation of HV (xxii) Maximum losses of transformer shall be energy efficiency level-2 as per IS-1180(Part-I):-2014 with amendment no. 1,2,3 & 4 (xxiii) Other accessories as per IS 1180(Part-I):-2014 & 2026 (xxiv) The permissible temperature rise in transformer winding shall not be exceed 40 deg C when measured by thermometer method. (xxv) No load current shall not exceed 2 % of full load current when transformer is energized at rated voltage and frequency. (xxvi) The transformer must be BIS marked & BEE Two Star Labelled.(xx) 150mm dia oil temperature indicator with alarm & trip contacts.(xxi) Double float Bucholtz relay with two sets of contacts and isolating valves.(xxii) 150mm dia winding temperature indicator with alarm & trip contacts.(xxvi) Marshalling box. (xxvii) Provision of necessary wheels and channel |
| 8 | M&L for taking down of old unserviceable copper earthing complete all as specified and directed. |
| 9 | M & L Earthing complete with Copper earth plate electrode of size 600mmX600mmx3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to copper strip of size 20x3 mm by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also be included for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 15mm dia light grade GI protection pipe for earth lead etc., complete all as specified and directed. |
| 10 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for laying of pipes, cables, etc. getting out soft/loose soil all as specified and directed |
| 11 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed |
| 12 | Removing excavated soil to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed |
| 13 | M & L for Riddled sand filling in trenches for cushioning of HT/LT UG cables punning after filling complete as specified and as directed Note: Punned thickness shall only be measured and paid |
| 14 | Supplying and laying unreinforced precast concrete cable cover, class LV, type 1, flat, size 250 x 150 x 40 mm, complete all as specified and directed |
| 15 | M&L for taking down of old unserviceable XLPE insulated, 11000 volts HT cable of sizes 95 sqmm to 300 sqmm all as specified and directed. |
| 16 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 300 sq mm 3 core complete all as specified and directed. |
| 17 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 185 sq mm 3 core complete all as specified and directed. |
| 18 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 150 sq mm 3 core complete all as specified and directed. |
| 19 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed. |
| 20 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed. |
| 21 | Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm all as specified and directed. |
| 22 | Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm all as specified and directed. |
| 23 | M&L for taking down of old unserviceable lightening arrestor, GOD all as specified and directed. |
| 24 | Supply and fix lightning arrestor HT 11 kv 10 KA expulsion type complete with all fittings,transmission class, discharge capacity 65 kilo amp suitable for 11000 volts complete all as specified and directed.. |
| 25 | M & L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size , for HT 25 x 20 cm size and dismantling old one all as specified and directed.. |
| 26 | S & F Synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purposes as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of sizes 2 m x 1 m all as specified and directed. |
| 27 | M & L for Cross arms , bracing, supports, clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint and dismantling old one all as specified and directed. |
| 28 | M & L for Switch air break gang operated 11 KV, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps complete all as specified and directed |
| 29 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in hard dense soil and removing surplus soil to a distance n exc 50m & making good surface complete all as specified and directed |
| 30 | M&L for plain cement concrete 1:2:4, type B2 (40 mm graded stone aggregate) filling and mass concrete in foundation, post holes etc complete all as spd and as directed. |
| 31 | Dismantling posts or struts( wood steel or RCC) any section including taking out embedded portion in concrete, brick work masonry etc and making good disturbed ground complete all as specified & as directed. |
| 32 | Dismantling fencing wire mesh any type in existing chain link fencing complete all as specified |
| 33 | Supply only Chain link MS galvanised fencing, any size or type complete all as specifed and as directed. |
| 34 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed. |
| 35 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long but n exc 10cm long and dia of neck 16 to 20mm complete all as spd and as directed by Engineer in charge |
| 36 | S&F Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not lessthan 0.9mm dia or securing with clips Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) complete all as spd and as directed by Engineer in charge |
| 37 | S & F in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts ,posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 incl curved or ramped portions of hand rails to required shape or figure (curved, ramped or scroll portions only measured) complete all as spd and as directed by Engineer in charge |
| 38 | Preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer completed all as specified and directed Please Enable Macros to View BoQ information |