| 1 | Supply , installation , testing and commissioning of microprocessor based 1 loop capacity analouge addressable fire alarm control panel with minimum 80 characters LCD display, 800 event plus, QWERTY keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spares capacity in each loop. Each loop shall have a capacity of minimum 300 analouge addressable device. The panel shall work in degrade mode in case of CPU failure. Four access levels, flash EPROM, 240 volts AC Power supply, automatic battery charger , 2 x 12 Volts , 7 AH sealed lead acid batteries . Designed to meet UL 864 10th edition - 1 loop control panel with single mode fiber card High speed network communication module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber.Model NFS-320 + HS NCM SF of Make Notifier/ Honeywel / Cease Fire/EDWARD/Siemens |
| 2 | Supply , installation , testing and commissioning of network control annuciator with 640 character display used to present event information from the network with alphanumeric QWERTY rubber keypad with tactile and audible feedback. Multiple passwords and access levels. Support digital voice command (DVC) for network audio application. UL/FM approved with single mode fiber card high spped network commucation module upto 25 KM (15.5 miles) between nodes using 9/125 micrometer single mode fiber as specified as directed by Engineer in Charge. Model NCA-2 ONYX + HS NCM SF Make Notifier Honeywell Cease Fire/EDWARD/Siemens/ Ravel |
| 3 | Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination photoelectirc/optical with base with self built intelligence , the detector should have group decision technology for faster responce & avoid false alarms, the detector shall have twin bi color LED for 360 degree viewing addressing shall be with user friendly roatary decimal switches designed to meet UL 268 7th edition as specified as directed by Engineer in Charge.Make Notifier Honeywell / Cease Fire/EDWARD/Siemens/Ravel |
| 4 | Supply , installation testing and commissioning of sounder cum strobe rated at 80 dBA @ 3m for audible and 115 cd flashing at 1Hz for visual indicaiton UL listed as specified as directed by Engineer in Charge.Make Notifier Honeywell or any other equivalent Make Notifier Honeywell / Cease Fire/EDWARD / Ravel/Siemens |
| 5 | Supply, installation and commissioning and testing of Addressable manual call point - Resettable type-with back box with binary coded address setting with status LED for 360 visibilty- IP 50 Rating as specified as directed by Engineer in Charge. Make Notifier Honeywell / Cease Fire/EDWARD/ Siemens/ Ravel |
| 6 | Supply, installation , testing and commissioning of addressable control module for sounder/strobes/sounder cum strobs . The control module shall provide supervised NAC output rated 24V DC 2A. The device shall have an LED whick blink in normal state and get steady on activation to monitor the health status of the device. Addressing shall be with user friendly rotary decimal switches, moduler shall be supplied with mounting plate from IEM for ease of installation and maint as specified as directed by Engineer in Charge. Make Notifier Honeywell/ Cease/ Fire/EDWARD/Siemens/Ravel |
| 7 | Supply , installation testing and commissioning isolator module for isolating short/dewired/loose circuit with automatic resetting arrangement isolator base can also proposed, however in that case needs to be considered with each detector & module , the device shall have an LED which sahll blink in normal stage and get steady on activation to monitor the health status of the device moduler shall be supplied with mounting plate from IEM for easeof installation and maint as specified as directed by Engineer in Charge. Make Notifier Honeywell or any other equivalent . i.e CEASE Fire/EDWARD/Siemens |
| 8 | Supply and fixing PVC insulated PVC unsheathed multistranded copper conductor cable of size FRLS cable 1.5 Sqmm 2 core as specified as directed by Engineer in Charge. |
| 9 | M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed (1:4) in CM laid and jointed with grey cement slurry mixed pigment to match the shade of slab including rubbing and polishing complete all as specified as directed by Engineer in Charge. |
| 10 | Supply and fixing switch and socket combination 5 Amp 3/5 Pin combined all as specified as directed by Engr-in- charge |
| 11 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of HT Cable and making good of disturbed surface to match with the existing surfaces by using new material i.e bitumen/PCC (1:3:6) type C-1 as specified as directed by Engineer in Charge. |
| 12 | Supply & laying 40 mm bore galvanised iron tubing light grade for protection of cable etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing as specified as directed by Engineer in Charge. |
| 13 | Supply and fixing connecting and testing optical fibre cable 6 core cat 6, Cable Type Armoured Loose Tube Jelly Filled (Multi-Tube), rodent resistant. Fiber Type Single Mode, 9 / 125, 250 micron primary coated buffers, Fiber Core As per Telecordia GR20, ITU-T G652D, IEC- 60793-2-50, TIA/EIA, 492-CAAB, No of Cores 12, Armouring Corrugated Steel Tape Armor, Cable Construction Type, BELLCORE GR 20 / IEC 794-1 - Loose tube Corrugated steel tape, (0.155mm Min)CSTA provided with FRP Rod as strength members, Outer Jacket Construction High density polyethylene, anti - termite, anti - rodent suitable, for direct burial application, @1310nm < = 0.35 dB/Km, @1500nm < = 0.20 dB/Km, Maximum Tensile Load >= 2670 N as specified as directed by Engineer in Charge. Make: D-link /Finolex/Legrand |
| 14 | Supply and laying HDPE 32mm dia pipe with 4 Kg/cm2 pressure with all fitting and accessories complete all as specified as directed by Engineer in Charge. |
| 15 | Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for manhole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified as directed by Engineer in Charge. |
| 16 | Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soil complete all as specified as directed by Engineer in Charge. |
| 17 | Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified as directed by Engineer in Charge. |
| 18 | Supply , installation , testing and commissioning Fire alarm control panel complying with BS EN 54/UL listing Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector and modules complete all as specified as directed by Engineer in Charge. |
| 19 | Supply, installation, testing and commissioning of Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 3500 mtr range complete all as specified as directed by Engineer in Charge. (Approved by LPCB/EN54) |
| 20 | S&F in replacement of Batteries DC , 12 V 7 AH lead acid duly initial charged complete all as specified as directed by Engineer in Charge. Make Exide/Amaron/Star Gold |
| 21 | Material & Labour for point wiring for one 15 Amp socket on Independent board controlled by one, one way switch complete with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn and including PVC conduit of suitable size , including all accessories like bend, tees, junction boxes etc. including 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including PVC terminal box of suitable size complete all as specified as directed by Engineer in Charge. |
| 22 | S&F Modular Switch one way one module 16 Amp complete all as specified as directed by Engineer in Charge. |
| 23 | Supply & Fixing Modular Socket outlet 3 pin, 6/16A, 3/5 pin two module complete all as specified as directed by Engineer in Charge. |
| 24 | Supply and fixing of stove enamelled black MS Conduit 20mm dia ISI marked on ceiling or recessed as required & repairing and making good the same disturbed surfaces and including taking down old unserviceable complete all as specified as directed by Engineer in Charge. |
| 25 | Supply and fix in repair PVC insulated PVC sheathed single core multistanded copper conductor cable of size 1.5 sqmm FRLS with PVC conduit of suitable size complete all as specified as directed by Engineer in Charge. |
| 26 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 2 core, 1100 Volts grade complete all as specified as directed by Engineer in Charge. |
| 27 | S&F of stainless steel mast of 38 to 40mm dia and length 3.0 mtr (approximate weidht 6.40Kg) fixed on roof slab/wall duly embedded in and including cement concrete (1:2:4) size 60x60x50cm complete for fixing mast inside the foundation complete all as specified as directed by Engineer in Charge. |
| 28 | S&F supporting tripods to fix lighting conductor or elevation mkasts to flat roofs including GI steel plate with bolts of dia 12mm , height 330mm , dimension of base plate 200 x 200mm inlcuding accessories complete all as specified as directed by Engineer in Charge. |
| 29 | S&F of Air termination with 5 spikes star pointed copper rod 15mm dia and 1500mm long and 100 micron copper bonded lightening conductor with base fixed in position on pole complete with clamp and nut bolts complete all as specified as directed by Engineer in Charge. |
| 30 | Supply and fix Copper earth strip of size 20 x 3 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block including taking down old strip complete all as specified as directed by Engineer in Charge. Please Enable Macros to View BoQ information |
| 31 | Supply and fix Copper earth strip of size 20 x 3 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block including taking down old strip complete all as specified as directed by Engineer in Charge. Please Enable Macros to View BoQ information |