| 1 | Taking down old unserviceable point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, regulators, sockets, light fittings etc. and making good to the disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 2 | Group C wiring for light point/Socket point/fan point//call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed PVC conduit with modular switch, modular plate, suitable GI box and earthing the point wih 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required.(a) For one light /fan point controlled by one; one way switch. |
| 3 | (b) All as per item No 2 above but for one ceiling fan/exhaust fan/ wall fan point controlled by one; one way switch. |
| 4 | (c) All as per item No 2 above but for one 3 pin 5 Amp socket out let controlled by one switch indep board. |
| 5 | All as per item No 2 but 15 Amp power point with 4 square cable complete all as specified and as directed. |
| 6 | Supply and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.(a) 15/16 Amp switch, 1 module |
| 7 | (b) 6 Pin 15/16A socket outlet |
| 8 | (c) 3/5 Pin 5/6A socket outlet |
| 9 | Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 10 | Supply and fixing 3 module (100mm x 75mm) size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 11 | Supply and fix ceiling rose 3 terminal 240 volts, 5 Amps complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Supply and fix LED tube light fitting 1X20 W, 4 feet long wall mounted anodized aluminum extruded heat shrink provided for efficient heat deception and interchangeable integrated electronic driver luminaries LED as light sources housing complete with all accessories including suitable lamp, internally prewired up with twin core twisted flexible copper cable of suitable size complete all as specified and directed by Engineer-in-charge.. |
| 13 | Supply and fixing basic all purpose surface and wall mounted LED batten 10 Watts with aluminium housing & integrated electronic driver, complete with all accessories including pre wired and connecting up with twin core twisted flexbile copper cable of suitable size complete all as specified and directed. |
| 14 | Supply and fixing LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 15 | Supply and fix in repairs 32 mm dia x 2 metre long GI pipe (light grade) bracket for mounting of street light fitting on pole including bending the pipe to the required shape, 2 Nos 40mm x3mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and paint etc complete all as specified and directed. |
| 16 | Wiring for circuit submain wiring alongwith earth wire with 2 x 4 sqmm + 1 x 4 sqmm earth wire of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit complete including taking down the existing unserviceable submain wiring all as specified and as directed. |
| 17 | Supply and fixing CRCA sheet steel, RAL 9003, powder coated vertical MCCB TPN DB double door, 12 way, IP 54 protection with provision for 3 pole and 4 pole MCCB as incomer and SP/TP MCBs as outgoings, conforms to IS 8623-1 &3, IEC 61439-1 & 3, IK 09, provided with insulated vertical phase bus-bars, neutral bars with shrouds, earth bars, sticknig saddles, cement spill protector, color coded interconnecting wire set, cable ties, blanking plates and circuit identification lable complete all as specified and as directed. |
| 18 | Supply and fixing, testing and commissioning in repairs 63A rating,Double pole (One phase & neutral), 230V, miniature circuit breaker (MCB), C-curve, 10 KA complete all as specified and directed. |
| 19 | Supply and fixing in repairs 5A to 32A rating, 240V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single pole in the MCB DB complete with connection ,testing and commissioning etc as required. |
| 20 | Supply and fixing 8 way double door, single pole and neutral, sheet steel, MCB distribution board, 240V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar din bar, inter connections, powder painted including earthing etc as required. |
| 21 | Material and labour for earthing with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 metre deep below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to copper strip 20 x3 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part - I connected to earthing test point including excavation / earth work in any type of strata PCC 1:3:6 type C1 including necessary formwork mould for fair and even surfaces including with precast RCC chamber cover slab (1:2:4) type B0 without GI protection pipe complete all as specified and directed by Engineer-in-Charge. |
| 22 | Providing and laying earth connection from earth electrode with 6 SWG dia GI wire in 15mm dia GI pipe from earth electrode including connection with GI thimble excavation and re-filling complete all as specified and directed. |
| 23 | Taking down unserviceable distribution boards of any size with RCBOs/ MCBs/MCCBs any type for taking schedule of credit |
| 24 | Supply and fixing BLDC ceiling fans 1200mm sweep complete with blades, down rods of adequate length ( not less than 300mm) with electronic regulator and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00, BEE five star rated with brushless direct current motor (BLDC), white colour complete including making electric connection by providing 1.0 Sqmm X 3 core flexible sheathed copper cable from ceiling rose / source to fan connector. |
| 25 | Supply and fixing air circulator heavy duty (wall mounting) fan 450mm sweep, 230V, AC, 50 Hz cmoplete all as specified and directed. |
| 26 | Demolishing cement concrete of any description and any position not otherwise specially provided for including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) getting out all kinds of soil and including returning, filling, disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. |
| 28 | Supply, laying spreading and compaction stone aggregate of size 63mm in uniform thickness hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camper etc applying brooming requsite type of screening/binding material to fill upintersticks of course aggregate, watering and compacting to the required dencity complete all as specified and directed. |
| 29 | Providing and laying in position cement concrete of specified grade 1:4:8 using stone aggregate 40 mm nominal size complete all as specified and as directed. |
| 30 | M & L for Cement concrete 1:2:4 in pavements/sub base of floor laid to required slope and camber in panels as required including consolidation finishing and tamping complete all as specified and directed. |
| 31 | Provide and fix Chequerred precast cement concrete tiles 22 mm thick light shade using white cement and pigment in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete laid over and including, on 20 mm thick bed of cement mortar 1:4 complete all as specified and directed. |
| 32 | M & L for Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of crushed stone sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 33 | Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m in ordinary rock. |
| 34 | Providing and laying cement concrete 1:3:6 (using stone aggregate 20 mm nominal size) in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 36 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead complete all as specified and directed. |
| 37 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc complete all as specified and directed. |
| 38 | Providing and applying painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats on new/old wood work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed. |
| 39 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of G.S. Sheet complete all as specified and directed. |
| 40 | Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 41 | Demolishing brick work in cement mortar manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 42 | Providing and laying Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) complete all as specified and directed. |
| 43 | M & L for 12mm thick rendering in cm (1:6) on fair faces of brick work or concrete surfaces of wall complete all as specified and directed. |
| 44 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:2:4 using stone aggregate 20 mm nominal size all as specified and as directed. |
| 45 | M&L for pre-polished kota stone slabs 20 mm thick in risers/treads of steps, skirting, dado and pillars laid over and including 12 mm (average) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 47 | Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 48 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead of sectional area 40 square centimetres and above complete all as specified and directed. |
| 49 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead of sectional area 40 square centimetres and below complete all as specified and directed. |
| 50 | Providing 0.63 mm thick with zinc coating not less than 275 gm/ m²corrugated G.I sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required |
| 51 | All as per Sl No 50 above but except sheet. |
| 52 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws Ridges plain (500 - 600mm) complete all as specified and directed. |
| 53 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on wood/steel frame work complete (steel frame work to be paid separately). |
| 54 | All as per Sl No 55 above but except Mangalore tiles. |
| 55 | M & L for 20mm thick magalore patern ridge tiles bedded and jointed in cement mortar 1:6 complete all as specified and directed. |
| 56 | M & L for Plain fillets. square, rectangular or triangular in section, clean sawn, secured with nails or brads 2nd class hardwood exc 6 Sqcm and n.exc 13 Sqcm complete all as specified and directed. |
| 57 | Providing & fixing 2nd class hard sal wood work in frames of manglore tiles roof below/false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc complete all as specified and directed. |
| 58 | Providing and applying for UV Resistant roof paint (Teraracotta) two coats/as per manufacturer instructions for roof tiles protection including cleaning of all dust/dashes etc complete all as specified and dirceted. (Make.- Asian or Indigo Paints) |
| 59 | Providing and fixing G.I. chain link fabric fencing made of G.I. wire of dia 4 mm of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 60 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 61 | Providing and fixing false ceiling 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting) complete all as specified and directed. |
| 62 | M & L for 20mm thick 2nd class softwood clean sawn boards or planks, width n exc. 25 cm complete all as specified and directed. |
| 63 | Material and labour for RCC M-25 (design mix) (20mm graded stone aggregate) as in floors, roofs, landing etc. all as specified and as directed. |
| 64 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landing, shelf etc. |
| 65 | M & L for Steel reinforcement Thermo-Mechanically Treated bars of grade Fe-500D or more for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 66 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished Granite stone slab of shade as approved, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, colour and texture laid over 20 mm thick base cement mortar 1:4 joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels all as directed. |
| 67 | Dismantling floor, hearth or wall tilling 10mm to 25mm thick including cement mortar bedding (but not backing), removing serviveable tiles to store and rubbish off the premises complete all as specified and directed. |
| 68 | Providing and laying Ceramic Anti-skid floor tiles of thickness not less than 7mm of 1st quality of approved make and colour, laid on 20 mm thick cement mortar 1:4, Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. complete all as speciied and directed. |
| 69 | Providing and fixing Ist quality ceramic glazed wall tiles 300x450 of thickness not less than 7mm of approved make and colours as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 70 | Providing and laying Vitrified tiles of size 600mm x 600mm in floor of thickness not less than 9mm, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. complete all as specified and directed. |
| 71 | Providing and laying Vitrified tiles of thickness not less than 9mm, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 72 | Material and labour for preparation of newly plastered wall surface and applying two coat (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) of premium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology , Excellent Dirt Pick up resistance of over one coat of acrylic water based exterior grade primer @ 0.9ltr(undiluted)/10 sq mtrs diluted with water in 1:1ratio as per manufacture's instruction and all coats incl primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and directed. |
| 73 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 74 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 75 | Dismantling G.I. pipes 15 mm to 40 mm nominal bore including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge. |
| 76 | Providing and fixing G.I. Pipes 15 mm dia nominal bore complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall complete as per direction of Engineer-in- charge. |
| 77 | Providing and fixing 20mm bore Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 78 | Providing and fixing gun metal gate valve 20 mm nominal bore with C.I. wheel of approved quality (screwed end) complete all as specified and directed. |
| 79 | Providing and fixing white Vitreous China Wash basin of size 630x450 mm with a single 15 mm C.P. brass pillar tap with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require complete all as specified and directed. |
| 80 | Providing and fixing in repairs 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 81 | Providing and fixing in repairs chromium plated towel rail 600 mm long with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 82 | Supply and fix Unplasticised P.V.C. connection pipe 15 mm bore with brass union 45 cm long complete all as specified and directed. |
| 83 | S & F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 84 | S & F for chromium plated two way bib cock complete all as specified. (Make Jaquar cat part No. CON-041KN ) |
| 85 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 86 | Supply and fix 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 87 | Supply and fix 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls complete all as specified and directed. |
| 88 | Supply and fix 110 mm PVC (SWR) bends and provided with access door complete all as specified and directed. |
| 89 | Supply and fix 110 mm PVC (SWR) bends complete all as specified and directed. |
| 90 | Material and labour for preparing old surfaces and finishing walls with two coats of Acrylic Smooth exterior paint of required shade as directed by engr-in-charge (Two coat applied @ 1.67 ltr/ 10 sqm). |
| 91 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. |
| 92 | M&L for kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 complete all as specified and directed. |
| 93 | M&L for kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 94 | Providing and applying painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two coats on new/old wood work over an under coat of suitable shade with ordinary paint of approved brand and manufacture complete all as specified and directed. |
| 95 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 96 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for easurements and disposal of unserviceable material as directed, within a lead of 50m.Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia all as specified and directed. |
| 97 | M & L for Concrete bed to drain pipes for 150mm bore pipe including packing under, and haunching against the sides of pipes after they are laid and tested in Cement concrete 1:4:8 type D-2 (40mm graded stone aggregate) complete all as specified and directed. |
| 98 | Providing and laying non-pressure NP2 class (light duty) 150 mm dia R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete all s specified and directed. |
| 99 | Constructing brick masonry With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 manhole in cement mortar 1:4 with R.C.C. top slab with 1:1.5:3 mix using stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix using stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (using stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) . |
| 100 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix using stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3, finished with a floating coat of neat cement and making necessary channels for the drain etc. complete For pipes 100 to 250 mm diameter complete all as specified and directed. Please Enable Macros to View BoQ information |