| 1 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 2 | Demolition of reinforced cement concrete in any position complete all as specified. |
| 3 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons Laid, bedded and pointed in any mortar etc. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 5 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 6 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated/crimped steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 7 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 8 | S&F 1mm thick Plain, galvanised, mild steel sheeting in valley gutters of any shape trapezoidal/circular, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and fixed to steel members with plain 40 mm lap joints or welded/rivetted scams including bending turning up, mitred angle stopped ends outlets etc as required complete all as specified and directed. |
| 9 | S&F Aluminium wind driven turbo ventilator 600mm dia for roof top including aluminium vortex blades (42 Nos vanes of 0.5mm thickness) Turbine shaft, horizontal & vertical bracing of SS 304, PVC sheet base, double shielded ball bearing complete all as specified as per manufactures instrucions. |
| 10 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars, etc but excluding ashlar facings, dressed stonework, precast concrete articles and precast concrete block walling all as specified and directed. |
| 11 | M&L 1:3:6 type C-1 precast cement concrete (20mm graded stone aggregate) block masonary with solid blocks exc 10 cm in width and not exc 20cm in width and setting in cement mortar 1:6. |
| 12 | M&L for providing reinforced cement concrete 1:2:4 type B1 ( 20 mm graded stone aggregate) as chajja , shelves etc complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item) |
| 13 | M&L for providing reinforced cement concrete 1:2:4 type B1 (20 mm graded stone aggregate) as beams, cantilevers, bressummers , lintel over 1.5 mtr span complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately under respective item) |
| 14 | Use & waste form work rough finished surfaces of concrete to chajja ,shelves , troughs and similar items including edges complete all as specified and directed |
| 15 | Use & waste form work rough finished surfaces of concrete to sides and soffits of beams , lintel and similar items complete |
| 16 | S&F mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing wire complete all as specified & directed. |
| 17 | M&L TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for stirrups, hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips conforming to Fe-410-W (Gde.E-250) Part- I quality-A or Fe 290 (Gde - E-165) |
| 18 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded crushed stone aggregate) complete as in levelling of floor etc all as specified and as directed. |
| 19 | M&L Machine cut kota stone slab flooring 20-25mm thick over 20 mm cement screed base CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing. complete all as specified and directed. |
| 20 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 15mm thick rendering in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing. complete all as specified and directed. |
| 21 | M&L for Non skid ceramic coloured (colour & shade as approved) tiles of 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors set and jointed in neat cement slurry over and including 15mm thick screed in cement mortar (1:6) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 22 | M&L for Non - skid ceramic coloured joint free tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10 mm thick screed bed in CM (1: 4) complete all specified and directed. |
| 23 | M&L for light shade Vitrified tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick cement screed bed or bedding layer in CM (1:6) Complete all as specified and as directed. |
| 24 | M&L for light shade Vitrified tile 10mm thick polished, area of tile n exc.0.36 sqm as in Skirting set and jointed in cement slurry over and including 10mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified. |
| 25 | M&L for glazed clolour ceramic tiles of size 350x 250x 7 mm/ 450X 350X 7mm thick as in vertical surfaces/dado laid over 10mm thick rendering as back coat in CM 1:4 etc. set and jointed in neat cement slurry and pointed in coloured cement with pigment complete all as specifed and as directed. |
| 26 | M&L for 20 mm thick Granite (of any type and colour) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admix ture of pigment to match with shade of granite incl all moulding etc complete all as specified & as directed . |
| 27 | M&L for Cement concrete (1:3:6), type C-1 using 20mm graded stone aggregate span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles, throating and necessary form work complete all as specified. |
| 28 | Taking down cement plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 29 | M & L for rendering 15 mm thick on stone masonry surfaces or surface other than fair face of brick-work or concrete surfaces in cement mortar 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement). |
| 30 | M & L for rendering 10 mm thick on stone masonry surfaces or surface other than fair face of brick-work or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement). |
| 31 | Supply only integral water proofing compound of approved brand/make. |
| 32 | M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of Chalk whitening complete all as specified and directed. |
| 33 | M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. |
| 34 | M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper on walls over a coat of wall care putty complete all as specified and directed. |
| 35 | M&L for complete removal of existing treatment on surfaces of walls apply two coat of cement base paint complete all as specified. |
| 36 | M&L for complete removal of existing treatment on surfaces of walls apply two coat of oil bound distemper over wall putty complete all as specified. |
| 37 | Taking down chowkats or frames exc 1.5 sq.m but n.exc 4 sq.m each but with shutters (without taking off shutters from the frames). |
| 38 | Taking down chowkats or frames not exc 1.5 sq.m each but with shutters (without taking off shutters from the frames). |
| 39 | Taking down shutters of any description exc 1 sqm and not exc 2 sqm each and removing from site. |
| 40 | S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed. |
| 41 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDMrubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete all as specified and directed. |
| 42 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge |
| 43 | S&F Pressed steel frames made of MS sheet of profile 125 mm X 60 mm for door and window frames with one or more rebates including lock strike plate, shock absorber, 20 mm dia 60 mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 44 | S&F 35mm thick second class hardwood glazed and Skelton door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed. |
| 45 | S&F 35 mm thick second class hard wood plain, framed, panelled shutters(any no of panels) with panels of timber flat on both sides (feather edge) or of veneered partical board medium density, wood partical board with commercial face veneers; supply and fix to chowkats complete all as specified. |
| 46 | S&F of factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tubes for top & bottom rail. MS frame shall be covered with heat moulded wood grain printed PVC sheet ‘C’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of wood grain PVC sheet to be fitted to the MS Frame/sealed to the stiles & rails with suitable PVC sheet beading, & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (90) degree used and joined together with solvent cement, all as specified. |
| 47 | M/L for solid PVC door frame of size 50x47mm made out of 5mm thick wood grain printed pvc sheet reinforced with MS square tube all as specified. |
| 48 | Dismantling boarding, any description, fixed in any position with screws complete with all fittings all as specified and directed. |
| 49 | S&F prelaminated particle board of 18/19 mm thick oneside decorative face of exterior grade as in wardrobe and cup board shutters and Shelves etc. complete all as specified and directed. |
| 50 | S&F continuous (piano) hinges 40 mm flap width, brass, bright finish or electrogalvanised complete all as specified & directed. |
| 51 | S & F 125mm Aluminium handles, cast type, anodised and fixed with screws complete all as specified. |
| 52 | S&F Hasp and staple of aluminium anodized, safety type, 100mm long, fixed with screws complete all as specified. |
| 53 | S&F magnet catchment of specified shape and size for cupboard selves in kitchen ect, complete all as specified. |
| 54 | S & F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc.complete all as specified and directed. |
| 55 | S & F in repairs Stainless steel curtain rod with fixing brackets, stops, rollers etc.complete all as specified and directed. |
| 56 | M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 57 | S&F box type steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded, complete all as specified and directed. |
| 58 | All as per item No 57 but without glazing bars |
| 59 | S&F box type Steel windows or ventilators, fixed type, with glazing bars complete all as specified. |
| 60 | Supply and fabrication of framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified. |
| 61 | M & L for preparation of new or previously untreated surfaces of steel of any description , over 10 cm in width or girth not otherwise described applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer. |
| 62 | M & L for preparation of old steel surfaces of any description , over 10 cm in width or girth not otherwise described one coat of synthetic enamel paint complete all as specified. |
| 63 | M& L for 50 mm thick PCC 1:3:6 type C-1(using mechanically crushed 20 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement including forming joints in 2 mtr intervals and filled with bitumen mastics complete all as specified and as directed. |
| 64 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed |
| 65 | S&F in Galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified. |
| 66 | S&F 3.00 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 67 | S&F 4.80 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed. |
| 68 | M&L for 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame work complete all as specified and directed by Engineer in Charge |
| 69 | S&F mortice brass lock vertical type size 100mm with 4 levers complete all as specified and as directed. |
| 70 | S & F 300mm length aluminium alloy, anodised, sliding door bolt hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. |
| 71 | S & F 150mm Aluminium handles, cast type, anodised |
| 72 | S & F 200 mm aluminium, anodised, barrel tower bolts of extruded section and fixed. |
| 73 | S & F 100mm Aluminium handles, cast type, anodised |
| 74 | S&F 100mm long aluminium, anodised barrel tower bolts of extruded section, all as specified and as directed by the Engr-in-charge. |
| 75 | S&F Aluminium (die cast ) body door closer hydraulically regulated designation No 3 universal type, suitable fo door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg. C omplete all as specified and as directed. |
| 76 | S & F 100 mm butt hinges, medium weight, cold rolled mild steel and fixed. |
| 77 | S & F mild steel 300mm ordinary rat tail rod pattern springs, including roller and roller plate complete. |
| 78 | S & F floor door stopper of alluminium alloy body and toungue anodised with hard drawn steel spring overall length of cover plate 140mm complete all as specified and directed. |
| 79 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 80 | S&F roof trusess (framed), verticle pole , trussed ,purlin, crane gantries rails and fastenings and heavy bracket framing (beam tee angle channel or flat section ) including distance pieces,cleats etc confirming to Fe 410-W (grade -E-250) quality A complete all as specified and directed. |
| 81 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesetc confirming to Fe 410-W (grade -E-250) quality A complete all as specified and directed. |
| 82 | S&F Mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment and fixing complete all as specified and directed by Engr-in-Charge. |
| 83 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets. Please Enable Macros to View BoQ information |
| 84 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness inclduding cover fillets. Please Enable Macros to View BoQ information |