| 1 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified. |
| 2 | M&L for 100mm thick PCC 1:2:4 type B-1 20mm graded stone agg as in floor finished even and smooth with using extra cement |
| 3 | wearproofing tipping 15 mm thick as specified (incorporating an approved non metalic Flor harderner @ 5 kg per sqm ) laid on concrete floors and pavings and finished even and smooth ( non metallic harderner shall be measuredseperately and paid at supplied only rates ) |
| 4 | Supply only non metallic floor hardener |
| 5 | Dismantling floor hearth and wall tiles including cement mortar bedding (but not backing) and removing from site complete all as directed. |
| 6 | M&L for glazed clolour ceramic tiles of size 300x450x6-7 mm thick as in dado laid over rendering in 10mm thick back coat in CM 1:4 etc. set and jointed in neat cement slurry and pointed in coloured cement with pigment complete all as specifed and as directed. |
| 7 | Demolition of Stone slabs and tiles laid bedded pointed in mortar of any description or thickness in floors, aprons etc. |
| 8 | M&L Machine cut kota stone slab flooring 20-25mm thick over 20 mm cement screed base CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing polishing and rounded or chamfered for nosing complete all as per specified. |
| 9 | M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick rendering (1:4) and jointed with ditto as per above item no 8 complete all as per specified |
| 10 | M&L chequered cement concrete tiles 20cmx 20cmx 25mm thick,set, jointed & pointed in neat cement slurry in floors with grey cement and pigments over & including 20mm thick screed in cement mortar 1:6 complete all as per specified. |
| 11 | M&L for 75 mm thick P.C.C 1:4:8 type B-2 using 40mm graded stone agg as in sub base of floor complete all as specified and as directed. |
| 12 | Demolation brick work built/ stone masonary in cement mortar of any specification and in any position complete all as specified. |
| 13 | M&L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 3: 6 type C-1, using 20 mm graded stone aggregate, any width and setting in cement mortar 1 : 6, complete all as specified and directed by Engr-in-charge. |
| 14 | M&L 75 mm thick PCC 1:3:6 Type C-1 using 20mm crushed stone aggregate as in plinth protection and finished even and smooth without using extra cement complete all as specified. |
| 15 | Bitumastic filling, with 85/25 bitumen and coarse sand mixture. 1:3 by weight, as in plinth protection complete all as specified & directed. |
| 16 | Dismantling of plain or corrugated steel sheeting, any guage, thickness from roof covering complete all as specified. Note :- Hieght of ceiling is upto 4 m and above |
| 17 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. Note :- Hieght of ceiling is upto 4 m and above |
| 18 | S&F 0.63 mm Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified. Note :- Hieght of ceiling is upto 4 m and above |
| 19 | Taking down cement or cement lime plaster any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 20 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement (with water proofing compound) complete all as specified and directed. |
| 21 | Supply only Integral waterproofing compound as per manufacturer instructions complete all as specified. |
| 22 | M&L two coats cement base paint on plastered surface including preparation of newly plastered surfaces complete all as specified. |
| 23 | M&L for 10mm thick rendering in CM (1:6) on internal surfaces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed. |
| 24 | M&L Preparation of new plastered surfaces wall and applying two coats of Oil bound distember over a coat of primer complete all as specified. |
| 25 | M&L Washing rubbing down and stoping of distempered and painted surfaces and applying one coat of oil bound distemper on walls surfaces including proper curing all as specified. |
| 26 | M&L of for washing rubbing down and stopping of cement base painted surfaces and applying one coat of cement based paint on wall surfaces including proper curing all as specified and directed. |
| 27 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 28 | Taking down chowkhats with shutters (without taking off shutters from the frame) and removing from site, area not exceeding 1.5 Sqm each, complete all as specified and directed. |
| 29 | S&F 1.25 mm thick pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 30 | S&F 35mm thick second class hard wood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified. |
| 31 | S&F Factory made box type steel window with pintle hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified |
| 32 | S&F Factory made box type steel window with pintol hinges & 2 Nos 150mm mild steel tower bolts to each shutter, steel handle and without glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified |
| 33 | M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as spd and directed. |
| 34 | S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified. |
| 35 | S&F 250mm aluminium alloy anodised sliding bolts with hasp, staple and fixing clips of sheet, cast or extruded section fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified. |
| 36 | S&F 100mm butt hinges medium weight cold rolled mild steel ISI marked and fixed with mild steel wood screws or welded to angle frame, complete all as specified and directed. |
| 37 | S&F 150 mm Aluminium handles, cast type, anodised complete all as specified and directed. |
| 38 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed. |
| 39 | S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty in squares n,exc 0.5 Sqm, each pane complete all as specified. |
| 40 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified. |
| 41 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings steel sheeting or other covering, running rails and guides and hanging; also fastening and fixing Fe 410 Gde -250 grade quality A complete all as specified and directed |
| 42 | S&F Rolled section as in post /pillars hip and jack rafters; purlins where connected with angle cleat or other connecting plate etc of fe 410-W(grade E-250)quality 'B' including fabrication , erection and fixing complete all as specified and directed by engr-in- charge Note :- Hieght of ceiling is upto 4 m and above |
| 43 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 44 | M&L one coats of synthetic enamal paint to steel surfaces of any discription not otherwise described over 10cm width or girth preparation of old surfaces complete all as specified. |
| 45 | Dismantling wall and ceiling boards of any description or any thickness including cover fillets complete all as directed. |
| 46 | S&F powder coated GI snap grid of size 605 X 605mm frame work for false ceiling including hangers 2mm dia G.I. (upto 1200 to 1500mm length) adjusting level fixed to roof slabs/ truss by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long whereever required or tie on structural steel complete all as specified and directed. Note :- Hieght of ceiling is upto 4 m and above |
| 47 | S&F Exposed metal frame ceiling with 8mm thick decorative laminated calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mmX600mm grid (frame work for ceiling shall be measured and paid seprately) complete all as specified and directed. Note :- Hieght of ceiling is upto 4 m and above |
| 48 | Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 49 | M&L for PCC 1:2:4 B1, 20mm graded stone aggregate as in surface channels and drains complete all as specified and directed |
| 50 | Extra forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, mould, mitred/stopped ends etc. complete all as specified and directed |
| 51 | Demolition of reiforced cement concrete in amy postion and any description including cutting og reinforcement bars of facilities demolition complete allas specified and directed |
| 52 | M&L For Providing precast cement concrete in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with ma sonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including cham fers, weatherings, throat- ing etc. and setting in mortar complete with joint match but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas,water troughs,mangers, shelves and similar articleswith plain faces and 20 mm graded stone aggrigate type B-1 (1:2:4) complete all as specified and directed by engr in charge |
| 53 | Mild steel bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 54 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 55 | M&L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulated stranded copper conductor cable for continous earthing in & incl casing capping point wiring with accessories having ISI mark for one light/fan/bell point/5 amp indep/power point/same board controlled by one switch complete all as specified and directed. |
| 56 | All as per item No 55 here-in-before but for one multipin socket outlet 5 Amp but using 2x 1.5 + 1 x 1.5 sqmm multistranded FRLS copper cable on the independent board. |
| 57 | All as per item No 55 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches. |
| 58 | All as per item No 55 here-in-before but for one multipin socket outlet 15 Amp, but using 2 x2.5 +1 x 2.5 sqmm multistranded FRLS copper cable, independent board. |
| 59 | S&F in replacement of switch piano type 5 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 60 | S&F in replacement of socket outlet multipin 5 Amp 230 Volt flush type complete all as specified and directed. |
| 61 | S&F in replacement of switch piano type 15 Amp, 230 Volt, flush type single pole one way complete all as specified and directed. |
| 62 | S&F in replacement of socket outlet multi pin 15 Amp 230 Volt flush type complete all as specified and directed. |
| 63 | S&F In replacement of for Lamp holder, PVC/Polycarbonate type with back plate suitable for Angle/batten fittings complete all as specified and directed |
| 64 | S&F of rechargeable led bulb minimum 4 Hrs Battery backup 9 Watt B-22 Base complete all as specified and directed. |
| 65 | S&F in rplacement of Ceiling rose, 3 terminal, PVC isolated body complete all as specified and directed |
| 66 | S&F in replacement of LED light fitting 20W, 220 volt AC, having colour temperature daylight (6500K), Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 67 | S&F metal type exhaust fan single phase 230/240V of 450 mm sweep heavy duty 1400 rpm including louvre & cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed. |
| 68 | S&F including flushing in wall MCB distribution board vertical TPN 4 way 415 volt AC double door sheet with bus bar neutral earth bar including provision of MCB TPN 63 amp conforming to IP 43 as incomer complete all as specified and directed. |
| 69 | S&F MCB TPN 63 amp 415 volt with bearing capacity of 16 KA complete all as sp[ecified and directed. |
| 70 | S&F in replacement of sheet metal enclosure double door distribution board single pole and neutral, 12 way 240 volt with 200 amps rated bus bar complete with bus and neutral link complete all as specified and directed. |
| 71 | S&F in replacement of MCB 6 to 32 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 72 | S&F in replacement of MCB SPN 40 amp2 amp rating 240V, 10KA 'B' curve, Single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 73 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 95 sqmm 3.5 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 74 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 35 sqmm 3.5 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 75 | Supply & laying LT UG XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volts grade cross-sectional area 10 sqmm 2 core as per IS specification laid through GI pipe/on floor/wall complete all as specified and directed |
| 76 | Supply and laying of GI pipe light galvanized with all fitting laid in trenches for cable proctection of 50 mm bore all as specified and directed. |
| 77 | M&L in replacement of Earthing complete with galvanised steel earth plate electrode 600×600×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as directed. |
| 78 | Supply and fixing Building LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. all as specified and directed. |
| 79 | Supply, laying and drawing in and including 20 mm dia casing caping including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed. |
| 80 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/dense soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level all as specified and directed by Engineer- in- Charge. |
| 81 | Returning filling in,. Including spreading, leveling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed. |
| 82 | Removing excavated material (i.e. soil) from site to a distance n. exec 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge. |
| 83 | Supply and fixing ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep with squirrel cage induction motor complete all as specified and directed. |
| 84 | S&F in replacement of stepped type electronic fan regulator flush type, complete all as specified and directed |
| 85 | S&F for fixing of GI pipe (light grade) bracket of 40mm dia size of 1.2 mtr long bent to shape for fixing of LED street light fittings and fixing to pole, walls etc including fixing of clamp, nut, bolt etc as specified and directed. |
| 86 | S&F of double wall corrugated HDPE duct pipe of 75 mm outer dia PN 10 of approved colour with fittings for cable protection complete all as directed. |
| 87 | S&F of double wall corrugated HDPE duct pipe of 25 mm outer dia PN 10 of approved colour with fittings for cable protection complete all as directed. |
| 88 | Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as directed. Please Enable Macros to View BoQ information |
| 89 | Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of size 450mm x 450mm x 300mm with 4 Nos 500 Amps aluminium bus bar and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level complete all as directed. Please Enable Macros to View BoQ information |