| 1 | Taking down old chawkats or frams exc 1.5 sqm but n.exc 4 sqm each without taking off shutters from frame complete all as specified and directed. |
| 2 | Taking down old chawkats or frams n. exc 1.5 sqm each without taking off shutters from frame complete all as specified and directed. |
| 3 | Dismantling MS framed trusses of span n.exc 10m complete all as specified and directed. |
| 4 | Dismantling MS framed trusses of span exc 10m but n.exc 15m complete all as specified and directed. |
| 5 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed. |
| 6 | Demolition of brickwork, stone / boulder or PCC Block masonry, built in cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed . |
| 7 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed . |
| 8 | Dismantling of floor, hearth or wall tiling including cement mortar bedding but not backing coat and renmoval of rubbish out side MD land complete all as specified and as directed. |
| 9 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness (below or above ground level) complete all as specified and as directed |
| 10 | S&F Alurninium anodised grill (anodised transparent or dyed to required shade according to IS 1868 with rninirnurn anodic coating of grade AC 15) of approved design/pattern with approved standared section and fixed to the existing window frame with CP brass /stainless steel screws @ 200mm c/c, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as per requirement and as directed. |
| 11 | S&F aluminium powder coated (minimum thickness of powder coating 50 micron) anodised aluminium frame section of door, windows, ventilation, partion wall, cup board with one or more rebates including joinging cleats for fixing etc. complete all as specified and as directed. |
| 12 | S&F aluminium powder coated anodised aluminium two track window and ventilator shutters, fixed type without sash bars, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading,screws, anodiised aluminium fittings complete all as specified and as directed . |
| 13 | S&F Sheet glass 5.5mm thick selected quality in square n. exc 0.5 Sqm in each pane complete all as specified and as directed. |
| 14 | S & F Aluminium rolling shtter with 1 mm thick aluminium extruded double wall slat of convex corrugation, with 2 mm thick aluminium side guide with and including all fittings and bottom component bar,mild steel bracket with suitable stiffners and mild steel heavy duty shaft with sufficient outer diameter to carry torsional load and springs made up with special spring wire. The gate shall be fitted with mechanical bevel gear box manually operated with cranks and lever arm as recommanded by the manufacturer of the aluminium rolling shutters with suitable aluminium hood cover.(All the aluminium item shall be powder coated of not less than 50micron) including making the rolling shutters functional in all aspects with suitable locking arrangements including dismantling rolling shutters of any description, including side guides embedded in masonry wall complete all as specified and as directed.Note:- (i) The size of opening for rolling shutter shall be as per site requirement.(ii) Measurement of rolling shutter will be the measurement of clear opening.(iii) The rate quoted includes making good of distrubed surfaces to match with existing surfaces complete all as directed. |
| 15 | Pre -cast cement concrete block masonary with solid blocks exc 10 cm in width type C-1 1:3:6 (20mm graded stone aggregate) set in cement mortar 1:6 complete complete all as specified |
| 16 | Taking down cement plaster on brick walls or stone walls any descrition etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 17 | Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces with sagol finish complete all as specified and as directed. |
| 18 | Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even and fair without using extra cement including mixing of water proofing compound as per manufacturer instructions complete all as specified and as directed. Note: WPC will be measured and paid seperately as suplly only item |
| 19 | Supply only liquid water proofing compound |
| 20 | Forming square grooves in plaster n exc 12mm deep and n exc 15mm on face complete all as specified and as directed. |
| 21 | M&L 40mm thick PCC 1:2:4 type B0 using 12.5mm graded aggregate as in levelling course complete all as specified and as directed. |
| 22 | M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base complete all as specified and as directed. |
| 23 | S &F rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 410 - W (Gde- E- 250) quality- A complete all as specified and as directed . |
| 24 | S & F Pre painted galvanume aluminium zinc coating GI based corrigated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and as directed . |
| 25 | S & F Pre painted galvanume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / clading to wall, fixed with self tapping screws complete all as specified and as directed . |
| 26 | M&L Non-skid ceramic coloured tiles 7 to 8 mm thick (square), area of each tile exc 0.18 but not exc 0.38 sqm as in floors etc set and jointed in net cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 27 | Taking down drain pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 28 | S&F 225 mm bore half PVC(SWR) pipes single socketed including supporting MS clamps , any length & position with rubber rings joints, fixed to walls and roof edges of sloped roof buildings complete all as specified and as directed. |
| 29 | S&F PVC (SWR) pipes, 110 mm dia bore, single socketed, in any length with using rubber joints,fixed to walls complete all as specified and as directed |
| 30 | S & F PVC (SWR) bend, 110 mm dia bore,any radius complete all as specified and as directed. |
| 31 | M&L prepapration of new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 32 | Preparation of newly plastered surfaces and applying two or more coat of acrylic smooth exterior paint of approved shade @ 1.67 ltr / 10 sqm over and including two or more coat priming coat of exterior primer 2.2 kg / 10 sqm complete all as specified and as directed . |
| 33 | Complete removal of existing treatment and applying two or more coats of 100% Premium acrylic weather proof emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 34 | Preparation of new plastered surface of wall and applying 3.0 mm thick wall care putty and making the surface smooth followed by two coats of distemper oil emulsion, ( ready mixed), of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete all as specified and as directed. |
| 35 | Complete removal of existing treatment and applying 3.0 mm thick wall care putty and making the surface smooth followed by two coats of distemper oil emulsion, ( ready mixed), of approved manufacturer, of required shade and colour over a coat of alkali resistant primer complete all as specified and as directed. |
| 36 | S&F in replacement of LED high bay light fitting 63 watt made up of pressure die cast aluminum alloy housing with toughned glass, IP-65 protection and impact resistance of IK07 and individual high power LED's with secondary optics having system lumen efficay>150 lm/w, coloured temperature 5700K, wide beam angle inbuilt potted electronic LED driver with APFC ( SMPS based constant current supply) lower THD,open circuit protection, over voltage protection, surge voltage protection & other safety test as per IS 15885 part -2/Sec 13 and BIS complying including surface mounting using adjustable MS cradle of 5mm thick provided with the fixture complete all as specified and as directed |
| 37 | S&F in replacement of PVC insulated and sheathed cable galvanised steel strip or wire armoured , electric control cables ( heavy duty) with stranded copper conductor of size 3 core 4 sqmm complete all as specified and directed . |
| 38 | Taking down old unserviceable LT UG cable from existing position and Supply & laying, connecting and commissioning of LT UG cable 16 sqmm 4 core, 1100 volts grade XLPE insulated armoured heavy duty electric cables with aluminium conductor including connecting with suitable size of cable glands lugs etc. laid in trenches or fixed on walls complete all as specified and as directed |
| 39 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 2.5 sq mm (FRLS) in and including concealed 25mm dia PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 2.5 Sq mm (FRLS) of continuous earth wire green in colour including taking down old sub main wiring complete all as specified and directed .NOTE: Three runs of 2.5 sqmm cable and one run of PVC conduit shall be paid as one unit . |
| 40 | M&L double wall corrugated HDPE pipe ( ISI marked) of outer dia 50mm and 38mm inner dia with smooth internal and profiled external surface, non pressure type, laid in trenches/ floors/ duct or fixed on walls /pole including al connections, accessories like socket, couplers, bends etc., for protection of LT cable complete all as specified and as directed . |
| 41 | S & F in replacement of Distribution board VTPN 4 way Vertical type double door 440 Volts, 3 phase with rated bus bar 250 Amps,double door,IP-54 protection and mechanical strength IK 09, isolated neutral bus bar suitable for accomodate MCCB 3/4 pole 415 voilts rating up to 250 amps as a incomer and MCB's as out going grouted in walls complete all as specified and as directed. |
| 42 | S & F in replacement of MCCB DPX 160 thermal magnetic 63 Amps , 3 Pole, 16 KA, 415 V 50 Hz including all connections by suitable size of lugs / thimbles complete all as specified and as directed . |
| 43 | S & F in replacement of double door, sheet metal enclosure powder coated SPN DB 8 way with 200 Amps rated bus bar, 230 volt, IP 43 protection, flush in walls including making good of disturbed surface to match with existing surface complete all as specified and as directed |
| 44 | S& F in replacement of MCB SPN, 40 - 63Amps, 240 volts,10 KA, C curve complete all as specified and as directed. |
| 45 | S& F in replacement of MCB SP, 6 amps to 32 Amps, 240 volts,10 KA, C curve complete all as specified and as directed |
| 46 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 depth and getting out in soft / loose soil for laying of cables etc. complete all as specified and as directed . |
| 47 | Returning filling in, with excavated soils including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick complete all as specified and as directed . |
| 48 | Removing excavated material to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed . Please Enable Macros to View BoQ information |