| 1 | BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: CONSTRUCTION OF DEFICIENT LIVING IN ACCN FOR AIRMEN AT AF STN KALAIKUNDA Contract No: CE(AF)SZ/KKD/ OF 2026-2027 File No: 88894/KKD/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE \\"A\\" Part - I (BUILDINGS/STRUCTURES WORK)Details of Buildings are given here-in-before:- |
| 3 | SCHEDULE \\"A\\" PART- II ( SITE CLEARENCE AND AREA DEVELOPMENT) Details of prepriced Schedule is given in tender documents |
| 4 | SCHEDULE \\"A\\" PART- III( INTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 5 | SCHEDULE \\"A\\" PART-IV ( INTERNAL WATER SUPPLY )Details of prepriced Schedule is given in tender documents. |
| 6 | SCHEDULE \\"A\\" PART- V (ROADS / PATHS / CULVERTS)Details of prepriced Schedule is given in tender documents. |
| 7 | SCHEDULE \\"A\\" PART- VI (AREA DRAINAGE)Details of prepriced Schedule is given in tender documents |
| 8 | SCHEDULE \\"A\\" PART- VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 9 | SCHEDULE \\"A\\" PART- VIII(EXTERNAL WATER SUPPLY)Details of prepriced Schedule is given in tender documents |
| 10 | SCHEDULE \\"A\\" PART- IX(EXTERNAL ELECTRIFICATION)Details of prepriced Schedule is given in tender documents. |
| 11 | SCHEDULE \\"A\\" PART- X(HOT WATER SUPPLY)Details of prepriced Schedule is given in tender documents. |
| 12 | SCHEDULE \\"A\\" PART -XI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 13 | INTERNAL ELECTRIFICATIONS&F 10/12 watt rechargeable emergency inverter LED bulb,cool day light up to 4 hours battery backup all as specified and directed |
| 14 | Supply and Fixing LED light fitting 2 feet, 1X10 W, 220 V, AC batten features a durable extruded aluminium body with a high quality PC diffuser for uniform illumination with slim integrated design ensurers easy installation, with efficancy (> 120 Lm/W) optional enhance energyy efficiency including LED tube light connecting up wih three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 15 | S&F wall mounted 3 watt LED flexible and adjustable reading light made of high quality metal with stylish features, higly flexible gooseneck arm allowing you to easily adjust the light direction for focused illumination providing an energy efficient and long lasting connected items, complete all as specified and directed. |
| 16 | Supply and fix MCCB 415 Volts, 3 Pole, 100 Amps, 50 Hz, 32 KA with thermal magnetic release type, complete all as specified and directed. |
| 17 | M&L for Three Phase sub main wiring with 4 run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm alongwith two run of FRLSH type PVC insulated & unsheathed multistranded copper conductor cable of nominal cross sectional area 10 sqmm as earth continuity conductor drawn through and including concealed PVC conduit not less than 25mm dia medium grade complete all as specified and as directed. |
| 18 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6mm thick elecrode and 4 mm dia galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and directed. |
| 19 | INTERNAL WATER SUPPLYS&F brass angle stop cock CP high pressure with capstan head long shank screwed down 15mm dia. bore complete all as specified and directed. |
| 20 | SEWAGE DISPOSALS&F factory made precast RCPC manholes covers of clear internal dia 600mm, 5T load capacity, confirming to IS 12592:2002 placed/fixed in position, complete all as specified and as directed |
| 21 | M & L RCC Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users as per shown in drawing complete all as specified and directed. |
| 22 | M&L for construction of Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 2.4M inner dia X 3.0 M effective depth as per shown in drawing complete all as specified and directed. |
| 23 | EXTERNAL WATER SUPPLYSupply and fix PP-R gate valve brass inserted as per requirement of size 90 mm Outer dia., complete all as specified and directed. |
| 24 | Cutting existing steel tubing upto 150mm dia for alterations or additions complete all as specified and directed. |
| 25 | Screwing existing steel tubing upto 150mm dia for alterations or additions using fittings, complete all as specified and directed. |
| 26 | M&L for construction of brick masonry valve pit of size 90 x 90 x 90 cm (internal dimensions) with one brick thick wall in cement mortar 1 : 4 on 100 mm thick PCC 1:4:8 D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, incl. PCC 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) as in bedding and coping and 10 mm thick cement plaster in CM (1:4) internally and externally upto 15 cm below ground level providing valve pit 25 X 25 X 6 mm angle iron frame all round the fixed point by means of 04 Nos holdfast 150 mm long made out of flat iron 25 X 6 mm embedded in PCC block (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) of size 250 X 200 X 150 mm incl. provision of hinges welded with MS cover 6 mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement incl. 65 mm dia Godrej pad lock and applying two coats synthetic enamel paint over a coat of red oxide primer incl. necessary excavation and earth work in soft/loose soil complete all as specified and directed. |
| 27 | Supply, installation, testing and commissioning of Openwell submersible pumping set electric driven 415 volts TP supply and Install complete of capacity 2 HP inclusive of SWR, Cage and PCC foundation For pumping water from proposed UG Sump complete all as specified and directed. |
| 28 | EXTERNAL ELECTRIFICATIONSupply, Installation, testing and commissioning of distribution transformer of capacity 100 KVA step down indoor type floor mounting, copper wound complete with standard fittings HT 11 KV 3 Phase, LT 433 Volts, 3 Phase 4 Wire, Oil immersed with 'ONAN' type cooling with external cooling tubes/ radiators having no load voltage ratio 11/433 KV connected on secondary side (Secondary outgoing side) in accordance with vector group symbol (DYN-11) conforming to IS 1180 2021/LATEST REVISION LEVEL 2 and having off load tap changer in step of 2.5% on HV side to take care of voltage from ±7.5%, ± 5% to ±2.5% to give output on 433 Volts secondary side and including initial oil filling to appropriate level, control cable and following standard fitting complete all as specified and as directed.(a) Oil Conservator with oil fitting hole cap and drain plug.(b) 01 No of prismatic oil level gauge mounted on conservator wall with first fill of charge upto maximum level.(c) Silica gel dehydrating breather with oil seal and first fill of charge.(d) Pressure release valve with automatic resetting arrangement after release of preassure.(e) Adequate No of thermometer pocket including one thermometer.(f) Top oil filter valve. (g) Bootom oil filter cum drain valve.(h) Rating diagram and terminal marking plate. (j) Earthing terminal - 02 Nos(k) Lifting Lugs - 01 Set (l) Jacking Pads - 01 Set(m) Under carriage with 4 Nos of plain rollers (n) Air release plug on main transformer tank.(o) Adequate Nos of cooling radiators.(p)100mm Dial type oil temperature indicator with maximum red pointer and resetting device. (q) 100 mm dial type winding temperature indicator with maximum red pointer and resetting device. (r) Air insulated cable box on HV and LV side. |
| 29 | M&L for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground (Earth pit not less than 3.0 m deep below ground level) with top edge of the plate not less than 2.25m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in any type of soil(except rock), filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from outside defence land, and to be mixed with and including bentonite - 03 bags of 25 KG each for each pit, construction of PCC earth pit chamber of size 900 x 900 x 450 mm , RCC chamber cover plate, wire mess, funnel, test point, 32 mm dia GI protection pipe light grade and 40 mm GI medium grade peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed. |
| 30 | Supply, installation, testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT Feeder Pillar fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 300 Amps ( Size of copper strip should not be less than 25x4 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. . |
| 31 | (Srl Item No. 29.00 Contd...)(A) Incoming : (i) MCCB 160 Amps rating, 4 pole , 415 V, AC, 50 HZ, thermal Magnetic release type, having thermal release range 125-160 Amp with adjustable overload and short circuit setting, Ics=100 % Icu , Service breaking capacity 36 kA - 01 Nos with rotatary handle (ii) Digital 3 Phase Ammeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable ---01 Nos with Suitable CT as per MCCB and wiring with copper wire.(iii) Digital 3 Phase Voltmeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable- 01 No(iv) Three indication lamps- 01 Set (Red, Yellow, Blue).(B) Outgoing : (i) MCCB 125 Amp, 3 Pole, 25 kA, 415 volts, AC, 50Hz thermal adjustable type 100-125 Amp , with operating handle - 02 Nos (ii) MCB SPN 20A 10 KA , 415V - 03 Nos (iii) Astronomical Time Switch 16 Amps 24 hour programming type with ML-4 contractor 70A, 415 V, three phae, coil operating voltage 230 V, three point Auto manual switch 16 Amps for bypass system with 32A 4P MCCB adjustable (40% to 100%) Microprocessor release, 25KA complete including necessary connection.Note :- PCC platform shall be constructed as per manufacturer's recommendation and cost of the same will be included in quoted rate. |
| 32 | Supply and fix LED street light 35 W with energy saving and environmental friendly long life made up of pressure diecast aluminium housing with high power LED as lighting source cover having driver compartment with IP66 protection and impact resistance with built-in surge protection device suitable for mounting for pole including bracket for street light fitting of any size made out of GI pipe medium grade 40 mm dia, 1.5 mtr length bend to required size and shape including provisiob of clamps and fitting in position and including two coat of aluminum paint over a coat of red oxide primer complete all as specified and directed. |
| 33 | Supply and fixing thermo plastic terminal box of size not less than 130 x180 x 77 mm with locking arrangement and necessary mounting arrangement on pole with MS clamps, nut bolt and washers etc including 01 No MCB 6 Amps and PVC connector 3 phase for cable termination, complete all as specified and directed. |
| 34 | M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for HDPE pipe of 150mm dia without distrubing the road surface / Pavment surface/ Hard standing /RCC surface for laying of cable in trenches for pipe of max size 150 mm bore complete all as specified and directed.Note :- Cost of 150mm dia. HDPE pipe shall be included in quoted rates. |
| 35 | COOLING APPLIANCESSupply and fixing desert cooler electric driven (single phase), having nominal air flow capacity of 5000 Cum per hour and 53 L water tank having Plastic/PVC Body are crafted for cooling comfort with an ultra-modern design with 4-way air deflection including honeycomb pas and Pump, complete all as specified and directed. |
| 36 | HOT WATER SUPPLY Supply, installation, testing and commissioning of Solar water heating system of capacity 220 LPD at 65˚ C/85˚ C consisting of solar Flat Plate collectors (Cu-Cu) with ultrasonic welded fins including structural supporting frames, Heat Exchanger, Hot water tank made of Stainless steel-304 with electrical back up including all necessary brick work, PCC works, etc for making foundation and fixing of tanks solar water heating system, complete all as specified and directed.Note : - The contractor shall be submitted schematic diagram for approval of GE before installing. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |