| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR-15.56) |
| 2 | 12mm thick plaster in cement & fine sand of 1.25 fineness modulous mortar in 1:4 Including supply of all materail labour T&P required for proper completion of the work (DSR-13.1.1) |
| 3 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete. (DSR-13.80) |
| 4 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqmover and including one coat of Special primer applied @0.75 ltr /10 sqm. (DSR-13.48.1). |
| 5 | Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand andmanufacture. (DSR-13.62.1) |
| 6 | Removing mortar from from and cleaning stones and concrete articles i/c necessory etc complete in cement mortar CPWD DSR-2023 DSR 15.11.2 |
| 7 | P.C.C. work with cement approved coarse sand and 2cm Gauge approved stone ballast in the proportion of 1:1.5:3 in S/o all materials required for proper completion of the work. CPWD DSR-2023 DSR 4.1.2 |
| 8 | Supply of Fixing Murga Jali PWD SOR2022 ITEM 26 |
| 9 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR-9.20.1) |
| 10 | P/L. 1:5:10 Cement, F/sand & 400mm stone aggregate(DSR - 4.1.11) |
| 11 | P/L Vitrified Tiles Floor over 20mm av. Thick Base of Cement Mortar 1:4 Cement & C/Sand laid with Joint White Cement i/crubbing and polising complete as per DSR No. 11.41.2 |
| 12 | P/L Ceramic glazed Tiles Wall over 20mm av. Thick Base of Cement Mortar 1:4 Cement & C/Sand laid with Joint White Cement i/crubbing and polising completeas per DSR No. 11.37A |
| 13 | Supply/fixing Of Masquito Jali. (M.R.) |
| 14 | Brick Work 1:4 Cement / Coarse Sand Mortar In Super Sturcture. (DSR-6.4.1) |
| 15 | Supply & fixing PVC pipe 110mm (DSR 12.41.2) |
| 16 | Other Hidden Miscellenous Work. |
| 17 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A |
| 18 | Supply and fixing of wire, Power point and Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 nA/250 volt flush typ[e universal modular socket switch on concealed M.S. box including supply of all material, labour t&P etc. required for proper completion of work. |
| 19 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 20 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 21 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire |
| 22 | Providing Drawing Connecting And Testing Of Enhanced Categoey 4 Pair Lan Local Area Network Cable 24 AWG Conductor Performance Specifide 5E U L and CUL Listed In Existing PVC Conduit .(CAT-6 Network Cable) |
| 23 | Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 25MM |
| 24 | Supply & Fixing of following sizes of medium class PVC conduit alongwith accessories in sueface/recess including cutting the wall & making it good the same in case of recessed conduit as required. 32MM |
| 25 | Blank plate for modular plate type switch boards wherever required. |
| 26 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | Supply and fixing of 150mm Fresh Air Fan all complete as per drawing and specification and direction of engineer incharge. Make-Crompton/Bajaj/Havels Equivalent |
| 28 | Supply & Fixing of LED Profile Light all complete as per drawing and specification and direction of engineer incharge. Make Ledadvance/Ledos/Ledlum/Philips, Equivalent |
| 29 | Supply & Fixing of LED Profile Light Driver all complete as per drawing and specification and direction of engineer incharge. Make-Ledadvance/Ledos/Ledlum/Philips, Equivalent Please Enable Macros to View BoQ information |