| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. (DSR 2023- 2.8.1) |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR 2023- 2.25a) |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil (DSR 2023-2.26.1) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2023-2.27) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-lll) derived from natural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources) (DSR 2023-4.1.8) |
| 6 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2023-2.35.3.1) |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 2023-5.1.2) |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)(Raft foundation) (DSR 2023-5.1.2) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 2023-5.1.2) |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(a) (Plinth band) (DSR 2023-5.3) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(a) (Slab) (DSR 2023-5.3) |
| 12 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (a) Slab beam (DSR 2023-5.3) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (a) Column (DSR 2023-5.2.2) |
| 14 | Brick work with common burnt clay non modular bricks of class designation M-150 in foundation and plinth in: 1:4 (1 cement : 4 sand) (DSR 2023-6.1.1) AR |
| 15 | Brick work with common burnt clay non modular bricks of class designation M-150 in foundation and plinth in: 1:6 (1 cement : 6 sand) (DSR 2023-6.1.2) AR |
| 16 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. (DSR 2023-4.13) |
| 17 | Brick work with common burnt clay non modular bricks of class designation M-150 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) (a) Ground Floor to Terrace Floor (DSR 2023-6.4.1) |
| 18 | Brick work with common burnt clay non modular bricks of class designation M-150 in super structure above plinth level up to floor v level in all shapes and size in:1:4 (1 cement : 4 sand) (a) Ground Floor to Terrace Floor (DSR 2023-6.13.2) |
| 19 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (a) UPTO PLINTH (DSR 2023-5.22.6) |
| 20 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (b) Ground Floor to Terrace Floor (DSR 2023-5.22A.6) |
| 21 | 12 mm cement plaster of mix : 1: 6 (1 cement : 6 coarse sand) (a) Ground Floor to Terrace Floor (DSR 2023-13.4.2) |
| 22 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement : 6 coarse sand) (a) Ground Floor to Terrace Floor (DSR 2023-13.5.2) |
| 23 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster. (DSR 2023-13.9.2) |
| 24 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement 40mm thik (DSR 2023-11.3.1) |
| 25 | 38 mm thick wood block flooring of first class teak wood laid over 40mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 10 mm nominal size) to be paidseparately, coated with a thin layer of hot bitumen penetration 80/25(blown type) @ 2.45 kg per sqm, including fixing blocks in position afterdipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete (AR) |
| 26 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (a) Ground Floor to Terrace Floor (DSR 2023-11.41.2) |
| 27 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to |.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 (a) Ground Floor to Terrace Floor (DSR 2023-11.46.2) |
| 28 | Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm (Granite Stone slab of colour Black, Cherry/Rubby Red) (a) Ground Floor to Terrace Floor (DSR 2023-8.2.2.2) |
| 29 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (a) Ground Floor to Terrace Floor (DSR 2023-11.37) |
| 30 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (a) Ground Floor to Terrace Floor (DSR 2023-8.31) |
| 31 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). (DSR 2023-11.3.1*25/40) Apron |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35 mm Thick Single leaf (DSR 2023-9.21.1) |
| 33 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35 mm Thick Double leaf (DSR 2023-9.21.1+9.26) |
| 34 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (DSR 2023-9.53) |
| 35 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. (by weight) (DSR 2023-9.48.1) |
| 36 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) ( Z section windows) (by weight) (DSR 2023- 10.11.1) |
| 37 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 2023-10.15.1) |
| 38 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR 2023-10.18) |
| 39 | Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick (DSR 2023-9.127.2) |
| 40 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70mm & above) x (40mm & above) & both glazed and fly screen sash (25mm & above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). (DSR 2023-9.147A.4.1) |
| 41 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98mm & above) x (40mm & above) & both glazed and fly screen sash (30mm & above) x (55mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m). (DSR 2023-9.147A.4.2) |
| 42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 2023-21.3.2) |
| 43 | Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600. Upto 5mm depth and 5 mm width (DSR 2023-21.19.1) |
| 44 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading (DSR 2023-9.51.2) |
| 45 | Providing and fixing anodised aluminium doors,having 2 mm thick Aluminium section excluding coating & an average coating of 20 micron fully glazed made of Aluminium door tube size 83.5x44.65 mm as Vertical member and 11.40x44.45mm size tube in bottom & horizontal members Door chaukhat ahould be ofAluminium tubler vertical with two openable shutter. The rate will include cost of material fixture 5mm glass handles,locks,screw necessary beeding & excluding cost of floor spring if requred for proper complection of work as per direction of Engineer-in-charge with 5 mm thick plain glass complete. (AR) |
| 46 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC contentless than 50 gram/litre (a) Ground Floor to Terrace Floor (DSR 2023-13.41.1) |
| 47 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.43 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. (a) Ground Floor to Terrace Floor (DSR 2023-13.47.1) |
| 48 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (a) Ground Floor to Terrace Floor (DSR 2023-13.80) |
| 49 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. (DSR 2023-14.34) |
| 50 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . (MR) |
| 51 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.(a) 250 x 10mm (MR) |
| 52 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm (MR) |
| 53 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 2023-13.48.3) |
| 54 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 2023-13.48.2) |
| 55 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (DSR 2023-10.30.1) |
| 56 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. (DSR 2023-10.3) |
| 57 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (C ) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e ) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR 2023-22.7.1) |
| 58 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (DSR 2023-10.28) |
| 59 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).Ordinary cement without any pigment (DSR 2023-11.19.4) |
| 60 | Construction of apron drain (AR) |
| 61 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 2023-10.16.1) |
| 62 | Providing and fixing precoated galvanised iron profile sheets (size shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm (+.05%) total coated thickness with zinc coating 120 grams per sqm as per IS:277 ,in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polymer top coat 15-18 micron. sheet should have protective gaurd film 0f 25 microns minimum to avoid scratches during transportation and should be supplied in single lenth upto 12meter or as desired by engineer-in-chrge .The sheet shall be fixed using self drilling meter or as desired by engineer-in-charge.The sheet shall be fixed drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafter and trusses and including the cost of purlins , raftera and trusses and including cutting ti size and shape wherever required. (DSR 2023-12.50) |
| 63 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² (DSR 2023-12.7.1) |
| 64 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.80 mm thick with zinc coating not less than 275 gm/m² (DSR 2023-12.4.1) |
| 65 | Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with : GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending (DSR 2023-12.54.1) |
| 66 | Providing & fixing 'FlexStone' Wall Cladding Clay Tiles in size 230rnm x 75mrn x 15mm thick in all shades of 'Terracotta' non-pigmented made from natural clay. The appearance and shade of tiles should be natural clay shade or terracotta having subtle variation in shade. The tiles would be made from special clay and firing temperature would be more than 1100° Celsius. The allowed variance in these tiles should not be more than ± 2.5mrn & top surface should be coated with Silicone and surface water absorption should not exceed 1% and by immersion method it should be less than 8%. Equilavet (MR) |
| 67 | Centering and shuttering including strutting, propping etc. and removal of form for : (a) Foundations, footings, bases of columns, etc. for mass concrete (DSR 2023-5.9.1) |
| 68 | Centering and shuttering including strutting, propping etc. and removal of form for : (b) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 2023-5.9.6) |
| 69 | Centering and shuttering including strutting, propping etc. and removal of form for : (c) Lintels, beams, plinth beams, girders, buttresses and cantilevers. (DSR 2023-5.9.5) |
| 70 | Centering and shuttering including strutting, propping etc. and removal of form for : (d) Suspended floors, roofs, landings, balconies and access platform. (DSR 2023-5.9.3) |
| 71 | Add cost of Back Drop of stage with MS frame & acoustical fibre 12 mm thick covered with plain cloth. (LS) |
| 72 | Providing and fixing Genuine Woven Wilt carpet of PP Three Colours Frieze Heat Set Incorporated latexed finish with PP Yarn 1200 (GSM) pile ht : 3.5mm to 5.0 mm with 4-6 mm foam under lay adhesive as required complete. (MR) |
| 73 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:-W.C. pan with ISI marked white solid plastic seat and lid (DSR 2023-17.3.1) |
| 74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. (DSR 2023-17.7.4) |
| 75 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR 2023-17.31) |
| 76 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore (DSR 2023-17.16A) |
| 77 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. (DSR 2023-17.71) |
| 78 | Providing and fixing Toilet paper holder (a) C.P. brass (DSR 2023-17.34.1) |
| 79 | Providing & fixing 75mm dia vent pipes. (DSR 2023-17.35.2.2) |
| 80 | Providing & fixing of 75mm dia cast iron terminal guard. (DSR 2023-17.56.2.2) |
| 81 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter (DSR 2023-12.41.2) |
| 82 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. (DSR 2023-12.22) |
| 83 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110mm (DSR 2023-12.43.2) |
| 84 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. (DSR 2023-12.44) |
| 85 | Providing and laying cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) around P.V.C /C.I. Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground) 100mm diameter (DSR 2023-19.2.1) |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.internal work -Exposed on wall 25mm dia nominal outer dia pipes (DSR 2023-18.7.3) |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.internal work -Exposed on wall 32mm dia nominal outer dia pipes (DSR 2023-18.7.4) |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes (DSR 2023-18.8.1) |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes (DSR 2023-18.8.2) |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes (DSR 2023-18.8.3) |
| 91 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore (DSR 2023-18.51.1) |
| 92 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore (DSR 2023-18.53) |
| 93 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. (DSR 2023-18.53A) |
| 94 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore (DSR 2023-18.17.1) |
| 95 | Providing and fixing gun metal gate valve with wheel of approved quality. 32mm dia nominal bore (DSR 2023-18.17.2) |
| 96 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. (DSR 2023-2.10.1.2) |
| 97 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150mm diameter (DSR 2023-19.6.2) |
| 98 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With bricks of class M-150 (DSR 2023-19.4.2.2) |
| 99 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). bricks of class M-150 (i) For Sewer Line (DSR 2023-19.7.1.1) |
| 100 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar (DSR 2023-19.15.1) |
| 101 | Providing and fixing 150 mm S.C.I. tee at the inlet and outlet of septic tank. (DSR 2023-Code No.-7087) |
| 102 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter (DSR 2023-19.19.2.2) |
| 103 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter (DSR 2023-19.19.1.3) |
| 104 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay modular bricks of class designation M-150 (DSR 2023-19.32.1) |
| 105 | Point wiring in PVC conduit, with modulor type switch :- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with mdular type switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A (DSR 2022 E&M-1.10.3) |
| 106 | Twin Control Point wiring in PVC conduit, with modulor type switch :- Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modulor type switch, phenolic laminated sheet, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR 2022 E&M-1.11) |
| 107 | Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :-Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR 2022 E&M-1.12) |
| 108 | Power plug wiring in PVC conduit (4 x 4 Sq.Mm.) :- Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR 2022 E&M-1.13) |
| 109 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire. (DSR 2022 E&M-1.14.1) |
| 110 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (DSR 2022 E&M-1.14.2) |
| 111 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 6 sq.mm. + 1 x 6 sq.mm. Earth wire (DSR 2022 E&M-1.14.4) |
| 112 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire (DSR 2022 E&M-1.14.5) |
| 113 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 16 sq.mm. + 1 x 6 sq.mm. Earth wire (DSR 2022 E&M-1.14.6) |
| 114 | Circuit / Sub main wiring in PVC conduit :- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire (DSR 2022 E&M-1.14.10) |
| 115 | S/F light plug point piano type accessories :-Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (DSR 2022 E&M-1.29) |
| 116 | S/F power plug point piano type accessories :- Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR 2022 E&M-1.30) |
| 117 | Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 poles and earth metal enclosed plug top along with 20 amps. \\"C\\" curve, SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required. (DSR 2022 E&M-2.18) |
| 118 | S/F modular type blanking plate :- Supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (DSR 2022 E&M-1.26) |
| 119 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 20 mm (DSR 2022 E&M-1.21.1) |
| 120 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 25 mm (DSR 2022 E&M-1.21.2) |
| 121 | Supply and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required : 32 mm (DSR 2022 E&M-1.21.3) |
| 122 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' curve, miniature circuit breaker (MCB)suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole (DSR 2022 E&M-2.10.1) |
| 123 | Supplying & fixing single pole, blanking plate in the existing MCB DB complete etc. as required. (DSR 2022 E&M-2.11) |
| 124 | S/F DP MCB Isolator- Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 40 Amps (DSR 2022 E&M-2.12.1) |
| 125 | S/F DP MCB Isolator- Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amps (DSR 2022 E&M-2.12.2) |
| 126 | S/F TP MCB Isolator- Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. 63 Amps (DSR 2022 E&M-2.13.2) |
| 127 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. (DSR 2022 E&M-2.14.2) |
| 128 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. (DSR 2022 E&M-2.14.3) |
| 129 | Supplying and fixing following rating, four pole, (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensivity current upto 30 miliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required : 63 amps. (DSR 2022 E&M-2.15.3) |
| 130 | Supplying and fixing following way, SP&N, sheet steel, MCB distribution board, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator) 6 way, Double door (DSR 2022 E&M-2.3.1) |
| 131 | Supplying and fixing following way, horizontal type TP&N, sheet steel MCB distribution board, 415 V on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 12), Double door (DSR 2022 E&M-2.4.1) |
| 132 | Earthing with GI earth plate 600mm x 600 mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/ coke and salt as required. (DSR 2022 E&M-5.4) |
| 133 | Supplying and laying 25 mm x 5 mm. G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (DSR 2022 E&M-5.9) |
| 134 | Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. (DSR 2022 E&M-5.11) |
| 135 | Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required. (DSR 2022 E&M-5.15) |
| 136 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. (DSR 2022 E&M-5.16) |
| 137 | Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red colour on FRLSont side as required. (DSR 2022 E&M-2.21) |
| 138 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable (DSR 2022 E&M-1.53.2) |
| 139 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 5/6 A switch (DSR 2022 E&M-1.24.1) |
| 140 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections butexcluding modular plate etc. as required. 3 pin 5/6 A socket outlet (DSR 2022 E&M-1.24.4) |
| 141 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm) (DSR 2022 E&M-1.27.1) |
| 142 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR 2022 E&M-1.31) |
| 143 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR 2022 E&M-1.32) |
| 144 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. (DSR 2022 E&M-1.38) |
| 145 | Supplying and fixing Internet Socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (MR) |
| 146 | Installation, testing and commissioning of pre-wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. (DSR 2022 E&M-1.41) |
| 147 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep (DSR 2022 E&M-1.50.1) |
| 148 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (DSR 2022 E&M-19.1) |
| 149 | Supply of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. Catt-AAA (MR) |
| 150 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (SOR 2024-23.07) |
| 151 | Supply of LED Tube Light with Metal heavy duty Box type batten Light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect. (SOR 2024-23.09) |
| 152 | Supply of recess/surface mounting round 10 W to 15 W LED Cut out Min 125 mm, Height Min. 40mm, LED Down lighiter having powder coated die cast aluminium housing with heat shink,diffuser/reflector and driver set. suitable for 24Hr Continuous Operation, Complete in all respect. (SOR 2018-14.2) |
| 153 | Supply of 225/230mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 230 mm sweep (MR) |
| 154 | Supply, installation, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection. The panel sheet structure shall undergo seven tank pre-treatment process before painting. The sheet steel shall be all of 2.2mm thick CRCA sheet. All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers. The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm. The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections. All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable. Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places. The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters. Proper sized cable termination gland plates shall be provided on cable alleys and knockouts for same shall be provided during fabrication stage itself. The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions. A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel. Panel shall be so designed at to have minimum 20% spare feeders/space. Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement. All cable terminations shall be from top. The complete panel shall be fuse less type, for control circuits 2A/6A MCB's to be used. All bus bars shall be of aluminium, electrolytic grade only. Maximum design density shall not exceed 1 Amps/Sqmm. All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel: Incoming: One (1) No300Amp. 4 pole MCCB Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-300A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 300 A, TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. Cat-B Cubical types100 Amps TPN MCCB - 1No.63 Amps TPN MCCB - 3No.40 Amps TPN MCCB -3No.32 Amps TPN MCCB - 2 No.63 Amps TPN MCCB - 1No. Spare40 Amps TPN MCCB - 1No. Spare (MR) |
| 155 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core (SOR 2.24) |
| 156 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core (MR) |
| 157 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 4X16 sq.mm(28 mm) (DSR 2022 E&M-9.1.33) |
| 158 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 3½ X 35 sq. mm (32mm) (DSR 2022 E&M-9.1.21) |
| 159 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. (DSR 2022 E&M-18.22) |
| 160 | Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (DSR 2022 E&M-16.8) |
| 161 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. (DSR 2022 E&M-18.11.5) |
| 162 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 100 mm dia. (DSR 2022 E&M-18.14.5) |
| 163 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS) 80 mm nominal bore (DSR 2022 E&M-18.7.6) |
| 164 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS) 25 mm nominal bore (DSR 2022 E&M-18.7.1) |
| 165 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (PUMP ROOM WORKS) 100 mm nominal bore (DSR 2022 E&M-18.7.7) |
| 166 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 100mm dia (DSR 2022 E&M-18.24.2) |
| 167 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal (DSR 2022 E&M-18.10.1) |
| 168 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. (DSR 2022 E&M-18.13) |
| 169 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun metal (DSR 2022 E&M-18.16.1) |
| 170 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal (DSR 2022 E&M-18.18.1) |
| 171 | Providing and fixing standard fire mans axe with heavy duty insulated rubber handle. (MR) |
| 172 | Providing & Fixing of M.S. fire hose weather proof cabinet (750x600x250mm) made out of 16 gauge M.S. sheet capable of accommodating landing valve, hose pipes, fittings & accessories. The box shall have a front glass door with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & \\"FIRE HOSE\\" written on front. (MR) |
| 173 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe (Siamese Connection) (DSR 2022 E&M-18.19.1) |
| 174 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head (DSR 2022 E&M-18.4.2) |
| 175 | Providing & fixing of start/stop push buttons including complete connection etc. as required. (for terrace booster pump) (MR) |
| 176 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia. (DSR 2022 E&M-18.15.2) |
| 177 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal (DSR 2022 E&M-18.9.1) |
| 178 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m (DSR 2022 E&M-18.17.2) |
| 179 | Providing of FHC Door made of 16 gauge MS Sheet with frame of size 105x70mm complete door and frame assembly including all hardwares (Concealed Flush handle,Allen Key Lock, MS Hinges, 5mm Thick Float glass) & accesories . The door to be painted with fire resistance paint. The scope shall also include the painting of the frame with the same paint as the shutter or complete as per direction of Engineer-in-charge. (Approx. size of door: 900mm Wide & 1500mm Height) (MR) |
| 180 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. (DSR 2022 E&M-18.20) |
| 181 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. (MR) |
| 182 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. (MR) |
| 183 | Providing and fixing Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size including fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge. (MR) |
| 184 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Ten Loop Panel. (DSR 2022 E&M-17.2.1.1) |
| 185 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (DSR 2022 E&M-17.2.4) |
| 186 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. (DSR 2022 E&M-17.2.5) |
| 187 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. (DSR 2022 E&M-17.2.14) |
| 188 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. (DSR 2022 E&M-17.2.6) |
| 189 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. (DSR 2022 E&M-17.2.7) |
| 190 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. (DSR 2022 E&M-17.2.10) |
| 191 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required. (DSR 2022 E&M-17.1.8) |
| 192 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (DSR 2022 E&M-17.5.2) |
| 193 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All Types of Soil 350 mm dia (DSR 2023-23.1.1.2) |
| 194 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. Rocky strata including Boulders 350 mm dia (DSR 2023-23.2.1.2) |
| 195 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm (DSR 2023-23.10.2) |
| 196 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia (DSR 2023-23.11.3) |
| 197 | Supplying, filling, spreading & leveling gravels of size range 1.5 mm to 2 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. Around Pipe (3.14*0.15*0.15*150.00) (DSR 2023-23.7) |
| 198 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (3.14*3.50*3.50*0.30) (DSR 2023-23.8) |
| 199 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tube well, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR 2023-23.12) |
| 200 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia (DSR 2023-23.13.2) |
| 201 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp (DSR 2023-23.14.2) |
| 202 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 150 mm dia (DSR 2023-23.15.2) |
| 203 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore (DSR 2023-18.12.8) |
| 204 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 10 x 4 sq. mm |
| 205 | Supply of Submersibule pump with control panel, support wire etc. complete 5.0 H.P. (KSB / EQ.) |
| 206 | Ceiling Mount Speaker ( Front Left & Right ): 15\\" Passive FOH SpeakerThe scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of Ceiling Mount Speakers (Front Left & Right): 15\\" Passive FOH Speakers by skilled manpower to ensure high-quality performance and integration.The speakers shall be of 2-way bass reflex type, covering a frequency range (-10dB) of 50Hz-20kHz with nominal coverage of 90° x 40° for optimal sound dispersion. Components include a 15\\" cone driver and a 1.75\\" titanium voice coil compression driver with a CD horn, ensuring clear and balanced audio output.Each unit shall have a PGM 500W power rating, delivering reliable performance with 98dB SPL (sensitivity at 1W, 1m on axis) and a nominal impedance of 8Ω, making it compatible with standard amplification systems.Installation shall be carried out by experienced professionals, followed by comprehensive testing and commissioning to verify performance. Onsite training and calibration will be provided to designated personnel, ensuring proper system operation and optimization. |
| 207 | The scope involves the Supply, installation, and hanging of a Line Array Loudspeaker Cluster System consists of multiple individual speakers arranged in a linear formation designed for optimal sound coverage, ensuring that the entire audience, from front row to rear seating, receives clear audio. The project includes the onsite fabrication and precise positioning of Two-Way Line Array clusters, utilizing advanced coverage mapping to achieve the correct angles and position for effective sound distribution. The setup should incorporate the necessary hardware to mount the Front of House (FOH) Line Array Loudspeaker Cluster, mounted in front of the proscenium arch using the required hardware, without obstructing the audience's view involve specialized mounts, rigging hardware, and a Suspension Frame Arrangement, as recommended by the OEM, to ensure the safety and optimal placement of the speakers. The hanging arrangement will be designed with a gearbox for easy vertical movement of the cluster in the future, if repairs or adjustments are needed. The lifting mechanism will employ a winch with recommended galvanized steel wire rope slings for added safety, considering the additional overhead load, An overhead fabricated frame should also be included, designed to facilitate the smooth and secure movement of the Line Array Cluster using a winch mechanism, Speaker Mount & Riging Hardware For Front Speaker: Speaker mounts and rigging hardware are used to ensure the optimal placement of an audio speaker specifications considered within the specified make and standards, any deviations from this standard will not be accepted, All products must come with an unconditional warranty covering a minimum of one year maintenance of the installed equipment. |
| 208 | Floor Monitor Speaker :12\\" Passive Stage MonitorThe scope of work includes the supply, installation, testing, and commissioning of a 12\\" Passive Stage Monitor Speaker with a 2-way bass reflex design for professional audio applications. The speaker shall have a frequency range (-10dB) of 55Hz-20kHz, nominal coverage of 40° x 90°, and high-performance components, including a 12\\" cone driver and 1.75\\" titanium voice coil compression driver with a CD-Horn. It shall have a power rating of PGM 400W, sensitivity (1W; 1m on-axis) of 97dB SPL, and nominal impedance of 8Ω, ensuring optimal efficiency and reliability.The work shall also include on-site training for operational personnel and calibration of the installed system through skilled manpower, ensuring precise tuning for optimal performance. The installation and commissioning shall comply with industry standards to guarantee long-term durability and functionality. |
| 209 | Power Amplifier for, main Speaker & subwoofers : Power Amplifier for FOH The scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a Power Amplifier for FOH and Subwoofers, carried out by skilled manpower to ensure efficient integration and peak audio performance.The amplifier shall deliver 2x 1000W at 8Ω and 2x 1200W at 4Ω, providing robust and dynamic sound reinforcement for main speakers and subwoofers. It shall feature a newly developed Class-D amplifier engine with a custom LSI, ensuring high efficiency and superior output quality.The unit shall include flexible onboard PEQ, crossover, filters, delay, and limiter functions, allowing precise control over audio settings for optimized system performance. Additionally, it shall support Yamaha speaker presets and provide utilities for safe and secure operation to ensure reliability under various conditions.The amplifier shall offer an output power of 1kHz Non-clip 20msec Burst (both channels driven) with ratings of 1000W x 2 at 8Ω, 1200W x 2 at 4Ω, and 700W x 2 at 2Ω, ensuring stability across different load conditions.Installation shall be performed by trained professionals, followed by comprehensive testing and commissioning to validate performance and adherence to technical specifications. Onsite training and calibration shall be provided to designated personnel to facilitate proper operation and system optimization. |
| 210 | Subwoofer : 18\\" Passive SubwooferThe scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of 18\\" Passive Subwoofer by skilled manpower to ensure optimal performance and seamless integration into the audio system.The subwoofer shall be of bass reflex type, offering deep and impactful low-frequency response. The frequency range (-10dB) shall be 32Hz - 3kHz (Passive), 32Hz - 150Hz (Normal), and 29Hz - 150Hz (Extend mode), ensuring flexibility across different operational settings.The components shall include an 18\\" cone driver with a 4\\" voice coil and ferrite magnet, designed for high power handling and efficient sound reproduction. The speaker shall have a power rating of 1000W (EIA 426-A), providing robust performance. SPL sensitivity shall be 100dB (1W at 1m on axis), while the peak SPL shall reach 133dB, ensuring high-impact bass output. The nominal impedance shall be 8Ω, allowing compatibility with standard audio configurations.Installation shall be executed by trained professionals, followed by rigorous testing and commissioning to validate performance and adherence to technical standards. Onsite training and calibration shall be conducted to ensure proper operation and optimization, enabling designated personnel to maintain system efficiency effectively. |
| 211 | Delay Speaker ( Left & Right ) :8\\" Delay SpeakersThe scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of 8\\" Delay Speakers, carried out by skilled manpower to ensure seamless integration and optimal sound distribution.The speakers shall be 2-way, bass-reflex type, providing an extended frequency range (-10dB) from 51Hz to 20kHz, ensuring clear and balanced audio reproduction. The nominal coverage of H (100°) x V (100°) allows uniform sound dispersion, making them suitable for delay applications.Each unit shall feature an 8\\" cone driver and a 1\\" soft dome tweeter, ensuring clarity and precision across frequencies. The speakers shall have a power rating of 180W, delivering reliable performance. The nominal impedance shall be 8Ω, with additional configurations of 60W (170Ω), 30W (330Ω), and 15W (670Ω), ensuring compatibility with various setups. The sound pressure level (SPL) shall reach 117dB, providing sufficient output for effective delay speaker operation.Installation shall be carried out by experienced professionals, followed by comprehensive testing and commissioning to verify functionality and ensure compliance with technical specifications. Onsite training and calibration shall be provided to designated personnel to ensure proper system operation, maintenance, and optimization. |
| 212 | Power Amplifier : Power Amplifier for Dealy SpeakerThe scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a Power Amplifier for Stage Monitors, carried out by skilled manpower to ensure reliable integration and optimal performance.The amplifier shall deliver 2x 800W at 8Ω and 2x 1050W at 4Ω, providing powerful and efficient sound reinforcement for stage monitor speakers. It shall feature a newly developed Class-D amplifier engine with a custom LSI, ensuring high efficiency and superior output quality.Equipped with flexible onboard PEQ, crossover, filters, delay, and limiter functions, the amplifier allows precise audio control for optimized system performance. It shall also support speaker presets and provide utilities for safe and secure operation, ensuring dependable functionality.The amplifier shall operate with a sampling frequency rate of 48kHz, utilizing 24-bit linear A/D and D/A converters with 128 times oversampling for high-resolution audio processing. It shall maintain total harmonic distortion levels of 0.1% at 1kHz (10W) and 0.3% at 1kHz (half power), ensuring clean sound output. The frequency response shall be ±1.0dB (1W, 8Ω, 20Hz to 20kHz), providing accurate and well-balanced audio reproduction.Installation shall be carried out by trained professionals, followed by comprehensive testing and commissioning to validate performance and compliance with technical specifications. Onsite training and calibration shall be provided to designated personnel, ensuring proper operation and system optimization. |
| 213 | Supply, installation, testing, commissioning, onsite training, and calibration of a high-performance digital audio signal processor for auditorium use, executed by skilled and certified manpower. The unit shall support (3) analog line inputs and (2) AES digital inputs via shared connectors, along with (1) RTA microphone input,using electronically balanced and RF-filtered female XLR connectors. Input impedance shall exceed 30 kΩ, with a max input level of +28 dBu and CMRR >50 dB @ 1 kHz. Phantom power of +48 VDC shall be provided for the RTA mic. The processor shall offer (6) electronically balanced line outputs via male XLR connectors, with 120 Ω output impedance and +22 dBu max output level. Each output shall support alignment delay up to 1000 ms. The unit shall feature 24-bit A/D and D/A converters with dbx Type IV™ conversion, delivering dynamic ranges up to 129 dB (A-weighted) and internal 32-bit floating point processing. Supported sample rates include 48/96 kHz,scalable to 192 kHz. System performance shall include 114 dB dynamic range, 0.0025% THD+Noise, 20 Hz–20 kHz frequency response, and latency as low as 2.15 ms. Operating voltage shall be 100–240 VAC, 50/60 Hz,with power consumption not exceeding 18 W. The contractor shall provide complete onsite training, calibration,and documentation in line with manufacturer standards and industry best practices |
| 214 | Analog Mixer :24 Channel Analog MixersThe scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a 24-Channel Analog Mixer, executed by skilled manpower to ensure seamless integration and optimal sound control.The mixer shall feature 24 mixing channels, comprising 16 mono and 4 stereo line inputs, delivering versatile audio routing capabilities. It shall be equipped with 4 GROUP buses plus an ST bus, allowing efficient grouping and mixing flexibility.The unit shall include 6 AUX sends and 2 FX sends, ensuring adaptable signal distribution for external processing and effect integration. Additionally, it shall provide 1 matrix output, expanding routing capabilities for complex configurations.For onboard processing, the mixer shall feature FX1: REV-X with 8 program selections and parameter control, alongside FX2: SPX with 16 program options and parameter control, offering a comprehensive range of effects for audio enhancement.Installation shall be conducted by experienced professionals, followed by rigorous testing and commissioning to validate system performance and adherence to technical standards. Onsite training and calibration will be provided to designated personnel, ensuring proper operation, maintenance, and optimization of the mixer for professional use. |
| 215 | Wired Microphone : The scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a wired microphone, carried out by skilled manpower to ensure reliable operation and seamless integration into the audio system.The microphone unit shall be dynamic with a unidirectional polar pattern, ensuring focused sound capture with minimal background noise. It shall offer a frequency response of 40Hz–15kHz, providing clarity and precision for vocal and instrument applications.The microphone shall have a sensitivity rating of -54dB ±3dB (0dB = 1V/Pa at 1kHz) and an output impedance of 500 ohms ±30% (at 1kHz), ensuring compatibility with standard audio equipment. The connector type shall be 3-pin XLR-M, facilitating secure and professional-grade connectivity.The unit shall be supplied with a Φ6mm x 5m cable featuring an XLR-F type connector and a 6.3mm plug, ensuring flexibility for various audio setups.Installation shall be conducted by experienced professionals, followed by rigorous testing and commissioning to validate system performance and adherence to technical standards. Onsite training and calibration will be provided to designated personnel, ensuring proper operation, maintenance, and optimization of the mixer for professional use. |
| 216 | Handheld Wireless Microphone: The scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a Professional Handheld Wireless Microphone System, carried out by skilled manpower to ensure flawless performance and seamless integration into the audio setup.The system shall feature 8 selectable UHF channels, ensuring interference-free and stable transmission for reliable operation in various environments. It shall be equipped with a high-clarity microphone, offering exceptional sound quality and ease of use, making the BR 28/BM 28 a strong value proposition.The microphone system shall operate on UHF Band frequency utilizing PLL-Synthesis Technology, ensuring accurate frequency stability and enhanced signal reliability.Installation shall be conducted by trained professionals, followed by comprehensive testing and commissioning to validate operational efficiency and adherence to technical specifications. Onsite training and calibration shall be provided to designated personnel to ensure proper handling, usage, and system optimization for peak performance. |
| 217 | Lapel UHF wireless microphone : The scope of work includes the supply, installation, testing, commissioning, onsite training, and calibration of a Professional Lapel UHF Wireless Microphone System, carried out by skilled manpower to ensure optimal performance and seamless integration into the audio setup.The system shall feature UHF wireless microphone technology, engineered for high-quality performance across various applications, ensuring clear and reliable audio transmission. This UHF wireless series shall provide unprecedented flexibility and versatility, making it suitable for professional use.The microphone system shall operate on a superior quality UHF band frequency, delivering stable signal transmission with minimal interference. It shall offer 100 UHF selectable channels, allowing for adaptability in different environments and ensuring a secure and interference-free audio experience.Installation shall be carried out by trained professionals, followed by rigorous testing and commissioning to validate functionality and adherence to technical standards. Onsite training and calibration shall be provided to designated personnel to ensure proper operation, maintenance, and optimization of the wireless microphone system. |
| 218 | GOOSNECK MICROPHONE :The work includes the supply, installation, testing, and commissioning of a Gooseneck Microphone, designed for professional audio applications. The microphone shall have a frequency range of 50 Hz to 18 kHz, ensuring clear vocal reproduction with minimal interference. It shall support a maximum SPL of 120 dB, an impedance of 100 Ohms, and a sensitivity of -38 dB, providing excellent responsiveness and audio clarity. The unit shall operate within a voltage range of 12 to 48V, ensuring compatibility with standard audio systems. The microphone shall have a compact base with dimensions of H: 3.3 cm x W: 8.64 cm x L: 14.22 cm, and an 18-inch flexible gooseneck, allowing precise positioning for optimal sound capture. The installation shall include on-site training for operational personnel and calibration by skilled manpower to ensure optimal performance. All work shall be carried out in compliance with industry standards, guaranteeing reliability and durability in professional environments. |
| 219 | PA Powered Lectern System Powered Podium: The scope of work includes the supply, installation, testing, and commissioning of a PA Powered Lectern System Powered Podium designed for professional presentation and public address applications. The system shall feature a built-in 60 Watts amplifier with a 4 Ohms output, ensuring clear and powerful sound reinforcement. It shall incorporate three 4-inch woofers and one 2-inch tweeter, delivering high-quality audio output with balanced frequency response.For versatile communication, the podium shall have a built-in dual wireless microphone system, supporting either two handheld microphones or one handheld and one tie microphone. Additionally, it shall be equipped with two flexible gooseneck microphones for clear speech reproduction and a reading lamp for enhanced visibility. The unit shall support external speaker connections for expanded audio coverage. The system shall feature a foldable laptop table for ease of use during presentations and an in-built USB player with Bluetooth connectivity and a recording facility, ensuring seamless media integration. The installation shall include on-site training for operational personnel and calibration through skilled manpower, ensuring optimal performance in professional settings. All work shall adhere to industry standards for reliability and durability. |
| 220 | Equipment Rack : The scope of work includes the supply, installation, testing, and commissioning of an Equipment Rack, designed for housing all rack-mountable equipment securely and efficiently. The rack shall feature internal wiring for seamless connectivity, a front glass door for easy monitoring of installed equipment, and heat dissipation fans to ensure optimal thermal management.For ease of movement and flexibility, the unit shall be equipped with durable movement wheels and an integrated power distribution unit, ensuring organized and efficient power management. The installation shall include on-site training for operational personnel and calibration by skilled manpower, ensuring proper setup and functionality. The entire process shall be carried out following industry standards to guarantee reliability and long-term performance in professional environments. |
| 221 | Providing & Fixing of Speak on Cable Connectors with industry Standard Specification for Professional- Grade audio connectivity, designed to transmit audio signals from amplifiers to loudspeakers. These connector are specifically engineered for heavy duty amplifier- loudspeaker applications, such as professional touring, ensuring reliable and high-quality audio performance . The connectors shall be extremely rugged,durable, and capable of with standing rough handling and continuous use, ensuring a secure and uninterupted signal transmission between amplifiers and loudspakers. The installation must be carried out with percision, following all relevant industry standards to ensure optimal functonality and longevity. |
| 222 | SITC Ultra-Light Boom Microphone Stand :Microphone boom stand combines the crucial elements of lightweight durability with an attractive and functional design. This collapsible tripod boom stand has a sturdy die-cast and steel construction that offers superior resiliency with great flexibility of positioning, so it's always convenient and never conspicuous. Its glossy black finish ensures an elegant yet unobtrusive presence and its lightweight design enables maximum portability. Perfect for on-the-go musicians, performance venues or studios, the BL3 provides the strength you need with the portability you crave |
| 223 | Supply, installation, testing, commissioning, programming, and calibration of SITC Professional Stereo reengineered headband and earcup assembly form more ergonomic fit help block out external noise : 40mm neodymium dynamic drivers, Wide frequency range delivers full bass and detailed highs, Optimized performance for use with most pro and consumer audio devices, Closed-back, circumneutral design rests comfortably over the ears and reduces background noise, Legendary Shure quality to withstand the rigors of everyday use, Replaceable ear cup pads, Includes threaded 1/8\\"-1/4\\" adapter, Transducer Type: Dynamic, Neodymium magnet, Driver Size: 40 mm, Frequency Range: 20 Hz - 20,000 Hz, Sensitivity (@ 1 kHz) : 107 dB/mW, Impedance (@ 1 kHz) : 38 ohms, Maximum Input Power: 500 mW, Connector: Gold-plated 3.5 mm (1/8 in.) stereo mini jack with 6.35 mm (1/4 in.) threaded adapter, Cable Length/Type: 2 meters (6.56 ft.) / attached, straight, oxygen-free copper, with Removable Ear Pads as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete. |
| 224 | Supply, installation, laying, testing, commissioning, and programming of the Super Pocket Stage Box, which includes a Full Stage Pocket designed to hold low-voltage connectors for six low-voltage devices (6 XLR) or two SPEAKON connectors. The Super Pocket is customized for six or more audio signal connections. The product must be delivered fully calibrated and ready for immediate use. Installation must align with the Architectural Drawings and instructions provided by the Engineer-in-Charge (EIC). The Floor Box assemblies should feature a flip cover, a female 6-pin connector chassis panel mount balanced XLR socket with a push mechanism, and two SPEAKON male chassis connectors with a locking system. Installation must be carried out by a skilled and experienced team, adhering to the highest standards of quality, precision, and safety. The Modular CONNECT Panels must accommodate AV connectors, with a panel configuration designed to protect connectivity from damage and dust by positioning connections upright. Termination should be completed before or after pocket installation to support multiple connections. The floor box should include a secondary small door that closes shut when not in use, preventing wires from getting stuck. A standard black finish is required, and higher or improved specifications are welcome, provided they meet or exceed the specified standards. Deviations from these standards will not be accepted. |
| 225 | Snake Cable Long drum: 16 Pair Bulk CL-2 Multi-pair Snake Cable Each channel is 24 gauge, individually shielded, jacketed and numbered. Meets NEC Code for permanent installation. Cables are built with the hard-working, hard-touring musician or audio professional in mind. cables are exceedingly high-quality cable lines in the fix installations and live shows for their durability and excellent performance. |
| 226 | Providing Fixing & Laying Speaker Cable 2 Core x 1.5 Sq. mm 100/40 using PVC Electrical Conduit Pipes as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete:2 core 1.5 sq mm PVC Insulated loudspeaker cable Conductor 30x0.25 mm O.F.C. (Oxygen Free Copper) Conductor resistance @ 20°C: 12 Ohm/Km Capacitance @ 1 KHz: 115 pF/mt Nominal OD 7.00 mm working temperature -20 °C / +70 °C Minimum bending radius: 10 x overall diameter Nominal Capacitance between Conductors 115 pF/m @1KHz PVC Matt , Use for all audio applications with Double Diamond Protection Highest quality stranded copper wire for maximum flexibility and covered with a tough PVC jacket to help prevent chafing ,Wire should be designed to maximize sound quality and for better frequency response. |
| 227 | Providing Fixing & Laying Speaker 2 Core x 2.5 Sq. mm 200/40 using PVC Electrical Conduit Pipes as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete:Cable with thickness of 2 core 2.5 sq mm PVC Insulated loudspeaker cable Conductor 48x0.25 mm O.F.C. (Oxygen Free Copper) Conductor resistance @ 20°C: 7.4 Ohm/Km Capacitance @ 1 KHz: 131 pF/mt Nominal OD 8.40 mm working temperature -20 °C / +70 °C Minumum bending radius: 10 x overall diameter Nominal Capacitance between Conductors 131 pF/m @1KHz PVC Matt Use for all audio applications with Double Diamond Protection Highest quality stranded copper wire for maximum flexibility and covered with a tough PVC jacket to help prevent chafing, Wire should be designed to maximize sound quality and for better frequency response |
| 228 | Providing Fixing & Laying balanced shielded microphone cable 2 core 24AWG ( 30 x 0.10 mm ) bare copper O.F.C. (Oxygen Free Copper) using PVC Electrical Conduit Pipes as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete: Professional balanced Shield: Spiral copper 16x5x0.10 mm > 90% PVC Microphone cable Insulation: PE (Compact polyethylene) Ø 1.60 mm - RED/WHITE Working Temperature :20 °C / +70 °C Electrical resistance: 93 Ohm/Km (conductor) @ 20°C & 20 Ohm/Km (shield) @ 20°C Electrical capacitance: 46 pF/m (conductor/conductor) @ 1 KHz & 90 pF/m (conductor/shield) @ 1 KHz Nominal OD : 6.3/6.5 mm Minimum bending radius: 20 x cable section radius Attenuation : 0.50 db/100m PVC Matt balanced shielded Roll Reel of microphone cable, Balanced and shielded with rope braiding to give cable substantial strength while retaining extreme flexibility & Great for building custom length mic cables, custom patch coded or other audio applications that require either a stereo or balanced signal. |
| 229 | Providing Fixing & Laying balanced shielded microphone cable 2 core 24AWG ( 30 x 0.10 mm ) bare copper O.F.C. (Oxygen Free Copper) using PVC Electrical Conduit Pipes as per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete: Professional balanced Shield: Spiral copper 16x5x0.10 mm > 90% PVC Microphone cable Insulation: PE (Compact polyethylene) Ø 1.60 mm - RED/WHITE Working Temperature :20 °C / +70 °C Electrical resistance: 93 Ohm/Km (conductor) @ 20°C & 20 Ohm/Km (shield) @ 20°C Electrical capacitance: 46 pF/m (conductor/conductor) @ 1 KHz & 90 pF/m (conductor/shield) @ 1 KHz Nominal OD : 6.3/6.5 mm Minimum bending radius: 20 x cable section radius Attenuation : 0.50 db/100m PVC Matt balanced shielded Roll Reel of microphone cable, Balanced and shielded with rope braiding to give cable substantial strength while retaining extreme flexibility & Great for building custom length mic cables, custom patch coded or other audio applications that require either a stereo or balanced signal. |
| 230 | Supply, installation, testing, commissioning, onsite calibration, and end-user training by skilled manpower of Sony 3LCD Laser Projector featuring Bright Era technology and a native resolution of WUXGA (1920×1200, 16:10). The projector shall deliver 5,300 ANSI lumens brightness (up to 5,800 lm center) with dynamic infinite contrast, and incorporate laser phosphor light source with a lifespan of up to 20,000 hours. Optics to include manual 1.6× zoom, throw ratio 1.23:1–1.97:1, and lens shift vertical ±35–55%, horizontal ±15%, supporting image sizes from 40″ to 300″ diagonal. Keystone correction shall be ±30° both vertically and horizontally. The system shall support resolutions up to 4K (4096×2160 at 60 Hz). Connectivity includes HDMI x2, VGA, HDBaseT, composite video, USB Type-A, LAN, RS-232, and audio I/O, with built-in 16 W mono speaker. The projector shall operate at 100–240V AC, with max power consumption of 463W, fan noise ≤35 dB, and built-in dust-proof optical engine. Complete with all accessories and executed as per manufacturer standards and instructions of the Engineer-in-Charge. |
| 231 | Universal Projector Ceiling Mount: Universal Projector Wall orCeiling Mount - Adjustable Angle and H: * Cold-Rolled steel material; Durable construction * Fits most projector brands (mounting holes on projector max. 12.3\\") * 2-In-1 design can be installed as a Flush mount or Telescopic with height adjustment 14.9\\" - 24.4\\" * Angle adjustments: Tilt and rolls Plus or minus 15 degrees90 degrees swivel adjustment* Features cable management to conceal HDMI, audio, video cables. |
| 232 | Optical High-Defination Multimedia Interface Cable: 50'Meter’ UltraHigh Speed Equalizer HDMI Cable FULL HD 3D Shielded High SpeedCable for Audio Video HDMI Cord Support HD 3D 4K, With Ethernet - Supports 3D & Audio Return Channel with MULTI- FUNCTIONAL SUPPORT - Lintek HDMI A Male to A Male Cable Supports 3D | HD 2K @ 1080p | QHD @ 1440p | UHD 4k @ 2160p (up to 60 Hz over HDMI 2.0 HDMI 2.0 connection). |
| 233 | Supply and execute the installation of high-performance Copper CAT 6A Structured network cables for structured cabling, ensuring seamless data transmission for the operation of the Audio System, Live Streaming Cameras, Projection, and Large Format Video Wall connectivity inside the auditorium. The installation shall also include standby points inside the auditorium and stage area, as required, to ensure all equipment remains operational. The entire cabling work shall be executed using PVC Electrical Conduit Pipes as per the approved architectural drawings. The execution shall strictly adhere to the instructions of the Engineer-in-Charge (EIC) and include all necessary tools, machinery, manpower, staging, and any required consumables to achieve a complete and functional system. The CAT 6A cables utilized in this project shall be designed to support high-speed data transmission with enhanced performance, capable of transmiƫng digital and analogue voice and video (RGB) signals over LAN networks. The system shall support Gigabit Ethernet (10GbaseT) standard and operate at a bandwidth of 500 MHz, ensuring the highest quality signal integrity and performance for all connected systems within the auditorium. The work shall be carried out by a team of skilled professionals with relevant experience in structured cabling and network installations, ensuring proper routing, termination, and testing of cables to meet industry standards, cables provided and installed must comply with Category 6A specifications. The system shall include 4-pair unshielded twisted pair (UTP) cables featuring a 23 AWG solid copper conductor with a frequency of 500 MHz.the cables shall be supplied in an easy-to-pull box to facilitate smooth and efficient installation while minimizing material wastage. All cables shall be routed through designated PVC conduits, securely fastened, and labeled appropriately for ease of identfication. The work shall be executed within the stipulated timeline, maintaining the highest standards of quality and safety throughout the installaion process. |
| 234 | The scope of work providing & execute the installation of a 4K HDMI Extender Balun HDBaseT UltraHD 4K @ 60Hz 4:4:4 Over Single CAT6 A Cable with HDR, CEC & IR Control, RS-232 - Up to 400 Ft - Loop Out - Power Over Cable - Audio Out (UHD-EXB400R-K) to facilitate the seamless transmission of high-quality HDMI signals for large-format projection through a professional cinematic projector. Ensuring zero signal loss and maintain superior picture quality, adhering to the highest standards of performance and reliability, to ensure the highest quality and minimal signal degradation, equipment shall be compatible with a wide range of media sources, including but not limited to PCs, gaming consoles, Blu-ray players, media players, satellite boxes, Android boxes, and Sky HD boxes, providing flexibility for various applications, Extender shall feature Power Over Cable (POC) technology, which allows system to be powered through a single power adapter connected at the transmitter (TX) terminal, reducing additional power supply requirements and simplifying installation if required. System must be fully plug-and-play without the need for additional drivers or software. It shall also incorporate an IR Loop Out function to support seamless remote control signal transmission to achieve the highest level of signal integrity, the installation must utilize shielded CAT6/7 cables. |
| 235 | The scope of work entails the supply, installation, laying, testing and commissioning of a Modular Wired Fixed Heavy-Duty Stage Lighting Bar System for an auditorium stage & Front of House Area with submission of detailed drawings, ensuring optimal lighting effects and focus across the performance area, lighting bar system, constructed from high-quality Mild Steel (MS) tubing of 2\\"x 4\\" x 16-gauge diameter, features a full-length 20ft pipe interconnected with 2\\" square and round pipes compatible with C-Clamps Safety Hang trussing, ensuring structural integrity, bars are modular, allowing them to be linked side by side to form a single, rigid structure, and can be suspended using existing grid system. The MS fabrication will utilize materials from approved manufacturers such as TATA, JINDAL, KAMDHENU, and APOLLO, treated with rust prevention measures including wire brushing, sanding, zinc chromate red oxide primer, and a final coat of black quick-drying enamel paint for a sleek, professional finish, installation includes an integrated power system using 2.5mm cables connected to 16A Industrial SCHUKO sockets for European-standard safe power supply and outlets placements should be built into the bars with DMX signal outlets and connectors are incorporated installation will be executed by a skilled and experienced team in strict accordance with the Architectural Drawings and the Engineer-in-Charge's (EIC) instructions, ensuring adherence to the highest standards of quality, precision, and safety. The lighting bars, designed for flexibility and extensive coverage, will be hung over the stage on a safety grid, allowing for the optimal placement of lighting fixtures to achieve the desired effects and atmosphere. The final installation must include comprehensive onsite training for the end-user to ensure proper operation and maintenance, with all products covered by an unconditional warranty of at least One year. Specifications exceeding the mentioned standards are encouraged, provided they align with the specified makes and standards, with no deviations accepted. |
| 236 | The scope of work encompasses the supply, installation, laying, testing and commissioning of a modular wired fixed heavy-duty vertical stage lighting bar ladder system for the stage. This system is to be installed on both sides of the stage, ensuring optimal lighting effects and focus across the performance area. The lighting bars, constructed from 2\\" x 2\\" x 16-gauge mild steel tubes with a 6 ft length, will be interconnected with trussing using adequate clamps and securely hung from the existing grid systems for maximum flexibility. The installation must adhere to the design specifications and be carried out by a skilled team, ensuring strict compliance with the Architectural Drawings and instructions from the Engineer-in-Charge (EIC). The mild steel bars shall undergo a thorough rust-free treatment, including wire brushing or sanding to prepare the surface, followed by two coats of zinc chromate red oxide primer for anti-corrosion protection. The bars will be finished with a sleek, black, quick-drying enamel paint, both inside and outside, to complement the stage environment. The bars will accommodate built-in power with 2.5mm cables connected to 16A industrial SCHUKO sockets, along with DMX signal outlets, ensuring seamless integration with lighting fixtures for precise control and effects. MS material must meet the approved makes (TATA, JINDAL, KAMDHENU, APOLLO) and adhere to the highest standards of quality, precision, and safety. Higher or improved specifications beyond those mentioned are encouraged, provided they meet the specified make and standards, with no deviations accepted. The delivered product must come fully calibrated, ready for immediate use, and include an unconditional one year warranty. Comprehensive onsite training must be provided to the end-user to ensure proper operation and maintenance of the installed equipment, ensuring the system's long-term effectiveness and reliability. The scope of this specification covers the MS (Mild Steel) fabrication work only. The cost associated with wiring and connectors is not included in this specification. |
| 237 | The scope of work encompasses the supply, installation, laying, testing, commissioning, and programming of 4 Eyes 200W LED Light fixtures designed to focus on the stage from the Front of House (FOH) and equal wash on stage from overhead and vertical side bars on stage, fixtures should be equipped with four advanced 50W COB 2-in-1 LED chips, offering a choice between a crisp cool white at 5600K and a warm, inviting 3200K white, ensuring flexibility in lighting design to suit various performance requirements. The dimming capability, ranging from 0 to 100% across 12 channels, allows precise control over light intensity, contributing to the creation of different moods and scenes on stage to provide uniform and diffused light, ensuring consistent, flicker-free illumination across the entire stage, effectively eliminating harsh shadows and minimizing glare to reduce eye strain for both performers and the audience installed fixture can connect multiple lights in series, and they must meet the latest CE and ROH certification standards, as well as incorporate DMX signal loop in and out through 3 or 5-pin XLR connectors, ensuring seamless integration with the lighting console, with an IP22 protection class and an impressive LED lifespan of over 100,000 hours with minimal maintenance. The beam angle of 15-25-45-60° allows for versatile lighting effects, fixtures are constructed from durable die-cast aluminum. The installation will be executed in strict accordance with the architectural drawings and Engineer-in-Charge (EIC) instructions, requiring placement drawings of fixtures before commencing work, All necessary tools, machinery, manpower, and consumables will be provided to ensure a comprehensive and seamless process, with the installation carried out by a skilled and experienced team adhering to the highest standards of quality, precision, and safety. The proposed products must be delivered fully calibrated and ready for immediate use, with an unconditional warranty covering a minimum of one year. Additionally, comprehensive onsite training will be provided to the end-user to ensure proper operation and maintenance of the installed equipment. Any deviation from the specified standards will not be accepted, but higher or improved specifications beyond those mentioned are welcome and will be considered, provided they align with the project’s requirements and standards. |
| 238 | The scope of work encompasses the supply, installation, laying, testing, commissioning, with programming of RGBW 54 x 3W LEDPAR fixtures, specifically designed for installation on auditorium stages to maximize visibility and create the perfect stage atmosphere for performing arts, LEDPAR lights with high efficiency, extended lifespan, minimal maintenance, low heat generation, and absence of UV output, ensuring optimal performance with user-friendly operation. The fixtures must feature DMX signal compatibility with loop-in and loop-out functionality through 3 or 5-pin XLR connectors, supporting seamless integration with the lighting console to enable precise control of each fixture from a single command, as per the lighting program. The proposed LEDPAR fixtures, constructed from durable aluminum alloy, with an input power of 150W, operating on AC100-240V 50/60Hz. The lamps must consist of 54 x 3W LEDs with a color system of RGBW 4-in-1, offering control through 4/8 channel modes and multiple operational modes including DMX512, Master/Slave, Auto Run, and RDM. With an average lifespan exceeding 50,000 hours and the ability to operate in temperatures ranging from -20℃ to 40℃, these fixtures must meet or exceed the specified standards, including CE certification, and any deviation will not be accepted. The installation will adhere strictly to the Architectural Drawings and Engineer-in-Charge (EIC) instructions, requiring placement drawings of fixtures prior to commencing work. The process will involve all necessary tools, machinery, manpower, staging, and consumables, executed by a skilled and experienced team committed to the highest standards of quality, precision, and safety. The proposed products must be delivered fully calibrated and ready for immediate use, accompanied by comprehensive onsite training for the end user to ensure proper operation and maintenance. All products must come with an unconditional warranty covering a minimum of one year, guaranteeing reliability and longevity in entertainment applications. |
| 239 | The scope of work includes the supply, installation, laying, testing, commissioning, and programming of 200W COB W + WW LED PAR fixtures, specifically designed for fixed installation, COB lights are integral to achieving the desired lighting effects, maximizing visibility, and creating an immersive stage atmosphere. Each fixture must deliver high efficiency, an extended lifespan, minimal maintenance, low heat generation, and no UV output. The proposed fixtures must be fully calibrated upon delivery and compatible with advanced lighting consoles, responding seamlessly to DMX signals through 3 or 5-pin XLR connectors, with loop in and loop out capabilities. The lighting fixtures should support control modes including DMX512, master-slave, voice, and self-propelled, with dimming capabilities ranging from 0-100%, and color temperatures of 3200K or 5600K, or RGB for versatile stage effects. The fixtures must feature a die-cast aluminum chassis, beam angles between 15° and 60°, and a power rating of 250W. They should operate reliably within a temperature range of -30°C to 40°C, with a working lifetime of up to 60,000 hours. The installation must be carried out by a skilled team, strictly adhering to the highest standards of quality, precision, and safety, as per the architectural drawings and Engineer-in-Charge (EIC) instructions. This includes the provision of all necessary tools, machinery, manpower, and consumables, ensuring a seamless process. The fixtures must comply with CE and RoHS certifications, and any deviations from these standards will not be accepted. All products must include an unconditional warranty covering a minimum of one year, and comprehensive onsite training must be provided to the end-user to ensure proper operation and maintenance. Detailed placement drawings of fixtures are required before work assignment to ensure the right design and end result. Any proposed product exceeding the specified requirements will be considered, while any that fall short will be rejected. |
| 240 | The scope of work includes the supply, installation, laying, testing, commissioning, and programming of COB LED Blinder Light 400W with four COB lamps on the auditorium stage, ensuring comprehensive coverage and achieving desired lighting effects that maximize visibility. The installation will be meticulously executed following the Architectural Drawings and instructions provided by the Engineer-in-Charge (EIC), with a strong emphasis on quality, precision, and safety. The project demands a highly skilled and experienced team equipped with all necessary tools, machinery, manpower, staging, and consumables. The proposed COB LED Blinder Light is a highperformance stage luminaire, featuring four 100W COB LED bulbs totaling 400W, delivering adjustable luminous color between 3000K and 5600K. It offers a beam angle of 26° to 35°, ensuring broad and well-distributed illumination across the stage or audience area, crucial for focused lighting effects that enhance the performance atmosphere. The fixture also includes advanced dimming Capabilities with 0-100% linear electronic dimming control and an independent high-speed electronic strobe function, capable of flashing 1 to 20 times per second, adding dynamic visual elements to the stage. The COB LED Blinder Light supports multiple control modes, including DMX512, master-slave, and standalone operation, offering 2/6/8/12 DMX channels for versatile control. The robust aluminum housing ensures efficient operation within a temperature range of -20°C to 40°C, with a light source lifespan of over 50,000 hours, reducing the need for frequent replacements. The fixture is designed for energy efficiency, operating within an input voltage range of AC90-260V, 50/60Hz. Installation includes the latest advanced technology signals from the lighting console, ensuring that each lighting fixture responds accurately to a single command, enhancing the overall performance of the lighting system. The project also mandates CE certification and a minimum three-year unconditional warranty on all products, with comprehensive onsite training provided to ensure the proper operation and maintenance of the installed equipment. Any deviations from the specified standards or failure to meet the recommended specifications—such as DMX signal loop in and loop out, and DMX in & out through 3 or 5-pin XLR connectors—will not be accepted. The product must be delivered fully calibrated and ready for immediate use, providing an all-in-one control solution that combines innovation with the latest technology advancements. Additionally, placement drawings of the fixtures must be approved before work assignment to ensure the correct design and end result.The entire lighting system is expected to meet the highest standards for enhancing entertainment Applications, with features like high efficiency, extended lifespan, minimal maintenance, low heat generation, and no UV output, making it a vital component in creating the perfect stage atmosphere for performing arts. |
| 241 | The scope of work encompasses the supply, installation, laying, testing, commissioning, and programming of Stage Spot Light 300W aluminum zoom LED Profile Spot Light, designed to meet advanced lighting requirements for auditoriums. The proposed product must deliver superior photometric performance and uniform field coverage, operates on AC100-240V 50/60Hz input power, with a 300W 1pcs x COB LED lamp that offers an impressive lifespan exceeding 50,000 hours and low power consumption with CE & ROH Certification standards, adjustable intensity and color temperature, color system of W.W, high Color Rendering Index (CRI) of Ra≥90, which are crucial for highlighting performers and creating various moods and scenes on stage. The control system supports DMX512 with 1/2/5 control channel modes, including Master/Slave control, Sound Active, Auto Run,and a 3/5 pin XLR input/output for DMX signal connection. The fixture also provides a beam angle option of 19°/26°/36°/50°, optimized high-definition optical system, and a glass reflector that removes over 90% of infrared radiation and reflects over 95% of visible light,dimming frequency ranging from 500HZ to 25000HZ and a strobe rate of 1-25 times/sec, the lighting solution promises smooth, flicker-free dimming from 0-100% with operational temperatures ranging from -20°C to 40°C. The installation will be meticulously executed in line with Architectural Drawings and Engineer-inCharge (EIC instructions, and will include placement drawings of fixtures prior to commencement., project will be carried out by a skilled and experienced team, using all necessarytools,machinery, and consumables to achieve the highest standards of quality, precision, and safety. The lights, fully calibrated and ready for immediate use, will create the perfect stage atmosphere, and the lighting technology used must facilitate user-friendly operation with all-in-one control solutions. The fixtures are expected to deliver high efficiency, extended lifespan, minimal maintenance, low heat generation, and no UV output, enhancing any entertainment application, any deviations from these standards will not be accepted, and higher specifications are encouraged. Each product must come with an unconditional one-year warranty, along with comprehensive onsite training for proper operation and maintenance, ensuring a seamless and successful project execution. |
| 242 | The scope of work includes the supply, installation, laying, testing, commissioning, and programming of an advanced DMX Signal Amplifier: an 8-channel DMX Extender Split & Boost DMX512 Stage Light signal to effectively boost the DMX signal for optimal stage lighting performance. The system must accommodate 3 or 5-pin XLR connectors for each light bar and luminary, ensuring seamless signal transmission without interference or signal conflict. The DMX Splitter will play a critical role in achieving the desired lighting effects by amplifying signals from the lighting console to each fixture according to the programmed lighting design. The proposed product for the auditorium must be delivered fully calibrated and ready for immediate use, creating the perfect stage atmosphere. It should incorporate the latest technology to ensure that all signals are amplified accurately and efficiently from the console to each fixture on a single command. Installation must strictly adhere to the architectural drawings and the Engineer-in-Charge's (EIC) instructions, ensuring that the design and final results meet the highest standards of quality, precision, and safety. Prior to installation, a placement schematic drawing of fixtures must be provided for approval. The installation process will include all necessary tools, machinery, manpower, staging, and consumables, carried out by a skilled and experienced team. The DMX-4/8 way Splitter must be CE certified and designed to increase the number of data bus access devices, provide optical and electrical isolation between different branches of the stage lighting system, and enhance the safety and reliability of the digital lighting control system by protecting the DMX512 output console interface and isolating fault sites. The product must feature a luminous efficacy of 90 lm/w, a product weight of 3.5 kg, and an input power range of AC110V-240V. All equipment must include an unconditional warranty covering a minimum of one year, with comprehensive onsite training provided to the end-user to ensure proper operation and maintenance. Higher or improved specifications beyond those mentioned are welcomed, provided they meet the specified make and standards. Any deviations from these standards will not be accepted. |
| 243 | The scope of work includes the supply, installation, laying, testing, commissioning, and programming of the Mini Pearl 1024 Lighting Controller with a flight case, along with a 3 to 4-day onsite training session for end-users. The product must be delivered fully calibrated and compliant with the latest advanced technology standards, ensuring immediate readiness to create the perfect stage atmosphere. The controller must feature audio signal input, MIDI input/output, RS 232 system interface, and DMX 512 signal with 1024 channels, powered by 25V DC 0.5A with full programming capabilities. The installation will strictly adhere to Architectural Drawings and Engineer-in-Charge (EIC) instructions, with the contractor responsible for the correct design, placement, and results, including the provision of schematic placement drawings of fixtures before work commencement. The contractor must supply all necessary tools, machinery, manpower, and staging, ensuring a seamless, high-quality installation by a skilled and experienced team adhering to the highest standards of quality, precision, and safety. Any specifications higher or improved beyond those mentioned are welcome, provided they align with the specified make and standards, while deviations will not be accepted. The supplied product must include an unconditional minimum one-year warranty, ensuring long-term reliability and durability. |
| 244 | The scope of work involves the supply, installation, laying, testing and commissioning of high-speed DMX data cables through ½” CONDUIT & PVC Corrugated Flexible Pipe designed for transmitting signals from the lighting console to each lighting fixture in the auditorium. The proposed DMX cables must feature 3 or 5 Pin Male XLR to 3 or 5 Pin Female XLR connectors, constructed with superior-quality materials for optimal signal integrity. The cables must be highly flexible, durable, and equipped with a water-resistant PVC jacket to withstand harsh environments, with heat-resistant inner liners ensuring signal integrity even under high temperatures. Installation will include termination with appropriate XLR connectors, covering all required points from the DMX Splitter to Light Bars, Side Ladders, and Floor Points, as per the architectural drawings and EIC instructions. The DMX data cable must be PVC insulated and multi-stranded to prevent signal loss during transmission, ensuring seamless operation of the lighting program. All work will be executed by a skilled and experienced team, adhering to the highest standards of quality, precision, and safety. The installation must be fully calibrated and ready for immediate use upon completion. Higher or improved specifications that meet or exceed these standards are encouraged, and deviations will not be accepted. wiring must come with an unconditional warranty of at least One year, and comprehensive onsite training must be provided to the end-user to ensure proper operation and maintenance of the installed equipment. 25 Feet/Pack |
| 245 | The scope of work includes the supply, installation, hanging, laying, and testing of lighting safety hooks over the light bar, ensuring full compliance with the hanging arrangement and architectural drawings as per the instructions provided by the Engineer-in-Charge (EIC). the lighting safety hook must incorporate an additional safety protection featuring a 3mm steel cable designed to meet permissible secondary safety components for high working load capacity, ensuring fall protection in accordance with the highest safety standards in entertainment rigging. The installation must be executed by a skilled and experienced team, utilizing all necessary tools, machinery, manpower, staging, and required consumables, to achieve a comprehensive and seamless installation process. The product must be delivered and ready for immediate use, with installation adhering strictly to quality, precision, and safety protocols. The lighting safety hook with required lengths, any deviation from these specifications will not be accepted, and higher or improved specifications are encouraged within the specified make and standards. |
| 246 | The scope of work includes the supply, hanging, installation, laying, testing, and programming of high-quality clamps specifically designed to securely hold energy-efficient stage lighting on light bars within an auditorium. The proposed clamps must be made of strong, durable metal, such as steel or aluminum alloy, with a protective strip to safeguard the truss or bar from damage, clamps should be compatible with professional lighting fixtures and capable of achieving the required angles for optimal lighting effects. Installation will be carried out in strict adherence to the provided architectural drawings and the Engineer-in-Charge (EIC)'s instructions, utilizing all necessary tools, machinery, and manpower to ensure a seamless and safe process. The team responsible for installation must be skilled and experienced, ensuring that the highest standards of quality, precision, and safety are maintained throughout the project, additional protective measures to prevent any accidental dislodgement, clamps must be delivered ready for immediate use, any deviations from the specified standards will not be accepted, although higher or improved specifications are encouraged and will be considered within the project's requirements. |
| 247 | The scope of work includes the supply, installation, laying, testing, commissioning and programming of a reliable electrical power system designed to handle high current loads, ensuring a stable power supply for demanding stage equipment, such as high-powered lighting rigs, in compliance with European safety standards. The system must reduce the risk of overloading while effectively protecting against short circuits, overloads, and other electrical hazards. Each lighting fixture must receive a dedicated and properly calibrated power supply, enabling precise control according to the lighting program on a single command for performing arts. The installation will be executed in strict accordance with the architectural drawings and the Engineer-in-Charge (EIC) instructions, utilizing all necessary tools, machinery, manpower, staging, and consumables to ensure a comprehensive and seamless process. A skilled and experienced team must carry out the work, adhering to the highest standards of quality, precision, and safety. The electrical system shall include 2.5mm electrical cables laying with through 2” CONDUIT & PVC Corrugated Flexible Pipe, conforming to makes such as Finolex, Anchor, Havells, Polycab, or RR Cables, with PVC insulated 3 core 2.5 sq mm FRLS cables connecting each light bar to an MCB box over the stage. This box must be connected to the main electrical panel, with each lighting bar perfectly fitted with built-in power designed to cover the entire stage. Starting from the supplied MCB Box/Panel, equipped with 10A SP MCBs or higher as per the lighting requirement, the power shall be delivered to the lighting bars or stage points, terminating at a junction box with 2 x 16 A Industrial SCHUKO sockets required point on each light bar, all clearly marked and numbered using 2.5 sq mm PVC ferrules and self-locking cable markers. The proposed products must meet or exceed the specified standards and must be delivered fully calibrated and ready for immediate use. Any deviations from these standards will not be accepted. The installation must include an unconditional warranty covering a minimum of One year, and comprehensive onsite training must be provided to ensure the proper operation and maintenance of the installed equipment. |
| 248 | Supply, installation, testing, and commissioning of the motorized horizontal center split velvet stage traveler system involves the installation of a motorized sliding curtain arrangement on a fully modular,high-precision stage curtain track, ensuring smooth operation and flawless performance. The system features an automatic motorized stage curtain with maximum cord friction and minimal slippage, utilizing a modified gearbox with sealed bearings and self-\ lubricating center split overlapped curtains for dual-side opening. This fully automated system will comply with all safety norms and include heavy-duty steel rails and tracks with a safe working load, ensuring proper weight distribution and smooth movement through a ladder-type MS frame securely fixed on top of the mother grid. The curtain mechanism will offer variable speed, programmable acceleration, and dual activation (electric and manual), controllable from both the stage and the control room, with a matte black finish. Installation will be performed by skilled labor and specialized tailors stitching with double gathering, emphasizing the stage as the main attraction. The curtains will be crafted from high-quality 100% heavy polyester Molfino fabric (450 GSM) to enhance acoustical properties, provide a reflective look, and offer luxurious fullness, work will be carried out as per architectural drawings under the supervision of the Engineer-in Charge (EIC). The installation will involve all necessary tools, machinery, manpower, staging, and consumables, including mild steel rail tracks for smooth operation, an engineered customized gearbox, and sliding traveler limit automatic stop mechanisms with rollers, clamps, runners, master runners, pulleys, and a 3mm steel wire rope, powered by a 1 HP motor (Godrej or Crompton Greaves) with an engineered gearbox, two air breaker contractors (L&T/Siemens), two micro switches for auto-stop, and three push buttons for user-friendly forward control. The curtain system will include motor mounting on a \\"C\\" channel platform, flame-retardant treatment, and optional wireless remotes, with flame-retardant textile solutions available at an additional cost. Shade and fabric samples must be approved by the Engineer-in-Charge or the end-user before installation. Curtain fabric : As physical sample approved by EIC or End-User Fabrication material : TATA, JINDAL, APOLLO & KAMDHANU Installation by : STAGE WORKS |
| 249 | Stage Frills - Teasers, also known as custom-made stage borders or short stage curtains, masking border’s purpose is to hide light bars, curtain tracks, machinery, pipe battens, projection screens, and related equipment above the stage space, Frill size and quantities is usually determined by sight lines and stage dimensions play a vital role in enhancing the aesthetics of performance stages. Stage frills provide a polished and professional look while maintaining an unobstructed view for the audience. Their custom-stitched frills perfect fit for any stage setup, contributing to both functionality and visual appeal. The frill “short stage border” will be made from cloth material in a specified shade, with onsite stitching by specialized tailors to ensure double gathering, focusing on emphasizing the stage area as the central visual element. The curtain frills, will be used to conceal equipment such as lighting – mechanism above the stage, thereby maintaining the show’s visual appeal. These frills must be precisely sized and crafted to fit the stage conditions, with options ranging from luxurious velvet borders, Expert teams will be involved in designing and manufacturing the borders to match the specific needs of the stage, The work will be executed in accordance with the Architectural Drawings and instructions from the Engineer-in Charge (EIC), encompassing the provision of all necessary tools, tackles, machinery, manpower, staging, and consumables required for the complete installation, to conceal mechanisms and unsightly wiring on stage light bars, thereby enhancing the stage’s aesthetics and functionality. Borders are typically tied up to a Mild Steel Round Pipe with a diameter of 28mm or better, designed for adjustable positioning as per the stage layout plan. |
| 250 | Designed for seamless stage adaptability, these 360-degree rotatable side wings enhance stage flexibility and performance aesthetics. The wings are constructed with 2-inch MS square pipe framework, ensuring durability and stability. The male-female MS joint system allows smooth clockwise and counterclockwise rotation, with one end fixed to the stage grid and the other secured to the stage flooring via MS round pipe male ends. The facia is covered with high-quality ply boards for a flat, functional surface and finished with a durable dark-colored fabric, ensuring a sleek and professional look. This system provides efficient scene transitions, space optimization, and enhanced stage concealment, making it an ideal choice for auditoriums, theatres, and multi-purpose performance spaces. |
| 251 | STAGE CYCLORAMA HIGH GAIN MATT WHITE PROJECTOR SCREENProviding & Fixing of Stage Cyclorama Screen which offer a versatile backdrop that can be customized with lighting and projections to create a theme, Work will be executed as per the Architectural Drawings & instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete Cyclorama is designed to provide a smooth and continuous surface that enhances lighting and visual effects transformed with lighting, projections, and special effects., creating a versatile background for various stage settings for achieving professional and aesthetically pleasing stage visuals with custom sizes to fit any stage setup by lighting the screen in different colours and patterns, create immersive experiences for the audience, with durable fabric that offers excellent opacity and light diffusion onsite fabrication of Mild Steel Pipe Frame Made Out Of 25 To 32 Mm Die Fix Frame as per shared drawings Overlapped With 1.8 Power High Gain fabric seamless joint on every 72” Matt White Projector Screen Onsite fabricated Triangle Cyclorama Frama As per Architectural Drawings, Work will be executed as per the instructions of Engineer-in-charge (EIC) including all tools, tackles, machineries, manpower, staging, any consumables, etc. complete triangular truss onsite manufactured with a structural MS Frame as per detailed drawings and fixing details from floor, rear wall and ceiling with fasteners to gain the extreme strength that contains a high+D23 amount of manganese in order to control grain structure, resulting in a stronger design. The structure is artificially aged, and provides excellent corrosion resistance. Although the surface finish is not as smooth as similar truss, Triangle frame is favored in the entertainment industry for its superior strength and durability which provides a safer stage and working environment to match visibility angles and enhancement of Stage effect lighting overlapped with Grandview high-gain matt white screen duly stretched on large tubular MS pipe frame made out of 25 to 32 mm die fix frame for projection screen: Cyclorama Screen that is manufactured using quality assured raw components and advanced technologies. Hi-Gain Cyclorama screen has been installed for Slide / film projection in a multipurpose auditorium, besides using it as color wash or for pattern projection for stage performance. Cyclorama lights are directed to fall on this screen to color wash it from top as well as Moving Heads installed on the First Intelligent Bar provide infinite pattern and depth to the screen. High-gain front projection screen with four-inch black masking studs on all sides. HD fabric Material is designed for DLP and LCD Cinema Projectors. This surface is the best choice when using a low contrast ratio projector with a high-definition video source. High Contrast is perfect for use in HD Cinema applications Screen Surface is safely washable with mild soap and water. MS STRUCTURE IN : TATA, JINDAL,KAMDHENU & APOLLO SCREEN MAKE : PRIMA, CINEMA WORKS or LIBERTY |
| 252 | Designed and fabricated onsite to accommodate site-specific conditions and ensure optimal weight distribution over the stage, this grid system is intended to enhance safety for both performers and the audience by providing structural support for various stage elements, including heavy-duty stage lighting bars, vertical side ladders, stage wings, frills, and motorized curtain tracks. The grid will be equipped with a cavity of 12mm to facilitate easy and flexible placement and adjustment of equipment, with sliding capabilities for repositioning. The structure will be supported by 12mm carbon steel/stainless steel fasteners suspended from the ceiling and side walls as required, with L-shaped 40x40x5 mm Mild Steel Angles, or 50 x 5 mm flats as needed, if required, the load may also be distributed to the proscenium. All work will be carried out in accordance with architectural drawings and the instructions of the Engineer-in-Charge (EIC), utilizing the necessary tools, machinery, manpower, staging, and consumables to ensure completion. |
| 253 | Supply, installation, testing, and commissioning of a Stage Curtain Control Panel station System comprising a wired remote-control box and a standard remote push-button box, both offering functions for Open, Close, and Stop. The system will utilize a 2.5mm twisted 4 - pair shielding, and FHDPE insulation for interlinking the splitter to the control room 4-core PVC insulated multistranded cable for signal transmission through curtain drives and a high-speed cable with low capacitance, The installation will include one main and one backup connector, adhering to the architectural drawings and instructions provided by the Engineer-in-Charge (EIC). All required tools, machinery, manpower, staging, and consumables necessary for the complete execution of the installation are to be provided. The entire setup must be installed as per the specifications outlined, ensuring proper functionality and compliance with the project requirements |
| 254 | Wooden Grooved & perforated high Density high moisture resistant panel Used on Auditorium Side WallsThe scope of work includes the providing and fixing of customized wooden grooved and perforated high-density, high-moisture resistant wall cladding for the side walls of the auditorium, designed to enhance both the interior aesthetics and acoustical performance. The wooden cladding panels will feature sound-trapping and diffracting properties, enabled by their unique grooves and perforations backed with black fleece, to effectively reduce noise levels and improve sound clarity while providing thermal insulation and moisture resistance. The system will be engineered to resist mold, pests, and physical wear, ensuring long-term durability. The installation shall be carried out by specialized skilled labor at height, under the supervision of the Engineer-in-Charge (EIC), following all necessary safety protocols and utilizing the required tools, machinery, staging, and consumables as per the approved architectural drawings and technical specifications. The work will involve the precise alignment of top and bottom tracks, utilizing galvanized iron (GI) stud channels (50mm x 0.5mm) at 450mm intervals to create a sturdy framework. Mineral Wool RB Slabs (1000mm x 500mm, 50mm thick, density 48 Kg/m³) will be inserted within the framework for enhanced sound insulation, secured with galvanized hexagonal wire mesh and covered with Plain Spun Bond Non-Woven Fabric for air filtration and added protection. The system will incorporate calculated air gaps behind the acoustic panels, which will serve to absorb low-frequency sound waves and minimize sound transmission between spaces, preventing unwanted vibrations and echoes. The final wall cladding will consist of wooden grooved and perforated panels (2440mm x 130mm x 18mm) with 2.5mm grooves at 14mm pitch, having tongue and groove edges for seamless installation. Grooves on the surface act as channels that guide sound waves into the perforations which are strategically placed to allow sound waves to penetrate the panel, backing fleece then allows to trap sound waves. Wooden Grooved & perforated high Density high moisture resistant panel, made from Non-FR grade high-density, high-moisture resistant boards, will be carefully installed by screwing them through grooves into place, and finished with an approved protective coating to safeguard against moisture, dust, and dirt. The entire installation process will adhere to high standards of craftsmanship and quality, ensuring optimal acoustic performance, thermal insulation, and a visually appealing finish, all in strict accordance with the architectural drawings. |
| 255 | Stretch Fabric Acoustical Wall System Used On Auditorium Side WallsThe scope of work includes the Providing & Fixing of Designer Stretch Fabric Acoustical Wall System, a sophisticated and aesthetically pleasing solution designed to enhance both the acoustic and thermal properties of auditorium interiors. The wall cladding system, installed on the auditorium's side walls, features sound-absorbing properties that effectively mitigate mid-to-high frequency sounds. The stretch fabric acts as a permeable covering, allowing sound waves to pass through and be absorbed by the underlying insulation system, reducing noise levels and enhancing sound clarity. Additionally, the system offers thermal insulation benefits, regulating indoor temperatures and resisting moisture, mold, and pests, ensuring long-term durability. The installation aims to improve acoustic performance by enhancing sound diffusion, clarity, and overall listening experience while providing insulation. All work shall be executed by specialized skilled labor under the supervision of the Engineer-in-Charge (EIC), following approved architectural drawings and safety protocols.To optimize acoustic performance, carefully calculated air gaps will be incorporated behind the panels to control sound wave interactions, improving sound absorption, especially at low frequencies, and reducing sound transmission between spaces. The installation process will involve the precise alignment of top and bottom tracks using lightweight galvanized iron (GI) stud channels (50mm x 0.5mm thick), with studs attached at 450mm intervals to create a smooth, flat surface. Mineral Wool RB Slabs (1000mm x 500mm, 50mPm thick, with a density of 48 Kg/m³) will be inserted within the framework to enhance sound absorption. The slabs will be secured with galvanized hexagonal wire mesh and covered with Plain Spun Bond Non-Woven Fabric for additional air filtration and protection. Customized 12mm strips made of High-Density, High-Moisture Resistance board will be fixed over the GI frame, ensuring extra strength and stability. The final stretch fabric layer will be secured using 12mm Vinyl tracks, which will be screw-fixed onto the 12mm HDHMR strips. The fabric will then be stretched over the Vinyl tracks to achieve a smooth, seamless finish, ensuring a Noise Reduction Coefficient (NRC) of 1.00. The entire installation will adhere to approved architectural drawings and include the use of all necessary tools, machinery, staging, and consumables. All work will meet the highest standards of craftsmanship, durability, and acoustic functionality, delivering a final result that is both aesthetically impressive and acoustically optimized |
| 256 | Providing & Fixing of Designer 9mm Thick Textured Fibrous Polyester Fiber Panels Over Medium Density Fiber Board Wall Cladding on Stage Side wallThe scope of work includes the Providing and Fixing of designer 9mm thick textured fibrous 100% Polyester Fiber Panels overlapped over Medium Density Fiber Board wall cladding is a comprehensive solution for improving interior aesthetics and achieving acoustic benefits such as sound insulation and thermal regulation. The polyester panels, being porous and engineered to absorb mid-to-high-frequency sounds, work synergistically with Medium Density Fiber Board to enhance acoustic dampening while preventing structural vibrations and ensuring proper alignment.The installation also reduces noise levels, oƯers thermal insulation, and resists moisture, mold,and pests, ensuring durability and long-term performance. The acoustic work will be executed by specialized skilled labor at height, adhering strictly to safety protocols under the supervision of the Engineer-in-Charge (EIC), and utilizing all necessary tools, machinery, staging, and consumables in accordance with the approved architectural drawings and specifications.Strategic air gaps behind the acoustic panels will be incorporated to optimize sound wave interaction, reducing unwanted noise, improving clarity, and enhancing sound diffusion. These air gaps will act as barriers, significantly improving sound absorption at low frequencies, minimizing sound transmission, and controlling reflections to prevent echoes, thereby delivering clear and immersive sound for the audience. The installation will begin with the precise alignment of top and bottom tracks using lightweight galvanized iron (GI) stud channels (50mm x 0.5mm thick), with studs spaced at 450mm intervals to ensure secure panel placement. A cavity will be created within the framework for enhanced sound absorption. The installation process will feature 9mm Medium Density Fiber Board secured over the GI frame up to 5 feet in height, with additional 3-inch strips of Medium Density Fiber Board installed at every 4 feet above 5 feet to ensure strength and proper ecuring of the Polyester panels. 9mm Polyester Fiber Panel of 4ft X will be carefully installed by fixing them into place with adhesive, with the final surface treated in an approved finish to protect against moisture, dust, and dirt entire installation will follow detailed architectural drawings,adhering to high standards of craftsmanship and durability, ensuring that the final outcome is both aesthetically pleasing and functionally superior |
| 257 | Mid back Add on without cupholder in Black Fabric Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail