| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 2 | M&L for non - skid coloured Ceramic tiles 7 to 8 mm thick of any shade area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointedwith epoxy filler to match over 15mm screed bed in Cement mortar (1:6) complete all as specified and directed. |
| 3 | S&F of any colour Glazed ceramic tiles 450 x 350 mm or (600 X 300 mm) x 7 to 8 mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed with epoxy filler to match over 10mm thick Rendering in Cement mortar 1:3, complete all as specified and as directed. |
| 4 | M&L for joint free Non Skid Ceramic vertified of any colour /shade/ pattern as approve of size exc .18 sqm but not exc .36 sqm in floor etc. set and jointed in neat cement slurry and pointedwith epoxy filler to match over 15mm screed bed in Cement mortar (1:6) complete all as specified and directed. |
| 5 | Taking down Chowkat or Frame with shutters (without taking off Shutter from the Frame) not exc. 1.50 Sqm Each, complete all as specified and as directed. |
| 6 | Taking down chowkats or frames exc 1.5sqm and not exc 4.0 sqm each with shutters ( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts. complete all as specified and as directed. |
| 7 | S&F 1st class HW (Teak wood) Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints,complete all as specified and directed |
| 8 | S&F 1st class HW (Teak wood) 35 mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats but divided into squares, with plain chamfered or rounded, mitred and rebated sash bars, any t with edges of sash bars and framing moulded if prepared to slide horizontally on beads including supplying and fixing beads complete all as specified and directed. |
| 9 | M&L 8-10 mm thick toughned glass selected quality incliding eaching of any patterns as directed in each pane obscured or frosted on one side complete all as specified and as directed |
| 10 | S&F 300mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed. |
| 11 | S & f Brass handles, cast type, polished bright 150-210mm size complete all as specified and directed. |
| 12 | S & F in repairs Brass mortice lock verticle type 75 mm 4/6 levers complete all as specified and directed |
| 13 | S & F100mm Butt hinges, extruded brass with galvanised mild steel hinge pin,bright polished and fixed, type B-11, complete all as specified and directed |
| 14 | S & F In repairs Double action floor spring heavy duty hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty all as specififed and directed |
| 15 | M&L for three coats of French polishing on wooden surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed |
| 16 | S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges will be painted to match with printed sdeet PVC sheet reinforced with MS square tube,suppling & fixing in opening as per specification & Drawing, complete all as specified and as directed. |
| 17 | S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed. |
| 18 | S&F 20mm bore CPVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors incl conceiling/ clamping etc and taking down or up of GI/CPVC/ UPVC Pipe, complete all as specified and directed |
| 19 | S&F 15mm bore CPVC pipes of pressure rating 10 kgf/cm2 fixed complete towalls, ceilings or in floors incl conceiling/ clamping etc taking down or up of GI/CPVC/ UPVC Pipe, complete all as specified and directed. |
| 20 | Demolition of reinforced cement conc of any description and in any position complete all as specified and as directed. |
| 21 | M&L reinforced cement concrete Type B1 (1:2:4) (20mm graded aggregate) in slab supported on walls, beams, and columns, in floors, roof, landings balconies, canopies, etc cooking slab and in shelves, complete all as specified and directed. |
| 22 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and as directed. |
| 23 | Formwork to soffits of suspended slabs such as cooking slab and similar work; not exceeding 200mm thick (Horizontal or sloping) all as directed. |
| 24 | M&L 20mm thick Granite (of any type) type work (table rubbed and polished) in cooking platforms and like fixed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match over with shade of granite complete all as specified and as directed. |
| 25 | M&L 20mm thick Granite (of any type) work (table rubbed and polished) for in skirting/border with 12 mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shed of granite complete all as specified and as directed. |
| 26 | M&L Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of makrana white complete all as specified and as directed. |
| 27 | M&L Marble work (table rubbed and polished) for wall lining (veneering to wall) 25mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of Makrana white complete all as specified and as directed. |
| 28 | S&F in repair 15mm bore two way bib cock cast copper alloy CP Fancy type ,with wall flange screwed down for iron pipe or union , complete all as specified and directed. Of approved Models,as approved by GE. |
| 29 | S&F in repair 15mm bore health faucet (ABS body) with 8mm Dia, 1.2 m long flexible tube & wall of approved models as approved by GE. complete all as specified and directed. |
| 30 | S&F in repair chromium plated toilet paper holder complete all as specified and directed.of approved models ,as approved by GE. |
| 31 | S&F 08 mm thick curved shaped urinal partition with frosted glass of size 900x450 mm including fixing accessories, fixing bolt, etc complete all as specified and directed. |
| 32 | S&F 5 mm thick Designer mirror with back light and fixed in to chromium plated / stailess steel cup washers spacers of approved pattern as directed by Ingr-In-charge complete all as specified and as directed .of approved Models,as approved by GE. |
| 33 | S&F in repair towel Rail chromium plated complete all as specified and directed as approved by GE complete all as specified and directed. |
| 34 | S&F in repair towel ring chromium plated complete all as specified and directed. as approved by GE |
| 35 | S&F in repair chromium plated Corner/ front glass shelf with bracket complete all as specified and directed. |
| 36 | S&F PVC connection 15mm size with PTMT nuts of length 450mm complete complete all as specified. |
| 37 | Supply and fix,as in repair, waste coupling CP 32 mm dia for glazed ware basins etc with fly nuts flanged etc complete all as specified and directed. |
| 38 | S&F 32mm bore brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and ditected |
| 39 | S&F PVC (SWR) floor trap 75 mm size with grating including jointing with solvent cement complete all as specified and as directed. |
| 40 | S&F PVC (SWR) multi floor trap 75 mm size with grating including jointing with solvent cement complete all as specified and as directed. |
| 41 | S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed |
| 42 | S&F PVC (SWR) pipes 75mm single socketed in any length with rubberring joints laid in trenches or in floors incl dismantling complete all as specified and as directed. |
| 43 | S&F PVC (SWR) pipes 110mm single socketed in any length with rubberring joints laid in trenches or in floors incl dismantling complete all as specified and as directed. |
| 44 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed |
| 45 | S&F Angular stop cock cast copper alloy CP with wall flange for 15mm bore approved by GE complete all as specified and directed. |
| 46 | Supply and fix, as in repairs, grating round/ Square Anti foul cockroach proof 100 mm dia size of stainless steel all as specified and directed. |
| 47 | Demolition of brickwork or stone/boulder masonry, built in cement mortar complete all as specified and directed. |
| 48 | M&L for old size sub Class B bricks, straight or curved on plan exc 6 m mean radius built in cement mortar (1:6) having compressive strenght not less than 75 kg/Sq complete all as specified and directed. |
| 49 | Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 50 | M & L, 10mm thick rendering in C.M. (1:6) on brick work finished even and smooth without using extra cement complete all as specified and directed. |
| 51 | M&L Applying two coats of Emulsion distember to newly plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly platsered wall all as specified and directed. |
| 52 | M&L complete removal of existing treatment and Applying two coats of Oil Emulsion distember to old plastered/previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer including preparation of newly platsered wall all as specified and directed. |
| 53 | M&L Applying one coat of Oil Emulsion to old wall surfaces of walls and cornices including preparation of old decorative surface and removal of smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot complete all as specified and directed |
| 54 | M&L Applying two coats Oil Emulsion distember to old plastered/previously untreated ceiling by washing, rubbing down and stopping of distempered and painted surfaces over a coat of 1 mm layer wall care putty including preparation of old platsered ceiling complete all as specified and directed. |
| 55 | M&L for Old wall surface including properly preparation/removal of existing paint surface and fillings the cracks with exterior wall care putty and pigment and applying one coat of weather coat water proofing paints as in boundry wall, single , double and triple storey bldg, complete all as specified and as directed by Engineer-in-Charge. |
| 56 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. complete all as specified and directed. |
| 57 | S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & entilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge complete all as specified and directed. |
| 58 | S&F 4 mm thick heat absorbing/tinted/shaded glass for windows of any size with aluminium bedding and complete all as specified and directed. |
| 59 | S&F 4 mm thick frosted/ pin headed glass in ventilator shutters incl hacking out all as specified and directed by Engr-in-Charge |
| 60 | Demolation of Wall and ceiling boards (fibre, pulp, instalation,etc.) or instalation boards/Slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed. |
| 61 | M&L for Providing and fixing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed |
| 62 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. complete all as specified and directed. |
| 63 | S&F 6-10 mm thick PVC hollow panels with to 0.5 mm plain PVC sheet suitably placed in Wall inclding same and matching colour wall angle , u clip, end elip and jointer . As in ceiling and walls including aluminium frame work fixed to wall or wooden scantling vertically and horizontally at an interval as directed by Engr-in-Charge all as specified and directed. |
| 64 | S&F ss rack of Grade-304, size6 ft comprtment -4.1 ft length 2.2 ft width and 6ft height ,3ft each compartment made of stainless steel which is known for its durability, corrosion resistance, and ease of cleaning. Approved by GE, complete all as specified and directed. |
| 65 | S&F SS of Grade-304 over head storage, size -8 ft length, 2 ft width and 20\\" height ,-3 side covered made of stainless steel which is known for its durability, corrosion resistance, and ease of cleaning. Approved by GE, complete all as specified and directed. |
| 66 | S&F SS of Grade-304 over head storage, size-14 ft 8\\" length, 2 ft width and 20\\" height ,covered made of stainless steel which is known for its durability, corrosion resistance, and ease of cleaning. Approved by GE, complete all as specified and directed. |
| 67 | S&F SS of Grade-304 COUNTER WITH UNDER STORAGE INNER (rt side) - 32ft1\\"(L)*2.5fT(W)*2ft10\\"(H) - 4ft ( 4 tables) + 1.8 ( 1 table) + 3.10 ft( 1 table)+ 5.11ft(1 table) + 4.6ft(1 table) Approved by GE, complete all as specified and directed. |
| 68 | S&F SS counter Top of Grade-304 with under storage of Grade-204 for inner (IMOV)storage, size - 4.5 length, 2.5 ft width and 2ft 10\\" height ,covered made of stainless steel which is known for its durability, corrosion resistance, and ease of cleaning. With wheels, Approved by GE, complete all as specified and directed. |
| 69 | S&F SS of Grade-204 COUNTER WITH UNDER STORAGE INNER (lt side) - 16ft10\\"(L)*2.5ft(W)*34 \\" inch WITH 2 SHELVES- 4.11(1 table) + 4.10( 1 table)+ 4.11(1 table) Approved by GE, complete all as specified and directed. |
| 70 | S&F SS COMMERCIAL TYPE SINK of Grade-304 IN INNER KICTHEN - 01ftplain + 03ft(L)*01ft(D)*2.5ft(W)*2ft10\\"(H) - 3feet sink (2pcs) Approved by GE, complete all as specified and directed. |
| 71 | S&F SS of Grade-304 HOOD WITH SS FILTER - 12ft. Approved by GE, complete all as specified and directed. |
| 72 | S&F DUCTING - 20ft. Approved by GE, complete all as specified and directed. |
| 73 | S&F AXILE FAN. Approved by GE, complete all as specified and directed. |
| 74 | S&F UG LPG LINE CONNECTING TO LPG BANK OUTSIDE - 15ft. Approved by GE, complete all as specified and directed. |
| 75 | S&F 4*8 SS of Grade-304 MOVABLE COUNTER (outer) - 8ft(L)*4ft(W)*34\\" inch (H) with 2 undershelf = 4*4 ( 2 table sq. With wheels). Approved by GE, complete all as specified and directed. |
| 76 | S&F SS COUNTER of Grade-204 CUPBOARD (OUTER) - 15ft6\\"(L)*2.5ft(W)*2ft10\\"(H) = 21\\" inch + 3.11 + 5.11 +3.11. Approved by GE, complete all as specified and directed. |
| 77 | S&F SS OVERHEAD STORAGE of Grade-304 (outer)(2*compartment) - 8ft6\\"(L)*2ft(W)*30\\" (H) 15\\" FOR EACH COMPARTMENT = 4ft (2 ft overhead shelf) + 15\\" inch gap in between. Approved by GE, complete all as specified and directed. |
| 78 | S&F 03* COMMERCIAL TYPE SS of Grade-304 SINK OUTER KITCHEN - 2.5ft(L)*01ft(D)*2.5ft(W)*2ft10\\"(H) (3.5ft plain). Approved by GE, complete all as specified and directed. |
| 79 | S&F of ss jali Grade (of Grade-304) of round hole of any dia as approved for Drainage Line incl nessary cleaning arrangement of any size and shape approved by GE, complete all as specified and as directed |
| 80 | Demolition of old damaged existing water proofing compound on RCC roof of any description and specification and cleaning the surface thoroughly, complete all as specified and directed |
| 81 | M&L Grading roof for water proofing treatment with 40 mm thick Cement Concrete 1:2:4 type B1 20mm graded aggregate, complete all as specified and as directed. |
| 82 | M&L Surface Preparation: Remove angle and all necessary items along with all surfaces to receive the waterproofing coating to be mechanically cleaned properly so that there will be no dust, laitance, oil, grease etc. Cementitious Grouting (If required): Nozzle grouting to be done with cement slurry admixed with expanding grout admixture Cebex 100 @225 gm per bag of cement using pressure grouting pump with a pressure of 2 to 2.5 kg/sqcm after ponding test for 72 hours. Bore Packing: Providing necessary formwork for packing the bore using suitable arrangement (depending upon site conditions). Applying a coat of styrene- butadiene based polymer coating using Nitobond SBR to enhance adhesion between the packing material and other surfaces and packing the gap using non-shrink cement polymer-based grout using Conbextra GP2 upto the surface of the bore whilst the Nitobond SBR Mortar. Coving & crack treatment: The junction of the peripheral wall and slab is to be clean properly by removing all residues of dust and dirt. Coving the junction of slab and vertical offsets 50mmX50mm with CM 1:4 mixed with Nitobond SBR Latex 10% by wt of cement. Waterproofing layer: The substrate must be primed. For sound, dry concrete prime. The primer shall be allowed to become touch-dry prior to application of Fosroc Burshbond Roofgaurd Premium, Brushbond Roofguard Premium to be applied in two coats by roller or brush or squeegee or by airless spray at a wet film thickness of 0.5 mm per coat. This is the recommended technique for applications onto vertical surfaces. Allow the first coat to dry (normally 1-5 hours depending on the climatic conditions), then proceed with the application of the second coat. The second coat of Brushbond Roofguard Premium should be applied at 90° to the first, ensuring that a final continuous coating with a minimum total applied wet film thickness of 1 mm is achieved, resulting in a total dry film thickness of 0.8mm.complete all as specified and as directed. |
| 83 | S&F Solid WPC particle board for cabinet consisting of 18-20 mm thick prelaminated PVCsheet inclusive of solvent cement and fixing at site complete all as spacified and directed. |
| 84 | S & F continuous(Piano) hinges 30 mm width mild steel ,bright finish fixed with screw complete all as specified and directed. |
| 85 | S&F bal catches with 8 mm dia steel ball magnet catches for cuboard shutter including strking plate as approved etc complete all as specified and as directed |
| 86 | S & F 40 mm dia cupboard knob fixed with nut ,screw and washer of brass polished complete all as specified and directed. |
| 87 | S&F in repair vitreous china Table top Basin of approved shape & size including taps, waste chain, plug and porcelain stopper, brackets, cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 88 | Supply and fix 15 mm bore pillar Mixture tap sensor type without Popup Waste system with 450MM long Braided Hoses of approved Models hot and cold type , as approved by GE.complete all as specified and directed |
| 89 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern) single piece with PP soft close seat cover, hinges, duel flush chistern fitting and complete accessories set in white colour of approved models as approved by GE, complete all as specified and directed |
| 90 | S&F in repair sensor based urinal of approved shape & size. complete as per manufacture's instructions and approval of garrison engineer.all as specified and directed |
| 91 | S&F Flash touch free infared hand dryer with 1150 W rated poer &carbon brush motor of stainless steel body complete all as specified and directed. of approved models ,as approved by GE. |
| 92 | S&F automatic soap dispenser of capacity 0.8 ltr of aluminium/Abs with chromium finish complete all as specified and directed. of approved Models,as approved by GE. |
| 93 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. including cutting chases of exsisting wall for wall taking out concealed conduit ec. and making good disturbed surfaces of walls, floors, etc as per existing specification after providing point wiring under respective items here-in-below complete all as specified and as directed. |
| 94 | Taking down main switches and DBs of any type and make including wooden board / junction box. |
| 95 | M&L for concealed point wiring for one Light/ Fan/ Bell point complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20 mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, with and including modular metal flush box and Modular white Cover Plate with Frame for fixing modular switches, sockets fan regulators etc duly earthed. Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles complete all as specified and as directed. Note- The cost of Blanking plate if required shall deemed to be included in the unit price. |
| 96 | All as per item No. 95 here-in- before but for 3 pin 5 Amps switch socket combination on independent board with 1.5 sq mm copper cable complete all as specified and as directed. |
| 97 | All as per item No. 95 here-in- before but for 3 pin 15 Amps switch socket combination on independent board with 2.5 sq mm copper cable complete all as specified and as directed. |
| 98 | All as per item No. 95 here - in - before but for 5 Amps socket point on the same board controlled by one switch. |
| 99 | S&F modular switch flush type, 6 Amp, one way ,1 module all as directed specified. |
| 100 | S&F modular socket outlet, 3 pin, 6 Amp, flush type 2 module all as directed/ specified. |
| 101 | S&F modular switch, 16 Amp flush type 1 module all as directed/ specified. |
| 102 | S&F modular socket outlet, 3 pin, 6/16 Amp flush type 2 module all as directed/ specified. |
| 103 | S&F modular Fan Regulator stepped type 2 module ,120W all as directed/ specified. |
| 104 | S&F ceiling rose surface backelite three terminals. |
| 105 | Supply and fix LED tube light fitting of 18 W (4 Ft) 240 V Wall mounted LED batten aluminium houseing and integrated electronic driver with high efficient LEDs 18 Watt with acessories suitable for operation on AC single phase 220/230 volt 50 Hz supply complete with all accessories internally pre-wired and inclg connection. |
| 106 | All as item no 105 above but LED batten 9 watt 2 ft long |
| 107 | S & F in repair 15 Watt LED fitting Recess mounted downlighter (Round/Square) motion sensor of 4.5 m sense radius with independent electronic LED driver ensuring glare free light with all its surface module accessories including comlpete all as specified and directed. |
| 108 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and directed. |
| 109 | Supply and fix Heavy Duty Comercial type electric kitchen Chimney min 16 ft x 2.5 ft size, 3000 cum/hr, wall mounted/self supported/ceiling mounted auto- Clean curved glass kitchen Chimney made of SS 304 with exhaust fan motor of 1400 RPM including necessary fitting and cutting/hole in roof/wall suitable size complete all as specified and directed. |
| 110 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers complete all as specified and directed by the Engr-in-charge. |
| 111 | Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Tripple pole and neutral (TPN) 415 Volt , double door, suitable for 4 way with dim rail earth and neutral bar all as specified and as directed. |
| 112 | S & F Sheet metal enclosure for MCB DB double door single pole & Neutral 12 way with common bus bar at incomming end complete all as specified and directed |
| 113 | S & F MCB 'C' series Triple pole and nutral 100 Amps, breaking capacity 10KA complete all as specified and directed |
| 114 | S & F MCB 'C' series Single pole and nutral 40-63 Amps, breaking capacity 10KA,complete all as specified and directed |
| 115 | S & F MCB 'C' series single pole 6 to 32 Amps, breaking capacity 10KA,complete all as specified and directed |
| 116 | S&F metal clad socket out let with MCB single pole and nutral 20-32 Amp, 240 V including sheet metal enclosure complete fixed on board including complete electrical connection by proper size of copper lugs complete all as specified. |
| 117 | M&L in repair for sub main wiring with Four run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 4.0 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length. |
| 118 | M&L in repair for sub main wiring with Four run of 6.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and two run of copper earth wire 6.0 Sq mm drawn through PVC conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length. |
| 119 | NOTES:1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. Please Enable Macros to View BoQ information |