| 1 | Demolition of cement concrete (unreinforcement) as in ground floors or paving n.exc 15cm thick below or above ground level complete all as specified and directed. |
| 2 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid and pointed in any type of mortar complete all as specified and directed. |
| 3 | M&L for machine cut kota stone slab flooring 20-22 mm thick over and including 15mm thick screed bed of cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab and rubbing and polishing complete all as specified and directed. |
| 4 | M&L for machine cut kota stone slab 20-22 mm thick in skirting and dado, laid over and including cement screed cement mortar (1:4) jointed, with grey cement slurry mixed with pigment to match the shade of the slab and rubbing and polishing complete all as specified and directed. |
| 5 | Providing edge moulding to 18-20mm thick stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. Complete all as specified and directed |
| 6 | M&L for 75 mm thick cement concrete 1:3:6 ,type C-2 ( using 40mm graded stone aggregate) as in plinth potection finished cement concrete surfaces even and smooth without using extra cement all as specified and directed. |
| 7 | M&L for forming construction joint 30 mm deep x 10 mm wide filled with sealing compound grade 'A' ( bitumen and sand 1:3) complete all as specified and directed. |
| 8 | Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed. |
| 9 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc. 6 mtr mean radius built in cement mortar (1:4) all as specified and directed. |
| 10 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) all as specified and directed. |
| 11 | Taking down of cement plaster including hacking out of joints, hacking for key, scrubbing down with water etc in any position in multi storey building all as specified and directed. |
| 12 | M&L for 10mm thick rendering in cement mortar 1:6 on fair faces of concrete/wall surfaces finished fair and smooth without using extra cement. |
| 13 | M&L for 15mm thick rendering in cement mortar (1:4) finished fair and smooth mixed with water proofing compound @ 200 ml per bag all as specified and directed. Note : WPC measured and paid separately |
| 14 | Supply only Liquid water proofing compound. |
| 15 | M & L for preparation of new plastered surfaces of walls and filling with minimum 1.50 mm thick wall putty and applying two coats of oil bound distemper including one coat of primer on plastered surfaces complete all as specified. |
| 16 | Material and labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces using Airless Paint Primer Sprayer using smart technique, on newly plastered surface of wall, cornices complete all as specified and directed. |
| 17 | Dismantling wrought iron or mild steel work of any description and in any position complete all as directed. |
| 18 | S&F for rolled mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-w (Gde-E250) quality 'A' all as specified and directed. |
| 19 | M&L for preparation of new steel surface over 10cm girth or width and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 20 | Dismantling plain or corrugated AC steel sheeting, any gauge, thickness, including Nanital or similar pattern roof coverings complete all as specified and directed. |
| 21 | M&L for insulated PUF (Polyurethane foam) corrugated roofing sheet of 40 thk with a CAM lock jointing system including 0.5mm thick PPGI (Pre coated galvanised iron) sheet on both the top and bottom with 40Kg/m3 density PUF core. The panels are joined with a tongue and groove system and cam locks core insulation: Rigid, closed-cell, CFC-free polyurethane foam. Core density:40 Kg/m3, as in roof covering/ cladding to wall fixed over MS angle iron trusses and purlins all as specified and directed. |
| 22 | All as per item No 21 here-in-before but for plain sheet as in ridges. |
| 23 | M & L for Powder coated roof top mounted turbo ventilators of any colour, non-electric exhaust syatem of size 600mm of Stainless steel (SS) and Aluminium highly corrosive environments all SS 304 fixing over Roof as per manufacturer instruction complete all as specified and directed. |
| 24 | M & L for smartcare damp proof ultra or equivalent make as specified in PS with PU hybrid polymers and reinforcing acrylic polymers, resist hydro static pressure upto 10 Bars, CBA of 2.5 mm at 650 micron. Application needs to be done in 03 coats (i) 1st coat 30 % dilution with water. (ii) Application of 2nd Coat & 3rd coat without any dilution. in between 2nd and 3rd coat 40 GSM geotextile needs to be applied to provide better elongation & reinforcement Note: Consumption-1.20 Kg for 03 coat per Sqm and elongation-4005, tensile- 2.90 mpa, solid content-55 %, Specific gravity- 1.15 gram/CC, SRI-106 all as specified and directed by manufacturers instruction. |
| 25 | M & L for repairing of concrete surfaces of ceiling by cleaning the damage area, remove loose debris and supply a cement based repair compound, P/F of 0.51 mm iron sheet with 1.5mm x 1.5mm iron angle and 20 x6 mm iron flat bar welding labour charge and applying two coats oil bound distemper over a coat of primer complete all as specified and directed. |
| 26 | M & L for cutting out cracks to V-section in existing roofs, floor or terracing, cleaning out, wetting, grouting with cement and sand slurry (1:3) with water proofing compound as per Manufacture's instruction complete all as specified and directed. |
| 27 | M & L for adding water proofing compound of Make- SIKA, Sikadur-20 Crack Seal (or equivalent specified in PS) is a solvent free, 2-component low viscosity and semi elastic liquid, based on epoxy resins for sealing of cracks and cavities in concrete floor and finishing neatly as per direction all as specified and directed. |
| 28 | M & L for 15mm thick terrazzo topping with 7 to 10mm size marble aggregate including grinding and polishing in floors with grey cement and no pigment complete all as specified and directed. |
| 29 | M & L for grinding and polishing of existing any type and any thick of terrazzo flooring including all necessary work required complete all as specified and directed. |
| 30 | Taking down carefully aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed. Please Enable Macros to View BoQ information |
| 31 | Taking down carefully aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed. Please Enable Macros to View BoQ information |