| 1 | Dismantling timber frame, framed work as in fillets, rails, posts, purlins, etc under 40 sqcm in section. complete, all as specified & directed by Engineer-in-charge. |
| 2 | M&L for second class hard wood in scantling, clean sawn timber framed and fixed work complete, all as specified & directed by Engineer-in-charge. |
| 3 | Dismantling timber framed work as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section, complete all as specified and as directed by Engr-in-Charge. |
| 4 | M&L for second class wrought hard wood plain fillets, square, rectangular or triangular in section, sectional area 13 sqcm but n exc 25 sqcm, secure with screws,complete, all as specified & directed by Engineer-in-charge. |
| 5 | Plugging to walls complete for wood fillets, grounds moulding, etc. on cement concrete walls, at distance n. exc 1 mtr complete all as specified and as directed. |
| 6 | Dismantling of boarding, any description, fixed in any position with nailst and including fillet etc, complete all as specified and as directed by Engr-in-Charge. |
| 7 | M&L for 9 mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work fixed in ceiling complete, all as specified & directed by Engineer-in-charge. |
| 8 | M&L 3mm thick Cover fillets of tempered hard board, 40mm wide and fixing with screws all as Specified |
| 9 | Dismantling wall and ceiling board or insulation boards any thickness including cover fillets complete, all as specified & directed by Engineer-in-charge. |
| 10 | M&L in repair Anodised aluminium snap grid frame work Size of grid 605 x 605mm for false ceiling complete all as specified and directed . |
| 11 | S&F in repair Hangers (Size of grid 605 x 605mm) 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified complete all as specified and directed. |
| 12 | M&L for 12 mm thick gypsum board in ceiling fixed with screws as per manufactureres instruction, complete all as specified and as directed by Engr-in-Charge. |
| 13 | S&F in repair anodised aluminium frame for doors, windows, ventilators or in partitions with one or more rebates including jointing, cleat glazing clips, aluminium mongry etc fixing of sheet glass and particle board complete all as specified & directed by Engineer-in-charge. |
| 14 | Taking down aluminium doors ,windows, ventilator shutters any size or in any position complete all as specified and directed. |
| 15 | S & F anodised aluminium door shutters, fixed type without sash bar, aluminium section weighing 0.55 Kg/m including necessary jointing cleats , glazing clips , rubber neoprene packing , 2 Nos handle 150 mm long and two nos of 150mm long aluminium tower bolots. in each shutter, hinges , anonised aluminium snap beading fixed with screws complete all as specified and as directed. |
| 16 | Supply and fixing 5.5 mm thick tinted glass in square exc 0.5 sqm in each pane with heat reflecting properties , fixed to aluminium frame or door with glazing clips, etc., complete all as specified and as directed by the Engineer-in-Charge. |
| 17 | M&L in repair for 4.8 mm thick sheet glass ordinary quality and glazing with aluminum section beading in square n. exc. 0.5 Sqm in each pane, complete all as specified and as directed. |
| 18 | M&L in repair 19mm thick Prelaminated particle board, interior grade, prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and as directed. |
| 19 | Taking down chowkats or frames not exc 1.5 Sqm each with shutters ( with out taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed. |
| 20 | Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 Sqm each with shutters ( with out taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed. |
| 21 | Taking down shutters of any description exc 1.00 Sqm but not exc 2.00 Sqm each complete all as specified and directed. |
| 22 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete, all as specified & directed by Engineer-in-charge. |
| 23 | S & F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and as directed. |
| 24 | S&F fabricated flush shutters, 30mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete, all as specified & directed by Engineer-in-charge. |
| 25 | Material & Labour 2nd class hardwood made 30mm thick glazed skelton shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in SSR part-I section 8 clause 8.24(a) supplt and fixed to choukats complete all as specified and directed by Engineer-in-Charge at site. |
| 26 | S& F Galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm as in gauze door /window/ventilators shutters complete, all as specified & directed by Engineer-in-charge. |
| 27 | S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised .complete, all as specified & directed by Engineer-in-charge. |
| 28 | S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete, all as specified & directed by Engineer-in-charge. |
| 29 | S&F for Butt hinges, 125mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and as directed by Engr-in-Charge. |
| 30 | S&F butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21, 100mm long complete, all as specified & directed by Engineer-in-charge. |
| 31 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed. |
| 32 | S&F 150mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed with door complete all as specified and as directed. |
| 33 | M&L for preparing new or previously untreated wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic varnishing finishing coat, over a coat of wood filler coat complete, all as specified & directed by Engineer-in-charge. |
| 34 | S&F Door closer hydraulically regulated, aluminium body designation No. 2, universal type, complete all as specified and as directed. |
| 35 | S&F in repairs mild steel ordinary rat tail rod pattern 300 mm long door spring incl roller and roller plate etc, complete all as specified and as directed by Engr-in-Charge. |
| 36 | S& F in repair anodised aluminium alloy curtain rails incl brackets, stops, rollers etc, complete all as specified and as directed by Engr-in-Charge. |
| 37 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone,concrete or brick surrounds, glazed with putty of fixed with beads complete all as specified and directed. |
| 38 | S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 39 | S&F in repairs vanishing blinds of vertical/Horizontal type of any colour including its opration rod counter weights & pelmet moving channel for blinds complete all as specified and as directed by Engr-in-Charge. |
| 40 | S & F in repairs laminated wood flooring 8mm thick, including skirting, floor brakers etc, as per manufacutred instruction with a layer of foam backing, complete, all as specified & directed by Engineer-in-charge. |
| 41 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering etc ccomplete, all as specified & directed by Engineer-in-charge. |
| 42 | S&F 0.63 mm thick Galvanised, corrugated mild steel shetting with two corrugations side lap, fixed with coach screws, washers, and L - type or J-type or cranked hook bolts in lieu of screw in roof sheeting, walls etc. with grade of zinc coating 275 etc complete, all as specified & directed by Engineer-in-charge. |
| 43 | S&F 0.63 mm thick plain, galvanised, mild steel sheeting (minimum zinc coating 120 gm / sqm) as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and directed. |
| 44 | M & L Synthetic enamel paint two coats on new steel surface any description over 10cm width or girth over a coat of red oxide primer including preparation of surfaces in camouflage pattern complete all as specified and as directed. |
| 45 | Dismantling wrought iron or mild steel work of any description completely all as specified and directed |
| 46 | S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 47 | S&F rolled mild steel section in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed. |
| 48 | M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 grade St-240 complete all as specified and directed. |
| 49 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete, all as specified & directed by Engineer-in-charge. |
| 50 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 51 | M&L for PCC (1:2:4) Type B-1, Plain cement concrete with using 20mm graded aggregate in lintels upto 1.5 m clear span, copings, bed plates, cills, steps: seismic and other similar bands, plinth course, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, complete all as specified and as directed. Please Enable Macros to View BoQ information |